UNITES TERMINALES ET MINI CTA FIDJI

Similar documents
39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

TopMaster Air Handling unit. Technical data

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

FLATAIR. E r P APPLICATION GUIDE kw HORIZONTAL PACKAGED AIR CONDITIONER. Cooling capacity : 6-34 kw. Heating capacity : 6-29 kw

MAGISTER. Compact and attractive design Energy savings with EC motor and self-regulating control. Easy to install. Use. Chilled water operation

50CO. Close Control Unit. Wide range of chilled water cabinets. Compact and attractive design. EC motor for energy savings. Auto-adaptive control

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

GLOBAL LP. Ceiling-mounted ventilation unit with plate heat exchanger

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

The ultimate in air handling units: directly and indirectly fired

eco PREMIUM ENERGY RECOVERY UNIT» Technical instruction

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

VORT NRG RANGE COMMERCIAL VENTILATION NEW

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

EXPAIR. Use. Precision air handling cabinets. Reducted footprint Dual-wall construction

VERSO Air Handling Units

CLIMACIAT AIR COMPACT

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

air systems Large Rooftop DIC-BIH-DIG 360 to 480 G

CLIMACIAT AIRTOP. Air handling units. Very short delivery time Double wall with 50 mm insulation. Complete range meeting all the tertiary requirements

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

48 50 UH UA PACKAGED ROOFTOP

We simplify construction

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

HEAT RECOVERY VENTILATION UNIT DESCRIPTION. FANS s Plug fans. s Direct drive continuous current motors with electronic switching

Precision air handling cabinets Ciatronic MICRO/EXPAIR

VERSO Air Handling Units

COMPACT AIR HANDLING UNIT. CompAir RW. Technical Brochure

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Feature Summary. I. System

ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS PACARE HPE+ Double flow vertical heat pump with recovery wheel.

DAIKIN Air Handling Unit Modular

Air Handling Units. Geniox. Quick guide

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Compact. Efficient. TROX.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

ULTI+ ENVIRONMENTAL CLIMATE CONTROL EQUIPMENT & SOLUTIONS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

SILVERTOP RANGE ENERGY RECOVERY

air systems Roomtop RTC-RTH 15 to 30 - L

CIATCOOLER LJA. Chilled water production units USE. Attractive design, Compact and quiet

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

GLOBAL RX. Ventilation unit with rotary heat exchanger

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Blower-YEFB-020-3R-1maxVel

AIR HANDLING UNITS RIS P EKO 3.0. New range - 5 sizes, 20 models! Efficient EC. E f f i c i e n c y up to 94%! E x t r e m e l y low height! fans!

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

TopMaster Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Energy Recovery with Cooling and Heating Model ERCH

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

WORKSHOP VENTILATION- PSYCHROMETRICS-AHU

KSDR ECOWATT. ErP AHU SIMPLE FLOW. AHU simple flow COMPACT - CENTRIFUGAL - ECM < 20,000 M3/H

EC A1/L2 RIRS V EKO AIR HANDLING UNITS

APPLICATION GUIDE FLEXY FX. Rooftop packaged unit with heat recovery kw FLEXY FX-AGU-1112-E. lennoxemeia.com

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

CLIMASTER ZCF AIR HANDLING UNITS

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Halton Rex for Vario R6O - Variable air volume chilled beam

Heat Recovery ventilation Dee Fly Cube 550 Field of application Description Advantages Range Technical details Installation Remote controls Servicing

The jewel among compact ventilation units

KOMFORT EC DB Suspended heat recovery air handling units

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Fan Coil Range HYDRONIC TERMINALS

Vertical self-contained air conditioner

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

AHU Plus. DX Air Handling Units

The plug & play fresh Air Solution

Roof top SPACE RPC 450Z R407C M011

Roof top SPACE RPC 315Z R407C MA00

Aquair BCP. Pool air handling units. Electronic Control Optimized energy consumption DESCRIPTION PRINCIPLE SCHEMES RANGE OPERATING LIMITS

Customer id 2452 Project 1152 Unit 189 ACON From Inspection Side. Unit name AHU-22 R.05 Supply air EU m³/sec Exhaust air

Manual for the integration in BMS/GTC

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Heat Recovery Units. Heat Recovery 1

Centeral Station Air Handling Unit

TopMaster Air Handling unit. Installation instructions

Homepage > Products > Decentralised ventilation systems > Vertical units > Type FSL-V-ZAB/SEK FSL-V-ZAB/SEK

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

GB 01 ROTARY SCREW COMPRESSORS FIXED SPEED REGULATED SPEED (RS) L 23 L29 L23RS L29RS INTELLIGENT AIR TECHNOLOGY

HCompact2 HA. Compact air-air stand-alone units. Compact horizontal Reduced dimensions Centrifugal fans RANGE DESCRIPTION OPERATING LIMITS SERIES

HIGH PERFORMANCE HEAT RECOVERY UNIT HRF SERIES Nominal air flows from 790 to 4250 m 3 /h

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Transcription:

1 UNITES TERMINALES ET MINI CTA FIDJI

2 Air Handling Unit Fidji Presentation High Effi ciency superposed Heat Recovery Unit, with control factory mounted, for indoor or outdoor installation. Solution adapted to achieve the highest energy certifi cations in commercial, industrial and tertiary buildings. Filtration and preheat of fresh air. Delivered fully pre-wired and factory tested Range: 8 sections from 5 m 3 /h up to 27 m 3 /h. Supplied in one-piece (1, 2, 3 or 4 sections following size and confi guration) up to a length of 3m. Possibility to disconnect the section on job site (as optional "with wiring connectors"). Available with high energy effi ciency thermal wheel or counter-fl ow plate, Eurovent certifi ed. Fidji Air Handling Unit ErP compliant. Main module Aluminium structure with thermal break. Double skin panels RAL739 pre-coated steel exterior and galvanized steel interior Insulation 5 mm mineral wool 35kg/m 3. Pre-fi ltration G4 and M5 on sliding rails. Filtration F7 and F9 on compression sliding rails. Plug fan with EC motor, high duct static pressure option available. Thermal wheel exchanger in aluminium with variable rotation speed. Counter-fl ow plate heat exchanger in aluminium with partial by-pass for lowest pressure dropt and highest heat recovery. By-pass's actuator integrated. Condensate drain pan on plate heat exchanger in standard on Extract Air side. Heating / cooling coils with copper tube and aluminium fi ns. Dampers and fl exible fl anges available as optional on all 4 fl ows. Fully connected and factory tested. User-friendly control program and easily confi gurable. Additional modules F7 or F9 additional bag fi lters. Cooling and/or Heating additional coils. Electrical coils (with separate electrical alimentation if supplied in additional module). 3-ways mixing box Technical data sheet available on website

Self-regulating Heat Recovery Unit FIDJI 3 1 - Plug-fan 2 - Very high efficiency Heat Recovery Systems 3 - G4 to F7 filters class 4 - Control included 5 - Electric or water coil 6 - Large hinged doors, easily maintenance 7 - Cables gland for electrical connection 8 - Feet - Handling by forklift High Efficiency Heat Recovery Systems from 72% to 91% 1 Aluminium Rotary heat recovery (epoxy as optional) EUROVENT AARE C certified 6 Aluminium rotor with variable rotation speed driven by a belt. A purge sector is provided to allow the continuous cleaning of the rotor. In standard, two effi ciencies are available on all sizes to fulfi l customer s constraints and requirements. 2 4 7 5 3 8 UNITES TERMINALES ET MINI CTA Aluminium counter-flow plate heat exchanger EUROVENT AAHE P certified Plate heat exchanger, counter-fl ow type, up to 45 m 3 /h, effi ciencies from 87% to 91% according the operating point. By-pass in standard to allow free cooling operation and to ensure the plate heat exchan- ger defrosting in winter. Plugfan with very high efficiency EC motor Plug fan associated to Electrical Commutation Motor type (EC motors) with two size of motor per unit sizes EC BP for Total static pressure < 8 Pa EC HP for Total static pressure > 8 Pa Fan Motor Assembly ErP 215 compliant Configurable motor Control factory integrated and tested at the end of the production line. Communicant control based on ModBus RTU RS485 or TCP/IP, Bacnet IP or LonWorks protocols. Constant Air Volume (CAV) operation or Variable Air Volume (VAV) operation (according constant duct pressure setpoint, or, CO 2 sensor, or, air quality sensor, or, ). All informations availables: Airfl ow and air pressure, exchangers, registres sur informations multiples de Temperature, pression, CO 2, marche/arrêt à distance, etc.

4 Air Handling Unit Fidji / Pressure range with EC fans 2 High pressure EC fan (EC HP) Standard pressure EC fan (EC BP) 16 12 8 4 FIDJI 15 FIDJI 3 FIDJI 45 FIDJI 65 FIDJI 1 FIDJI FIDJI 2 FIDJI 265 1 2 3 4 5 6 7 8 9 1 11 12 13 14 16 17 18 19 2 21 22 23 24 25 26 Technicals characteristics Materials Structure Insulation Fire classification Heat Recovery Systems (HRS) EUROVENT Certifi ed RAL RAL 739 Alimentation 4V / 3~+N / 5 Hz Main Module RAL 739 1/1 ème pre-coated metal sheet in outer skin and galvanised steel in inner skin Double Skin 5mm mineral wool A2-s1-d Aluminium thermal wheel ~82% effi cient according EN38 H1 according EN1353 or Counter-fl ow plate ~88% effi cient according EN38 H1 according EN1353 Type Motorisation Management Plug-fan Electronic Commutation motors (EC) by internal Modbus Fan Motor Assembly of Main Module Water coils Materials Copper tubes / aluminium fi ns Rows 2 or 4 rows available in the main module ; 2 and/or 4 and/or 6 rows available in additional module ; Heating or Cooling coils Min.- Max. temperature 2 C 1 C Max. service pressure 1 bars Drain pan Insulated and non-removable Main module G4 or M5 pre-fi ltration (as optional) Main module F7 fi ne fi lter conform with EN 779:212 Filters Mixing module Electrical coil module Water coil module Filter module 3-ways On supply air or on fresh air side (preheating) Heating or Cooling coils with 2-ways or 3-ways valves F9 fi ne fi lter Additional Modules

Air Handling Unit Fidji 5 Main module construction Succinct codification principle J 5 I D 4 C A P 1 Supply side Extraction side Sans batterie 1 2-pipes system: Heating water coil alone 2 Rows 2 2-pipes system: Heating water coil alone 4 Rows 3 2-pipes system: Cooling water coil alone 2 Rows 4 2-pipes system: Cooling water coil alone 4 Rows 5 4-pipes system: 2R Heat. coil integrated + 4R Cool. coil in add. module 6 4-pipes system: 2R Heat. coil integrated + 6R Cool. coil in add. module 7 6-pipes system: 2R Heat. coil integrated + 6R Cool. & 4R Heat. coil in add. module 8 2P/2F system: Electric heater integrated + 4R Cool. coil in add. module UNITES TERMINALES ET MINI CTA Without control C Constant Air Volume (C.A.V.) Q Variable Air Volume (V.A.V.) according air quality setpoint. P Variable Air Volume (V.A.V.) according supply duct pressure setpoint No fi lters A Flat G4 B Flat M5 C Flat G4 + short bag F7 D Flat G4 + short bag F9 E Flat M5 + short bag F7 F Flat M5 + short bag F9 1 Thermal wheel heat exchanger 2 Thermal wheel heat exchanger + 3-ways mixing function 3 Counter-fl ow plate heat exchanger 4 Counter-fl ow plate heat exchanger + 3-ways mixing function D Right hand service side G Left hand service side I Indoor installation R Outdoor installation 1 15 2 3 3 45 4 65 5 1 6 7 2 8 265 J FIDJI

6 Air Handling Unit Fidji An efficient control Operting mode (1) (to define on order) Descriptif Remarque Base Option VAV_Variable Airfl ow Volume CAV_Constant Airfl ow Volume Lockable electric isolator Proximity switch 1/4-turn lockable (sensor) Real Time Clock Weekly programming working days, non-working days, reduced operating Setpoint shift on temperature / airfl ow Language French / English Communication protocols Modbus RTU RS485 Modbus TCP/IP ; BACnet IP ; LonWorks Alarm Log Saving of 1 last defaults (with date and hours) Analog sensors Temperature sensors Fresh Air / Supply Air / Return Air / Extract Air Differential pressure transmitter on Supply & Extract plugfans Duct pressure sensor on supply air Air Quality sensor (on return air or in ambient air) Digital inputs On/Off remote contact Presence detector Heating / Cooling Modulating actuators on valves (Additional Coil's module as optional ) Modulating actuators on valves Command of electrical coil with 1, 2 or 3 steps (by relay) with post-ventilation integrated in the control operating logic Heat Recovery System (HRS) Variable rotation speed on thermal wheel Free-Cooling / Free-Heating Antifreeze protection (Reduction / Stop of thermal wheel) following temperature measured by temperatures probes By-pass management Fan (choice fixed on order) Constant Airfl ow on Supply and Extract fans (different instructions possible) On/Off fan's management possible according temperature Variable Airfl ow on Supply and Extract fans (according Air Quality sensor, Constant pressure setpoint on duct, etc...) Control of Air Quality on Return Air (Airfl ow variation on supply and extraction fans) Safety Thermal protection on extraction and supply fans Thermal protection on thermal wheel's motor Belt breakage detector on thermal wheel Filter clogging pressostats on each fi lter stage Antifreeze protection by temperatures probes Safety thermostats on Electrical Coil(s) (if Electric Coil selected) Smoke detector (CTA < 1 m3/h) Smoke detector (CTA > 1 m3/h) - not mounted ; not wired (1) Taking into account the temperature and altitude in the volume airfl ow calculation for an accuracy benefi ts up to 1%.

Air Handling Unit Fidji 7 AIRCALO's control is a friendly system to manage the Heat Recovery Air Handling Units. It aims to take on the main control functions, command and to manage all organs equipping the AHU, whether standard or optional. Each functions of AHU is the subject of a program tested and downloaded in the factory. Confi gurations and comfort settings must be completed on jobsite by installer and/or customer. AIRCALO's control monitors the information provided by the various sensors and probes required for the regulation of the AHU. It continuously analyses all incoming information and in accordance with pre-loaded algorithms, interacting on all AHU's components (fans, valves, dampers,...). Air quality CO 2 Outdoor T( C) Outdoor Air Temperature Extract Air Temperature P on pre-fi lter G4 P on fi ne fi lter F7 Extract airfl ow P on Extract air fan Supply airlfow P on supply air fan P on pre-fi lter G4 Return Air Temperature Supply Air Temperature Static duct pressure on supply UNITES TERMINALES ET MINI CTA Exhaust Air Return Air Outdoor Air Supply Air The possible management mode are: - STOP: switched off. - COMFORT: forced march on day setpoints. - REDUCED: forced march on night setpoints - FROST: forced heating setpoint to 8 C - AUTO : automatic operation according to programs set on the clock. As standard, the AIRCALO's control integrates 4 time zones per day and 7 weekly days programming. Several automatic alarms can manage potential malfunction and organize the maintenance and servicing of the unit.

8 Air Handling Unit Fidji EC Plugfan characteristics EC «BP» Fidji 15 Fidji 3 Fidji 45 Fidji 65 Fidji 1 Fidji Fidji 2 Fidji 265 Wheel diameter 25 31 4 5 56 2x5 2x56 EC references (K3G-...) 25-AV29 -AU11 31-BB49 4-AQ23 5-AP24 56-AQ4 2x5-AP24 2x56-AQ4 Alimentation 23V-1-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz Plugfan quantity 1 1 1 1 1 1 1 1 Power per plugfan (kw).75 1. 1.65 3.38 3.54 4.6 7.8 (3.54x2) 9.2 (4.6x2) Maxi. rotation speed (tr/mn) 3 45 3 1 3 14 2 68 1 91 1 75 1 91 1 75 EC «HP» Fidji 15 Fidji 3 Fidji 45 Fidji 65 Fidji 1 Fidji Fidji 2 Fidji 265 Wheel diameter 31 4 45 45 2x45 2x45 3x45 EC references (K3G-...) -AU11 31-BB49 4-AQ23 45-AZ3 45-AZ3 2x45-AZ3 2x45-AZ3 3x45-AZ3 Alimentation 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz 4V-3-5Hz Plugfan quantity 1 1 1 1 1 2 2 3 Power per plugfan (kw) 1. 1.65 3.38 5.25 5.25 1.5 (5.25x2) 1.5 (5.25x2) 15.75 (5.25x3) Maxi. rotation speed (tr/mn) 3 1 3 14 2 68 2 75 2 75 2 75 2 75 2 75 The operating point management is realized by a modbus command. The nominal power of Air Handling Unit is based on the desired operating point. It is the sum of the power of each fan(s) selected on supply and extract side. EC motors are provided with internal thermal protection. Electrical coils Coil alimentation: 4 V - 3ph. - 5 Hz (1~ 23V available as optional on Fidji 15 with EC «BP» plugfans on supply and extract air). Models Fidji 15 Fidji 3 Fidji 45 Fidji 65 Fidji 1 Fidji Fidji 2 Fidji 265 Minimum airflows (m 3 /h) 6 11 17 24 38 56 77 11 Maximum capacity (kw) 2,25 3, 4,5 12, 15, 18, 21, 36, Type Type Type Steps 1 1 1 2 2 2 2 2 Capacity / steps (kw) 2.25 3 4,5 6+6 7,5+7,5 9+9 1,5+1,5 12+24 Maximum capacity (kw) 4,5 9, 13,5 18, 3, 45, 63, 72, Steps 2 2 2 2 3 3 3 3 Capacity / steps (kw) 2,25+2,25 3+6 4,5+9 6+12 7,5+7,5+15 9+18+18 1,5+21+31,5 12+24+36 Maximum capacity (kw) 6,75 12, 18, 3, 45, 63, 84, 18, Steps 2 3 3 3 3 3 3 3 Capacity / steps (kw) 2,25+4,5 3+3+6 4,5+4,5+9 6+12+12 7,5+15+22,5 9+18+36 21+31,5+31,5 24+36+48 Capacity per element (kw),8 1, 1,5 2, 2,5 3, 3,5 4, When the unit is supplied with Electrical Heater, manual and automatic safety thermostat are supplied in standard. The manual safety thermostat is set to trigger at 15 C. The electrical coil in additional module must have its own alimentation (different from the main alimentation of the AHU). CAUTION: if the control of electrical coil is not realized by AIRCALO, provide a timeout forced fan operation after stopping the electrical coil to ensure its refresh: - for capacity < 9 kw 4 minutes time delay minimum - for capacity 9 kw 5 minutes time delay minimum

Air Handling Unit Fidji 9 Performances and main characteristics Range FIDJI 15 FIDJI 3 FIDJI 45 FIDJI 65 FIDJI 1 FIDJI FIDJI 2 FIDJI 265 Minimum airflow (wheel 1.5mm: efficiency > 84%) m 3 /h 1 138 1 63 2 935 4 559 6 5 1 198 14 812 2 217 Nominal airflow (wheel 1.5mm: efficiency > 82%) m 3 /h 1 38 2 48 3 855 5 569 8 637 12 53 17 86 22 353 Maximal airflow (wheel 1.5mm: efficiency > 8%) m 3 /h 1 63 2 935 4 559 6 5 1 198 14 812 2 217 26 344 Models FIDJI 15 FIDJI 3 FIDJI 45 FIDJI 65 FIDJI 1 FIDJI FIDJI 2 FIDJI 265 Counter-flow Plate Heat Exchanger (Efficiency ~88%) Global SFPv (3) W/m 3.s 26 2265 2497 Main module length (without 3-ways section) mm 195 225 275 Main module weight (+/- 1%) kg 3 41 636 Thermal Wheel Heat Exchanger 1.5mm (Efficiency ~82%) Global SFPv (3) W/m 3.s 1991 29 225 1952 196 197 24 1819 Main module length (without 3-ways section) mm 156 1745 21 235 256 2725 256 2725 Main module weight (+/- 1%) kg 272 36 525 682 937 1239 1473 1829 Thermal Wheel Heat Exchanger 2.mm (Efficiency ~72%) Global SFPv (3) W/m 3.s 1719 1813 237 1729 1731 1713 1772 1616 Main module length (without 3-ways section) mm 156 1745 21 235 256 2725 256 2725 Main module weight (+/- 1%) kg 27 357 52 674 926 1222 145 1799 UNITES TERMINALES ET MINI CTA Filters FIDJI 15 FIDJI 3 FIDJI 45 FIDJI 65 FIDJI 1 FIDJI FIDJI 2 FIDJI 265 Filter frame air leakage EN 1886 F9 in negative pressure / F8 in positive pressure Filters available in main module EN 779 Flat G4 or M5 pre-fi lters and/or fi ne F7 or F9 bag fi lters Filters available in additional modules EN 779 F7 or F9 bag fi lters Heating mode Cooling mode Water coils (1) FIDJI 15 FIDJI 3 FIDJI 45 FIDJI 65 FIDJI 1 FIDJI 1 FIDJI 2 FIDJI 265 Available rows - 2 or 4 rows 2 Rows - Total capacity (2) kw 6,2 11,2 17,8 24,9 4,6 6,6,6 12,2 4 Rows - Total capacity (2) kw 1,8 2, 31,1 46,5 7,6 15,3 136, 181,9 Available rows - 4 or 6 rows 4 Rows - Total capacity (2) kw 6,4 11,8 18,4 27,8 41,9 62,9 79,6 17,1 4 Rows - Sensible capacity (2) kw 4,3 7,9 12,3 18,2 27,9 41,4 53,9 71,7 6 Rows - Total capacity (2) kw 8,2 15,4 24,1 35,4 55,1 8,6 12,3 137,9 6 Rows - Sensible capacity (2) kw 5,4 1, 15,7 23, 35,8 52,2 68,1 9,6 (1) Only one coils can be inserted in the main module. Water coil 2 or 4 rows, or, Electrical coil (if I absorbed of main module <1A). Coil 6 rows only in additional module. (2) Conditions: Winter: Air inlet Temperature = outlet heat exchanger temperature ; heat water 6/4 C ; nominal airfl ow Summer: Air inlet Temperature = outlet heat exchanger temperature ; chilled water 7/12 C ; nominal airfl ow (3) Confi guration: OA: M5/F7 - RA: M5 - Fans EC BP - 25 Pa available return / supply - nominal airfl ow

1 Air Handling Unit Fidji Double flux configurations Thermal Wheel Heat Exchanger version Efficiency from 72% up to 87% Counter-flow Plate Heat Exchanger version Efficiency from 87% up to 91% 8 sizes from 5 up to 27' m 3 /h (composed with 1 to 4 modules according the sizes) 3 sizes from 5 up to 4'5 m 3 /h (composed with 1 to 4 modules according the sizes) Fresh Air Heat Recovery Unit (Without coil) Fresh Air Heat Recovery Unit (Without coil) Heat Recovery Air Handling Unit with Water coil integrated Heat Recovery Air Handling Unit with Water coil integrated Heat Recovery Air Handling Unit with 3-ways mixing section without coil Heat Recovery Air Handling Unit with 3-ways mixing section without coil Heat Recovery Air Handling Unit with 3-ways mixing section and Water coil integrated Heat Recovery Air Handling Unit with 3-ways mixing section and Water coil integrated

Additional modules JR A JR B JR D Air Handling Unit Fidji Empty casing Filter casing (side access only) Electrical coil module Bag fi lters F7, F9 11 from 2.25 to 18 kw following the unit size up to 1, 2 or 3 steps UNITES TERMINALES ET MINI CTA JR E Water coil module Additional coils 2-rows and/or 4-rows and/or 6 (2 coils max. in the same module). With drain pan and droplet eliminator for the cooling coil for high air velocity and/or high air humidity. Accessories JR K Rain hood REG + SRV Total damper + Actuators On/Off - 23 V with spring return (up to 4 dampers per unit) MAN Flexible fl ange to install on AHU or on damper (supplied loose to assemble on jobsite) JR M Circular plenum connectors (Fidji 15: 1x Ø 315 ; Fidji 3: 1x Ø 4 ; Fidji 65: 1x Ø 5) A B JR N A: Roof kit for main module B: Roof kit for each additional module

12 Air Handling Unit Fidji 15 Dimensions - Plate Heat Exchanger version 81 195 691 326 M 15/21 268 241 89 Condensate Ø 22 43 59 753 1893 Main module delivered in one-piece. Side handling. Forklift forks 1mm mini. Dimensions - Plate Heat Exchanger version + 3-ways 81 23 1225 175 691 326 M 15/21 241 268 89 Condensate Ø 22 43 59 753 37 11 1 Main module delivered in one-piece. Side handling. Forklift forks 1mm mini. Dimensions - Additional module 81 55 M 15/21 (1/2") 445 691 326 268 241 268 241 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 114 43 43 13 129 43 43 145 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 15 13 Dimensions - Thermal Wheel version 241 268 81 691 326 89 753 156 M 15/21 Condensate Ø 22 43 59 3 Main module delivered in one-piece. Side handling. Forklift forks 1mm mini. UNITES TERMINALES ET MINI CTA Dimensions - Thermal Wheel version + 3-ways 81 1975 9 175 691 326 M 15/21 241 268 89 753 Condensate Ø 22 43 59 37 853 1 Main module delivered in one-piece. Side handling. Forklift forks 1mm mini. Dimensions - Additional module 81 55 M 15/21 (1/2") 445 268 241 268 241 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 114 43 43 13 129 43 43 145 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

14 Air Handling Unit Fidji 3 Dimensions - Plate Heat Exchanger version 115 225 896 429 M 2/27 276 333 195 958 Condensate Ø 22 43 685 2193 Main module delivered in one-piece. Side handling. Forklift forks 12mm mini. Dimensions - Plate Heat Exchanger version + 3-ways 115 26 143 117 896 429 M 2/27 333 195 276 958 Condensate Ø 22 43 685 37 1383 1123 Main module delivered in one-piece. Side handling. Forklift forks 12mm mini. Dimensions - Additional module 115 55 M 2/27 (3/4") 548 896 429 276 333 276 333 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil 114 43 43 13 129 43 43 145 +1 Global tolerance ( ) -1 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 3 15 Dimensions - Thermal Wheel version 333 276 115 896 429 958 195 1745 M 2/27 Condensate Ø 22 43 685 1688 Main module delivered in one-piece. Side handling. Forklift forks 12mm mini. UNITES TERMINALES ET MINI CTA Dimensions - Thermal Wheel version + 3-ways 115 2165 995 117 896 429 M 2/27 333 276 195 958 Condensate 43 685 Ø 22 37 948 1123 Main module delivered in one-piece. Side handling. Forklift forks 12mm mini. Dimensions - Additional module 115 55 M 2/27 (3/4") 548 896 429 276 333 276 333 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil 114 43 43 13 129 43 43 145 +1 Global tolerance ( ) -1 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

16 Air Handling Unit Fidji 45 Dimensions - Plate Heat Exchanger version 1215 275 66 14 15 196 529 M 26/34 423 1295 2 1158 43 83 Condensate 37 Ø 22 37 613 13 958 Main module delivered in one-piece. Side handling. Forklift forks 14mm mini. Dimensions - Plate Heat Exchanger version + 3-ways 1215 355 66 14 35 15 196 529 M 26/34 423 1295 2 1158 Condensate Ø 22 83 37 37 37 613 13 313 958 Main module delivered in 2-pieces. Handling by the front. Forklift forks 14mm mini. Dimensions - Additional module 1215 55 M 26/34 (1") 648 196 529 423 423 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 2 2 114 43 43 13 129 43 43 145 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 45 17 Dimensions - Thermal Wheel version 1215 196 2 423 529 1158 21 14 195 15 M 26/34 1295 43 83 37 Cond. Ø 22 148 958 Main module delivered in one-piece. Side handling. Forklift forks 14mm mini. Dimensions - Thermal Wheel version + 3-ways UNITES TERMINALES ET MINI CTA 1215 245 195 35 15 196 529 M 26/34 423 1295 2 1158 Condensate Ø 22 43 83 37 37 148 313 958 Main module delivered in one-piece. Side handling. Forklift forks 14mm mini. Dimensions - Additional module 1215 55 M 26/34 (1") 648 196 529 423 423 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil 2 2 114 43 43 13 129 43 43 145 +1 Global tolerance ( ) -1 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

18 Air Handling Unit Fidji 65 Dimensions - Thermal Wheel version 142 235 122 133 633 M 26/34 519 8 1363 Condensate Ø 22 945 1173 37 183 Main module delivered in one-piece. Side handling. Forklift forks 16mm mini. Dimensions - Thermal Wheel version + 3-ways 142 122 45 133 519 633 M 26/34 8 1363 Dimensions - Additional module Condensate Ø 22 43 945 37 37 1173 413 183 Main module delivered in one-piece. Side handling. Forklift forks 16mm mini. 142 55 M 26/34 (1") 75 133 633 519 519 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil 8 8 114 43 43 13 129 4343 145 +1 Global tolerance ( ) -1 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 1 19 Dimensions - Thermal Wheel version 172 163 32 663 796 183 1663 256 885 435 124 M 4/49 Cond. Ø 22 55 139 37 37 838 398 1193 Main module delivered in 2-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Thermal Wheel version + 3-ways UNITES TERMINALES ET MINI CTA 172 294 885 815 124 163 796 3 M 4/49 32 663 183 Cond. Ø 22 55 139 37 37 1663 838 7 1193 Main module delivered in 3-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Additional module 172 55 M 4/49 (1"1/2) 915 163 796 663 663 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 32 32 118 55 134 133 55 149 Condensate Ø 22 Coils 4R(-) + 2R(+) Coils 2R(+) + 4R(-)

2 Air Handling Unit Fidji Dimensions - Thermal Wheel version 23 2725 96 435 133 1911 951 M 4/49 811 214 39 1973 Cond. Ø 22 55 1129 37 37 913 398 13 Main module delivered in 2-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Thermal Wheel version + 3-ways 23 325 96 915 133 1911 951 3 M 4/49 39 811 214 Cond. Ø 22 55 1129 37 37 1973 913 8 13 Main module delivered in 3-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Additional module 23 55 M 4/49 (1"1/2) 17 1911 951 811 811 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 39 39 118 55 134 133 55 149 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 2 21 Dimensions - Thermal Wheel version 2335 2216 329 932 116 245 22 256 885 435 124 M 66/76 Cond. Ø 22 8 1 37 37 838 398 1193 Main module delivered in 2-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Thermal Wheel version + 3-ways UNITES TERMINALES ET MINI CTA 14 2335 314 14 885 115 124 14 2216 116 3 M 66/76 932 245 329 Cond. Ø 22 8 1 37 37 22 838 9 1193 Main module delivered in 3-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Additional module 2335 7 M 66/76 (2"1/2) 1225 2216 116 932 932 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 329 329 133 8 149 148 8 164 Condensate Ø 22 Coils 4R(-) + 2R(+) Coils 2R(+) + 4R(-)

22 Air Handling Unit Fidji 265 Dimensions - Thermal Wheel version 264 2725 96 435 133 2521 1256 M 66/76 335 176 275 2583 Cond. Ø 22 8 19 37 913 398 13 Main module delivered in 2-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Thermal Wheel version + 3-ways 264 335 96 115 133 2521 1256 3 M 66/76 335 176 275 Cond. Ø 22 8 19 37 37 2583 913 9 13 Main module delivered in 3-pieces. Handling by the front. Forklift forks 16mm mini. Dimensions - Additional module 264 7 M 66/76 (2"1/2) 1375 2521 1256 176 176 Casings: - Empty - Filter(s) - Water coil(s) - Electrical coil +1 Global tolerance ( ) -1 335 335 133 8 149 148 8 164 Coils 4R(-) + 2R(+) Condensate Ø 22 Coils 2R(+) + 4R(-)

Air Handling Unit Fidji 23 Handling Fidji Air Handling Unit are delivered under a plastic fi lm protection (not weatherproof - storage under shelter mandatory) with transport feet (no pallet). The unloading and the handling could be done by using a forklift able to carrying the load (weight shown on the delivery note) and provided with suffi cient long forks to cross the entire width of the unit: Sizes Mini. forks length (mm) Fidji 15 1 Fidji 3 12 Fidji 45 14 Fidji 65 16 Fidji 1 16* Fidji 16* Fidji 2 16* Fidji 265 16* * Main unit delivered in x modules. Handling by the front. UNITES TERMINALES ET MINI CTA Handling operation must be done by crane with slings and spreader. Maintenance spacing Provide a clear space for maintenance (replacement of components) around the unit according to the table below : 6 Sizes L L doors Fidji 15 11 65 Fidji 3 1215 8 Fidji 45 1415 8 Fidji 65 162 8 Fidji 1 192 9 Fidji 223 1 Fidji 2 253 1 Fidji 265 4 1 L L doors

24 Air Handling Unit Fidji 15 Coils performances without considering heat recovery outlet 69 84 1 116 132 148 164 8/6 C Outdoor air - 7 C / 9% - 9,4 34,1,12-1,7 31,4,13-12, 29,1,15-13,2 27,1,16-14,3 25,5,17-15,3 25,,19-16,2 22,8,2 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 8,9 31,9,22-5,3 16,1,25-1,4 3,2,25-6,1 16,9,29-11,9,7,29-6,9 17,6,33-13,2 27,3,32-7,7 18,2,37-14,5 26,1,35-8,4 18,8,4-15,8 25,,38-9, 19,3,43-16,9 24,,41-9,6 19,7,46 Coils performances by considering heat recovery outlet 69 84 1 116 132 148 164 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15.5 / 5.8 3,8 31,9,5 15.3 / 5.6 4,4 3,8,5 15.1 / 5.5 4,9 29,8,6 14.8 / 5.8 5,4,8,7 14.5 / 51.1 6,,,7 14.1 / 51.5 6,5 27,1,8 13.8 / 51.8 6,9 26,4,8 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15.5 / 5.8 4,6 35,3,11 25.9 / 53. 3,8 14,8,18 15.3 / 5.6 5,4 34,3,13 26. / 53.1 4,4 15,4,21 15.1 / 5.5 6,1 33,5,15 26. / 53.2 5, 16,,24 14.8 / 5.8 6,9 32,7,17 26.1 / 53.3 5,6 16,5,27 14.5 / 51.1 7,7 31,9,19 26.2 / 53.3 6,1 16,9,29 14.1 / 51.5 8,5 31,2,21 26.3 / 53.3 6,7 17,4,32 13.8 / 51.8 9,2 3,6,22 26.4 / 53.2 7,2 17,7,34 69 84 1 116 132 148 164 69 84 1 116 132 148 164 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14.3 / 5.6 4, 31,4,5 13.7 / 51. 4,6 3,1,6 13.1 / 51.3 5,2,8,6 12.6 / 51.2 5,8 27,7,7 12.1 / 51.1 6,4 26,7,8 11.7 / 51. 7, 25,8,8 11.3 / 5.8 7,5 25,,9 COUNTER-FLOW PLATE 6/4 C O.A. - 7 /9% - R.A. 19 /5% 16.4 / 17.4 3,7 32,4,4 16.2 / 17.6 4,2 31,2,5 16.1 / 17.7 4,7 3,3,6 16. / 17.9 5,2 29,5,6 15.9 / 18. 5,6,8,7 15.8 / 18.1 6,1,1,7 15.7 / 18.2 6,5 27,6,8 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14.3 / 5.6 4,8 35,1,12 26.3 / 53.2 4, 15,,19 13.7 / 51. 5,7 34,1,14 26.4 / 53. 4,6 15,6,22 13.1 / 51.3 6,7 33,1,16 26.6 / 52.8 5,3 16,3,25 12.6 / 51.2 7,6 32,1,18 26.7 / 52.6 5,9 16,8, 12.1 / 51.1 8,5 31,3,2 26.8 / 52.4 6,4 17,2,31 11.7 / 51. 9,3 3,5,23 27. / 52.1 7, 17,7,34 11.3 / 5.8 1,1 29,8,25 27.1 / 51.9 7,5 18,,36 COUNTER-FLOW PLATE 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 16.4 / 17.4 4,4 35,4,11 25.8 / 57.1 4, 15,2,19 16.2 / 17.6 5,1 34,5,12 25.9 / 56.9 4,6 15,8,22 16.1 / 17.7 5,9 33,7,14 26. / 56.7 5,2 16,3,25 16. / 17.9 6,5 33,,16 26. / 56.6 5,8 16,8, 15.9 / 18. 7,2 32,3,17 26. / 56.4 6,3 17,1,3 15.8 / 18.1 7,8 31,7,19 26.1 / 56.3 6,8 17,5,32 15.7 / 18.2 8,4 31,2,2 26.1 / 56.2 7,2 17,8,34

Air Handling Unit Fidji 15 25 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 12 1 8 6 4 2 12 1 8 6 4 2 92 88 84 8 76 72 68 32 24 2 16 12 8 4 Fan ø 25 3V Max. airflow recommended (efficiency 8% on wheel) 4V Fan ø 3V 5V Counter-fl ow plate Wheel 1,5 mm Wheel 2, mm 6V 5V 7V 8V 9V 2 4 6 8 1 12 14 16 18 2 4V 6V 7V 8V 9V 2 4 6 8 1 12 14 16 18 2 2 4 6 8 1 12 14 16 18 2 F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) Wheel 1,5 mm Counter-fl ow plate Wheel 2, mm 2 4 6 8 1 12 14 16 18 2 UNITES TERMINALES ET MINI CTA (m 3 /h)

26 Air Handling Unit Fidji 3 Coils performances without considering heat recovery outlet 114 185 221 256 292 327 8/6 C Outdoor air - 7 C / 9% - 17,56 38,8,21-21,16 34,9,26-24,29 32,,3-27,22 29,6,33-29,84 27,6,36-32,35 25,9,39-34,64 24,5,42 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 16,2 34,7,39-9,9 14,5,47-2, 32,6,48-12,14 15,6,58-23,56 3,8,57-14,11 16,5,67-26,97 29,3,65-15,97 17,3,76-3,8 27,9,73-17,65 17,9,84-33,9 26,7,8-19,27 18,5,92-35,86 25,6,87-2,75 19,,99 Coils performances by considering heat recovery outlet 114 185 221 256 292 327 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,6 / 5,8 7,9 33,9,9 15,3 / 5,7 8,64 32,3,1 15,1 / 5,5 9,98 31,,12 14,6 / 5,9 11,37 29,8,14 14,2 / 51,4 12,63,8,15 13,8 / 51,7 13,87 27,8,17 13,4 / 52, 15,4 27,,18 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,6 / 5,8 8,29 37,,2 25,9 / 53, 7,16 13,6,34 15,3 / 5,7 1,43 35,8,25 26, / 53,1 8,85 14,5,42 15,1 / 5,5 12,36 34,8,3 26,1 / 53,2 1,38 15,2,5 14,6 / 5,9 14,4 33,8,35 26,2 / 53,3 11,86 15,8,57 14,2 / 51,4 16,29 33,,39 26,3 / 53,3 13,2 16,3,63 13,8 / 51,7 16,56 32,9,4 26,4 / 53,2 14,51 16,8,69 13,4 / 52, 2, 31,5,48 26,5 / 53,2 15,74 17,2,75 114 185 221 256 292 327 114 185 221 256 292 327 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,2 / 49,9 7,18 33,8,9 14,5 / 5,5 8,87 32,,11 13,9 / 5,9 1,39 3,5,13 13,3 / 51,2 11,86 29,2,14 12,8 / 51,4 13,21,1,16 12,2 / 51,4 14,59 27,,18 11,8 / 51,4 15,8 26,1,19 COUNTER-FLOW PLATE 6/4 C O.A. - 7 /9% - R.A. 19 /5% 16,6 / 17,2 6,8 34,3,8 16,3 / 17,5 8,3 32,7,1 16,1 / 17,8 9,6 31,5,12 15,9 / 18, 1,83 3,5,13 15,7 / 18,2 11,96 29,6,14 15,5 / 18,4 13,5,8,16 15,4 / 18,5 14,2,1,17 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,2 / 49,9 8,43 37,,2 26, / 53,4 7,27 13,7,35 14,5 / 5,5 1, 35,7,26 26,2 / 53,3 9,5 14,6,43 13,9 / 5,9 12,98 34,6,31 26,4 / 53,2 1,68 15,3,51 13,3 / 51,2 15,17 33,6,37 26,5 / 53, 12,15 15,9,58 12,8 / 51,4 17,22 32,7,42 26,7 / 52,8 14,87 17,1,71 12,2 / 51,4 17,61 32,5,42 26,8 / 52,6 14,94 17,,71 11,8 / 51,4 21,25 31,,51 26,9 / 52,4 16,17 17,4,77 COUNTER-FLOW PLATE 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 16,6 / 17,2 7,89 37,1,19 25,9 / 56,9 7,52 13,9,36 16,3 / 17,5 9,94 36,,24 26, / 56,5 9,27 14,8,44 16,1 / 17,8 11, 35,, 26,1 / 56,2 1,79 15,5,51 15,9 / 18, 13,56 34,1,33 26,2 / 55,9 12,25 16,1,58 15,7 / 18,2 15,22 33,4,37 26,3 / 56,8 13,77 16,7,66 15,5 / 18,4 15,36 33,3,37 26,3 / 55,5 14,77 17,,7 15,4 / 18,5 18,33 32,,44 26,4 / 55,4 16, 17,4,76

Air Handling Unit Fidji 3 27 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 14 12 1 8 6 4 2 14 12 1 8 6 4 2 92 88 84 8 76 72 68 4 36 32 24 2 16 12 8 4 Max. airflow recommended (efficiency 8% on wheel) Fan ø 6V 5V 4V 3V Fan ø 31 7V 4V 3V 5V Counter-fl ow plate Wheel 1,5 mm Wheel 2, mm 8V F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) Wheel 1,5 mm Counter-fl ow plate Wheel 2, mm 9V 25 5 75 1 125 175 2 225 25 275 3 325 35 6V 7V 9V 8V 25 5 75 1 125 175 2 225 25 275 3 325 35 25 5 75 1 125 175 2 225 25 275 3 325 35 25 5 75 1 125 175 2 225 25 275 3 325 35 UNITES TERMINALES ET MINI CTA (m 3 /h)

Air Handling Unit Fidji 45 Coils performances without considering heat recovery outlet 23 256 38 361 414 466 519 8/6 C Outdoor air - 7 C / 9% - 3,39 37,5,37-35,53 34,2,43-4,1 31,7,49-44,38 29,5,54-48,35 27,7,59-51,99 26,2,63-55,49 24,8,68 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 27,93 33,9,67-17,7 15,,81-33,62 32,,81-2,24 16,,96-38,81 3,4,94-23,9 16,7 1,1-43,76 29, 1,6-25, 17,4 1,23-48,43 27,8 1,17 -,29 18, 1,35-52,77 26,6 1,27-3,61 18,5 1,46-56,97 25,6 1,37-32,84 19, 1,57 Coils performances by considering heat recovery outlet 23 256 38 361 414 466 519 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,5 / 5,7 12,4 33,5,15 15,2 / 5,6 14,65 32,1,18 14,9 / 5,7 16,7 3,9,2 14,5 / 51,1 18,72 29,8,23 14,1 / 51,5 2,66,8,25 13,7 / 51,8 22,49,,27 13,4 / 52,1 24,23 27,2,29 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,5 / 5,7 14,44 36,5,35 26, / 53,1 12,42 14,,59 15,2 / 5,6 17,55 35,4,42 26, / 53,2 14,72 14,7,7 14,9 / 5,7 2,45 34,5,49 26,1 / 53,2 16,93 15,3,81 14,5 / 51,1 23,4 33,6,56 26,2 / 53,3 19,8 15,9,91 14,1 / 51,5 26,27 32,8,63 26,3 / 53,3 21,1 16,4 1,1 13,7 / 51,8 29,4 32,1,7 26,4 / 53,2 22,99 16,8 1,1 13,4 / 52,1 31,69 31,4,76 26,5 / 53,2 24,87 17,2 1,19 23 256 38 361 414 466 519 23 256 38 361 414 466 519 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14,9 / 5,2 12,65 33,3,15 14,2 / 5,7 15,14 31,7,18 13,7 / 51, 17,36 3,4,21 13,1 / 51,3 19,58 29,1,24 12,6 / 51,4 21,65,1,26 12,1 / 51,4 23,64 27,1,29 11,7 / 51,5 25,53 26,2,31 COUNTER-FLOW PLATE 6/4 C O.A. - 7 /9% - R.A. 19 /5% 16,5 / 17,3 11,92 33,9,14 16,3 / 17,5 14,4 32,6,17 16,2 / 17,7 15,9 31,5,19 16, / 17,8 17,72 3,6,21 15,9 / 18, 19,37 29,8,23 15,8 / 18,1 2,89 29,1,25 15,8 / 18,1 22,29,6,27 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14,9 / 5,2 14,81 36,4,36 26,1 / 53,4 12,6 14,1,6 14,2 / 5,7 18, 35,3,44 26,3 / 53,3 15,18 14,9,72 13,7 / 51, 21,48 34,3,52 26,4 / 53,1 17,4 15,5,83 13,1 / 51,3 24,74 33,4,6 26,6 / 52,9 19,71 16,1,94 12,6 / 51,4 27,87 32,5,67 26,7 / 52,7 21,74 16,6 1,4 12,1 / 51,4 3,9 31,7,75 26,8 / 52,5 23,65 17, 1,13 11,7 / 51,5 33,82 31,,82 27, / 52,3 25,75 17,4 1,23 COUNTER-FLOW PLATE 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 16,5 / 17,3 13,75 36,6,33 25,9 / 56,8 12,95 14,3,62 16,3 / 17,5 16,64 35,6,4 26, / 56,5 15,39 15,,73 16,2 / 17,7 19,24 34,7,46 26,1 / 56,2 17,6 15,6,84 16, / 17,8 21,83 34,,53 26,2 / 56,1 19,76 16,2,94 15,9 / 18, 24,22 33,3,58 26,2 / 55,9 21,58 16,6 1,3 15,8 / 18,1 26,46 32,7,64 26,2 / 55,8 23,27 17, 1,11 15,8 / 18,1,52 32,1,69 26,3 / 55,7 25,13 17,4 1,2

Air Handling Unit Fidji 45 29 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 14 12 1 8 6 4 2 14 12 1 8 6 4 2 92 88 84 8 76 72 68 24 2 16 12 8 4 Max. airflow recommended (efficiency 8% on wheel) Fan ø 31 4V 3V 3V 5V Fan ø 4 4V 6V 5V 7V Counter-fl ow plate Wheel 1,5 mm Wheel 2, mm 6V Wheel 1,5 mm Counter-fl ow plate Wheel 2, mm F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 8V 9V 5 1 2 25 3 35 4 45 5 55 7V 8V 9V 5 1 2 25 3 35 4 45 5 55 5 1 2 25 3 35 4 45 5 55 5 1 2 25 3 35 4 45 5 55 UNITES TERMINALES ET MINI CTA (m 3 /h)

3 Air Handling Unit Fidji 65 Coils performances without considering heat recovery outlet 316 384 452 521 589 657 725 8/6 C Outdoor air - 7 C / 9% - 45,98 36,2,56-52,38 33,5,64-58,25 31,3,71-63, 29,4, - 68,88 27,7,84-73,67 26,3,9 -,22 25,1,95 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 43,41 33,8 1,5 -,86 15, 1, - 5,72 32,2 1,22-3,97 15,8 1,48-57,57 3,8 1,39-34, 16,5 1,66-64,13 29,6 1,55-38,4 17,1 1,83-7,27,5 1,7-41,75 17,7 1,99-76,12 27,7 1,84-44,92 18,2 2,14-81,7 26,5 1,97-47,94 18,6 2,29 Coils performances by considering heat recovery outlet 316 384 452 521 589 657 725 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,4 / 5,7 18,37 32,6,22 15,2 / 5,6 21,1 31,4,26 14,9 / 5,7 23,72 3,4,29 14,5 / 51,1 26,34 29,4,32 14,2 / 51,4,73,6,35 13,8 / 51,7 31,14 27,8,38 13,5 / 52, 33,39 27,1,4 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,4 / 5,7 22,76 36,7,55 26, / 53,1 19,76 13,9,94 15,2 / 5,6 26,73 35,7,64 26, / 53,2 22,77 14,5 1,9 14,9 / 5,7 29,24 35,2,71 26,1 / 53,2 25,76 15,1 1,23 14,5 / 51,1 34,61 34,1,84 26,2 / 53,5,76 15,6 1,37 14,2 / 51,4 38,32 33,4,92 26,3 / 53,3 31,43 16,1 1,5 13,8 / 51,7 42,11 32,7 1,2 26,4 / 53,2 34,4 16,5 1,62 13,5 / 52, 45,68 32,1 1,1 26,5 / 53,2 36,6 16,9 1,75 316 384 452 521 589 657 725 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14,7 / 5,4 18,82 32,3,23 14,1 / 5,8 21,91 31,,27 13,6 / 51,1 24,79 29,8,3 13,1 / 51,3 27,59,7,33 12,7 / 51,4 3,18 27,8,37 12,2 / 51,4 32,79 27,,4 11,8 / 51,4 35,24 26,2,43 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14,7 / 5,4 23,42 36,6,56 26,2 / 53,4 2,23 14,,96 14,1 / 5,8 27,93 35,6,67 26,3 / 53,2 23,42 14,7 1,12 13,6 / 51,1 3,79 35,,74 26,4 / 53,1 25,76 15,1 1,23 13,1 / 51,3 36,56 33,8,88 26,6 / 52,9 29,61 15,8 1,41 12,7 / 51,4 4,61 33,1,98 26,7 / 52,8 32,39 16,3 1,54 12,2 / 51,4 44,76 32,3 1,8 26,8 / 52,6 35,2 16,7 1,67 11,8 / 51,4 48,7 31,7 1,17 26,9 / 52,4 37,79 17,1 1,8

Air Handling Unit Fidji 65 31 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 2 175 125 1 75 5 25 2 175 125 1 75 5 25 92 88 84 8 76 72 68 24 2 16 12 8 4 Fan ø 4 9V 8V 7V 6V 5V 4V 3V 4V 3V Max. airflow recommended (efficiency 8% on wheel) Fan ø 45 5V 6V 7V Wheel 1,5 mm Wheel 2, mm Wheel 1,5 mm Wheel 2, mm 8V F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 1 2 3 4 5 6 7 8 9V 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 UNITES TERMINALES ET MINI CTA 1 2 3 4 5 6 7 8 (m 3 /h)

32 Air Handling Unit Fidji 1 Coils performances without considering heat recovery outlet 458 581 73 826 949 171 1194 8/6 C Outdoor air - 7 C / 9% - 69,42 38,,85-81,54 34,7 1, - 92,42 32,1 1,13-12,48 29,9 1,25-111,81, 1,36-12,47 26,4 1,47-1,68 25, 1,57 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 63,48 34,2 1,53-38,91 14,8 1,86-76,85 32,3 1,85-46,38 15,8 2,21-89,16 3,7 2,15-53,15 16,6 2,53-1, 29,3 2,43-59,48 17,3 2,84-111,72, 2,7-65,38 17,9 3,12-121,99 26,8 2,94-7,88 18,4 3,38-131,84 25,8 3,18-76,12 18,9 3,63 Coils performances by considering heat recovery outlet 458 581 73 826 949 171 1194 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,5 / 5,7,34 33,8,34 15,2 / 5,5 33,63 32,3,41 14,9 / 5,7 38,5 31,1,47 14,5 / 51,1 43,25 3,,52 14, / 51,6 47,95,9,58 13,6 / 51,9 52,31,,63 13,3 / 52,1 56,39 27,3,68 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,5 / 5,7 32,85 36,7,79 25,9 / 53,1,4 13,9 1,34 15,2 / 5,5 4,14 35,6,97 26, / 53,2 33,75 14,6 1,61 14,9 / 5,7 47,2 34,6 1,13 26,1 / 53,2 38,99 15,3 1,86 14,5 / 51,1 53,91 33,8 1,3 26,2 / 53,3 44,4 15,8 2,1 14, / 51,6 6,88 32,9 1,47 26,3 / 53,3 48,79 16,3 2,33 13,6 / 51,9 67,45 32,2 1,63 26,4 / 53,2 53,25 16,8 2,54 13,3 / 52,1 73,66 31,5 1, 26,5 / 53,1 57,58 17,2 2,75 458 581 73 826 949 171 1194 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14,9 / 5,2,92 33,5,35 14,2 / 5,7 34,76 31,9,42 13,6 / 51,1 4,16 3,5,49 13,1 / 51,3 45,23 13,1 51,13 12,5 / 51,4 5,26,2,61 12, / 51,4 54,96 27,2,67 11,6 / 51,5 59,39 26,3,72 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14,9 / 5,2 33,69 36,6,81 26,1 / 53,4,73 14, 1,37 14,2 / 5,7 41,82 35,5 1,1 26,3 / 53,3 34,8 14,8 1,66 13,6 / 51,1 49,57 34,4 1,2 26,4 / 53,1 4,8 15,4 1,91 13,1 / 51,3 57,1 33,5 1,38 26,6 / 52,9 45,5 16, 2,17 12,5 / 51,4 64,56 32,6 1,56 26,7 / 52,7 5,27 16,5 2,4 12, / 51,4 71,73 31,8 1,73 26,9 / 52,5 55,29 17, 2,64 11,6 / 51,5,59 31,1 1,9 27, / 52,3 59,69 17,4 2,85

Air Handling Unit Fidji 1 33 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 22 2 18 16 14 12 1 8 6 4 2 22 2 18 16 14 12 1 8 6 4 2 92 88 84 8 76 72 68 24 2 16 12 8 4 Fan ø 5 7V 6V 5V 4V 3V Fan ø 45 9V 6V 5V 4V 3V Max. airflow recommended (efficiency 8% on wheel) 7V 8V Wheel 1,5 mm Wheel 2, mm 8V Wheel 1,5 mm Wheel 2, mm F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 9V 1 2 3 4 5 6 7 8 9 1 11 12 1 2 3 4 5 6 7 8 9 1 11 12 1 2 3 4 5 6 7 8 9 1 11 12 UNITES TERMINALES ET MINI CTA 1 2 3 4 5 6 7 8 9 1 11 12 (m 3 /h)

34 Air Handling Unit Fidji Coils performances without considering heat recovery outlet 713 884 155 1226 1397 1568 1739 8/6 C Outdoor air - 7 C / 9% - 16,87 37,5 1,3-123,51 34,5 1,51-138,68 32,1 1,69-152,68 3, 1,86-165,73,3 2,2-177,98 26,7 2,17-189,54 25,4 2,31 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 98,43 34, 2,37-6,89 14,9 2,9-116,89 32,3 2,82-71,27 15,8 3,4-134,12 3,8 3,24-8,84 16,5 3,85 -,32 29,4 3,63-89,74 17,2 4, - 165,64,2 4, - 98,8 17,8 4,68-18,18 27,1 4,35-15,95 18,3 5,5-194,4 26,2 4,68 -,41 18,7 5,41 Coils performances by considering heat recovery outlet 713 884 155 1226 1397 1568 1739 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15,4 / 5,7 44,45 33,8,54 15,2 / 5,5 51,69 32,5,63 14,8 / 5,8 58,79 31,3,71 14,4 / 51,2 65,54 3,2,79 14, / 51,6 72,3 29,2,87 13,6 / 51,9,3,4,95 13,3 / 52,1 84,14 27,6 1,2 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15,4 / 5,7 55,22 37, 1,26 26, / 53,1 44,74 13,9 2,13 15,2 / 5,5 62,32 36, 1,5 26, / 53,2 52,31 14,5 2,49 14,8 / 5,8 72,5 35,1 1,75 26,1 / 53,2 59, 15,1 2,85 14,4 / 51,2 82,41 34,2 1,99 26,2 / 53,3 66,94 15,7 3,19 14, / 51,6 92,11 33,5 2,22 26,3 / 53,2 73,63 16,2 3,51 13,6 / 51,9 11,63 32,7 2,45 26,5 / 53,2 8,88 16,7 3,86 13,3 / 52,1 11,6 32,1 2,67 26,5 / 53,1 86,35 17, 4,12 713 884 155 1226 1397 1568 1739 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14,7 / 5,4 45,47 33,5,55 14,1 / 5,8 53,56 32,,65 13,5 / 51,1 61,25 3,7,74 13, / 51,3 68,46 29,5,83 12,5 / 51,4 75,42,5,91 12, / 51,4 82,18 27,5,99 11,6 / 51,5 88,52 26,7 1,7 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14,7 / 5,4 53,71 36,9 1,3 26,2 / 53,4 45,8 14, 2,18 14,1 / 5,8 65,11 35,9 1,57 26,3 / 53,2 53,82 14,7 2,57 13,5 / 51,1 76,29 34,9 1,84 26,5 / 53,1 61,96 15,3 2,95 13, / 51,3 86,98 34, 2,1 26,6 / 52,9 69,1 15,9 3,29 12,5 / 51,4 97,51 33,1 2,35 26,8 / 52,7 76,57 26,8 52,7 12, / 51,4 17,91 32,3 2,6 26,9 / 52,5 83,12 16,8 3,96 11,6 / 51,5 117,79 31,6 2,84 27, / 52,2 89,32 17,2 4,26

Air Handling Unit Fidji 35 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 22 2 18 16 14 12 1 8 6 4 2 22 2 18 16 14 12 1 8 6 4 2 92 88 84 8 76 72 68 24 2 16 12 8 4 Fan ø 56 4V 3V Max. airflow recommended (efficiency 8% on wheel) 5V 4V 3V 2 Fans ø 45 5V 6V 7V Wheel 1,5 mm Wheel 2, mm 6V 8V Wheel 1,5 mm Wheel 2, mm 9V F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 7V 8V 9V 2 4 6 8 1 12 14 16 18 2 4 6 8 1 12 14 16 18 2 4 6 8 1 12 14 16 18 UNITES TERMINALES ET MINI CTA 2 4 6 8 1 12 14 16 18 (m 3 /h)

36 Air Handling Unit Fidji 2 Coils performances without considering heat recovery outlet 97 1193 1417 1641 1865 289 2244 8/6 C Outdoor air - 7 C / 9% - 134,3 34,6 1,64-153, 31,6 1,87-169,9 29,1 2,7-185,4 27, 2,26-199,7 25,2 2,44-213, 23,7 2,6-221,6 22,7 2,71 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 125,7 32, 3,3-74,1 16,1 3,53-147,1 3,1 3,55-85,4 17, 4,7-166,9,4 4,3-95,8 17,8 4,57-185,4 27, 4,47-15,3 18,5 5,2-22,6 25,7 4,89-114,1 19,1 5,44-218,8 24,5 5, - 122,4 19,6 5,84-229,5 23,8 5,54-127,8 19,9 6,9 Coils performances by considering heat recovery outlet 97 1193 1417 1641 1865 289 2244 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15.4 / 5.7 53,6 31,9,65 15.2 / 5.5 61,5 3,6,75 14.8 / 5.8 69,2 29,4,84 14.4 / 51.1 76,5,3,93 14.1 / 51.5 83,2 27,4 1,1 13.7 / 51.9 89,8 26,6 1,9 13.4 / 52. 94,4 26, 1,14 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15.4 / 5.7 64,2 35,2 1,55 26. / 53.1 53,1 14,9 2,53 15.2 / 5.5 75,5 34,1 1,82 26. / 53.2 61,2 15,6 2,92 14.8 / 5.8 86,9 33,1 2,1 26.1 / 53.2 69,2 16,2 3,3 14.4 / 51.1 97,9 32,2 2,36 26.2 / 53.3 76,8 16,8 3,66 14.1 / 51.5 16,8 31,5 2,58 26.3 / 53.3 84, 17,2 4, 13.7 / 51.9 118,6 3,7 2,86 26.4 / 53.2 9,7 17,7 4,32 13.4 / 52. 125,8 3,2 3,3 26.5 / 53.2 95,5 18, 4,55 97 1193 1417 1641 1865 289 2244 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 13.9 / 5.9 56,5 31,3,68 13.2 / 51.2 65,8 29,7,8 12.7 / 51.2 74,2,4,9 12.1 / 51. 82,5 27,1,99 11.6 / 5.9 9,1 26,1 1,9 11.2 / 5.7 97,3 25,1 1,18 1.8 / 5.6 12,4 24,5 1,24 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 13.9 / 5.9 68,4 35, 1,65 26.4 / 53.1 55,3 15,1 2,64 13.2 / 51.2 82,1 33,8 1,98 26.5 / 52.9 63,8 15,8 3,4 12.7 / 51.2 94,7 32,7 2,29 26.7 / 52.6 72,8 16,5 3,47 12.1 / 51. 17,4 31,7 2,59 26.9 / 52.4 81,3 17,1 3,88 11.6 / 5.9 119,5 3,8 2,88 27. / 52.1 88,4 17,5 4,22 11.2 / 5.7 13,8 29,9 3,16 27.1 / 51.8 95,2 18, 4,54 1.8 / 5.6 139,1 29,4 3,36 27.2 / 51.6 1,1 18,3 4,77

Air Handling Unit Fidji 2 37 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 22 2 18 16 14 12 1 8 6 4 2 22 2 18 16 14 12 1 8 6 4 2 92 88 84 8 76 72 68 24 2 16 12 8 4 2 Fan ø 5 7V 6V 5V 4V 3V 2 Fan ø 45 9V 6V 5V 4V 3V Max. airflow recommended (efficiency 8% on wheel) 7V 8V Wheel 1,5 mm Wheel 2, mm 8V Wheel 1,5 mm Wheel 2, mm F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 9V 2 4 6 8 1 12 14 16 18 2 22 24 2 4 6 8 1 12 14 16 18 2 22 24 2 4 6 8 1 12 14 16 18 2 22 24 UNITES TERMINALES ET MINI CTA 2 4 6 8 1 12 14 16 18 2 22 24 (m 3 /h)

38 Air Handling Unit Fidji 265 Coils performances without considering heat recovery outlet 1246 1534 1822 219 2397 2685 2973 8/6 C Outdoor air - 7 C / 9% - 173,5 34,9 2,12-197,9 31,8 2,42-219,9 29,3 2,68-239,9 27,2 2,93-258,4 25,4 3,15-275,7 23,9 3,36-291,8 22,5 3,56 45/35 C Outdoor air - 7 C / 9% 7/12 C Outdoor air 32 C / 4% - 163,5 32,4 3,94-97,7 15,8 4,66-191,6 3,6 4,62-112,8 16,8 5,38-217,6,9 5,25-126,6 17,6 6,3-241,7 27,5 5,83-139,2 18,2 6,64-264,4 26,2 6,38 -,9 18,8 7,19-5,7 25, 6,89-161,9 19,4 7,72-35,8 23,9 7,38-172,2 19,8 8,21 Coils performances by considering heat recovery outlet 1246 1534 1822 219 2397 2685 2973 WHEEL with 1.5 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 15.4 / 5.7 68,9 31,9,83 15.2 / 5.6 79,1 3,6,96 14.9 / 5.7 88,8 29,5 1,8 14.5 / 51.1 98,2,4 1,19 14.1 / 51.5 17,1 27,5 1,3 13.7 / 51.8 115,8 26,6 1,4 13.4 / 52.1 123,7 25,8 1,5 WHEEL with 1.5 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 15.4 / 5.7 84,2 35,6 2,3 26. / 53.1 7,7 14,7 3,37 15.2 / 5.6 99,1 34,5 2,39 26. / 53.2 81,5 15,3 3,89 14.9 / 5.7,7 33,5 2,74 26.1 / 53.2 92,2 16, 4,4 14.5 / 51.1 1,1 32,6 3,9 26.2 / 53.3 12,3 16,5 4,88 14.1 / 51.5 142,1 31,8 3,43 26.3 / 53.3 111,8 17, 5,33 13.7 / 51.8 155,9 31, 3,76 26.4 / 53.2 12,7 17,5 5,76 13.4 / 52.1 168,7 3,4 4,7 26.5 / 53.2 129,5 17,9 6,17 1246 1534 1822 219 2397 2685 2973 WHEEL with 2 mm fins spacing 6/4 C O.A. - 7 /9% - R.A. 19 /5% 14. / 5.9 72,3 31,3,88 13.3 / 51.2 84,4 29,7 1,2 12.7 / 51.3 95,6,4 1,16 12.2 / 51.1 15,9 27,2 1, 11.7 / 51. 115,8 26,2 1,4 11.2 / 5.8 125,4 25,2 1,52 1.8 / 5.6 134,3 24,3 1,63 WHEEL with 2 mm fins spacing 45/35 C O.A. - 7 /9% - R.A. 19 /5% 7/12 C O.A. 32 /4% - R.A. 25 /5% 14. / 5.9 89,2 35,4 2,15 26.3 / 53.1 72,9 14,8 3,47 13.3 / 51.2 17,2 34,2 2,59 26.5 / 52.9 85,3 15,6 4,7 12.7 / 51.3 124,3 33,1 3, 26.7 / 52.7 97, 16,3 4,63 12.2 / 51.1 14,4 32,1 3,39 26.8 / 52.4 17, 16,8 5,1 11.7 / 51. 156,2 31,2 3,77 27. / 52.1 117,6 17,3 5,61 11.2 / 5.8 171,7 3,3 4,14 27.1 / 51.9 126,8 17,8 6,5 1.8 / 5.6 186,3 29,6 4,49 27.2 / 51.6 135,4 18,2 6,46

Air Handling Unit Fidji 265 39 Pressure drops (Pa) Heat recovery effi ciency (%) Total static pressure (Pa) Total static pressure (Pa) 22 2 18 16 14 12 1 8 6 4 2 22 2 18 16 14 12 1 8 6 4 2 92 88 84 8 76 72 68 24 2 16 12 8 4 2 Fans ø 56 4V 3V Max. airflow recommended (efficiency 8% on wheel) 5V 4V 3V 3 Fans ø 45 5V 6V 7V Wheel 1,5 mm Wheel 2, mm 6V 8V Wheel 1,5 mm Wheel 2, mm 9V F9 bag fi lter (5%) F7 bag fi lter (5%) G4 fl at fi lter (5%) 7V 8V 9V 4 8 12 16 19 22 25 31 4 8 12 16 19 22 25 31 4 8 12 16 19 22 25 31 UNITES TERMINALES ET MINI CTA 4 8 12 16 19 22 25 31 (m 3 /h)

Non-contractual document. In a continuing effort to improve our products, we reserve the right to change specifications without previous notice. 4 Ed. 5//uk AIRCALO ZI Galaxie III 14 Avenue Cassiopée T: (33) 5 56 7 14 3316 Saint Médard en Jalles aircalo@aircalo.fr