SliverLED Round Downlight, 1 Regress SR11

Similar documents
USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

USAI ADJUSTABLE. Lighting

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

SliverLED Round Adjustable, Wet Location SR21W

PROJECT INFORMATION PROJECT

80 Watts FLANGE FINISH

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

PROJECT INFORMATION FLANGE FINISH

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

Field changeable between Trimmed / Trimless / Millwork

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

DATE TYPE 40 DELIVERED PERFORMANCE

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

NanoLED NXT Cylinder LNRP3 Surface

OPTIONAL LENS 2 FLANGE FINISH

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

PROJECT INFORMATION PROJECT DATE TYPE

BeveLED 2.1 PROJECT INFORMATION

Field changeable between Trimmed / Trimless / Millwork

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

BeveLED Cylinder LBRP6 Surface

True Zero Conceal - Z3SA-C 3 Square Adjustable

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

1" Regress Trim DELIVERED PERFORMANCE - Downlight

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

BeveLED Cylinder LBRP6 Pendant

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

BeveLED Mini Trimless Acoustical - B3RDP

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3SD 3 Square Downlight

BeveLED Mini - B3RA 3 Round Adjustable

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

BeveLED Mini - B3RD 3 Round Downlight

BeveLED Cylinder LBRP6 Surface

Micro Wall Wash Trimless - MWL

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

IHOL-4DR / IRD400 4 Gravity LED Downlight

ELEMENT LED Dimmer Compatibility Testing

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Grüv Flare Regressed. Recessed Linear LED

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Classix 6" 6" Round Adjustable C3M

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Classix 6" 6" Round Lens Wall Wash

Evoke Square Downlight

Evoke Square Adjustable HP

IHOL-6DR / IRD600 6 Gravity LED Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Hornet HP. Round Glass Downlight

Grüv Flare Regressed. Recessed Linear LED

Classix 6" 6" Round Adjustable C3

Evoke Square Downlight

LIGHT CHANNEL TRIM 1.6

Performance Chart Electrical Data

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Essenza. Square Downlights

Essenza. Round Downlights

Evoke Square Adjustable HP

Evoke Round Adjustable C3

PROJECT DATE FLANGE FINISH

Classix 6" 6" Round Lens Downlight

Evoke Square Adjustable C3M

Transcription:

Sliver Round Downlight, 1 Regress SR11 SLIVER DOWNLIGHT usailighting.com/sliverled Sliver provides a true point source solution where previously only halogen and metal halide sources would do. As the highest performing recessed downlight with a 1-3/4 aperture and low glare, Sliver matches the look and feel of well-loved legacy light sources with all of the modern efficiency and lifetime benefits of. Now available in more light outputs, with Warm Glow Dimming, IC-rated housings, and a field-paintable primer finish option, Sliver is ideal for residential, hospitality, and restaurant settings. FEATURES Smooth, low profile trim available in factory painted finishes of white, black, bronze, and metallic grey. Field-paintable primer finish and custom RAL colors also available. Overlap flange trims are compatible with sheetrock, ACT, wood/millwork, and many other ceiling materials up to 1 thick. Optional spackle collar accessory available for flush-mount, mud-in installation in sheetrock. Narrow IC-Rated housings can squeeze between 12 on center joists Industry leading illumination and craftsmanship SLIVER DOWNLIGHT PERFORMANCE DATA COLOR CHOICES Classic White Warm Glow Dimming DELIVERED* PERFORMANCE: 9W BAFFLE BAFFLE 15W BAFFLE BAFFLE 16W BAFFLE BAFFLE Color Rendering Index: Source Lumens: 1100 950 1100 950 1600 1400 1600 1400 900 625 900 625 Lumens Per Watt: 71 62 55 48 71 62 55 48 38 27 29 21 Delivered Lumens: 675 575 500 450 975 850 750 650 600 425 475 325 *Performance data based on 3000K CORRELATED COLOR TEMPERATURE 2700K Classic White 3000K 3500K 4000K 2700K Warm Glow Dimming 3000K Color Rendering Index: 80+ Multiplier for Lumen Output: 0.93 0.81 1.00 0.87 1.07 0.87 1.07 0.94 0.67 1.00 0.70 Page 1 usailighting.com Patents pending., Sliver, Warm Glow Dimming and Color Harmony are registered trademarks of, LLC Revised 12/26/2018

Sliver Round Downlight, 1 Regress SR11 SLIVER FAMILY TRIMS DOWNLIGHT SR11 TRIM DIMENSIONS SR11 1 Regress SR41 1/4 Regress SS11 1 Regress SS41 1/4 Regress 1/16" 1" Regress ADJUSTABLE Trim Finish Baffle Finish SR21 SR21W Wet Location SS21 SS21W Wet Location 1 3 4 Ø 3 15 16 Ø SCR2- ROUND SPACKLE COLLAR ACCESSORY WALL WASH 3 9 16 Ø 7" Ø For flush-mount installations, order spackle collar accessory SR51 SS51 SLIVER SPECIFICATIONS FIELD REPLACEABLE LIGHT ENGINE is serviceable through the aperture with a Philips screwdriver. All light engines feature industry-leading color consistency. Classic white light engines maintain perfectly white light in all conditions. Warm Glow dimming light engines gradually shift color to a warm 2200K when dimmed, indistinguishable from incandescent. FIELD REPLACEABLE DIMMING is serviceable from below the ceiling through the aperture. 0-10V, 100%-1% DIML6E dimming driver provided standard. Each solid state electronic constant current driver has a high power factor and sources 2mA. Drivers comply with IEEEC62.41 surge protection. Other dimming drivers optionally available. Some on-time delay may be experienced depending on control system used. EMERGENCY Emergency lighting battery pack with remote test switch requires above ceiling access. IOTA ILB-CP07 provides 7W of backup power for 90 minutes. Wet location option also available. EM not available with IC housings. Emergncy Mode Performance* 9W 15W 16W Multiplier for Lumen Output in EM Mode 0.92 0.63 0.55 *apply to delivered performance WEIGHT Standard housing with trim weighs 5.5 lbs, emergency housing with trim weighs 8 lbs. 9W IC housing weighs 6.5 lbs, and 15W/16W IC housing weighs 10 lbs. HOUSING Universal housing style allows the ability to swap trim styles between Downlight, Adjustable and Wall Wash. Fabricated of 18 ga. black powder coated steel with thru wire J-box, 2 in 2 out at min. 90 C, #12 AWG thru branch circuit wiring. IC housings are rated for direct contact with insulation up to R30 or less. MOUNTING Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14 to 24 centers. Channel bars optionally available for dropped ceiling installation. CEILING CUT OUT 3-5/8 Ø LISTINGS Dry/Damp/Wet. NRTL/CSA-US Tested to UL Standards. IBEW Union made. NC housing is UL2043 rated for use in Air Handling Plenum. WARRANTY Based on IESNA LM80-2008, Sliver has a 50,000 hour rated life at 70% lumen maintenance (L70). Warranty covers replacement parts for 5 years from date of shipment. NOTES Not for use in corrosive environment Use spackle collar accessory for flush-mount, spackle-in sheetrock applications Interior use only. PHOTOMETRICS Consult factory or website for IES files. Tested in accordance with IESNA LM79. /sliverled Page 2 usailighting.com Patents pending., Sliver, Warm Glow Dimming and Color Harmony are registered trademarks of, LLC Revised 12/26/2018.

HOW TO SPECIFY Sliver Round Downlight, 1 Regress SR11 TRIM ORDERING INFORMATION SR11 S Sliver Downlight Baffle Finish Wattage Color Temperature Beam Lens Trim Finish Classic White SR11 Sliver Round Downlight, 1 Regress WH White BL Black X109 9W Module X115 15W Module 27KS 2700K, 80+ CRI 30KS 3000K, 80+ CRI 35KS 3500K, 80+ CRI 40KS 4000K, 80+ CRI 27KH 2700K, 90+ CRI 30KH 3000K, 90+ CRI 35KH 3500K, 90+ CRI 25 25 beam 35 35 beam 50 50 beam S Solite (provided standard) WH White BZ Bronze BL Black GR Metalized Grey PR Primer FInish RAL Custom Color (specify RAL#) Warm Glow Dimming 16 WG1 16W Module 2722KS 2700K, 80+ CRI 3022KS 3000K, 80+ CRI 2722KH 2700K, 90+ CRI 3022KH 3000K, 90+ CRI HOUSING ORDERING INFORMATION ACCESSORIES SV Product Wattage Housing Voltage Dimming Driver EM Accessory Classic White SV Sliver X109 9W Module X115 15W Module Warm Glow Dimming 16 WG1 16W Module NC New Construction Mounting Pan IC Insulation- Contact Rated / Airtight UNV For use with Universal Voltage 120V - 277V D2 0-10V dim, 10% (1) D4E Lutron 5 ECO, 5% (1, 2) D4H Lutron H ECO, 1% Fade (1,2) D6A Eldo 0-10V, 0.1%, logarithmic/lutron controls (1) D6B Eldo 0-10V, 0.1%, linear controls (1) D6E Eldo 0-10V, 1%, logarithmic/ Lutron controls (provided standard) D6F Eldo 0-10V, 1%, linear controls D7 Eldo DALI, 0.1% (1) EM Emergency Battery EMW Emergency Battery Wet Location EM not available with IC housings CB27 27 C-Channel Bars CB52 52 C-Channel Bars SCR2 Round Spackle Collar Accessory for flush mount installation in sheetrock 3 9 16 Ø 7" Ø 120V For use with 120V only D3 Lutron Hi-Lume 1% 2-wire, 120V only D19 Phase dimming 1%, 120V only (2) 1 Not Available with X109 2 Not available with 16W Warm Glow Page 3 usailighting.com Patents pending., Sliver, Warm Glow Dimming and Color Harmony are registered trademarks of, LLC Revised 12/26/2018

Sliver Round Downlight, 1 Regress SR11 SLIVER HOUSING FROM New Construction Housing - NC * Nailer bars are provided standard Maximum ceiling thickness = 1 Insulation Contact Rated - IC Airtight (9W) * Nailer bars are provided standard Maximum ceiling thickness = 1 Insulation Contact Rated - IC Airtight (15W & 16W) * Nailer bars are provided standard Maximum ceiling thickness = 1 4-1/8" 5" 6-3/4" 1" 1" 1" 4-1/8" 8-1/2" 4-1/8" 8-1/2" 4-13/16" 11-1/4" 7-5/8" 7-5/8" 10" 12-5/8" 16-1/8" 12-5/8 16-1/8 16" 19-5/8 New Construction Emergency - EM * Nailer bars are provided standard Maximum ceiling thickness = 1 5-1/2" 1 4-1/8" 8-1/2" 9-3/8" 12-5/8" 16-1/8" Page 4 usailighting.com Patents pending., Sliver, Warm Glow Dimming and Color Harmony are registered trademarks of, LLC Revised 12/26/2018

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D2 / DIML2 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) 0-10V (+) GRAY PURPLE NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) 0-10V (+) GRAY PURPLE NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D3 / DIML3 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF2-10ND-120-100% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD-10NXD- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-100%-1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE GROUND ONLY FOR SWITCHES WITH I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: D4E / DIML4E EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 5% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 5% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 5% 1 64 1 32 Lutron Quantum Various 100% 5% 1 64 1 32 DIMMING COMPATIBILITY D4E / DIML4E and D4H /DIML4H NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4E / DIML4E : Lutron 5 Series EcoSystem Driver / Dimming Driver Wiring (Dims down to 5%) * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H : Lutron H Series EcoSystem Driver with Fade to Black (dims down to 1%) D4H / DIML4H EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS E2 E1 ECOSYS BUS E2 E1 WALL CONTROL PURPLE GRAY PURPLE I2-264-4EH Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V DIMMING (NO RELAY) CLASS 2 CONTROL WIRES DIMMER: 0-10V RELAY 0-10V (-) 0-10V (+) GRAY PURPLE GROUND DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) 0-10V (+) GRAY PURPLE DIMMER: 0-10V w/ POWER SWITCHING DIML6A, 6B 0-10V DIMMING (NO RELAY) I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D7 / DIML7 and D7E NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D19 / DIML19 NOTES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D19 / DIML19 : Hatch XTC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE GROUND ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification Lutron S-600P sheet to determine S-603P number of fixtures DV-600P per dimmer. Max number DV-603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Manufacturer Product Qty Fixtures Per Dimmer Leviton 6615 Use fixture wattage per IPE04-xxx fixture specification Lutron NTELV-300 sheet to determine NTELV-600 number of fixtures SELV-300P per dimmer. Max number SELV-303P of fixtures is limited by DVELV-300P dimmer load rating. DVELV-303P I2-264-19 Revised 03/22/2017