User Manual for model

Similar documents
User Manual for model RK 18 RK 25 RK 34 CE 0694 RK 18_25_34 - RAD - ING - MAN.UT A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

User Manual for model

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

E-COMBI EVO E-SYSTEM EVO

USERS MANUAL FOR GAS BOILERS

RKA 24.8_24_28_34 - RAD - ING - MAN.INST A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD

E-Combi One E-System ONE

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

/2010 US/CA

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

GB24 & GB30. User Manual

WHE 2.24 / WHE 2.24 FF

USER GUIDE VOGUE MAX SYSTEM

The guarantee on this appliance is valid for 12 months from the first day of installation.

USERS GUIDE 24, 30. For installation guide see reverse of book

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

USER GUIDE LOGIC HEAT H

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...

Logic+ Combi

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2017/09) en

ir-range 8G /03.15 Changes reserved.

User's Instructions. Alpha CB50

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Residential Gas Condensing Boiler Greenstar combi 100 p / 151 p ZWB28-3A... ZWB42-3A...

End User Manual ACO 35 MFFI COMBI

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Operating instructions

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

Combi Eco Elite Range. User s Guide and Important Warranty Information

Operating instructions

CONTROL CABINET for cascade boiler systems

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Service & Trouble Shooting Manual

USER'S INFORMATION MANUAL

USER'S INFORMATION MANUAL

INSTALLATION AND MANINTENANCE INSTRUCTIONS

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

TAHITI CONDENSING KR 55 - KR 85

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

User s Information Manual

Installation and Servicing Instructions RHA 28. Gas Fired, Condensing Boilers with Storage Cylinder CE 0694 SEDBUK BAND B TG05A062.

CE 0694 RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY

INSTRUCTION FOR THE USER THC V E OIL BLU

A/23 MFFI - A/27 MFFI

Baxi Maxflow Combi WM

INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS BG 2000-S (V13) RU PL DE IT ES NL EN 1 662Y0600 A

Servicing Instructions Type C Boilers G.C.N: LEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER

USER'S INFORMATION MANUAL

DOMESTIC HOT WATER Follow operational sequence

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

iheat 25c iheat 30c iheat 35c

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

Divacondens D Plus Atmospheric condensation wall-mounted boilers, with instant domestic hot water production

INSTALLATION, AND MAINTENANCE MANUAL FOR GAS FIRED, ONLY HEATING WALL-HUNG BOILERS (SYSTEM BOILERS)

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

MURELLE EV HE 25/55-30/55

24CDi, 28CDi & 35CDi II COMBI

Open Vented Condensing Boilers

Wall-hung gas boilers. Instructions for use. English 31/08/05

USER'S INFORMATION MANUAL

95M-200. Gas-Fired Direct Vent Modulating Hot Water Boiler. Control Manual And Troubleshooting Guide. P/N , Rev.

User manual. Logano GC 124 II. Gas boiler

Baxi Maxflow Combi FS

PROGRAMMABLE 7-DAY THERMOSTAT

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

LIBRA DUAL INSTALLATION USE AND MAINTENANCE. Italian product. High quality IST 04 C

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Operating instructions

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

INSTALLATION, USE, AND MAINTENANCE MANUAL FOR GAS FIRED, WALL-HUNG BOILERS WITH DOMESTIC HOT WATER STORAGE CYLINDER

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

Planet Super4F.S. User Instructions

USER'S INFORMATION MANUAL

Operating instructions

Service booklet for the Engineer for Gas Condensing Boilers

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty


Operating instructions

DTG Eco / V130

Mikrofill Ethos Condensing combination boiler

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

BOSCH CONDENS 5000W ZSB18-2A

Oil TRIANCO. EuroStar Range BURNER DETAILS TRIANCO - OIL BURNER. To be retained by householder

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

Servicing manual. 600 Series - 11S / 19S / 24S / 24C. Wall-mounted condensing gas boiler. For trade use

Servicing manual. Wall-mounted condensing gas boiler 600 Series - 11S / 19S / 24S / 24C /2002 GB(EN) For trade use

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Transcription:

User Manual for model RKA 24/8 RKA 24 RKA 28 RKA 34 Wall mounted storage combi boiler premix condensing boiler User instruction CE 0694 RKA 24.8_24_28_34 - RAD - ING - MAN.UT - 1104A - DIGITECH 2 - REGNO UNITO - EXTRAHEAT - CBD Technical specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

TECHNICAL CHARACTERISTCS BOILER OPERATING INSTRUCTIONS Make sure that the authorised technician who tested the boiler has stamped the guarantee booklet. The installation, first start-up, regulation and maintenance operations must be carried out exclusively by qualified personnel (e.g. Radiant authorised Service Centres). Incorrect installation can cause damage to property and injury to persons or animals, for which the manufacturer will not be held responsible. During the installation, the technician must carry out the following checks: The data on the data plate must correspond to that of the mains supply networks (gas, electricity, water). The boiler must be regulated according to its designed use and performance. The flue gas exhaust and combustion air intake system must be correctly installed and operational. The exhaust gas discharge and ventilation systems must comply with the requirements of national and local standards regardless of whether the boiler is installed indoors, outdoors or in its own cabinet (see section Reference standards. General warnings If there is any doubt as to whether the appliance has been tested by an authorised technician, do not attempt to start it. All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL, registered in accordance with current legislation. Make sure that the requirements relating to the air intake and ventilation of the room in which the boiler is to be installed have been complied with. The boilers can be installed outdoors in a partially protected location, in accordance with current standards and where the minimum external temperature does not fall below 10 C. The manufacturer will not be held responsible for installation in locations where the temperature falls to below 10 C. The boiler is fitted with an antifreeze system. If the boiler is installed in a location where there is a risk of freezing, the anti-freeze system will only come into operation if the power is on and the gas supply valve is open (the frost protection is active even with the ON/OFF switch in OFF position). The manufacturer will not be held responsible for damage to the boiler caused by non-compliance with this instruction. Should any part of the boiler freeze-up, do not attempt to light it under any circumstances, but instead call the Service Centre immediately. The Benchmark Book is an integral part of an installation. The Benchmark handbook should be filled-in each time a boiler is installed. In addition to checking the combustion, all ordinary and extraordinary maintenance operations must be reported in the booklet together with the name of the person carrying out the maintenance and, where applicable, his company. The appliance s combustion system must be checked every two years. This check includes testing the efficiency of the boiler and must be carried out by authorised personnel possessing the qualifications as required by current law. Do not obstruct the ventilation openings in rooms where there are gas-burning appliances installed (boiler, cooker, etc.). If you smell gas DO NOT ACTIVATE ANY ELECTRIC SWITCHES, TELEPHONES OR ANY OTHER DEVICE THAT MAY GENERATE ELECTRICAL DISCHARGES OR SPARKS. OPEN DOORS AND WINDOWS IMMEDIATELY TO CREATE A CURRENT OF AIR THAT WILL RAPIDLY CLEAR THE ROOM. CLOSE ALL GAS TAPS AND VALVES. CALL FOR PROFESSIONALLY QUALIFIED PERSONNEL. 1

TECHNICAL CHARACTERISTCS Boiler controls - Control panel LEGEND 1. ON/OFF SWITCH 2. HEATING TEMPERATURE CONTROL KNOB 3. D.H.W TEMPERATURE CONTROL KNOB. 4. D.H.W TEMPERATURE BUTTON. KEEP PRESSED FOR 5 SECONDS TO DISPLAY OUTSIDE TEMPERATURE (ONLY WITH OPTIONAL OUTDOOR SENSOR) 5. SERVICE BUTTON. 6. SUMMER, WINTER OR SUMMER/WINTER MODE SELECTION BUTTON. 7. TERMINAL BOARD FOR EXTERNAL WIRING. 8. TEMPERATURE, ERROR CODE AND OPERATING STATUS DISPLAY 9. TIME CLOCK (optional) 9 8 Fig. 1 1 2 3 4 5 6 7 2

USER INSTRUCTIONS Starting - up the boiler Open the gas Isolation valve located under the boiler. Switch on the boiler by placing the ON/OFF switch (1) in the ON position (see Control panel ). The boiler will light automatically (with the WINTER mode selected and room thermostat connected). Check that there are no flashing numbers on the display 8 (see error codes). If code H2O appears on the display 8 this denotes that there is no water in the boiler. Consequently, fill the system as described in section Filling the system. 9 8 Fig. 1 1 2 3 4 5 6 7 WINTER mode To switch boiler operation to WINTER mode, press button 6 (see fig. 1). The boiler will only work for the central heating system. The WINTER mode setting of the boiler is signalled by the symbol lit continuously on the control panel. The automatic ignition system will light the burner every time there is a demand for room heating. In this case, the symbol on the control panel will flash. SUMMER-WINTER mode To switch boiler operation to SUMMER/WINTER mode, press button 6 (see fig. 1). The boiler will work for both central heating/d.h.w systems. The SUMMER/WINTER mode setting of the boiler is signalled by the symbols lit continuously on the control panel. The automatic ignition system will light the burner every time there is a demand for room heating or domestic hot water, the functioning is signalled by the symbols flashing continually on the control panel. Regulating the heating temperature The heating temperature is regulated by knob 2 (see fig.1). Rotating the knob anticlockwise reduces the temperature. Rotating the knob clockwise increases the temperature. The range of temperature settings for the central heating runs from a minimum of 30 C to a maximum of 80 C, or, in the case of low temperature operation, from a minimum of 25 C to a maximum of 59 C. D.H.W temperature control The domestic hot water temperature is regulated by knob 3 (see Control panel ). Rotating the knob anticlockwise reduces the temperature. Rotating the knob clockwise increases the temperature. The range of temperature settings for the domestic hot water runs from a minimum of 35 C to a maximum of 60 C. 3

USER INSTRUCTIONS Topping-up the system with water The water pressure in the central heating circuit must be checked during the entire period of operation of the boiler. In this respect, the reading on the pressure gauge M (see fig. 2), located on the lower part of the boiler, must not be less than 1 bar. If there is insufficient water in the boiler, the code H2O will flash on the display (see Control panel ). To bring the system back up to pressure, open the external filling loop valve (see fig. 3) and use the pressure gauge M (see fig. 2) to check that the system pressure reaches 1 bar and that the code H2O lights up. When the operation is complete, close the fill valve. Fig. 2 M Diagnostics Error codes: HF This paragraph contains a list of error codes that the boiler may generate on the display 8 (see Control panel ) together with the relative indications and the operations that the user can carry out to reset the boiler. If the problem re-occurs after the following actions have been taken, call an authorised Service Centre. CWI OPTIONAL _E01 E01_ Ionisation block Code E01 lit continuously on the display. Fig. 3 12-00710 Check that the gas valve on the boiler and gas meter are open and that there is gas in the mains supply (or in the tank). Switch off then switch on the appliance using switch 1 (see Control panel ) on the control panel. When the error code on the display disappears, the boiler will restart. If the problem persists, Call the Service Centre. _E02 E02_ Safety Thermostat tripped Code E02 lit continuously on the display. Call the Service Centre. _E03 E03_ Flue Gas Thermostat tripped Code E03 lit continuously on the display. Call the Service Centre. _h2o h2o_ Water Pressure Switch tripped Code H2O lit continuously on the display. Check the water pressure in the central heating circuit. The reading on the pressure gauge M (see fig. 2), located on the lower part of the boiler, must not be less than 1 bar. If the pressure is less than 1 bar, top-up the system as described in paragraph Filling the system. The boiler will restart automatically. If the problem persists, Call the Service Centre. 4

USER INSTRUCTIONS _E05 E05_ Heating Sensor malfunction Code E05 lit continuously on the display. Call the Service Centre. _E12 12_ D.H.W Storage Cylinder Sensor Malfunction Code E12 lit continuously on the display. Call the Service Centre. _E16 E16_ Electric Fan Malfunction Code E16 lit continuously on the display. Call the Service Centre. _E22 E22_ Parameter programming request Code E22 lit continuously on the display. Call the Service Centre. _E35 E35_ Flame Detection Malfunction Code E35 lit continuously on the display. Call the Service Centre. N.B. If the boiler is to be left unused for a long period of time, the user must do one of the following: Make the boiler safe by disconnecting all the power supplies (electricity and gas), and draining the heating system and the condensate trap. Leave the boiler in standby, leaving the electricity and gas supplies connected and, consequently the anti-freeze function. 5

extraheat Limited Belmayne House Clarkehouse Road Sheffield S10 2LN South Yorkshire Phone Number 0844 3814115 Fax Number 01142 309147 E Mail: radiantboilers@extraheat.co.uk radiantcustomersupport@extraheat.co.uk Website: www.radiant.eu THE TECHNICAL DATA AND MEASUREMENTS ARE PROVIDED FOR INFORMATION PURPOSES ONLY AND ARE NOT BINDING. THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION. NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION ERRORS. E+OEALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED, MEMORISED IN ANY FILING SYSTEMS OR TRANSMITTED IN ANY FORM WHATSOEVER, INCLUDING ELECTRONIC, MECHANICAL, PHOTOCOPIES, RECORDINGS OR ANY OTHER MEANS WITHOUT THE COMPANY S PRIOR WRITTEN APPROVAL.