Established /10/2015. Doran Pruisner Dan Wood

Similar documents
Iowa State Fire Marshal

Agency for Health Care Administration

Agency for Health Care Administration

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

B. The Facility Emergency Planners and Alternate Planners will successfully complete the in-house DJJ Fire Prevention course.

School Fire Safety Checklist

Skilled Healthcare Documentation Requirements Life Safety and Fire Protection

GENERAL AREAS OF INSPECTION

Agency for Health Care Administration

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

IRVING FIRE DEPARTMENT EMERGENCY PLANS

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

FIRE FIRE FACT NO. 057 CHECKLIST(s) : Rev. 11/2006 TITLE : CHILD CARE HOMES CHECKLIST ITEM(s) : REFERENCE(s) : K.S.A

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Plan Review Check List Fire Alarm System

FIRE SAFETY AND PREVENTION POLICY

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

EMERGENCY PLANNING AND PREPAREDNESS

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Fire/Life Safety Policy

Fire Safety Plan FOR. Business/Property Name: Address: Phone Number: Occupancy Classification. Approved by Fire Inspector: Date:

ICC CODE CORNER 2015 International Fire Code

Building and Grounds Self-Inspection Program

Denver Fire Department Fire Prevention Division

GUIDELINES FOR EMERGENCY PLANNING AND PREPAREDNESS. High-Hazard

COMPLIANCE WITH THIS PUBLICATION IS MANDATORY

PRINTED: 06/09/2017 FORM APPROVED CENTERS FOR MEDICARE & MEDICAID SERVICES OMB NO (X2) MULTIPLE CONSTRUCTION A. BUILDING 03 - A BUILDING

LIFE SAFETY & FIRE PREVENTION MANAGEMENT PLAN

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

Emergency Planning for Institutional Facilities

Johnson County, Kansas. Home Daycare Handbook 2013 Edition

CODE TECHNOLOGIES COMMITTEE NURSING CARE FACILITIES WORK GROUP APPROVED CODE CHANGE DRAFTS CODE GROUP B

Procedure DESCRIPTION/OVERVIEW

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

Rental Housing Inspection Guide

Life Safety Code Common Discepancies Course# LSC102. EZpdh.com All Rights Reserved

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

Facility Manager Training

Fire Inspection Program

Life Safety Codes for Assisted Living Facilities

Building Self-Inspection Program

Written Fire Safety Plans

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

Residential Based Care Facility Guidelines

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

EMERGENCY PLANNING AND PREPAREDNESS

FIRE SAFETY LOGBOOK ADDRESS OF PREMISES NOMINATED RESPONSIBLE PERSON

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

Building, plumbing, and fire safety requirements.

Agency for Health Care Administration

NFPA 101, 2012 EDITION IMPACT ON NEW AND EXISTING HEALTH CARE FACILITIES

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

FIRE & LIFE SAFTEY STANDARD

Fire Safety, Risks, & Response at Jackson Health System JHS Annual Mandatory Education

2018 IFC Update. Based on the 2018 International Fire Code, (IFC ) Goal. Objectives. Content

Temporary Haunted Houses

THE TOWNSHIP OF CRANBURY

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Fire & Life Safety Code Compliance. Common Safety Deficiencies and Tips for Compliance for Long Term Care and Skilled Nursing Facilities

Principal s Guide for Fire Safety Planning in Schools. To be kept in School Administration Office

Assisted Living Facilities

Residential Care Facilities Requirements

a Sigma Nu Evacuation Plan Willard Way, Ithaca, NY Assembly areas: Great Hall, Tube Room, Dining Hall, Dormer, and Chapter Room

Recent Revisions and Proposed Key Changes to Fire Code

FINLEY HALL EMERGENCY EVACUATION PLAN

NFPA CODE TESTING & INSPECTION. Requirements & Recommendations for. Licensed Florida Hospitals, Ambulatory Surgery Centers,

March 2015 (reprinted from March 2008 issue)

Patrick County Horizons Jeb Stuart Hwy. Stuart, Va

Family Foster Home Fire Safety Evaluation Checklist Instructions

Bold items are particular to the City of Euless

Fire Inspection FAQ s

DCSS (ACB) Data Center Fire Suppression Procedures

Interim Life Safety Measures. Healthcare Construction Certificate - Level 1

Black Diamond Fire Department Building Owner s Responsibilities for Fire Safety Equipment

Fire & Life Safety Practices

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Board Policy 6819 Fire Safety and Prevention Plan

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Large Family Daycare Guideline

The blank report forms are enclosed. If additional blank forms are needed you may contact my office at (210) and ask for Maria Castoreno.

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

Report on First Revisions with Statement June 2014 NFPA 101

Fire Safety Requirements for Peer Review

FIRE PREVENTION, MAINTENANCE AND EVACUATION POLICY AND PROCEDURES

Agency for Health Care Administration

McNary Hall Emergency Evacuation Plan Written: September 17, 2009

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

System Test Report CLEAN AGENT

Purpose: To establish procedures for identifying fire hazards and preventing fires. Scope: All Central New Mexico Community College (CNM) Community.

This policy may also be used for routine work orders that are Life Safety in nature and cannot be completed within 45-days.

Level I Chapter 1 Worksheet

Chapter 43, Building Rehabilitation allows for degrees of compliance based on the work category such as the extent of work.

Agency for Health Care Administration

Life Safety Code Potpourri

Agency for Health Care Administration

Transcription:

Established 1911 Doran Pruisner Dan Wood The International Fire Code, 2009 Edition shall apply to all occupancies except for those that are explicitly excluded by these provisions. 1

Buildings built between 1997 & June 30, 2000 1994, Life Safety Code Buildings built between July 1, 2000 & June 30, 2003 2000, Life Safety Code Buildings built between July 1, 2003 & Dec. 31, 2009 2003, Live Safety Code Buildings built after January 1, 2010 2009, International Fire Code January 1, 2010 the State Fire Marshals Office adopted the 2009 International Fire Code as the code for all facilities (except health care) as the enforcement code for the State of Iowa. Fire safety, evacuation and lockdown plans and associated drills shall comply with the requirements of Sections 404.2 through 404.5.1 IFC 2009 edition. This includes: The fire evacuation plan The fire safety plan Lockdown plans (Initiation, Accountability, Recall, Comm.) Maintenance (Updated annually or with change of staff) Availability (Location of the evacuation plan) Distribution (To tenants and employees) 2

1. Identity of the person conducting the drill. 2. Date and time of drill. 3. Notification method used. 4. Staff members on duty and participating. 5. Number of occupants evacuated. 6. Special conditions simulated. 7. Problems encountered. 8. Weather conditions when occupants evacuated. 9. Time required to accomplish complete evacuation. IFC 408.5.1 Fire safety and Evacuation Plan- The fire safety and evacuation plan required by Section 404 shall include special staff actions including fire protection procedures necessary for residents and shall be amended or revised upon admission of any resident with unusual needs. 408.5.2 Staff Training- Employees shall be periodically instructed and kept informed of their duties and responsibilities under the plan. Such instruction shall be reviewed by the staff at least every 2 months. A copy of the plan shall be readily available at all times within the facility. 3

408.5.3 Resident training Proper actions to be taken in case of fire or other emergencies (tornado, flood, wandering). Actions to be taken if the primary escape route is blocked. Fire prevention (smoking policy, furnishings). How and when to assist each other without incurring additional personal risk. IFC 408.5.4 Drill Frequency - Emergency evacuation drills shall be conducted at least 6 times per year, two times per year on each shift. Twelve drills shall be conducted in the first year of operation. Drills not required to comply with the time requirement of Section 405.4. Public Safety [661]-405.2(b) Fire drills shall be conducted not less than 6 times per year on a bimonthly basis, with not less than 2 drills conducted during the night when residents could reasonably be expected to be sleeping. 408.5.5 Resident participation- Emergency evacuation drills shall involve the actual evacuation of residents to a selected assembly point. There are no simulated or mock drills. The facility will do evacuations. 4

Documentation needed: Fire Alarm Reports inspected annual (or ½ of devices every 6 months) in accordance NFPA 72. Sprinkler Reports inspected yearly and quarterly in accordance with NFPA 13 or 13R. Quarterly Sprinkler Inspection: NPFA 25 Inspection, Testing, and Maintenance of Water Based Fire Protection Systems Alarm devices Hydraulic Name Plate FDC connection Gauges Control Valves If you don t have a copy of NFPA 25 check with your sprinkler provider for a copy. Ansul System inspected bi-annually per NFPA 96 (Kitchen Hood and Duct). Generator maintenance report and testing under load monthly and weekly tests. Emergency Lighting testing and documentation. Test emergency lighting for 30 seconds monthly. Test emergency lighting for 90 minutes yearly. Document each for review. Fire drills from the past two years conducted not less than 6 times per year on a bimonthly basis, with not less than 2 drills conducted during the night when residents are sleeping. 661-405.2(b) Once the paperwork portion of the inspection is complete it is time for the walk through of the facility. Each inspector has their own order in conducting the facility inspection. They may start in the basement and work up or top floor and work down. They want to avoid as much back tracking as possible. 5

The inspector will want to look in the attic at all two hour wall separations for penetrations of wires, ducts etc. and that all are sealed properly. They will also look above the ceiling tile at all smoke/fire barriers for penetrations and that they are sealed. All fire/smoke doors will be checked to see that they close and latch properly 6

7

All smoke seals around door frames will be checked along with the rating of all doors in resident rooms and hazardous rooms to make sure they are the correct doors. (EX. Smoke barrier doors shall be rated at least 20min, Hazardous rooms 45 min doors) Inspectors will be checking all EXIT signs to make sure the battery back up works along with all emergency lighting. Extinguishers will be checked to make sure that they have been currently inspected and tagged according to NFPA 10. All storage rooms, mechanical rooms, public bathrooms, facility kitchen, and janitorial closets will be looked at for penetrations, storage too close to sprinkler heads etc. Emergency lighting will be checked to see if they are operable. 8

Resident rooms are considered the residents home. If no one is home at the time of the inspection it is up to the administration to allow access. If a resident is home then that resident is asked if it is okay for the inspector to enter to have a look around. If a dwelling unit has no resident then the administration will allow access during the inspection. 9

Some of the things the inspector is looking for in resident rooms is the use of extension cords, surge protectors in use for things other than computer equipment. Smoke detection and sprinkler coverage, or anything that may pose a serious risk of starting a fire. Any time work is done in the facility and there are penetrations through smoke/fire barriers make sure that those penetrations are caulked with an approved fire rated material. Fire rated caulk can be used for a penetration up to ¼ of an inch. Any penetration bigger than ¼ of an inch must be protected in accordance with an approved UL fire resistive assembly. 10

11

Make sure surge protectors are not being used for anything other than office equipment. Check for storage next to sprinkler heads. NFPA 13 states that there can t be anything within 18 of a sprinkler deflector. Check for storage around electrical panels. NFPA 70 states that there must be a 3ft clearance around all electrical panels. Periodically check to make sure all Ground Fault Circuit Interrupts (GFCI) are working properly. 12

Remove all door wedges from the facility. During winter shovel all required exit doors and all pathways leading to a public way and maintain them clear of all obstructions at all times. Maintain the Fire Department Connection free and clear of all obstructions. 13

Notify staff and residents of the fire by setting off the fire alarm. Follow your Facilities Emergency Plan. If trained on a fire extinguisher, for a small fire try to extinguish, but if you feel the fire is beyond the extinguisher evacuate and let the professionals fight the fire. Residents come first! Get them to safety! You can always replace property! 14

If your facility does have a fire after you contact the Department of Inspection and Appeals contact the State Fire Marshal Office at 515.725.6145 so we are aware of it no matter how small the fire. Contact SFM and DIA immediately. Examples: FIRE SPRINKLER BREAK FIRE ALARM SYSTEM DISABLED TORNADO DAMAGE Procedures to follow: FIRE WATCH-EVERY 30 MINUTES AND DOCUMENT. EACH PERSON ASSIGNED SHALL NOT TAKE AWAY FROM NORMAL STAFFING AND THAT PERSON IS DEDICATED TO THE FIRE WATCH NO OTHER DUTIES AND SHALL BE AWARE OF FIRE HAZARDS AND PROPER PROCEDURES TO NOTIFY REST OF STAFF AND RESIDENTS IN EMERGENCY. Who took care of deficiency. (ex. Miller Construction) When fixed. (12/23/2011) How it was fixed. (ex. Penetration repaired using 3M 2 hour rated fire caulk) 15

DORAN PRUISNER Construction/Design Engineer, Senior DIVISION OF STATE FIRE MARSHAL 515.725.6152 EMAIL pruisner@dps.state.ia.us DANIEL WOOD Fire Inspector DIVISION OF STATE FIRE MARSHAL 515.725.6171 EMAIL wood@dps.state.ia.us 16