SDS233T. Instant Match Transformer. Quick Connect Guide WITH

Similar documents
Installation guidelines for Models SDP134T Whale INSTANT MATCH with Bluetooth wireless technology Kit

Easi-Slide Exterior Utilities Sockets Water In Socket

Pump Shower Drainage Solutions

Installation guidelines for. Including. This booklet should be given to the customer after installation and demonstration. Models:

Installation guidelines for Models SDP303T Whale INSTANT MATCH PREMIUM Kit

A wide range of recreational vehicle exterior utilities sockets featuring unique Whale Easi-Slide Lid.

Dry-Deck 20 Installation Instructions

Installation guidelines for. Including. This booklet should be given to the customer after installation and demonstration. Models:

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. Installation Guide W2-A

INSTALLATION AND OPERATION MANUAL

i VAN Intelligent Control Panel

Installation guidelines for. This booklet should be given to the customer after installation and demonstration. Models: Digital Smoothflow Kit

i Van Intelligent Control Panel

The company and its products have built a reputation for quality, reliability and innovation backed up by excellent customer service.

Cyrene. Installation instructions. Fixed showerhead kit. Installers please note these instructions are to be left with the user.

Whale - Heat Whale's marine water heaters are designed with ease of use, safety and reliability at their core.

Dry-Deck 20 Installation Instructions

i Van Intelligent Control Panel The easy way to control your living environment Quick Guide

Mira Advance THERMOSTATIC ELECTRIC SHOWER. 8.7 and 9.8 kw. These instructions must be left with the user. User Guide W5-A

SIKA VK300 OR VK325 SERIES FLOW SWITCH Operating Manual

Mira Advance ATL. 9.0 and 9.8 kw. Important! This product is suitable for mains fed cold water only. Installation Guide

Showering Accessories

All Whale gas products must be installed by a Qualified Gas Engineer in accordance with the installation instructions and BS EN

Water Heater MkII WH1302 / WH1302B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

E-compact instant water heater CEX 9

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

INSTALLATION INSTRUCTIONS M SHOWER SLIDING RAIL

Technical Specification IRX

INSTALLATION INSTRUCTIONS M (MH

Installation and User Care Instructions

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

T550i power shower pump Installation and operating instructions

Douglas Lighting Controls. Bluetooth Fixture Controller & Sensor. Installation Manual BT-FMS-A. *Patent Pending. Installation Guide BT-FMS-A v7

Water. Heating. Connect with the Best. Electric Showers Power Showers 324. Shower Pumps 324. Beverage Water Dispensers

Bath Shower Mixer

M (MH 1228) M (ML 1228)

DESIGN SAFETY SIMPLICITY

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

SBW 250 Powered home cinema soundbar with wireless subwoofer, Bluetooth and HDMI

INSTALLATION INSTRUCTIONS M FLEETWOOD CROSS HANDLE 3-HOLE BASIN MIXER M FLEETWOOD LEVER 3-HOLE BASIN MIXER

everyday showers Electric Showers T75 8.5kW White/Chrome

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

51 Sandhill Gardens, Belfast, BT5 6FF

New Zip AquaFlo. Stainless steel cylinders for mains pressure hot water

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

SHOWER TRAY SELECTOR - LEVEL ACCESS SHOWER TRAYS

MTRA-FSP Level Control Relay. Installation & Operation Manual

AKW M11 DigiPump. Installation and User Care Instructions. Box contents for. 1x *15mm. *1x 22mm

CB-4070 BLACK ARCHIPELAGO PRESSURE BALANCE MIXING VALVE TRIM ONLY, TO SUIT M ROUGH

M INSTALLATION INSTRUCTIONS M FLEETWOOD SINGLE CROSS HANDLE PRESSURE BALANCE TRIM ONLY, TO SUIT M ROUGH

FSW300 Series Flow Switch

LUDA. Safe Showering For All LUDA. AKW Intelligent Shower

THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

Mira Sport Max with Airboost

Door Release Power Supply

Showering Accessories

Mobile App User Guide

Enhancing your Independence

ebrochure the information contained within this pdf document has been downloaded from the official Dimplex website

BOILING WATER Ready when you are

Safeguard Care Digilink

Combined electric boiler and domestic hot water store

Showering and Bathing

545,000 St Sampson. Local Market. Jules Rimet Sandy Hook. lovellsproperty.com Telephone

HOTFLO 10 / 15. Fitting Instructions and User Guide

Zip InLine Electronically controlled instantaneous water heaters

INSTALLATION AND USER INSTRUCTIONS

BFH range. Features. Base Unit Heater - BFH range

Grainfather Connect Control Box. Instructions

THE BRAND NEW UTILITY TAPS RANGE

Push Button Electronic Timer. 31VETR Series. Installation Instructions

Photo Please fit in text box

CEILING FED RISER RAIL KIT. Installation Guide. tritonshowers.co.uk/digital

4 Mountpleasant Drive, Newtownards, BT23 4WP. Viewing by appointment with & through agent

GRUNDFOS INSTRUCTIONS. Sololift2 C-3. Installation and operating instructions

ELINA concentric exposed thermostatic mixer valve

Dimplex ebrochure PDF

MEAS SENSOR TAG APP INSTALLATION GUIDE FOR ANDROID

Baxi Combi HE Range. Baxi Combi HE. Keeping Britain Warm

THERMOSTATIC SHOWER VALVE

Pressure Boosting Solutions

Mira Platinum Wireless Controller

The Offer. Hot Water Solutions Offered in - Natural Gas - Electric - LPG

WATER DOMESTIC PROPERTIES REGULATIONS FOR. Information guide for your home

Offers around 425, The Esplanade Holywood BT18 9JP. Tel: High Street, Holywood, BT18 9AE SALES LETTINGS PROPERTY MANAGEMENT

Embedded Linux with VAR-SOM-MX6 Course

Powerflow Unvented water heater

Dene Bath Shower Mixer

CT range. of shower, bathroom and whole house pumps

Dove Eco thermostatic bar mixer shower

Gas and Electric Water Heater. WH0802 or WH0802B or WI0802B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Lighting Control Solutions for Parking Facilities

STAINLESS STEEL STANDARD EQUIPMENT. Stainless steel sink. Taps and fittings with mixer for hot and cold water with elbow operation

The world s most advanced direct electric water cylinder

Gas Only Space Heater Mk II SH2201 / SH2211B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

2 Carnalea Glen, Carnalea, BANGOR, BT19 1XF. Viewing by appointment with & through agent

Installation instructions. RECOUP Retrofit+ Shower Waste Water Heat Recover unit

Mimosa dual control mixer shower Installation and operating instructions

Transcription:

SDS233T Instant Match Transformer Quick Connect Guide WITH

mbing of the Waste Pipe Whale Instant Match Transformer Flow Sensor Connections External flow sensors should be used for mixer showers. An external flow sensor may also be used for electric showers which are not hardwire compatible. Compatible flow sensors and their connections to the transformer are listed below. Sika Sensor Connection Blue Jumper - Sensor Position 2 Grey Jumper - Over run 30 Seconds Red Jumper - Pipe inlet 22mm Sika Sensor through the sensor is in the direction of the arrow on the sensor. Gems Sensor Connection There are two versions of Gems flow sensor: 1000 pulses per litre (ppl) and 2200 ppl. Blue jumper position 3 = 1000 ppl Blue jumper position 4 = 2200 ppl (shown below) Gems Sensor Blue Jumper - Sensor Position 4 Grey Jumper - Over run 30 Seconds Red Jumper - Pipe inlet 22mm through the sensor is in the direction of the arrow on the sensor.

Plumbing of the Waste Pipe Whale Instant Match Transformer Flow Sensor Connections Cont'd Grundfos (Venturi) Connection When connecting to the Grundfos Venturi sensor it is important to connect an earth wire from the Venturi sensor to the signal earth connection on Whale transformer (shown below). Venturi sensor Blue Jumper - Sensor Position 5 Grey Jumper - Over run 30 Seconds Red Jumper - Pipe inlet 22mm through the sensor is in the direction of the arrow on the sensor.

Whale Instant Match Transformer Flow Switch Connections In a situation where a hardwired connection with the shower cannot be established, or a suitable flow sensor has not been fitted, the Whale SDS233T Instant Match transformer can be used with AK1568 flow switch(es) to activate the pump. Electric Shower Settings Step 1: Turn Dip switch 2 to the 'ON' position. Step 2: Move red jumper to pipe size '1' for 15mm inlet pipe. Step 3: Move the blue jumper to increase or decrease the pump speed as required, using the table below as a guide. Step 4: Move the grey jumper to increase or decrease the pump overrun if necessary. Flow Switch Jumper Position Flow Rate (LPM) 1. 4.5 - As shown opposite 2. 5.0 3. 5.5 4. 6.0 5. 6.5 6. 7.0 7. 7.5 Dip Switches through the sensor is in the direction of the arrow on the sensor. Flow rates are nominal values only. This will vary depending on pipework. Blue Jumper - Sensor Position 1 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm

Whale Instant Match Transformer Flow Switch Connections Cont'd Mixer Shower Settings Step 1: Turn Dip switch 2 to the 'ON' position. Step 2: Move red jumper to pipe size '2' for 22mm inlet pipe. Step 3: Move the blue jumper to increase or decrease the pump speed as required, using the below table as a guide. Step 4: Move the grey jumper to increase or decrease the pump overrun if necessary. 30 is the recommended setting for use on mixer showers. Note: An additional flow switch is available in the AK1570 Mixer Valve Conversion kit (sold separately). Flow Switch x 2 Jumper Position Flow Rate (LPM) 1. 7.5 - As shown opposite 2. 8.0 3. 8.5 4. 9.0 5. 9.5 6. 10.0 7. 11.0 Dip Switches through the sensor is in the direction of the arrow on the sensor. Blue Jumper - Sensor Position 1 Grey Jumper - Over run 10 seconds Red jumper - Pipe inlet 15mm Flow rates are nominal values only. This will vary depending on pipework. Blue Jumper - Sensor Position 1 Grey Jumper - Over run 30 Seconds Red Jumper - Pipe inlet 22mm

mbing of the Waste Pipe Whale Instant Match Transformer Hardwired Connections The hardwired connection allows the transformer and shower to communicate by means of a physical wired connection, eliminating the need for an external flow sensor. Compatible showers and their pump connections may be found below. Mira Advance Flex Extra 1.1785.005 (J09N) Wired Connections to the WHALE INSTANT MATCH Transformer Ensure all LK settings are set to OFF for hardwired connection OFF ON 8 7 6 5 4 3 2 1 BEAB 43 DEG C 45 DEG C RESERVED 6L/MIN PUMP LK3 PUMP LK2 PUMP LK1 Flex Extra J09N Connection to Mira Advance Flex Extra J09N Shower Whale Transformer Settings CN13 Blue Jumper - Sensor Position 6 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm Brown Red Black N L TERMINAL BLOCK From Transformer

lumbing of the Waste Pipe Whale Instant Match Transformer Hardwired Connections Cont'd Triton Shower Connections and Settings Triton Safeguard + Omnicare Design, Omnicare Style, T150Z+ Wired Connections to the Whale Instant Match Transformer Blue Jumper - Sensor Position 4 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm Redring Selectronic WP (SEL85WP or SEL95WP) Redring Shower Connections and Settings Wired Connections to the Whale Instant Match Transformer Redring Shower Connections and Settings Blue Jumper - Sensor Position 4 Grey Jumper - Over run 10 Seconds Red Jumper - Pipe inlet 15mm

0845 0694 253 drainagesupport@whalepumps.com www.whalepumps.com @Whalecare Whale, 2 Enterprise Road, Bangor, Co. Down, BT19 7TA, N.Ireland Ref. 182.603_v1_0418 Copyright Whale 2018 - All rights reserved. Reproduction in whole or in part without permission is prohibited. WHALE and WHALE INSTANT MATCH are registered trademarks of Munster Simms Engineering Limited, Bangor, Northern Ireland trading as Whale. Whale s policy is one of continuous improvement and we reserve the right to change specifications without prior notice. Illustrations are for guidance purposes only. Neither the accuracy nor completeness of the information contained in this or any product literature is guaanteed by the Company and may be subject to change at its sole discretion. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks by Munster Simms Engineering Ltd (trading as Whale) is under licence. Other trademarks and trade names are those of their respective owners. MIRA is a registered trade mark of Kohler Mira Limited. TRITON is a registered trade mark of Triton Showers a division of Norcros Group (Holdings). REDRING is a registered trade mark of Redring Xpelair Group Limited. SIKA is a registered trade mark of Dr. Siebert & Kuhn GMbH & Co. KG GEMS is a registered trademark of Gems Sensors & Controls. GRUNDFOS is a registered trademark owned by Grundfos Management A/S or Grundfos A/S, Denmark.