The new Xcell EC High Efficiency Range Fresh air pure and simple

Similar documents
Sentinel Demand Energy Recovery Ventilation

Lo-Carbon Sentinel Kinetic Horizontal

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

The Sentinel Kinetic Horizontal Range

ENERGY RECOVERY VENTILATION (ERV)

CI/SfB (57.7) 2nd edition

Small Room Heat Recovery Ventilation

Lo-Carbon Sentinel Kinetic Range Overview

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Lo-Carbon Sentinel Kinetic Range Overview

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

SIMPLICITY FULL MODULARITY?

SIMPLICITY OR FULL MODULARITY?

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Simply Silent Contour 4 (100mm) Axial Extraction Fan

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

KOMFORT EC DB Suspended heat recovery air handling units

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR)

Building Regulations 2010: What it means to you.

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Panther Fan Coil Unit

External insulated volume. control damper

Fresh air unit ALB. ALB it s simple and so easy! Air supplied through a heater and filter in a single unit.

Eco Active H E A T R E C O V E R Y S Y S T E M S H Y B R I D U N I T. W: T:

Xcell 270 Longlife DC wholehouse heat recovery unit

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Xpelair Simply Silent DX150

HRXD MVHR UNIT Mechanical Ventilation with Heat Recovery.

Acoustic solution for MRXBOX95(AB)-WH1 and MRXBOX95(AB)-WM2

Xpelair Simply Silent DX100B

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

The Range HIGHEST INDOOR AIR QUALITY IN NEW HOMES

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

TopVent Design Handbook

NATURAL VENTILATION CONTROL SYSTEMS

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Our quietest bathroom fan. Fact.

Xpelair Simply Silent DX100

Xpelair Simply Silent TM Contour Fan

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

COOLflow 4E PRODUCT RANGE

Natural Ventilation Controller with 24vDC drive NVC-1204

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

TSEK VHR EC HEAT RECOVERY UNITS

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

Slimline 150 & 300 Exceptionally low energy consumption. High Efficiency, Low Profile Heat Recovery Range

TECHNICAL SPECIFICATIONS - CW-80T-TWIN AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

OPUSXBOX - SMALL COMMERCIAL HEAT RECOVERY SYSTEM LOW DEPTH, HEAT RECOVERY UNIT WITH MULTIPLE SPIGOTS AND ECOSMART CONTROLS.

INTRODUCTION Flexibility Is The Key Simple Access For Maintenance

Natural Ventilation Controller with 24vDC drive NVC-1204

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

Efficient Cooling and Heating. Flexibility Is The Key

Heat Pump Air Conditioning Systems

The new generation of MVHR units - ComfoAir Q. Always the best climate for PERFORMANCE

MRXBOX90 - WHOLE HOUSE HEAT RECOVERY UNIT

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

Zehnder Comfosystems. ComfoAir 180 Datasheet

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

Digitemp. Beyond air conditioning.

F series close control air conditioners exploit the indirect FREE COOLING system with adiabatic cooling to ensure high system energy savings.

Zehnder ComfoAir 550. Ventilation unit

Xpelair Simply Silent TM DX100 Fan

Fresh Air Ventilation

Fresh Air Ventilation

Homepage > Products > Decentralised ventilation Systems > Vertical devices > Type FSL-V-ZUS. Type FSL-V-ZUS

290 on. 286 on. Comfortable climate with pre-heated, filtered supply air. Fresh air boxes ALB WW MODEL WITH WARM WATER HEATING

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

TopMaster Air Handling unit. Technical data

Typical Operating & Maintenance Manual for SOLA-BOOST X-Air Project Name

DAIKIN Air Handling Unit Modular

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

Water-cooled chillers with High Speed Centrifugal Compressors

66 on. Central ventilation system ZLS-DV EC according to DIN Central ventilation system ZLS EXTRACT AIR FIRE PROTECTION OUTSIDE AIR

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Specification Data. General:

Safety Precautions CAUTION:

Lossnay RVX Fresh Series Air Ventilation

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

MRXBOX95AB-WH2 (with automatic summer bypass)

X-Stream Air Natural Ventilation kits are predominantly designed for self-installation. Suitable for ventilating existing and new build applications.

VEX100 series Air handling units with cross-flow heat exchanger

energisava 300 & 400 Constant flow technology High Efficiency Whole House Heat Recovery Systems

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

TECHNICAL SPECIFICATIONS - CW-80T-TWIN USA & MEXICO

If a peak space temperature to about 28ºC is acceptable to the occupants then a naturally ventilated solution is a viable option.

The quietest bathroom fan. Fact.

Transcription:

The new Xcell EC High Efficiency Range Fresh air pure and simple

The new Xpelair saving energy, saving money 2 www.xpelair.co.uk

Introducing the NEW Xpelair Xcell EC High Efficiency range. The Xcell EC high efficiency range of energy recovery ventilation units builds on the success of Xpelair s customised solutions, incorporating energy efficient technologies and modern control strategies within a standard range of four models. With new energy efficiency regulations 2010, ERP 2013/15 and continuing demands to reduce energy usage, Xcell delivers, for both today and into the future. Xcell reduces heating & cooling requirements by up to 94% compared to conventional fan only ventilation systems, ensuring minimal energy wastage. The integral demand controlled ventilation feature further reduces energy consumption whilst optimising indoor air quality. 3

Xcell s Energy Efficiency Pedigree Xpelair s new Xcell range of energy recovery units offers the highest efficiency ventilation solution. Incorporating market leading technologies, Xcell has been designed with today s energy costs in mind, minimising wastage and using the latest demand controlled ventilation system to ensure optimum indoor air quality, whilst minimising energy consumption and reducing associated losses when compared to extract ventilation systems. The energy saving technologies incorporated into each Xcell unit are: Aluminium Counterflow heat exchanger Xcell units incorporate a market leading Counterflow heat exchanger, with Eurovent certified ratings in accordance with EN308 of up to 90% and higher in the case of condensation, <=94%. The Counterflow heat exchangers with channelled airflow guides are made from seawater resistant aluminium and designed to achieve higher efficiencies over the entire volumetric range. Precision engineered with a totally smooth outer surface to ensure optimum air-tightness. Sealing between plates is achieved through adhesive diffusion of the sealing substance. This ensures high levels of impermeability are maintained, preventing the transfer of odours or humidity. There is no use of rivets or screws and the robust aluminium construction is insensitive to frost related damage and tolerant to pressure in-balance, unlike paper or plastic variants. Extremely hygienic through optimum drainage of all condensate with no niches or areas which can retain water and therefore prevents the build up or spread of germs. High Efficiency Motorised Impellers High efficiency EC motors and backward curved impellers ensure minimum energy consumption and offer maximum efficiency (ErP 2015 compliant). Motor switching is undertaken electronically with no physical contacts reducing wear, heat losses and improving reliability. The EC technology is also infinitely speed controllable and offers increased energy savings across the complete speed control range when compared with conventional inverter drive solutions. The result is higher efficiency, reduced noise, accurate controllability, better speed control, less power and as a result better overall system performance. Benefits include: Continuous speed control across the full operating range giving an increased tolerance to high and low pressure. Low noise compared to a step control motor. Improved service life. Power input lost as heat is reduced by a third compared to a conventional AC motor. The ease of speed controllability of the EC motors makes the interaction with the inbuilt Demand Controlled Ventilation system simple, delivering a significant energy reduction when compared to AC Fans, which is significantly increased when the system operates under partial load. 4 www.xpelair.co.uk

Xcell s Energy Efficiency Pedigree Demand Controlled Ventilation (DCV) DCV is a ventilation control strategy that provides just the right amount of outside fresh air needed by the occupants. Active control of the ventilation system provides the opportunity to control indoor air quality. The figure below shows the ventilation savings potential (area in gold) for a typical application where DCV replaces fixed scheduled ventilation. Automatic bypass (100%) Using in built temperature sensors, when energy recovery is not beneficial, the automatic damper operates to bypass the heat exchanger cell, to limit over/under temperature. Night Cooling When selected, this function takes advantage of lower night time temperatures, allowing pre-cooling of the building fabric prior to daytime occupation. This function helps to reduce building overheat in non air conditioned spaces or reduce start up loads in air conditioned spaces. BMS integration Xcell s inbuilt DCV control offers significant running cost savings over conventional time-clock controlled fixed volume ventilation systems by automatically adjusting the ventilation rate to suit the occupancy of the ventilated area. The minimum and maximum ventilation rates are set during commissioning, and then the chosen sensors automatically control the ventilation system. Sensor options include: Available for building system integration are a range of BMS communication interfaces to suit proprietary communication protocols: N2 Open LONWORKS BACnet MS/TP RS-232C serial interface Each unit also includes as standard three output relays, which can be user configured to the following options: General alarm Heat Demand Cool Demand Frost Shutdown command PIR Sensor senses occupancy in the ventilated area and turns the ventilation On or boosts ventilation rate. CO 2 Sensor measures the CO 2 produced by occupants and increases the ventilation rate proportionally to maintain IAQ. Humidity Sensor when the preset level is exceeded it automatically boosts the ventilation rate. Air quality Sensor senses contaminants such as cooking, toilet and body odours and when the preset level is exceeded it automatically boosts the ventilation rate. 5

Efficiency With high efficiency EC long life motors reducing running costs as well as an aluminium counterflow energy recovery cell with efficiencies of up to 94%, the new Xcell range extends the Xpelair Carbonlite family even further. Carbonlite Control Package Each unit comes with a, BMS compatible, demand based ventilation control which can be customised with a range of sensors to suit specific application requirements, ensuring maximum flexibility whilst optimising IAQ with minimal energy usage. Quiet Running Manufactured from high quality 25mm double skinned panels, thermally and acoustically insulated to reduce noise break out. Filter Protection All Xcell units have G4 filters fitted as standard to both supply and extract. A user definable pre-warning function within the controls system advises when the filter requires replacement, ensuring optimum air quality and energy usage. Easily Maintained With bottom and side access as standard this complete range of energy recovery units can be easily maintained whatever the application. Ancillaries With a matching set of ancillaries including duct heaters the Xcell range is designed to meet your specification requirements. 6 www.xpelair.co.uk

Compact Energy Recovery Units Key Features Compact design. Models Xcell 700 Product Reference: 92771AA Designed to operate at airflows up to 700 m3/hr Xcell 1200 Product Reference : 92772AA Designed to operate at airflows up to 1200 m3/hr Xcell 1500 Product Reference: 92773AA Designed to operate at airflows up to 1500 m3/hr Xcell 2000 Product Reference: 92774AA Designed to operate at airflows up to 2200 m3/hr Counterflow recuperator giving up to 94% energy recovery Eurovent certified. Ultra efficient EC motors with backward curved impellers for increased efficiency and reduced running costs. BMS compatible, integrated demand control ventilation. A comprehensive range of control sensors to suit application. Xcell units are available as an external roof mounted model with factory fitted roof, plus inlet and discharge protection. 90 Xcell 700 Efficiency 78 Xcell 1200 Efficiency 87 84 Efficiency (%) 84 Efficiency (%) 81 81 78 78 0 50 100 150 200 l/s 0 100 200 300 400 500 600 700 m 3 /h Air Volume Flow Rate 0 0 50 100 150 200 250 300 350 l/s 0 500 1000 m 3 /h Air Volume Flow Rate 90 Xcell 1500 Efficiency 90 Xcell 2000 Efficiency 87 87 Efficiency (%) 84 Efficiency (%) 84 81 81 78 78 0 50 100 150 200 250 300 350 400 l/s 0 50 100 150 200 250 300 350 400 450 500 550 l/s 0 500 1000 1500 m 3 /h 0 500 1000 1500 2000 m 3 /h Air Volume Flow Rate Air Volume Flow Rate EN308 efficiency curves 7

Xpelair Xcell 700 Performance Selection Technical data Control Airflow Static Pressure Run Current Unit Power SFP Volts l/s Pa A W W/l/s 5.5. 45 150 0.31 72 1.60 7 92 150 0.62 146 1.59 8.5 135 150 1.05 254 1.88 10 160 150 1.37 340 2.13 Energy Recovery Ambient Extract Airflow Efficiency Heat Recovered Supply Temp C/%rh C/%rh l/s Wet/Dry % Wet/Dry kw C -5/86 22/60 45 94.7/87.4 1.40/1.30 20.6 28/70 22/50 45 86.3/86.3 0.30/0.30 22.8-5/86 22/60 160 90.5/81.0 4.70/4.20 19.4 28/70 22/50 160 80.0/80.0 0.90/0.90 23.2 Performance Graph Supply 240V 50Hz 8 www.xpelair.co.uk

Xcell 700 Technical Data Case Breakout noise Control Voltage Distance (m) 10 8 7 6 5 4 2.5 1 46 40 37 34 32 30 22 db(a) 1.5 42 37 34 31 29 26 19 db(a) 3 36 31 28 25 23 20 13 db(a) In-duct Return noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 33 39 35 32 31 23 23 27 6 47 50 57 55 44 37 30 33 8 60 54 58 59 51 44 36 35 10 74 58 60 64 57 51 42 37 In-duct Supply noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 35 33 33 30 28 21 20 27 6 46 43 58 54 49 43 27 27 8 57 48 60 62 56 51 35 28 10 67 54 61 70 63 59 44 29 Case breakout noise levels db(a) are free field sound pressure levels at the specified distances assuming a hemispherical propagation at reference level of 2 10-5 Pa In-duct noise levels db are sound power levels at reference level of 10-12 W Dimensions 1170 FIXING 200 CENTRES 200 WEIGHT ~ 100 kg 820 FIXING CENTRES FRESH EXHAUST RETURN SUPPLY BYPASS DAMPER UNIT ISOLATOR SWITCH CONTROL ENCLOSURE 55 1570 55 350 290 290 300 300 Ø10 CONDENSATE CONNECTION 420 40 780 910 9

Xcell 1200 Performance Selection Technical data Control Airflow Static Pressure Run Current Unit Power SFP Volts l/s Pa A W W/l/s 4 20 150 0.62 76 3.80 6 172 150 2.1 306 1.78 8 268 150 4.6 720 2.69 10 308 150 6.2 920 2.99 Energy Recovery Ambient Extract Airflow Efficiency Heat Recovered Supply Temp C/%rh C/%rh l/s Wet/Dry % Wet/Dry kw C -5/86 22/60 172 91.4/82.3 5.14/4.63 19.7 28/70 22/50 172 81.3/81.3 1.03/1.03 23.1-5/86 22/60 308 89.4/79.5 9.0/8.0 19.1 28/86 22/60 308 78.5/78.5 1.78/1.78 23.3 Performance Graph Supply 240V 50Hz 10 www.xpelair.co.uk

Xcell 1200 Technical Data Case Breakout noise Control Voltage Distance (m) 10 8 7 6 5 4 2.5 1 57 55 52 50 32 31 30 db(a) 1.5 53 51 48 46 29 28 26 db(a) 3 47 45 42 40 23 22 20 db(a) In-duct Return noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 40 43 37 31 32 25 20 27 6 55 59 61 58 55 45 42 36 8 58 63 64 61 60 51 46 41 10 61 68 67 65 64 56 51 46 In-duct Supply noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 38 38 39 38 38 26 20 27 6 53 57 61 64 61 56 37 28 8 57 61 66 68 66 61 42 31 10 60 65 70 72 71 67 48 34 Case breakout noise levels db(a) are free field sound pressure levels at the specified distances assuming a hemispherical propagation at reference level of 2 10-5 Pa In-duct noise levels db are sound power levels at reference level of 10-12 W Dimensions 730 730 FIXING FIXING 200 CENTRES CENTRES 200 WEIGHT ~ 145 kg 1140 FIXING CENTRES FRESH EXHAUST RETURN SUPPLY BYPASS DAMPER UNIT ISOLATOR SWITCH CONTROL ENCLOSURE 55 1860 55 350 290 290 450 450 Ø10 CONDENSATE CONNECTION 590 1100 40 1230 11

Xcell 1500 Performance Selection Technical data Control Airflow Static Pressure Run Current Unit Power SFP Volts l/s Pa A W W/l/s 4 78 100 0.8 110 1.41 6 196 150 2.0 320 1.63 8 324 150 4.2 710 2.19 10 370 150 5.6 920 2.49 Energy Recovery Ambient Extract Airflow Efficiency Heat Recovered Supply Temp C/%rh C/%rh l/s Wet/Dry % Wet/Dry kw C -5/86 22/60 78 95.5/88.9 2.43/2.27 20.8 28/70 22/50 78 87.8/87.8 0.50/0.50 22.7-5/86 22/60 370 90.4/80.9 10.93/9.78 19.4 28/70 22/60 370 79.9/79.9 2.17/2.17 23.2 Performance Graph Supply 240V 50Hz 12 www.xpelair.co.uk

Xcell 1500 Technical Data Case Breakout noise Control Voltage Distance (m) 10 8 7 6 5 4 2.5 1 57 55 52 49 44 38 27 db(a) 1.5 53 51 48 46 38 34 23 db(a) 3 47 45 42 39 34 28 17 db(a) In-duct Return noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 37 43 36 32 30 25 19 26 6 55 63 58 53 52 44 35 33 8 58 66 62 58 57 49 40 38 10 61 69 66 63 61 54 45 41 In-duct Supply noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 37 46 41 46 42 41 19 26 6 54 62 63 64 62 58 39 30 8 58 66 66 68 66 63 45 34 10 63 69 70 71 71 68 51 38 Case breakout noise levels db(a) are free field sound pressure levels at the specified distances assuming a hemispherical propagation at reference level of 2 10-5 Pa In-duct noise levels db are sound power levels at reference level of 10-12 W Dimensions WEIGHT ~ 182 kg 533 534 533 FIXING FIXING FIXING 200 CENTRES CENTRES CENTRES 200 1140 FIXING CENTRES FRESH EXHAUST RETURN SUPPLY UNIT ISOLATOR SWITCH CONTROL ENCLOSURE 55 2000 55 550 490 490 450 450 Ø10 CONDENSATE CONNECTION 590 1100 40 1230 13

Xcell 2000 Performance Selection Technical data Control Airflow Static Pressure Run Current Unit Power SFP Volts l/s Pa A W W/l/s 4 100 100 0.8 110 1.10 6 285 150 2.4 380 1.33 8 475 150 5.0 840 1.77 10 520 150 6.3 1040 2.00 Energy Recovery Ambient Extract Airflow Efficiency Heat Recovered Supply Temp C/%rh C/%rh l/s Wet/Dry % Wet/Dry kw C -5/86 22/60 100 95.4/88.8 3.12/2.90 20.8 28/70 22/50 100 87.6/87.6 0.64/0.64 22.7-5/86 22/60 520 90.0/80.3 15.62/13.94 19.3 28/70 22/50 520 79.3/79.3 3.10/3.10 23.2 Performance Graph Supply 240V 50Hz 14 www.xpelair.co.uk

Xcell 2000 Technical Data Case Breakout noise Control Voltage Distance (m) 10 8 7 6 5 4 2.5 1 54 50 46 42 40 37 21 db(a) 1.5 50 47 43 39 36 34 17 db(a) 3 44 41 37 33 31 28 11 db(a) In-duct Return noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 42 37 35 31 27 18 18 25 6 52 64 62 52 49 42 32 27 8 55 63 66 55 52 46 37 32 10 58 62 70 58 54 49 42 36 In-duct Supply noise Control Frequency Hz Volts 63 125 250 500 1000 2000 4000 8000 2.5 42 35 34 33 30 23 18 25 6 51 63 57 56 54 49 36 26 8 55 62 62 62 60 55 44 33 10 58 62 67 67 66 60 52 39 Case breakout noise levels db(a) are free field sound pressure levels at the specified distances assuming a hemispherical propagation at reference level of 2 10-5 Pa In-duct noise levels db are sound power levels at reference level of 10-12 W Dimensions 533 534 533 FIXING FIXING FIXING 200 CENTRES CENTRES CENTRES 200 WEIGHT ~ 190 kg 1140 FIXING CENTRES FRESH EXHAUST RETURN SUPPLY UNIT ISOLATOR SWITCH CONTROL ENCLOSURE 55 2000 55 700 640 640 450 450 Ø10 CONDENSATE CONNECTION 590 1100 40 1230 15

Units for External Mounting Dimensions DIM C All Xcell units for external mounting are factory fitted with a pitched weather protection roof, two channel base rails, control enclosure for full protection, intake louvre and exhaust cowl. FRESH DIM D RETURN Model Product Reference EXHAUST SUPPLY Xcell 700WP External Unit Xcell 1200WP External Unit Xcell 1500WP External unit Xcell 2000WP External Unit 92757AA 92758AA 92759AA 92760AA Ø10 CONDENSATE CONNECTION DIM G 100 100 Ø50 DIM A Weather cowl (WPC) Intake Louvre (ITL) DIM H DIM E DIM F DIM B UNIT A' B' C' D' E' F' G' H' 100 45 Weight (kg) 700 1570 780 1670 1100 420 300 290 420 134 1200 1860 1100 1960 1420 420 450 290 590 190 1500 2000 1100 2100 1420 620 450 490 590 223 2000 2000 1100 2100 1420 770 450 640 590 261 Please contact our sales office for options not listed. 17

Integral Control Specification Frost Protection Frost protection is standard. If conditions arise that could lead to the heat exchanger freezing the unit will start an anti-frost cycle. The supply air volume will be reduced to prevent frost from forming. Automatic 100% bypass The bypass section is controlled by interrogating the current operating conditions, and automatically opening or closing the integral damper. This ensures the air supplied to the space is as close as possible to the required control temperature. Speed Control The individual speed control seen on the controller interface, allows for infinitely variable speed adjustment on both supply and extract air flow to suit site conditions Controller The Inbuilt controller has 17 physical inputs / outputs and supports a wide range of temperature sensors and actuating devices. Active optional sensors for the measurement of humidity, pressure, and other variables are also supported. The controller includes an onboard real-time clock. This enables the time scheduling of start and stop commands and occupancy mode changes. Schedule commands can be configured to run on one or more days of the week. An exception day calendar allows alternative time schedules for holidays or during special periods in the year. The realtime clock can run for at least 10 days without power at room temperature. Onboard Inputs and Outputs Up to 17 physical inputs and outputs can be connected to the controller, including: Four Analogue Inputs (Als) Fresh air temperature sensor (Factory fitted) Return air temperature sensor (Factory fitted) Supply air temperature sensor (Factory fitted) Spare 0-10 VDC (For humidity or CO2 sensor connection) Five Digital (Binary) Inputs (DIs) Voltage free contacts preconfigured for: Supply fan failure (Factory fitted) Extract fan failure (Factory fitted) Boost 1 command (Site wired) Boost 2 command (Site wired) Shutdown command (Site wired) Six Digital (Binary) Outputs (DOs) Two triacs (24 V), 24 V Switched bypass damper output Three selectable output configurations, Relay Outputs (24 V or VFC) user configurable from the following options: General alarm Heat demand Cool demand Frost Shutdown command Night cooling Typically used in schools and office buildings, when unoccupied at night. This user selectable option allows the circulation of cooler night time air, to reduce the temperature of the building fabric. As a consequence the heat that has built up during the previous day is removed without using expensive cooling equipment. 18 www.xpelair.co.uk

Optional Controls and Ancillaries Network Room Module (NRM) Product Ref: 92775AA Humidity Sensor Product Ref: 96040AA CO2 Detection Product Ref : 92777AA The NRM is an intelligent device that communicates with the inbuilt controller via the serial display bus, it features a built-in, platinum sensor for accurate measurement of space temperature. The front face of the NRM has operating controls and a backlit LCD, allowing the user to easily control and manage the following: View the space (room) temperature. Manually override the fan See when the controller is in OFF or AUTO mode Adjust the temperature set point, to a physically achievable level Maintenance condition alert Occupancy Detection Product Ref: 21871AA Passive Infrared Sensor XPIRA Duct mounted version available to special order. Automatically increase the ventilation rate when the RH rises above a preset level. Air Quality Sensor Product Ref: 92097AW Detects contaminants such as body, cooking and toilet odours, and activates the boost ventilation rate when the selectable threshold is exceeded. Remote Medium User Interface (MUI). Product Ref: 92776AA Duct mounted version available to special order. Carbon Dioxide sensing range from 0 to 2,000 ppm. With the built in Demand Control Ventilation (DCV) strategy potential energy savings from 10 to 70% can be realised. F5 Pollen Filter sets Xcell 700 F5X7 Xcell1200 F5X12 Xcell1500 F5X15 Xcell2000 F5X20 Product Ref: 92767AA 92768AA 92769AA 92770AA LPHW Duct heaters LPHW Product Ref: Senses occupancy by detecting the difference between heat emitted from the human body in motion and the background space. The passive infrared sensor is capable of 100% cut off coverage, when provided with clear line of site. The controller supports a remote Medium User Interface. The MUI can be flush mounted up to 300m from the controller and can be used for both commissioning the Xcell unit and monitoring ongoing performance Xcell 700LPHW Xcell 1200LPHW Xcell 1500LPHW Xcell 2000LPHW 92763AA 92764AA 92765AA 92766AA Manufactured from solid drawn copper tubes with aluminium fins. Hydraulically tested to 30 bar. Suitable for operating pressures up to 12 bar static head. Fitted with manually operated key pattern air vents and drains (Available up to 12kW, please specify kw required as well as post or pre recovery cell upon order) 19

BMS Compatibility Communication Card Options BACnet MS/TP Product Ref: 92780AA The integral controller can be fitted with a communication card to provide various types of remote network access. The controller supports N2Open, LONWORKS, BACnet Master Slave/Token-Passing (MS/TP), or RS-232C networking communication card options. Communication Card types N2 Open Product Ref: 92778AA Connects controller to the N2 bus of a compatible supervisory controller. This allows network access to its control system variables and parameters. LONWORKS Product Ref: 92779AA Integrates controller into a LONWORKS network. This allows peer-to-peer communication with other LONWORKS compatible devices on the network and data access from a supervisory system. Connects the controller to a BACnet compliant BAS. This allows network access to the controller control system variables and parameters. The controller supports peer-to-peer communication with other controllers on the BACnet network and change-of-value reporting to monitoring stations. RS-232C Serial Product Ref: 92781AA Connects the controller to a Global System for Mobile (GSM) modem. When an application event goes into the active or alarm state, the controller sends out text messages in SMS format to a prioritized list of destinations, such as to a telephone service centre or directly to a mobile telephone. 20 www.xpelair.co.uk

Xcell 700/1200/1500/2000 Accessories - Wiring Diagrams XPIRA PIR C0 2 Sensor LTHW Actuator Humidity Sensor 21

Xcell 700/1200/1500/2000 Typical Specification Operation The supply and extract ventilation unit shall be as the Xcell EC unit manufactured by Xpelair. Unit size and performance shall be as indicated on the drawings and shall be in accordance with the particular fan schedule in this specification. Supply air to the room shall be pre-heated/pre cooled by the extract air via the integrated aluminium counterflow energy recovery cell. Where specified an integral heating element shall raise the temperature of the incoming air into the room(s) being supplied. The energy recovery unit shall utilise a demand control strategy, automatically adjusting the ventilation rates, to suit the conditions relayed by the connected sensors. The controller should be capable of varying the motor speeds either proportionally, or by the more traditional trickle / boost option. Each motor shall be individually commissioned for minimum and maximum ventilation rates via the onboard, infinitely adjustable, speed. Unit Specification Units shall be manufactured from high quality 25mm double skinned, thermally and acoustically insulated GSM panels. Reinforced slotted safety fixing points shall be incorporated to facilitate drop rods or mounting bolts. The unit shall incorporate a high efficiency, Eurovent certified, counterflow energy recovery cell, manufactured from sea water resistant aluminium, which is protected by G4 or improved supply & extract filters. Bypass operation is to be fully automatic, with control dependent upon prevailing conditions. The energy recovery unit shall include motorised impeller assemblies, consisting of a single inlet, backward curved impeller, directly mounted to an EC motor via long life, low energy, maintenance free ball bearings. A condensate drain tray is fitted as standard, and can be supplied with an optional condensate pump if required. The unit shall include integrated fully automatic frost protection control. The supply air volume shall reduce to prevent frost from forming on the energy recovery cell should outside temperatures fall below freezing. Where maintenance is required, the ventilation unit shall come complete with removable side and bottom access panels to ensure clear routes to the following: Supply and extract fan Supply and extract filter Heat recovery cell Frost heater Heater battery temperature adjustment (where included). LPHW Heater pipe connections (where included). Speed control commissioning adjustment (min & max). Control Specification All versions shall incorporate the following functions integrally mounted, pre-wired and factory fitted by the manufacturer: 0-10V speed adjustment. Integral run on timer. On/Off, Min/Max or Automatic ventilation control Infinitely variable fan speed control Two separate boost demand inputs with individual delay and overrun timers. Automatic 100% heat recovery cell bypass when heat recovery is not required. Automatic frost control There are three dedicated volt free contacts, which can be configured to relay a selection of the following conditions to the BMS: General alarm Heat demand Cool demand Frost condition Shutdown command Night cooling function On/Off time scheduler with up to 21 timed On/Off events Night set-back feature, to automatically reduce the heat/ cool setpoints during un-occupied periods. Mains Voltage All units are suitable for use with 240V, single phase 50/60Hz power supply 22 www.xpelair.co.uk

UK Sales Sales Hotline: 0844 372 7750 Sales Fax: 0844 372 7760 International Sales Sales Hotline: +44 (0) 1733 456789 Sales Fax: +44 (0) 1733 456727 Technical Services Techline: 0844 372 7766 Techfax: 0844 372 7767 Newcombe House Newcombe Way Orton Southgate Peterborough United Kingdom PE2 6SE t 0844 372 7761 f 0844 372 7762 www.xpelair.co.uk Xpelair is a registered trademark of Applied Energy Products Ltd. Applied Energy Products reserve the right to alter product specification or appearance without prior notice. All finishes in the brochure are as accurate as printing processes allow. All prices subject to change without notice. Applied Energy Products. All rights reserved.