Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

Similar documents
Recommendations/Comments for "IPC 1601" (Implementation subject to customer/supplier agreement)

DRY PACK INFORMATION TROCKENVERPACKUNG

RFFM6403. Manufacturing Notes. Table of Contents

Product Brief. specification. UV Module Solution. Description. Features and Benefits. Key Applications CMW-PS-C01. Table 1.

Manufacturing Notes for RFPA2189

Manufacturing Notes for RFDA0025

Manufacturing Notes for RFPA2016

RFSW6132. Manufacturing Notes. Table of Contents. 1 Introduction... 2

Manufacturing Notes for RFMD2081

RoHS. Specification SAWW9H0A. 서식번호 : SSC-QP (Rev.00)

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

ULTRA-LOW HUMIDITY STORAGE CABINETS 1, 3%RH

Preliminary specification

SMT450. High Performance TOP LED

SMD 2121 Black Frame MC-S2121BHA

3SP_H2S_50 Package

3 3SP_O3_5 C Package

Reflow Soldering Guidelines

SPECIFICATIONS FOR REFOND SURFACE MOUNT LED

HIGH QUALITY VAPOR PHASE REFLOW SOLDERING. SMTA Arizona-Sonora December 4th 2012

PRODUCT SPECIFICATION

ULTRA-LOW HUMIDITY SEIKA. ERC Co., Ltd. ULTRA-LOW HUMIDITY STORAGE CABINETS 1%RH. Conforms to IPC/JEDEC J-STD-033D and IPC-1601 Guidelines.

IAQ_100 C Package

When Precision is not good enough

Application note. LCD Module. Precautions for LCM handling. LCM handling V 1.1

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Specific Lighting Product Data Sheet M08 CoB Product Series Data Sheet Spec No.: DS Effective Date: 12/15/2016 LITE-ON DCC RELEASE

PRODUCT SPECIFICATION

High Power COB LED. Features. Applications. ① Product line code: COB10W-C & COB10W-W. ② Product code base plate. ③ Chip code. ④ Emitting light colours

THERMOPLASTIC - NYLON FLAT WASHERS AND SPACERS

Used as indicators of indicating the Degree, Functions, Positions etc, in electronic instruments

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

A214B/SUG/S400-X6 LAMP. Features. Description. Applications. Revision 1. Expired Period: Forever. LifecyclePhase: Low power consumption

STORAGE & LAMINATION INSTRUCTIONS

Copyright 2010 Plastipak Packaging, Inc. All rights reserved.

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

PRODUCT SPECIFICATION

Air-Water heat pump Small GT

Teknomar Brand Industrial Type ETO Sterilizer ETO C 1445 Data Sheet

One-Side Clear Active Barrier Packaging for Moisture Sensitive Medical Devices:

45 Wide Format Hot and Cold Laminator

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

2015 Amphenol Advanced Sensors. Jinton Industrial Park, Wujin, Changzhou, Jiangsu, China. Web:

PRODUCT SPECIFICATION

What cannot be cleaned in a stencil cleaner? Prepared by Steve Stach

SPECIFICATIONS. US0603YG LED Chip 0603 Yellow Green SWISSDIS. Swissdis AG Grasweg 7 CH-4911 Schwarzhäusern

Operator s Manual. IP-100 Immersion Probe Cooler

Inverted Through Board Surface

NIDS Dust sensor ED-N-DS-1408

OPERATION MANUAL Model 800 Nanoimprint Controller

Understanding Etched Foil Flexible Heaters

Brazed heat exchangers

SonoSelect and SonoSafe energy meters

Electrical Configuration: Two single sensing elements and two compensating elements are connected to built-in FET in source follower circuit,

10.A4 Modified atmosphere packaging machines

AIR CONDITIONING COMPRESSOR OIL

HULME MARTIN HEAT SEALERS

Full System Moisture Management for Drug Preservation

Pressure Transducers Ultrahigh-Purity

ENGINEERING SAMPLES PYRO-ELECTRIC IR-DETECTOR

NOT EVERYTHING IN LIFE IS COMPLICATED.

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

A. Air Handling Units shall be designed to the specific requirements of the application: Recirculation or 100% Makeup.

Metal, ceramic, plastic package products

UM Store and transport requirements. Document information

STONETECH Maintenance & Care Porcelain, Ceramic & Quarry Tile with Cement Grout

Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Aerospace. Aerospace. Okazaki. Innovation not Immitation. Temperature Sensors

Electron Microscopy Sciences

Application Note 5305

SUNCOURT INSTALLATION INSTRUCTIONS RADON FAN MODEL: RDKO4, RDK04-3, RDN04 & RDN04-3

FSA-Series Heavy-Duty Flat panel Emitter Architectural Electric Overhead Infrared Heaters

Pressure Measurement Solutions HVAC AND REFRIGERATION SYSTEMS.

TECHNICAL CERTIFICATE USER MANUAL THERMOSTAT TP years warranty

INSTRUCTIONS FOR CLEANING AND STERILIZATION OF ALL B.BRAUN AESCULAP HAND HELD SURGICAL INSTRUMENTS AND POWER PRODUCTS (UNITED KINGDOM REQUIREMENTS)

Suction Pads for Packaging

UNSIGNED HARDCOPY NOT CONTROLLED

Following this guideline enables proper treatment of the relays during the critical phase in the relay life.

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

SUNCOURT RADON FAN MODEL: RDN04 & RDN04-3, RDK04 & RDK04-3 INSTALLATION INSTRUCTIONS

Bag Sealers Vacuum Sealers Vacuum Chambers Band Sealers Medical Packaging Flow Wrappers

SECTION (15530) - REFRIGERANT PIPING

EVERLIGHT ELECTRONICS CO.,LTD.

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Technical Data Sheet. Pb Free. Specification NB104 SSC. Customer. Rev. 03 July 서식번호 : SSC- QP (Rev.0.

Addendum Instruction Manual

Contents. 1. Performance Characteristics 2. Configuration Characteristics 3. Specialty Characteristics 4. Technical Parameters

Fisher Scientific Model 281A Vacuum Oven. Installation and Operating Manual Rev. 0

Presenter: Malcolm McLaughlin Date: 04/04/2019. A Review of Medical Device and Optical Critical Cleaning

SMARTREPEL HYDRO AM. Fluorine-free repellents. Public, Smartrepel Hydro Georg Lang, Textile Specialties Business, /

SK68XX SIDE SPECIFICATION INTEGRATED LIGHT SOURCE INTELLIGENT CONTROL OF CHIP-ON-TOP SMD TYPE LED

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Vertical Centrifugal Coater VCC

FSS-Series Heavy-Duty Flat panel Emitter Electric Overhead Infrared Heaters

Optimizing Continuous Deodorization for Quality and Energy

INSTRUCTIONS FOR CLEANING AND STERILISING HUMECA MEDICAL EQUIPMENT FOR BOTH ELECTRIC AND MANUAL DEVICES

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Transcription:

3.1.1 a. Handle PP + resin-coated films with gloves only at the edges a. Reseal opened PP bags b. Store PP + and resin-coated films at < 23 0 C and < 50% of humidity c. Acclimate PP + resin-coated films if storage temp. is less than room temperature. d. Process control (storage, place of use, transport route) via temperature and moisture indicators a. Handle such that adverse effects on product quality and functionality are prevented. b. Only if climate of storage room is not controlled. c. Storage conditions must be agreed or qualified with the manufacturer of the material. d. Any existing temperature differences should taken into account in qualification. e. Monitor room climate via temperature and moisture indicators. 3.1.2 Do not mix different resin types Material storage should be organized accordingly. 3.2.3 Brief period between drying and pressing (moisture absorption). Before packaging/equipping, remove moisture. 3.2.3.2 Determine the degree of moisture of the etched cores according to TM 650, Method 2.6.28. Insert cores separately, dry at 105 0 C for 30 min. Drying of stacked cores: Max. height: 25.4 mm Temp. stack center: 105 0-120 0 C Time: 2 hours. Any residual moisture that may be present should be evaluated during qualification. In interim storage, ensure low absorption of moisture. Page 1/5

3.2.3.3 Item 3.2.3.2 also valid for multiply pressed PCBs. In interim storage, low absorption of moisture should be ensured. Drying: 180 0 C - 2 hours or 150 0 C - 8 hours or 120 0 C - 24 hours 3.3.2 Handle pressed panels/pcbs with gloves. Avoid fingerprints by using suitable methods. 3.3.3 Monitoring of temperature and moisture during the processes. Drying prior to plating and LSL. The process parameters should be defined such that adverse effects are prevented. 3.3.6 Moisture 0.1 to 0.5 %, based on the resin weight. Drying of the PCBs by the manufacturer: -> Artificial aging of the soldering surface -> Impairment of solderability/storage time. It is recommended to carry out the drying process immediately prior to the soldering process. 3.4.4 Drying temperatures according to Table 3-1 Individual definition of the drying conditions through type-specific qualification at the end user. Page 2/5

4.1.1. Dry polyamide material prior to packaging. For packaging, use: - Vacuum-sealed moisture barrier bags - Moisture indicators - Desiccants. Drying of the PCBs by the manufacturer results in: -> Artificial aging of the soldering surface -> Impairment of solderability/storage time. It is recommended drying them immediately prior to equipping. 4.1.2 Include rigid reinforcement sheet when packaging: - Thin PCBs (< 1.40 mm) - Flexible PCBs - PCBs with complex milling pattern. To avoid mechanical impact, a suitable packaging should be selected. 4.1.5 Packing material ESD-compliant. Which packaging material is used, should be agreed between user and supplier. ESD-compliant packaging for bare PCBs is price-relevant. 4.2.1 Water vapor penetration rate of the packaging: 0.002 mg / 100 inches 2 / 24 hours Which packaging material is used, must be agreed between customer and PCB manufacturer. 4.2.2 Use a packaging material with metallic interlayer, in particular for lead-free PCBs (moisture). Which packaging material is used, must be agreed between customer and PCB manufacturer. 4.2.3 and 4.2.4 Desiccant and moisture indicators according to -J-STD-033. Qualification must be agreed between customer and supplier. Page 3/5

4.2.5 Determination of moisture by "laminate test coupons". Who provides the coupons must be agreed between supplier and customer. 4.3.1.2 Use sulfur-free and ph-neutral packaging material for chem. Ag. Use a packaging material that does not have any adverse effects on solderability / storage time. 4.3.1.3 When vacuum sealing, do not remove air completely. The function of the desiccant will be impaired. 4.3.1.4 Include a desiccant in the moisture barrier bag next to the PCBs. 4.3.1.5 For PCBs 144 inches 2 (0,09 m²) = 25 PCBs / delivery unit per package. For PCBs > 144 inches 2 (0.09 mm²) = 10 PCBs / delivery unit per package. The degree of vacuum must have been optimized by the PCB manufacturer: - To achieve mechanical stability of the packaging - To achieve good functionality of the desiccant. No adverse effects caused by the positioning of the desiccant on: - Solderability - Effectiveness of the desiccant - Mechanical impact on the PCBs. The addition of desiccant should be agreed between supplier and customer. The number of PCBs in a packaging unit depends on the PCB size, PCB thickness and the structure of the circuit. The supplier should establish a suitable package size. Page 4/5

4.4.2 The package of ESD-sensitive printed circuit boards should be labeled according to ANSI, including ESD protection symbol. Which packaging label is used, must be agreed between customer and PCB manufacturer. 4.4.3 PCBs contained in dry packaging should bear a label referring to moisture or the symbol shown below. Which packaging label is used, must be agreed between customer and PCB manufacturer. 5. Goods receipt, storage and equipping of printed circuit boards Does not affect manufacturers of bare printed circuit boards Page 5/5