PRODUCT DATA COMPACT S BY NILAN. Sanitary hot water production. Passive heat recovery. Comfort heating. Ventilation < 375 m 3 /h. Active heat recovery

Similar documents
PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA VP 18 BY NILAN. Sanitary hot water production. Heating. Active heat recovery. Comfort heating. Ventilation < 300 m 3 /h.

PRODUCT DATA VPL 28 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VENTILATION = WELL-BEING

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

Comfortable indoor climate regardless of the season

PRODUCT DATA COMPACT P RANGE BY NILAN. Heating. Sanitary hot water production. Ventilation < 300 m 3 /h. Passive heat recovery.

Technical specifications

USER MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar (English)

PRODUCT DATA NILAIR BY NILAN. Air distribution. Domestic. Ventilation

SOFTWARE MANUAL CTS700 TOUCH BY NILAN. Compact P / Compact P Polar GEO (English)

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

INSTALLATION INSTRUCTIONS

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

Heat recovery unit RDKS

VEX100 series Air handling units with cross-flow heat exchanger

CTS 602 by Nilan. Compact P. Compact P Sun. Compact P Cool. Compact P Cool Sun. Version: 5.00, Software-version: 2.11

Installation instruction

CONTENT: VEX308 Decentralised ventilation VEX308

User manual. CTS 602 by Nilan VPL 15 VPL 15 TOP. Version: 9.02, Software-version: 2.21

THE ROAD TO A HEALTHY INDOOR CLIMATE

KOMFORT EC DB Suspended heat recovery air handling units

Adconair 76. Comfort air conditioning unit with counterflow plate heat exchanger. AIR VOLUME FLOW: 2,600 23,600 m³/h

KOMFORT EC S5B KOMFORT EC D5B KOMFORT EC S. Heat and Energy Recovery Ventilators

MAXI CENTRALIZED VENTILATION WITH HEAT RECOVERY

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

Adsolair 56/58. Comfort air conditioning unit with double plate heat exchanger and adiabatic evaporative cooling system

Healthy, comfortable and energy-efficient ventilation

CI/SfB (57.5) November 2008

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

TECHNICAL INFORMATION HCV 4 - HCV 5 - HCH 5 - HCH 8 Demand-controlled home ventilation

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

Eco Active H E A T R E C O V E R Y S Y S T E M S. Heat Recovery Penthouse Turret. W: T:

Zehnder ComfoAir 550. Ventilation unit

Operation and maintenance instructions

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Technical Information HXV - HRV Ventilation

Healthy, comfortable and energy-efficient ventilation

The new Xcell EC High Efficiency Range Fresh air pure and simple

MRXBOXAB-ECO3 MRXBOX-ECO3

MRXBOXAB-ECO2 MRXBOX-ECO2

Heat and energy recovery ventilators

Installation Instruction

User manual. User manual. CTS 600 by Nilan. Comfort Comfort Version: 10.00, Software-version: 2.30

VENTS VUT R TN H ЕС VENTS VUT R TN EH ЕС

MRXBOXAB-ECO4 100% and Opposite Handed version. Typical Installation

User Manual. Vanvex Optima 180 Domestic Hot Water. Version

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

Zehnder Comfosystems. ComfoAir 180 Datasheet

OPERATING INSTRUCTIONS

TSEK VHR EC HEAT RECOVERY UNITS

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

Breathe Fresh Air at Home

MAKING MODERN LIVING POSSIBLE. Installation Guide. Danfoss Air Units.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

MAKING MODERN LIVING POSSIBLE. User Guide. Danfoss Air Units.

TopMaster Air Handling unit. Technical data

LZT High efficiency air to water heat pumps with E.V.I. compressors

FRESHBOX 100. Single-room heat recovery unit. Air flow up to 59 CFM Heat recovery efficiency up to 96 %

MECHANICAL VENTILATION WITH HEAT RECOVERY (MVHR) NEW ECO RANGE

Installation instruction

Ducted inverter reverse cycle air conditioning

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

SHERPA DHW 75. Th e multifunctional air-water split heat pump. COP > 4 DHW 75 C

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

Primo Hotel. General. Indoor climate units for hotel rooms

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

That allows for installation of a lowresistance ducts system directly from the appliance. CONSTANT FLOW FANS

DESIGN & TECHNICAL MANUAL

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

WORLD VENTILATION LEADER SINGLE-ROOM AIR HANDLING UNITS WITH NEAT RECOVERY VENTILATION SYSTEMS

TopVent Design Handbook

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

panel filters with filtering class G4. Supply filter F7 can be supplied with the few models.

Technical documentation. ComfoAir XL The latest generation of ventilation units with heat recovery

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

ROTEX HPDU monobloc Maximum efficiency in water heating

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

VERSO Air Handling Units

RoofVent Design Handbook

Sentinel Demand Energy Recovery Ventilation

Installation Manual. Instrucciones de instalación y manual de usuario 1

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

Auxiliary Equipment and Accessories

Transcription:

PRODUCT DATA COMPACT S BY NILAN Domestic Passive heat recovery Active heat recovery Ventilation < 375 m 3 /h Comfort heating Comfort cooling Sanitary hot water production

COMPACT S Product description Compact S is an energy-efficient total indoor climate solution for all types of low-energy buildings, single-family homes, flats and small office areas in commercial leases with a ventilation requirement of up to 375 m 3 /h. Compact S recovers the energy from the extracted air using a highly efficient counter flow heat exchanger. The remaining energy that is not utilised by the counter flow heat exchanger is used by the heat pump to produce hot water, and to further heat the supply air. The heat pump has a reversible cooling circuit, which means that, in the summer, the unit can cool the supply air by up to 10 C. Due to the low air exchange, the cooling does not function as an air conditioning system. On cooling, the supply air is dehumidified, which gives a more pleasant indoor climate than is possible with an ordinary ventilation unit without a heat pump. Future-proof system Compact S hot water production fulfils the most stringent requirements in the ecodesign regulation and thereby achieves the highest energy labelling. Compact S A B C D E F G L A 57 db 852 kwh/annum 852 kwh/annum 852 kwh/annum 0 db 2015 812/2013 2

COMPACT S BY NILAN Time-controlled filter change alarm. Easy filter access by opening the top front panel with the help of two finger screws. There is plenty of space to replace filters and to vacuum clean the filter space. 8 duct connections. Compact S is supplied as standard with 4 duct connections in the top. Plates are mounted on the side, which makes it possible to move the ducts from the top to the side as required. Counterflow heat exchanger in polystyrene, with a temperature efficiency ratio of up to 86 %. A clear, user-friendly operating panel with help texts is included. The modern CTS 602 control runs Modbus communication. Automatic bypass function that carries the air past the counterflow heat exchanger when heat recovery is not required. A powder-coated condensation tray prevents the formation of acid water, leading out the condensation water. Compact P has an integrated water lock. Heating pump with hermetically sealed cooling circuit, for production of hot water and active heat recovery. Can raise the air intake temperature up to 34 C. Reversible cooling circuit that can also cool the air intake in the summer up to 10 C, with simultaneous hot water production. Intelligent moisture control. Adapts ventilation to the home s current humidity level. See page 14. CO 2 -sensor can be purchased, for further demand management. The efficient fans are powered by energy-saving EC motors. 180 l hot water tank. 2 layers of glass enamelling to ensure a long lifetime. The hot water tank is foam-insulated, giving good insulation and saving energy. Electrically monitored sacrificial anode and corrosion protection. On any need for replacement, an alarm is activated in the operating panel. 1.5 kw electrical completion. For high hot water consumption where the heating pump cannot cope. Attractive white-painted front with large front panels, giving easy access to service the system. Automatic anti-legionella. Compact S can be supplied with built-in soar coil. The solar coil is intended for solar heating with solar panels of about 0.6 m 2. 3

TECHNICAL DATA Technical specifications Dimensions (W x D x H) 600 x 600 x 2250 mm Weight 160 kg Plate type casing Heat exchanger type Fan type Aluzinc steel plate, white powder coating RAL9016 Polystyrene counterflow heat exchanger EC, constant rotation Supply voltage Max. input/power (*1) Max. input/power (*2) Tightness class Standby power 230 V (±10 %), 50/60 HZ 2,2 kw/ 9,6 A 3,4 kw/14,8 A IP31 3 W Filter class Standard G4 Ambient temperature -20/+40 C Duct connections Ø 160 mm Power consumption build-in preheating element (Polar) 600 W Condensate drain Refrigerant Refrigerant filling PVC, Ø 20 1,5 mm R134a 2.25 kg External leakage (*3) < 0.79% Internal leakage (*3) < 1.47% Capacity SHW tank Supplementary electrical heating (sanitary hot water) 180 l 1.5 kw Connection dimension 3/4 * 1 Input without heating element (accessory). * 2 Input Compact Polar * 3 At ± 250 Pa and 265 m 3 /h according EN 13141-7. * 4 At ± 100 Pa and 265 m 3 /h according EN 13141-7. Hot water production Consumer profile, water heater L (large) Energy efficiency class Energy efficiency for water heating - average climate Annual electricity consumption - average climate A 118 % 852 kwh/annum Temperature settings on the thermostat 10-65 C Sound power level L WA The water heater can function outside peak load periods (Smart-grid) Guidelines for assembly, installation and maintenance Energy efficiency for water heating - cold climate Energy efficiency for water heating - warm climate Annual electricity production - cold climate Annual electricity consumption - warm climate 57 db(a) No See installation instructions 118% 118% 852 kwh/annum 852 kwh/annum A B C D E F G L 57 db Compact S A 852 kwh/annum 852 kwh/annum 852 kwh/annum 0 db 2015 812/2013 4

COMPACT S BY NILAN Dimensional drawing 2250 120 120 418 100 100 418 600 Ø 160 420 101 112 112 Connections 1: Fresh air 2: Supply air 3: Extract air 4: Discharge air 5

MULTI-FUNCTIONAL 100 % heat recovery Compact S ventilates the home, ensuring a good indoor climate. While also producing hot water. Compact S is an untraditional ventilation unit that, in contrast to other ventilation units, recovers 100% of the heat in the extracted air. Supply air Extract air Outdoor air Via a counter flow heat exchanger, up to 95 % of the energy in the extracted air is used to heat the supply air. The built- in heat pump uses the remaining energy to further heat the supply air, while also producing hot water. Discharge air Cooling the home is the challenge of the future New homes are well-insulated and therefore easy to heat. On the other hand, outdoor temperatures do not need to be very high before getting rid of the heat in the home becomes problematic. Compact S has a reversible cooling circuit, to cool the supply air. Due to the low air exchange, it will not function as an air conditioning system. When cooling the supply air will be dehumidified, which contributing to a pleasant climate in the home. Passive heat recovery Passive heat recovery takes place via a counter flow heat exchanger with a high temperature efficiency, whereby the supply air is heated by the extracted air. 6

COMPACT S BY NILAN Extract air Outdoor air Extract air Outdoor air Supply air Supply air Discharge air Discharge air Passive and active heat recovery Utilising the residual energy that the counterflow heat exchanger does not use, the heat pump further heats the supply air. Hot water Utilising the residual energy that the counterflow heat exchanger does not use, the heat pump produces hot water. Extract air Outdoor air Extract air Outdoor air Supply air Supply air Discharge air Discharge air 100% bypass function If heat recovery is not required, the bypass damper closes off 100% and leads the outdoor air past the heat exchanger. Active cooling The heat pump has a reversible cooling circuit and can cool the supply air during hot periods. Hot water can be produced at the same time. Hot water is produced with a high efficiency (COP). This function does not affect the production of hot water, which takes place with high efficiency (COP). 7

PLANNING DATA Capacity Capacity of standard unit as a function of q v and P t, ext. SFP values according to EN 13141-7 are for standard units with G4 filters and without heating element. SFP values comprise the unit s total power comsumption incl. control. Conversion factor: J/m 3 = W/m 3 /h 3600 Pa 250 225 200 175 Max Pa 150 125 100 1000 J/m 3 75 50 800 J/m 3 25 0 50 75 100 125 150 175 200 225 250 275 300 325 350 375 20 30 40 50 60 70 80 90 100 q v [m 3 /h] q v [l/s] Temperature efficiency Temperature efficiency for units with counterflow heat exchanger according to EN13141-7 NB! Temperature efficiency is only for the counter flow heat exchanger (without heat pump operation) 91 90 ŋ t (%) Temperature efficiency 89 88 87 86 85 84 83 82 81 80 50 75 100 125 150 175 200 225 250 275 300 325 350 375 20 30 40 50 60 70 80 90 100 Airvolume q v [m 3 /h] q v [l/s] 8

COMPACT S BY NILAN Heat output supply air Heat output Q c [W] as a function of q v [m 3 /h] and outdoor air temperature t 21 [ C]. In accordance with EN 14511, t 11 =21 C (extract air) Heat output is the contribution to room heating added to the fresh air via Compact S to the supply air. The ventilation loss is the heat output that is lost without heat recovery at the given volume flow air. COP (air-air) Heat output factor COP [-] supply air as a function of outdoor temperature t 21 [ C] and volume flow q v [m 3 /h] in accordance with EN14511 at a room temperature t 11 = 21 C COP according EN14511 is calculated for the heat pump and counter flow heat exchanger combined. 5,8 3400 5,6 3250 5,4 3100 5,2 2950 5,0 2800 4,8 2650 4,6 2500 COP 4,4 4,2 2350 2200 Q [W] 4,0 2050 3,8 1900 3,6 1750 3,4 1600 3,2 1450 3,0 50 75 100 125 150 175 200 225 250 275 300 325 350 375 1300 q v [m 3 /h] 20 30 40 50 60 70 80 90 100 q v [l/s] COP air-air Hear output supply air 9

PLANNING DATA Tapped water Tapped volume in liters V max [L] from Compact S tank as a function of tapped temperature t [C ] and tank temperature at 40, 50 and 60 C [L] 350 300 250 60 C 200 40 C 50 C 150 35 37,5 40 42,5 45 [ºC] COP (air-water) Heat output factor COP [-] and heat output Q w for sanitary hot water as a function of the volume flow q v [m 3 /h] at a tank temperature of 41 C and room temperature t 11 = 20 C, outdoor temperature t 21 = 20 C in accordance with EN 255-3. 1200 4,00 1100 3,80 1000 3,60 Effekt [W] Heat output [W] 900 800 700 Heat output Effekt 3,40 3,20 3,00 COP 600 COP 2,80 500 50 2,60 100 150 200 250 Volume flow [m 3 /h] Volumenstrøm luft [m 3 /h] 10

COMPACT S BY NILAN Sound data Sounddata is for q v = 210 m 3 /h and P t, ext = 100 Pa in accordance with EN 9614-2 for surface and EN 5136 for ducts. Sound output level L WA drops with falling air volumes and falling back-pressure. At a given distance, the sound pressure level L pa will depend on the acoustic conditions at the installation site. Sound output level (L wa ) Octave band Hz Surface db(a) Supply air db(a) Extract air db(a) 63-51 38 125-59 46 250-66 51 500-61 41 1.000-56 31 2.000-54 28 4.000-47 20 8.000-40 13 Total ±2 57 69 53 11

AUTOMATIK CTS 602 Control The Compact S is controlled using its CTS602 operating panel, featuring a wide range of functions, e.g., menu-controlled operation, weekly programme settings, filter monitor with timer, fan speed adjustment, summer bypass (free cooling), supply-heating element control, error messages etc. The CTS602 comes with factory settings, including a default setting which can be customised to operational requirements to achieve optimum operation and utilisation of the system. The operating panel must be placed in a dry, frost-free location, at least 1.5 m above floor level and at least 0.5 m from any corner. Avoid placing the panel on an external wall or in areas in direct sunlight. Operating instructions for the CTS 602 can be found in a separate user manual supplied with the unit. External communication The CTS 602 control unit communicates by default with Modbus RTU RS485 communication. A CTS system using this form of communication can easily be connected to the unit. Nilan units have an open Modbus communication, i.e. not only can the unit be monitored, but its operation can also be set in the same way as it can via the operating panel. CTS / Computer Konverter Modbus The protocol is set up by default for a Modbus RTU 30 address, but can be set to a value between 1 and 247. A Modbus converter allows you to connect one or more units to a computer to monitor and control the unit. 12

COMPACT S BY NILAN Functional overview + Standard - Accessories 3 levels The control function is divided into 3 levels: User/Service/Factory with various options at each level + Weekly plan User option 1 User option 2 The unit has 3 weekly programmes (with a factory setting of off ) Programme 1: for working families Programme 2: for stay-at-home families Programme 3: for businesses There is also an option for you to set your own weekly programme. This allows you to override the operating mode in the main menu via an external potential-free contact or PIR sensor. With an Expansion PCB mounted, allows you to make additional connections, e.g. User option 2 overrides User option 1 (e.g. connecting an EM box) Up to 500 W direct Output relai Switching the central heating system on/off Alarms Alarm log featuring the last 16 alarms. + Datalog Possible to log data. Kapacity 46.000 logs Adjustable between 1 and 120 minutes If OFF, only events and alarms are logged Filter monitor Filter monitor with timer (factory setting of 90 days). Adjustable to 30/90/180/360 days. + Bypass Bypassing the outdoor air reduces heat recovery when heat recovery are not needed. + Air quality Allows you to choose whether to switch humidity sensors and/or CO 2 sensors on and off. +/- Humidity control Allows you to set a higher or lower ventilation step in the case of high/low air humidity. + Summer/Winter operation Possible to set operation for summer and winter Winter low Allows you to select a low ventilation step in the case of low outside temperatures + Defrost function Temperature-based automatic function for defrosting the heat exchanger. + Frostprotection Temperature control Room low Air volume Legionella control In case of failing heating system, the unit is turned off to avoid further cooling with a risk of the water heating coil frost bursting. Allows you to select the temperature sensor which will control the unit. T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Stops the unit at a low room temperature. Hereby is cooling of the home avoided in case of a failing central heating system. Standard set to OFF. Can be set from 1 to 20 degrees and is controlled by: T15 ROOM (panel sensor) T10 EXT (fitted in a representative extraction valve) T3 EXHAUST (extract air) Allows you to set four ventilation steps stepless. Supply air and extract air are set individually. Step 1 < 25% - Step 2 < 45% - Step 3 < 70% - Step 4 < 100% It is possible to choose a weekday or a day during the month, where the sanitary hot water temperature reaches 65 C, for example between 1 and 6 o clock. External firealarm Possible to connect the unit to external firealarm. + Joint alarm Outlet for joint alarm + Constant pressure control Allows control from both the extract air and supply air side. - Cooling Intake air control External heating element External electric heating element Via bypass (can only cool with outdoor temperature) and cool recovery (can only cool with indoor temperature). This allows you to choose whether to run the system at a higher or the highest ventilation step during cooling. The weekly programme has an option for setting cooling at night. Allows you to set the regulator to control the intake air temperature/supply air (only available if the control unit has been configured for a supply-heating element). Temperature sensor T7 is an supply air sensor Integrated frost protection for external water heating element Motorised valve and circulation pump control unit Temperature sensor T7 is an supply air sensor Overheating protection Delayed start-up There is a possibility for a delayed start-up by the fans, when a closing damper is installed. + Reset Allows you to restore the factory settings. + Manual test Allows you to test the unit s functions manually. + Language Option for setting the relevant language (Danish/Finnish/Norwegian/Swedish/German/English/ French). + + - + + + + + + + - - + 13

OPERATION Intelligent humidity control Nilan s humidity control feature automatically adapts to the needs of the family or the building. The intelligent CTS 602 control unit does not need to have a set level input for air humidity (RH) to control the air exchange. By using the integrated humidity sensor, the control unit calculates the average level itself for the last 24 hours. The average level provides a basis for deciding whether to change the air exchange if the air humidity fluctuates. This ensures that the unit always runs at its most efficient, based on the actual air humidity level and not on a theoretical one. Immediately change in % of RH 11 10 9 8 7 6 5 4 3 2 1 Reduced ventilation Forced ventilation Normal ventilation This helps save energy because it automatically adapts to the requirements in the home. Whether a large family or a single person is living in the building has a considerable influence on how much humidity is produced. The unit also adjusts automatically to summer and winter level. 10 20 30 40 50 60 70 80 90 100 Average RH (the last 24 hours) If the air humidity changes by more than 5-10% in relation to the average level, the unit responds with a higher rate of air exchange accordingly. At an air humidity below 30% is reduced ventilation stp activated (adjustable between 15 and 45%) 14

OPERATION COMPACT S BY NILAN Frost protection All ventilation units with a counterflow heat exchanger will ice up if the outdoor temperature is below freezing for a prolonged period. ɳt[%] The extracted air condenses when it is cooled down during heat recovery. The high temperature efficiency will slowly turn the condensate to ice, which will block up the counterflow heat exchanger unless remedial action is taken. It should be considered whether the unit s operation can be protected during a lengthy period of frost or whether it is acceptable to decrease its operation. Temperature efficiency With pre-heater Defrost function t Außen > -3 C t Außen < -3 C In homes which are occupied at night, it would be advisable to protect the unit against frost when the outdoor temperature is coldest by using a pre-heating element. On the other hand, if the ventilation is for an office, it may be acceptable to decrease the operating level at night. Operation Ice building Defrost Ice building Defrost The energy used for the preheating is not wasted, as it ensures a constant high temperature efficiency Frost protection Normal operation No Outdoor temperature < -3 C After 30 min. Yes Pre-heater installed Yes No Normal operation secured until outdoor temp. < -12 C Defrost function starts when: Outdoor temp < 1 C (T8) Discharge air < 3 C in 5 min. When outdoor temp. < -12 C reduced air volume The example below shows the energy used to frost protect versus defrosting. 1. Bypass damper opens 2. The intake motor switches off 3. Warm extracted air will flow through the heat exchanger 4. The ice is melting Air volume 126 m 3 /h 216 m 3 /h Frost protection when outside temperature is -2 C -2 C Hours during the year 676 676 Energy used to frost protection via pre-heating 107 kwh/a 183 kwh/a Loss of energy when icing 105 kwh/a 180 kwh/a Loss of energy when deicing 200 kwh/a 343 kwh/a Energy savings by using frost protection 198 kwh/a 340 kwh/a Defrosting stops when: Discharge air > 7 C (T4) Average calculation by Danish dry weather data. 15

ACCESSORIES Electrical pre-heating element (Frost protection) To prevent the highly efficient counterflow heat exchanger from freezing, we recommend that you fit an electrical pre-heating element. The element consumes very little energy but improves heat recovery. The net result is more cost-efficient operation. Water heating element incl. regulation The supply temperature can always be raised to the required level using a water heating element. The water heating element is designed to be built into the duct and must be connected to the primary heating supply. Supplied with two-way adjustment valve, temperature sensor and frost thermostat. Electrical heating surface incl. regulation When you fit an electrical heating surface, you can raise the fresh air temperature to the desired level at any time. The electrical heating surface is supplied ready to fit into the fresh air duct and, for easy fitting, the device is pre-fitted with all the required sensors. EM-Box The EM-Box distributes extract air between kitchen and bathroom. If the range hood runs via the ventilation system and is operating, extract air flow from the bathroom is reduced to ensure that there is enough air to allow the cooker hood to extract cooking odours. To protect the system, the EM-box is fitted with a metal filter, which efficiently eliminates fat particles from range hood air. DBTU damper If there is not enough space to fit an EM-box, Nilan offers a DTBU damper, which can be fitted between kitchen and bathroom. The damper functions precisely like the EM-box but requires longer cables. Expansion PCB The expansion PCB provides additional functions for the CTS 602 control unit, e.g., controlling the EM box. Pollenfilter F7 Compact S are as standard with G4 filter delivered. If there are someone in the housing which suffers of pollen allergy, it is possible to order a F7 pollenfilter to minimize the amount af Pollen in the supply-air. 16

Noise-attenuating flexible hose For easy fitting and excellent noise attenuation between the system and the distribution box and/or between the system and roof vents. 17

NILAIR NilAIR is installed together with a ventilation unit,which in simple terms consists of distribution boxes from which tubes are led out to air extraction and air supply boxes in the individual rooms. NilAIR can be installed in ceilings, walls or floors. The lightweight tubes can be used for even the most complicated tube alignments, where e.g. traditional spiral ducts cannot be used. Advantages Flexible and space-saving solution Rapid and simple installation with a click system Dimensionally stable and corrosion-resistant quality material Simple regulation of the air supply volume Low weight Airtight Easy to clean Easy to handle and transport Prevents sound travelling from room to room Air extraction (mounted in wall or ceiling) Kitchen Ventilation unit Utility room Bathroom Bathroom Distribution manifold extract air (mounted in floor or ceiling) Soundflex Distribution manifold supply air (mounted in floor or ceiling) Living room Room Room Family room Bedroom Air supply (mounted in floor, wall or ceiling) 18

DELIVERY AND HANDLING Transport and storage Compact S comes in factory packaging that protects it during transport and storage. Compact S must be stored in a dry place in its original packaging until installation. The packaging should only be removed immediately prior to installation. Lifting tool Lifting cover for Compact S makes it possible to lift Compact S of the pallet without making any heavy lifts and transport the system around in the home. Detach the filter box and the system fits under an average inner door. Installation of electric heating element Electric heating elements (accessories) are fitted in the duct. The fitter should ensure that there is a safe distance of at least 15 cm between the electric heating element and any inflammable material. The heating element must be insulated using fire-resistant insulation material. The electric heating element must be connected by an authorised electrician. Electric heating element Electric pre-heating element with temperature sensor (Not the Polar version) Min. 25 cm Min. 25 cm 19

610 328 97 119 160 900 160 337 141 160 120 179 399 INFORMATION FROM A TO Z Nilan develops and manufactures premium-quality, energy-saving ventilation and heat pump solutions that provide a healthy indoor climate and low-level energy consumption with the greatest consideration for the environment. In order to facilitate each step in the construction process from choosing the solution through to planning, installation and maintenance we have created a series of information material which is available for download at www.nilan.dk. Brochure General information about the solution and its benefits. Nilan A/S Nilanvej 2 8722 Hedensted Danmark Tlf. +45 76 75 25 00 Fax +45 76 75 25 25 nilan@nilan.dk www.nilan.dk Product data Technical information to ensure correct choice of solution. WWW.NILAN.DK Installation instructions Detailed guide for installation and initial adjustment of the solution. User manual Detailed guide for regulation of the solution to ensure optimum day-to-day operation. Visit us at www.nilan.dk to find out more about our company and solutions, download further information and find your nearest dealer. Drawings 4 2 Tender documents and 3D drawings are available to download for planning purposes. 1 3 2065 Ver. 1.04-2016.03 Nilan A/S assumes no responsibility for any errors or omissions in the printed information material or for loss or damage that may follow from the use of such published materials - whether such loss of damage is caused by errors or inexpediencies in the material or otherwise. Nilan A/S reserves the right without prior notice to change products and information material. All trademarks are the property of Nilan A/S. All rights reserved.