DB5 Intrinsically Safe Sounder Type DB-5

Similar documents
RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

4) Intrinsic Safety Certification

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Technical Manual for the Horn DB1P UL DB1HP UL

INSTRUCTION MANUAL (ATEX)

IECEx Certificate of Conformity

E2S Datasheet v10a

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Intrinsically Safe Flame Detector Installation Guide

Universal Tank Alarm Type Installation, Operation & Maintenance

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

YO3 - YO4 / YL4 - YO5 / YL5

INSTRUCTION & SERVICE MANUAL

BA334D Intrinsically safe Externally powered pulse input field mounting rate totaliser Issue 13

SET Installation and Operating Instructions. Level switch for one sensor

SET-2000 Oil/Sludge 12 VDC

SET-2000 Hi Level/Oil

Intrinsically Safe Solutions

14300 MAINS SEPARATOR ALARM MANUAL

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

OilSET-1000 (12 VDC)

BA338C Intrinsically safe Externally powered pulse input panel mounting rate totaliser issue 13

805QS Pressure Switch-Transmitter

INSTRUCTION MANUAL (ATEX / IECEx)

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

0 A EIS Intrinsically-Safe Plug-in Intelligent Photoelectronic Smoke Detector INSTALLATION AND MAINTENANCE INSTRUCTIONS

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Technical Manual for the Horn - DB1PUL DB1HP UL

Annubar Flowmeter Series

INSTRUCTION & SERVICE MANUAL

Battery Powered Separator Alarm Type Standalone Unit. Installation, Operation & Maintenance

Solar Separator Alarm Type Installation, Operation & Maintenance

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Technical Data. Dimensions

IECEx Certificate of Conformity

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

DB1 Range - HORNS - Up to 103 db(a)

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Installationsmanual GWSL1100/2100, GWML3100

DICTATOR Hold-Open Systems for Hazardous Areas

IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Inductive slot sensor

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

INSTRUCTION MANUAL. SIL 2 Load Cell/Strain Gauge Bridge Isolating Converter DIN-Rail Power Bus and Termination Board Model D5264S D5264S

OPERATING AND INSTALLATION

PEPPERL+FUCHS GmbH

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Hazardous Area Zirconia Oxygen Systems

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

Easidew PRO I.S. Process Dewpoint Transmitter User s Manual

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

EX-TECH SIGNALLING SAS SD100-1 WEATHERPROOF SOUNDER/HORN TECHNICAL MANUAL

BA488CF Intrinsically safe Panel mounting Fieldbus Display

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EU DECLARATION OF CONFORMITY

Certificate of Compliance

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Technical Data. Dimensions

SIL725 Safety Annunciator

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

AM54. Armored Variable Area Flowmeter Series AM54331/32 Series AM54371/72/73/74 Series AM54431/32 Series AM54471/72/73/74

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

INSTRUCTION MANUAL (ATEX / IECEx)

RT FLOW RATE TOTALISER

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

SOLAR SEPARATOR ALARM

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

INSTRUCTION MANUAL. Frequency-Pulse Converter, Repeater and Trip Amplifiers Din-Rail Model D1060S D1060S

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

Technical Data. Dimensions

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Rosemount 644H and 644R Smart Temperature Transmitters

Model 144H. Product Data Sheet , Rev DB February Content

Declaration of conformity

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

ATEX. IECEx. culs GOST-R. VdS

Tank Gauging System Special Safety Instruction

VTG-32E Spatial Sounder 24Vdc EN54 part 3 approved

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Rosemount 702 Wireless Discrete Transmitter

Dräger Polytron (approved as type P3S) Transmitter for electrochemical Sensors. Instructions for Use. ST eps

Technical Data. Dimensions

Technical Data. General specifications. Rated operating distance s n 5 mm

LN1000 Intrinsically Safe Annunciator

Certificate of Compliance

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Software Version 2.01 LEVEL MONITOR MODEL 220

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

Crowcon Gasmaster. 1 to 4 channel gas detection control panel. Installation, Operation and Maintenance Manual

Fire & Security Products. Siemens Building Technologies Group

standards: standards:

Rosemount 752 Fieldbus Remote Indicator

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Installation and Operating Instruction

Transcription:

Operating Instructions RTK Instruments Limited DB5 Intrinsically Safe Sounder Type DB-5 Description The DB5 Sounder is a strong, lightweight warning sounder, CENELEC certified to Ex II 1G EExia IIC T4 (Ta 20 o C to 55 C) with 26 user-selectable tones, and an output level of over 100dB. Also available certified to CSA, FM standards and for use in mines. Connection Details 1 +ve common 2 +ve common 3 -ve 1 st tone 4 -ve 1 st tone 5 -ve 2 nd tone 6 -ve 2 nd tone To generate the first tone simply connect supply +ve to terminals 1 or 2, and supply ve to terminals 3 or 4. To generate the second tone simply connect supply +ve to terminals 1 or 2, and supply ve to terminals 5 or 6. Note, if +ve is connected to 2 nd sound, it will permanently damage the sounder Each terminal is duplicated and internally connected to allow for ease of connecting subsequent horns or end-ofline (EOL) resistors. Installation Mounting The sounder should be positioned using the two available fixing holes in the base. It is recommended that stainless steel nuts and bolts be used if the environment is corrosive. The sounder will operate in any attitude, from horizontal to vertical. However, it is important to note that the alignment and mounting of the sounder should ensure that: Dust or debris cannot lodge in the re-entrant horn. Water from hose s, jets or rain cannot settle in the reentrant horn. The sounder should be installed in accordance with certified parameters. Removing and Replacing the cover Remove the cover/horn of the sounder by rotating the top of the sounder anti-clockwise, and pulling the cover/horn gently away from the base. Replacing the cover/horn is a reverse process of the above, but care should be taken to ensure that the seal is securely located in its groove during re-assembly. Wiring Cable termination should be in accordance with specifications applying to the application. It is recommended that all cables and cores should be fully identified. Ensure that only the correct glands are used and that the assembly is shrouded. Refer to the connection details below. The twinned-pair inlet terminals and deep base are convenient for looping to other circuits or for siting end-of-line resistors. The base has three knockouts, two on the side and one on the base, to accommodate a 20mm conduit or M20 cable glands. The units are polarised and a chain may be fitted with an end of line resistor for reverse polarity testing and to permit line monitoring. Recommended Cable 0.5 to 2.5mm 2 with earthed screen and insulating sheath. Cable parameters are determined by the output parameters of the interface selected. Safe Area Use In safe areas, the sounders can be powered directly from 24VDC/12VDC. The absence of any current limitation increases the output by approx 4dB. Sound The sound level for each of the individual tones in shown in Table 2. This is assuming one DB5 set at full volume, driven from a suitable IS interface. Where two sounders are driven from the same IS source, the output will decrease by 1.5dB. Three sounders will decrease by 2.2dB. A single turn potentiometer is provided to reduce the volume level by a minimum of 15dB. Page 1 of 9 DB-5 Rev 6

Electrostatic Risk By virtue of it s shape, design and position of use, it is not considered to be an electrostatic risk, however, the apparatus must not be installed in a position where it may be subjected to an excessive air flow that might cause an electrostatic build-up. Intrinsically Safe Specification Certification Certified by BASEEFA to Ex II 1G, EEx ia IIC T4 (Ta 20 o C to 55 C) to CENELEC standards. Certificate No. BAS00ATEX1259 Location IIC T4, installation can be in any zone. Safety Parameters DB5: Ui = 28V, Ii = 28mA, Pi = 0.81W Ci = 0, Li = 20mH + 1000Ω The DB5 Sounder has an internal resistance Ri of 1000Ω which ensures that the input current limit Ii for inductive safety is not exceeded DB5-12: Ui = 15.7V, Ii = 37mA, Pi = 0.56W Ci = 0, Li = 20mH + 325Ω The DB5-12 Sounder has an internal resistance Ri of 325Ω which ensures that the input current limit Ii for inductive safety is not exceeded DB5: Zener Barrier Interfaces Suitable models are: 24v version MTL7728+, 12v version MTL7715+ Galvanic Isoloator Interfaces Suitable models are: MTL5025 DB5-12: Zener Barrier Interfaces Suitable model: MTL7715+ Weight 300g Environment Operating temperature 20 to +55 C Storage temperature 40 to +80 C Humidity 5-95% RH, non-condensing Protection IP65 Construction ABS enclosure with encapsulated electronic module. Colour red. Supply DB5: Min/max at terminals = 15-28VDC Current (through interface) = 14mA DB5-12: Min/max at terminals = 9.6-15VDC Current (through interface) = 12mA EMC Compliance Immunity to EN50082-2:1995 Emissions to EN50081-2:1994 Terminals For conductors up to 2.5mm 2 Page 2 of 10

Mining Certification Certification Certified by EECS to Ex I M1 EEx ia 1 Certificate No: MECS01ATEX4260 Intrinsically Safe Parameters DB-5-M-012: Ui = 14.4V, Uo = 14.4V Ci = 0, Li = 0 CSA Certification Certification Certified by CSA to standard numbers 0, 0.4, 0.5, 25, 30, 205. Class 1 Groups A,B,C and D Certificate No: 79122 Supply Min/max at terminals = 15-28VDC Current (through interface) = 14mA FM Certification Certification Intrinsically Safe for Class I, Division 1, Groups A,B,C and D. Certificate No: J.I 3008604 Entity parameters for DB5 (24V version): Vmax = 28VDC, Imax = 147mA, Pmax = 810mW, Ci = 0, Li = 0 Environment Operating temperature 20 to +55 C Storage temperature 40 to +80 C Humidity 5-95% RH, non-condensing Protection IP65 Zener Barrier Interfaces Contact RTK Instruments Ltd for sduitable models Galvanic Isoloator Interfaces Contact RTK Instruments Ltd for sduitable models Entity parameters for DB5-12 (12V version): Vmax = 15.7VDC, Imax = 150mA, Pmax = 560mW, Ci = 0, Li = 0 Page 3 of 10

Installation Diagram Hazardous area Sounder type DB5 to Certificate BAS00ATEX1259 Ex II 1 G EEx ia IIC T4 See note 4-6 One zener diode safety barrier See notes 1-3 Or galvanic isolation interface Non-hazardous area Non-hazardous area apparatus which is unspecified except that it must not be supplied from nor contain under normal or abnormal conditions, a source or potential with respect to earth in excess of 250VAC RMS or 250VDC. Notes: 1. Any shunt zener diode safety barrier or galvanic isolator, certified by an EEC approved body to [EEx ia] IIC, having the following maximum output parameters: DB5-24: Uo = 28V, Io = 147mA, Po = 0.81W DB5-12: Uo = 15.7V, Io = 150mA, Po = 0.56W 2. Other barriers having lower values than these are permitted. 3. In any safety barrier used the output current must be limited by a resistor R such that: Io = Uo / R 4. The capacitance and inductance of the hazardous area cable must not exceed the values quoted in the certificate for the particular barrier/isolator used. See table 1. If the inductance to resistance ratio (L/R) of the cable is higher than the ratio of the barrier/isolator, the maximum length that can be connected to the interface has to be calculated. 5. The installation must comply with the appropriate national installation requirements e.g. in the U.K. BSEN 60079-14:1997. 6. The circuit in the hazardous area must be capable of withstanding 500V RMS to earth or frame for one minute when using zener diode safety barriers. Cable Parameters Group Capacitance µf Inductance µh L/R ratio µh/ω Typical 28V / 300Ω zener barrier IIC 0.083 4.2 55 IIB 0.65 12.6 165 IIA 2.15 33.6 440 Table 1 Page 4 of 10

Operating Instructions Tone Selection The required tone should be selected by referring to Table 2 below. The 5-way DIL switches on the PCB should then be set to the code as shown (1 being equivalent to the on position, 0 being equivalent to the off position). Sound Level The output sound level shown is for a sounder powered from an RTK WIS1211 interface or from an RTK S951 barrier, fed by 24VDC. Tone no Tone frequency 2 nd tone DIL switch setting 12345 Tone description Level dba 1 Alt Tones 800/970 Hz at ¼ sec 14 11111 88 2 Sweeping 800/970 Hz at 7 Hz 14 11110 91 3 Sweeping 800/970 Hz at 1 Hz 14 11101 94 4 Continuous at 2850 Hz 14 11100 HF 2 nd tone 102 5 Sweeping 2400-2850 Hz at 7 Hz 4 11011 100 6 Sweeping 2400-2850 Hz at 1 Hz 4 11010 103 7 Slow Whoop 14 11001 94 8 Sweep 1200-500 Hz at 1Hz 14 11000 91 9 All tones 2400-2850 Hz at 2 Hz 4 10111 100 10 Int tone of 970 Hz at 1 Hz 14 10110 83 11 Alt tones 800-970 Hz at 7/8 Hz 14 10101 87 12 Int tone at 2850 Hz at 1 Hz 4 10100 100 13 970 Hz at ¼ sec on 1 sec off 14 10011 83 14 Continuous at 970 Hz 14 10010 LF 2 nd tone 85 15 554 Hz for 100mS/440 Hz for 400mS 14 10001 French Fire 91 16 Int 660 Hz 150mS on 150mS off 14 10000 Swedish Fire 86 17 Int 660 Hz 1.8 sec on 1.8 sec off 14 01111 Swedish Fire 87 18 Int 660 Hz 6.5 sec on 13 sec off 14 01110 Swedish Fire 88 19 Continuous 660 Hz 14 01101 Swedish Fire 87 20 Alt 554-440 Hz at 1 Hz 14 01100 Swedish Fire 93 21 Int 660 Hz at 7/8 Hz 14 01011 Swedish Fire 88 22 Int 2850 Hz 150mS on 100mS off 14 01010 Pelican 100 Crossing 23 Sweep 800-970 Hz at 50Hz 14 01001 Low Freq Buzz 92 24 Sweep 2400-2850 Hz at 50 Hz 14 01000 High Freq Buzz 99 25 3 970 Hz pulses 0.5 on/0.5 off, 1.5 off 14 00111 83 26 3 2850 Hz pulses 0.5 on/0.5 off, 1.5 off 14 00110 102 Table 2 Page 5 of 10

Maintenance During the life of the sounder, it should require little or no maintenance. However, if abnormal or unusual environmental conditions occur or due to plant damage or accident etc, then a visual inspection is recommended. Approvals Country and Authority Standard Certificate number Approval for Canada CSA C22.2 No s 0, 0.4, 0.5, 25, 30, 205 79122 Class 1 Groups A-D FM certificate Class 3600 and 3610 J.I. 3008604 Class 1, Div 1 Groups A-D UK HSE(M) EN50014 EN50020 EN50303 MECS01ATEX4260 Ex I M1 EEx ia I UK BASEEFA to CENELEC Certificates available on request. EN50014 EN50020 EN50284 BAS00ATEX1259 Ex II 1 G EEx ia IIC T4 Page 6 of 10

Due to our policy of continuous product development, we reserve the right to amend these specifications without notice. Overall Drawing 55.0 - - - - + + 2ND SOUND 1ST SOUND COMMON 48.0 VOLUME 1 2 3 4 5 CONTROL OPEN 93.0 Ø21.0 TONE SELECTION DIL SWITCH SECTION A-A TWO KNOCK-OUT ENTRIES FOR M20 CABLE GLANDS AND SPACE ON BASE TO DRILL FOR M20 CABLE GLAND 50.0 6 DRILL OUT MOUNTING HOLES FOR M5 SCREWS SECTION B-B Page 7 of 10

Other RTK Products RTK Instruments produce a range of complementary products for many applications in the Industrial Control and Instrumentation field for both safe and hazardous areas, as listed below. All standard products come with a 5 year warranty from this ISO9001:2008 approved company: Alarm Annunciators Remote Logic Alarm Systems Alarm Management software and Touch-screen Annunciators Lamp-boxes and Display Facias Sequence of Event Recorders Universal Panel Meters and Large Displays Power Supplies Complete range of Hazardous Area products including: Intrinsically Safe Alarm annunciators Explosion Proof Alarm annunciators Intrinsically Safe LED Beacons Intrinsically Safe Light Towers Intrinsically Safe LED indicators Intrinsically Safe Illuminated switches and pushbuttons Intrinsically Safe Sounders Intrinsically Safe Relays Please ring our sales office to obtain our latest brochure. Due to our policy of continuous product development, we reserve the right to amend these specifications without notice. Page 8 of 10

This is to certify that the DB5 Intrinsically Safe Sounder EC DECLARATION OF CONFORMITY Supplied by:- RTK INSTRUMENTS LTD ST JAMES BUSINESS PARK KNARESBOROUGH NORTH YORKSHIRE HG5 8PJ Conforms to the protection requirements of the following directives: Council directive 89/336/EEC (EMC Directive) to BS EN50082-2 and BS EN50081-2 Council Directive 94/9/EC (ATEX Directive) to EN60079-0:2009, EN60079-11:2007 & EN60079-26:2007 The product is certified to: Ex ia IIC T4 Ga (-20 o C to +55 o C) Certificate No: BAS00ATEX1259 The Quality System is certified and monitored by Baseefa Ltd, notified Body number 1180, Rockhead Business Park, Staden Lane, Buxton, Derbyshire, SK17 9RZ.... PAUL HARTLEY - MANAGING DIRECTOR Date: 25 th May 2012 Page 9 of 10

REV Detail of Change Date 0 Original Issue 1 2 3 4 Changed to new RTK Instruments format 5 EC Declaration added 21/05/08 6 Updated EC Declaration and replaced S90 and WIS for MTL 24/10/2008 equivalents 7 Updated EC Declaration with details of new certificate 13/09/09 8 Updated EC Declaration and other products list updated 25/05/12 Page 10 of 10