MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE

Similar documents
Vertical Ring-section Pump WKTB. Type Series Booklet

CAP SERIES SEWAGE AND WASTE WATER PUMPS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Dean Pump High Temperature Chemical Process Inline Pumps

SL EX.4.51D

J SERIES. Technical Specifications. Centrifugal Pumps for J Series Condensate & Boiler Feed Pumps. Features

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Selfpriming Centrifugal Pumps. Type HZS/HZSA

SERIES ES BASE MOUNTED TURBINE PUMPS

MARINE. High efficiency pumps you can rely on

Horizontal Split Case Pumps Type U

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

CAST IRON IMPELLER B4JRMBH. TYPE B SINGLE STAGE CENTRIFUGAL PUMP Bearing Frame Mount TABLE I

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

1 1/8 Inch Centrifugal Pump Operation and Maintenance Guide

SL S.S.N.51D

The sealless FLUX F 424

Company name: Created by: Phone:

MCV - MCH - MCHZ Multistage pumps

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

Specially Designed Waste Water & Sewage Pumps

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Lenntech. Tel Fax bar. Multistage Pumps.

Technical Parameter: Suction Diameter: 40~250 mm Discharge Diameter: 25~200 mm

ETP Series - Self Priming Pumps

KUBOTA Double suction volute pump

Centrifugal Pumps acc. to DIN EN ISO 2858 with Shaft Sealing Type NCL

Selection V 1 INTRODUCTION PAGE V-2 V 2 SUMP/WELL PUMP SELECTION GUIDE PAGE V-3 V 3 CAN PUMP SELECTION GUIDE PAGE V-4

Centrifugal Pumps with Shaft Sealing and Priming Stage Type HZS / HZSA

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Sewage Pumps. KS - Channel Type Pumps W, WTS - Vortex Type Pumps

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

EBARA. Submersible Non-clog Pump Model DLFU Model DVFU Model DDLFU

CLOSED COUPLED CENTRIFUGAL PUMPS

Pump Program. fluids gases solids. edur.com. Developed and manufactured in Germany... since 1927

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

The sealless FLUX F 424

Centrifugal Pumps acc. to EN / ISO 2858 with Shaft Sealing Type NCL

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Light oil / kerosene burner

Full-line Product Overview

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

SUMY Catalogue. Product Line. Centrifugal Pumps СУМЫ SUMY ENGINEERING WORKS Ltd PUMPING EQUIPMENT DESIGN, MANUFACTURE AND SALE

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

SERIES 1600 Quality Design Features Assure Long, Trouble-Free Service

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Priming Aids ASH and AHP

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Types TMUB, TMUAH and. J Jockey Pumps

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Wilo IL Vertical Split-Coupled Inline Pumps

Group: LGA-LKA Engine: LGA 184 Drawing: A SPARE PARTS TABLE. POS. CODE DESCRIPTION Qty

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Inline-Pumps Type NCV /NCVL

CR A-F-A-E-HQQE 3x400/ HZ

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

Vertical In-line Self-Priming liquid ring Centripetal pump TYPE - STP

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

CR20-07 A-F-A-E-HQQE 3x400/ HZ

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

CombiChem. Centrifugal pumps according to ISO 5199 and ISO 2858 / EN (DIN 24256)

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

ProMinent ProMus Hydraulic Diaphragm Metering Pumps

Self-priming centrifugal pumps

DUPLEX CONDENSATE TANK SYSTEM

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

CNS CENTRIFUGAL MULTISTAGE WATER DESCALING PUMPS BB4 TYPE API 610 ENGINEERING FLOW SOLUTIONS

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

VRD. Sump pump for polluted liquids

SECTION FIRE PUMP AND CONTROLS

Mechanical Seal RG-4 stationary, double, liquid sealed

COOLING SYSTEM 1. Section V CONTENTS DATA AND SPECIFICATIONS. Page. Fluid Fan Drive (Silent Flite) 3. Water Pump 4. Radiator 5

TECHNICAL DESCRIPTION

489G DESCRIPTION CAST IRON UNITS BRONZE UNITS 316 STAINLESS STEEL UNITS. Maintenance. General Safety Information for 12 Volt DC Power

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

Oil burners fuel unit with solenoid valve

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y HVN. Double Suction, Heavy Duty API 610 Process Pump (BB2)

USER S MANUAL. VCU/VCUN Series CENTRIFUGAL FAN IN SCROLL CASING

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

SECTION STEAM CONDENSATE PUMPS

Metering & Thrust Gear Pumps. apompe.eu

CR A-F-A-E-HQQE 3x400/ HZ

SERVICE AND ASSEMBLY INSTRUCTIONS FOR CENTRIFUGAL PUMPS NPB

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

VALVES SECTION 15100

Goulds Trash Hog. Self-Priming Solids Handling Pumps

568X, 587X, 588X Series

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

Mechanical seals external, single or double, to DIN EN 12756

SERIES: WPT SELF-PRIMING CENTRIFUGAL PUMPS

SECTION DOMESTIC WATER PUMPS

Transcription:

MODERN TECHNOLOGIES AND LONG - TERM EXPERIENCE SVA ATEX AVAILABLE SELFPRIMING SIDE CHANNEL HORIZONTAL PUMPS SIGMA PUMPY HRANICE, s.r.o. Tovární č.p. 605, 753 01 Hranice I - Město, Czech Republic phone: +420 581 661 111, fax: +420 581 661 785 e-mail: sigmapumpy@sigmapumpy.com www.sigmapumpy.com 426 16.05 14.11

Applications The self priming side channel rotary pumps of SVA range are intended to pump clean liquids without solids up to 90 o C. The pumps equipped with mechanical seal are used for pumping flammable liquids such as diesel fuel, petrol, lamp oil, alcohol, kerosene, benzol mixtures, etc. of temperature class T1-T4, in Zone 1 or 2. The pump with gland packing can be used for pumping clean water or other clean liquids. It is possible to use these pumps also for pumping oils of kinematic viscosity up to 37 mm 2.s -1 (cst). Self priming ability is their main advantage (suction head up to 8m). Description The pumps of SVA range are of rotary, self-priming, sidechannel, horizontal design coupled with flexible coupling to driving motor. The pump consists of suction body, discharge body, suction insert, discharge insert, bearing housing, stuffing box cover, shaft with impellers and bearings. The impellers are of starrunner design. Both suction and discharge branch are always arranged upward, which mean that the pump is all the time filled with the pumped liquid. The suction body is equipped with filling plug and drain plug. The suction and delivery inserts including impellers in number depending on the pressure required are put between the suction body and the discharge body. This subassembly is clamped with clamping bolts. The shaft at suction side is supported on sliding bush (bearing) which is cooled with pumped liquid. The shaft at discharge side is supported on ball bearing. The shaft is sealed with gland rope packing, that is pressed with stuffing box cover (glands) and two bolts, or with mechanical seal. The sizes 20, 25, 32-SVA can be supplied in foot-design. The pump foot is part of the discharge pump body. The sizes 25 and 32-SVA can be also supplied in flange design. In such case they are mounted on a bellhouse together with flanged electric motor to make close-coupled design. SVA pump in foot design Direction of Rotation The pumps of SVA range are counterclockwise turning units viewing from drive side. Material The suction body, the discharge body, the suction and discharge inserts, the bearing housing and the stuffing box cover are made from grey cast iron. The impellers are made from brass and the shaft is made from steel or stainless steel in mechanical seal version. Range of delivery Range of delivery is given by the last number in pump denomination (valid for foot design): Range 1 - the pump only with bare end shaft Range 2 - the pump with complete flexible coupling Range 39 - the pump with complete flexible coupling and with common base plate for pump and electric motor, but without the motor Range 9 - the pump coupled with complete flexible coupling to electric motor mounted on common base plate. Accessories To customer order can be supplied counterflanges including joint material. ATEX For the pumps delivered to an explosion hazard area is manufacturer s flame-proof certificate for whole pumping unit available. To fulfill requirements for safe operation the pumps are equipped with temperature sensor as a protection against overheating and pressure switch as a protection against idle run. SVA pump in flange design 2

Informative Sectional Drawing of the Foot Pump-20,32-SVA with Mechanical Seal 1 2 3 4 5 6 7 12 15 23 24 25 43 Discharge body Suction body Discharge insert Suction insert Impeller Bearing housing Sliding bush Bearing cap Shaft Bearing Mechanical seal Stage gasket Mechanical seal cover Informative Sectional Drawing of the Foot Pump-20,25,32-SVA with Gland Packing 1 2 3 4 5 6 7 12 15 19 23 24 25 Discharge body Suction body Discharge insert Suction insert Impeller Bearing housing Sliding bush Bearing cap Shaft Stuffing box cover (glands) Bearing Gland packing Stage gasket 3

Dimensions Foot Design Pump Pump A B C D E F G H J K L M N O P R S T U V X Y Z 20-SVA-1 225 85 235 20-SVA-2 260 120 270 14 90 100 1 170 70 26 95 130 35 12 5 11,1 5 12 85 80 100 75 30 20-SVA-3 295 155 305 25-SVA-1 247 93 257 25-SVA-2 285 131 295 16 104 100 1 200 70 26 150 180 40 12 5 13,1 5 12 100 90 100 75 40 25-SVA-3 323 169 333 32-SVA-1 267 112 279 32-SVA-2 305 150 317 16 103 100 1 1/4 224 65 28 160 200 40 12 5 13,1 5 16 112 100 115 90 40 32-SVA-3 343 188 355 4

Dimensions Close-coupled Pump with Standard Motor Pump A B C D E F 25-SVA-1 98 104 561 G1 202 10 25-SVA-2 136 142 656 G1 202 10 25-SVA-3 174 180 694 G1 202 10 32-SVA-1 103 118 575 G1 1/4 212 12 32-SVA-2 141 156 670 G1 1/4 212 12 32-SVA-3 179 194 708 G1 1/4 212 12 Performance data Pump size 20-SVA-1 Q H Pi Version with m l.s -1 m.w.c. kw mechanical seal kg 13 9 0,25 0,22 20-SVA-2 25/25 0,33-0,58 27 17 0,44 0,34 yes 10 20-SVA-3 39 21 0,55 0,40 12 25-SVA-1 28 11 0,68 0,35 13,5 yes, only for closecoupled design 25-SVA-2 25/25 0,50-1,00 52 20 1,18 0,65 16 25-SVA-3 78 30 1,74 0,94 18,5 32-SVA-1 DN branches suct./disch. 31 12 0,98 0,60 32-SVA-2 32/32 0,83-1,33 63 28 1,92 1,20 yes 17,5 32-SVA-3 91 38 2,65 1,65 20,5 The date above are valid for water of temperature t = 20 C, density ρ = 1000 kg.m -3, revolutions n = 1450 R.P.M. Q... flow capacity Pi... pump power input (when pumping clean liquid of density ρ = 1000 kg.m -3 ) H... total head m... weight of pump with bare end shaft 8 14,5 5

Informative Pumps Performance Chart Descriptions, data and features contained in this document are not binding. We reserve the right to make any necessary modifications without prior notice. 6