K 60 D 070 Z KIT RÉGULATION SYSTÈME POUR POMPE À CHALEUR INVERTER AVEC CHAUFFAGE D APPOINT ÉLECTRIQUE

Similar documents
M2Z M NOTICE D INSTALLATION INSTALLATION INSTRUCTION MANUALE D INSTALLAZIONE MANUAL DE INSTALACIÓN AUFSTELLUNGS- HANDBUCH INSTRUÇÕES DE INSTALAÇÃO

K 60 D 066 Z KIT RÉGULATION POUR POMPE À CHALEUR EN RELÈVE DE CHAUDIÈRE APPLICATION 1 ZONE RADIATEURS / ACTION TOUT OU RIEN

K 60 D 067 Z KIT RÉGULATION POUR POMPE À CHALEUR EN RELÈVE DE CHAUDIÈRE APPLICATION 1 ZONE RADIATEURS OU PLANCHER - ACTION PROPORTIONNELLE

CSAGV 27 / 80. GROUPE FRIGORIFIQUE A CONDENSATION PAR AIR HELICOÏDE Fluide réfrigérant R 407 C

PHT 13 / 16. Pompe à chaleur haute température avec équipement hydraulique (chauffage seulement) - Fluide réfrigérant R 407 C

AOF CLIMATISEUR MONOBLOC A CONDENSATION A EAU SINGLE PACKAGED ROOM AIR CONDITIONER WITH WATER COOLED CONDENSER

PHRT 9 / 18 PHRT 12 PHRT 16 PHRT 18. Pompe à chaleur avec équipement hydraulique - Fluide réfrigérant R 410 A

This air conditioner uses the new refrigerant R410A.

PHTJ 14 / 19. Pompe à chaleur haute température avec équipement hydraulique (chauffage seulement) - Fluide réfrigérant R 407 C

K 60 D 068 Z KIT RÉGULATION POUR POMPE À CHALEUR EN RELÈVE DE CHAUDIÈRE APPLICATIONS 2 ZONES MIXTE (PLANCHER + RADIATEURS) OU 2 ZONES PLANCHER

CSCF - LL. ensemble de RéFRigéRatioN SPLit CoNSoLe. Fluide réfrigérant R 410 A

ENSEMBLE DE CONTRÔLE ET RÉGULATION POUR SYSTÈMES DE CHAUFFAGE / CLIMATISATION AVEC POMPE À CHALEUR INVERTER ET APPOINT ÉLECTRIQUE.

CONTROL UNIT FOR HEATING/COOLING SYSTEMS WITH INVERTER SPLIT HEAT PUMP AND ELECTRICAL BACK UP. APPLICATIONS:

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

SYSTÈMES DE CHAUFFAGE / CLIMATISATION AVEC POMPE À CHALEUR EN RELÈVE DE CHAUDIÈRE HEATING / COOLING SYSTEMS WITH HEAT PUMP IN RELIEVING A BOILER

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

KPSW CONSOLE TERMINAL UNIT

SIRIO Contatore di energia Energy meter

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

SYSTÈMES DE CHAUFFAGE / CLIMATISATION AVEC POMPE À CHALEUR SPLIT INVERTER EN RELÈVE DE CHAUDIÈRE

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

KM300 Carbon Monoxide Detection System Installation Manual

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Instruction Manual. Electronic gas and smoke detector GRM

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

Custom Install INSTALLATION GUIDE GUIDE PRODUIT & INSTALLATION MANUALE DEL PRODOTTO E DI INSTALLAZIONE PRODUKT- UND INSTALLATIONSHANDBUCH

Outside Humidity and Temperature Sensor

Constant Temperature Waterbaths

QAW70. Room Unit. Building Technologies. for use with heating controllers

Frost Protection Thermostat

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

THERMAL RADIATORS INSTALLATION INSTRUCTIONS AND USER GUIDE RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF14P RF3E RF4E RF5E RF6E RF8E RF10E RF12E RF14E

SPA DE USO PRIVADO SPA FOR PRIVATE USE SPA POUR UN USAGE PRIVÉ SPA FÜR PRIVATE NUTZUNG SPA PER USO PRIVATO SPA PARA USO PRIVADO SPA VOOR PRIVE-GEBRUIK

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

NOtice. (Etiquette signalétique) (Data label) AOF AOF 15 AOF 25 AOF 55. single PAcKAGed ROOM AiR conditioner. Octobre F.

Technical Data Manual

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

WINDSHEAR STORM and WINDSHEAR STORM DELUXE MODEL NO: 98778/98780

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets with screw connection (16/32 A)

Instructions for installation and use RE/I. Industrial electric heater for swimming pool

Dual Input ph/conductivity Analyzer

Installation manual extra-low-voltage socket outlets for panel- and surface-mounting

USE. Steam dispensing. n 4 holes. How to access the programming function

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Installation manual surface mounting plugs and socket outlets, panel mounting plugs and socket outlets QUICK-CONNECT (63 A)

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

TRONIC 6000C WH17 & WH27 Electric Tankless Water Heaters

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

ACS-30-EU-EMDR- 10-MOD

Installation and user manual for the BiWire / Conventional Repeater Panel

1. Information before installation General terms of delivery, storage and transport

Installation Instructions VITOTRONIC 200

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

ACH1. Water Heating Unit Control Box INSTALLATION MANUAL FOR INSTALLERS

Climapro 2. Installation. wireless room thermostat without receiver.

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

INSTALLATION AND MAINTENANCE MANUAL BLITZ FD_

Proliphix Thermostat Installation Guide. Release 2.0

Heliox UV. Model Heliox LP P Heliox LP P Heliox LP P300

Installation manual plugs and connectors QUICK-CONNECT (63 A)

/04.14_00. De Longhi Appliances via Seitz, Treviso Italia

Zweifarbdesigns Two-colour designs Designs bicolores Design bicromatici

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

Remote Vacuum Sensor and Variable Speed Vacuum Pump Control Manual. Version Date - June Part Number

ADL DYNAMIC STORAGE HEATERS INSTALLATION INSTRUCTIONS AND USER GUIDE ADL 2012 ADL 3018 ADL 4024 ADL 5030

Room Temperature Sensors

Light Level Detector, Surface Mount 5754PE. Installation Instructions

Wireless Outdoor Air Reset Adaptor PN:

/9308 External Battery Chargers Installation Instructions

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

ACS-30-EU-VIA-DU-20-MOD

CFS30, CFS60, CFS90 & CFS120 Standard Wall Mounted Fan Heater

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

NL Installatievoorschriften p. 3. FR Instructions d installation p. 5. DE Montageanleitung p. 7. EN Operating and installation Instructions p.

T8000 Series T8600 MODBUS Touch Screen Thermostat

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

Gebrauchsanweisung User manual 使用手冊マニュアル

Technical Instructions Document No P25 ET September 28, ET 141 Electric Surface Mounted Thermostat.

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

OWNER S MANUAL Venstar Inc. 08/07

Dual Input ph/orp Analyzer

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

Digital Electronic Thermostat With RF

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

OPERATING AND INSTALLATION MANUAL

910 Series Single-point heat-tracing control system

SONAR PROCESS MONITORING SYSTEM SUPPLEMENT FOR ATEX CLASS I, ZONE 2 SAFETY

INSTRUCTIONS. OJ-DV-Relay-Module. OJ Drives A DRIVES PROGRAMME DEDICATED TO VENTILATION SOLUTIONS. Optional module for OJ-DV motor controller

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Type Sup 037RG. Errata: Descaling. These instructions replace those reported in the manual.

WHE 2.24 / WHE 2.24 FF

Laser Distance Sensor Type M Analog-Output

Semi flush-mount room thermostats

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

Transcription:

(tiquette signalétique) NOTIC INSTALLATION INSTALLATION INSTRUCTION MANUAL INSTALLAZION MANUAL INSTALACIÓN AUFSTLLUNGS- HANUCH INSTRUÇÕS INSTALAÇÃO F I P K 60 070 Z KIT RÉGULATION SYSTÈM POUR POMP À CHALUR INVRTR AVC CHAUFFAG APPOINT ÉLCTRIQU SYSTM CONTROL KIT FOR INVRTR HAT PUMP WITH LCTRIC SUPPORT HATR KIT RGOLAZION SISTMA PR POMPA I CALOR INVRTR CON RISCALAMNTO LTTRICO INTGRATIVO KIT RGULACIÓN SISTMA PARA OMA CALOR INVRTR CON CALNTAMINTO COMPLMNTO LÉTRICO SYSTMRGULIRUNGSST FÜR WÄRMPUMP INVRTR MIT LKTRISCHR ZUSATZHIZUNG KIT RGULAÇÃO SISTMA PARA OMA CALOR INVRTR COM AQUCIMNTO COMPLMNTO LÉCTRICO écembre 2010 10 11 566 - F..I...P - 00

MARKING This product, marked with the symbol, complies with the essential requirements of the following irectives: - Low voltage No. 2006/95/C. - lectromagnetic Compatibility No. 2004/108/C. NOT: This symbol mark and recycle system are applied only to U countries and not applied to the countries in the other area of the world. Your product is designed and manufactured with high quality materials and components which can be recycled and reused. At end of livetime, it should be eliminated separately from your household waste. Please dispose of this equipment at your local community waste collection / recycling centre. In the uropean Union there are separate collection systems for used electrical and electronic products. Please help us to conserve the environment we live in! CONTNTS 1 - Purpose - Use........................................ 2 2 - Precautions.......................................... 2 3 - Composition......................................... 3 4 - Operating principle.................................... 3 5 - Installation........................................... 4 6 - Connections on the heat pump........................... 4 7 - Starting - Maintenance................................. 7 1 - PURPOS - US Control kit designed to control heating installations with heat pump and electric support heater for residential purposes within the scope of applications meant for TCHNIL. See technical control file enclosed with kit. 2 - PRCAUTIONS IMPORTANT Installation, commissioning and maintenance of this kit must be performed by qualified and authorised personnel, in accordance with current standards and recognized trade practices. efore doing any work on the installation, make sure it is switched off and all power supplies locked out. Consult the manuals of the system's various components: - heat pump, - control kit, - 2 zones module, if any, - HW tank, if any, as well as the technical control file supplied with the kit. CAUTION efore each start-up operation, make sure that the it is properly configured for the application. 2

3 - COMPOSITION The kit includes: - A control box to be installed in the comfort zone (see paragraph 5.1). - An outside temperature sensor unit placed on the facade of the building (see paragraph 5.2). Control unit: - Plastic wall-mounted control unit. - imensions: height = 128 mm width = 86 mm depth = 34 mm - Colour: White - Class lll -IP30 Outside temperature sensor: - Installed in a box with cable gland. Note: This sensor must be installed in a location that is sheltered from inclement weather. See details in paragraph 5.2. 4 - OPRATING PRINCIPL The kit is designed allow complete installation control from the parameterable control unit. The orders given by the control unit are transmitted (via a two-wire communication line (US)) to installation elements. The heat pump and its electric support heater are controlled according to a setpoint resulting from the water temperature calculated according to a water law (according to the outside temperature). Priority is given to thermodynamic heating. See operating details in the technical control file supplied with this kit. The system control kit K60070Z is appropriate for standard applications using heat pump with electric support heater: - 1 Floor Zone, - 2 Floor Zones, - 1 Terminal Units Zone, - 1 Radiators Zone (with or without omestic Hot Water), - 2 Mixed Zones, Floor + Terminal Units, - 2 Mixed Zones, Floor + Radiators. K60070Z 3

5 - INSTALLATION 5.1 - CONTROL UNIT INSTALLATION As the control unit is equipped with a temperature sensor, it must be installed in a location that is representative of the temperature of the comfort zone. Wall mounting: the unit must not be installed in corners, on shelves or behind curtains, near sources or heat or directly exposed to sunlight. The unit should be installed approximately 1.5 m above the floor. Open the unit by removing the lower screw and secure the base to the wall (mounting holes, item 1). Open the protective cover (screw 2) and connect the US link to the control board (see paragraph 6). Mini. 20 20 cm cm 1.50 m ase 1 Control unit 2 Rear view Fit the control unit back on its base. 5.2 - INSTALLATION OF TH OUTSI TMPRATUR SNSOR This sensor must be located outside in a location that is representative of the temperature to be measured (on a wall facing North / North-west) and located away from parasitic heat sources (chimney, thermal bridge, etc..) and sheltered from inclement weather (under a roof overhand, for example). Connection as per paragraph 6. 6 - CONNCTIONS ON TH HAT PUMP 6.1 - PRINCIPL The electrical conduits must be fixed. Pass the cables through the glands at the rear of the heat pump. The connection cables are not supplied. Caution: To avoid problems related to electromagnetic disturbances, do not route these cables near power cables. Particular attention should be paid to the 230 VAC pilot wire. 4

Outside air temperature C Control unit With built-in ambient temperature sensor. To be installed in zone 1. Load shedding (if any) System board A1 Power board A3 Control board A2 Installation water return temperature Installation water outlet temperature Possible connections to be made depending on the applications PHRI Control by pilot wire for 2 nd zone (if any) with electric convectors. Application: 1 FLOOR ZON or 1 TRMINAL UNIT ZON or 1 RAIATORS ZON CO signal to remote controls. For the terminal unit zone. Application: 1 TRMINAL UNIT ZON or 2 MIX ZONS US connection: towards M2Z 2 zones module for application: 2 FLOOR ZONS or 2 MIX ZONS towards HW tank for application: 1 RAIATORS ZON WITH HW. F C Communication line (US) - 2-conductor shielded cable, minimum size 1 mm 2 with grounded shielding on heat pump side (*). - Total length of the US connection: 40 meters (control unit connections + 2-zone module, if any or HW preparation kit, if any ). - To be connected to the (+) and (-) terminals if terminal strip. (*) Refer to the ground shielding principle in paragraph 6.4. Outside temperature sensor - 2-conductor cable, min. size 0.5 mm 2. - Maximum length 25 meters. - To be connected to the (S13-1) and (S13-2) terminals if terminal strip. - Note: This sensor must be located outside in a location that is representative of the temperature to be measured (on a wall facing North / North-west) and located away from parasitic heat sources (chimney, thermal bridge, etc..) and sheltered from inclement weather (under a roof overhand, for example). See paragraph 5.2. lectric support heater load shedding signal (if any) - Two possibilities: 1) y a "remote info" signal coming from the electrical utility meter: 1 twisted pair (6/10) cable with shielding (shielding grounded on heat pump side). 2) y a good quality, potential-free external contact. - Contact closed = load shedding of the electric support heater. - 2-conductor cable, min. size 0.5mm 2. - Maximum length 25 meters. - To be connected to the system board A1. CO signal for remote controls (if any) - In order to send reduced mode orders (co or standby) to the terminal unit remote control units in the case of applications such as 1 terminal unit zone or 2 mixed zones. - In the form of a potential-free contact which can used in VLV (Very Low Voltage), 2A max. - To be connected to the system board A1. - Note: The contact can control up to 10 RCC10 (70250051) or RCC20 (70250052) type controls. Consult the terminal unit and remote control documentation to connect this contact. 5

F Pilot wire for electric convectors (if any) - The pilot wire sends shut-down, "anti-freeze" (long term absence) or "conomy" mode instructions to the electric convectors in zone 2, and possibly in the case of 1 floor zone or 1 terminal unit zone applications. Convector control (not supplied) must be adapted to receive this type of signal (standard GIFAM 4). Consult the manual of the electric convectors. - 230 VAC signal from the system board A1. - 1.5 mm 2 single-pole cable adapted for the operating voltage. - Max. number of convectors controlled by the pilot wire: 20. - To be connected to the system board A1. - Note: The electrical power supplied to the convectors must be the same as that of the heat pump. 6.2 - HAT PUMP CONNCTION IAGRAM - Route the pilot wire (230 V) separately from the other control connections. S1 C S2 C S3 4 3 2 1 A1 C A2 C A3 H1 H2 H3 5 4 3 2 1 4 3 2 1 5 4 3 2 1 3 2 1 CN8 CN7 CN6 CN5 System board A1 230V CN1 CN2 CN3 CN4 1 2 3 1 2 3 4 1 2 3 4 1 2 3 4 N U FP R1 R2 R3 C 1 2 T+ T- 1 2 + - F lectrical utility meter Or Pilot wire lectric convectors (if any) CO signal (if any) Load shedding (if any) XA 21 Power supply (*) C Outside temperature sensor Maintenance keypad / display unit (See paragraph 6.3) US connection to 2-zone module (if any) or HW tank (if any) (*) Jumper (included on the terminal strip) for switching from 4 kw electric support heater (factory wired) to 6 kw. Control unit 6

6.3 - MAINTNANC KYPA / ISPLAY UNIT CONNCTION A specific keypad / display unit can be connected for maintenance and troubleshooting operations. See maintenance manual. Caution: This keypad / display unit must not be used for the installation's normal operation. Terminal R1 R2 lack White 6.4 - ROUTING OF CALS To prevent problems resulting from electromagnetic interference, control cables must not be routed near 230 VAC cables. Particular attention should be paid to the 230 VAC pilot wire. lectrical connection conduits must be fixed. ROUTING OF HAT PUMP CALS Route the cables through the cable glands located at the back of the unit. Use the cable clamps mounted on the lower edge of the electrical panel to secure the cables. Ground the shielding of the communication line (US) cable with the metal clamp secured to the box panel. Cable clamp Shielding Metal clamp ox panel 7 - STARTING - MAINTNANC Refer to the heat pump installation instructions. 7

F I P Par souci d'amélioration constante, nos produits peuvent être modifiés sans préavis. ue to our policy of continuous development, our products are liable to modification without notice. Per garantire un costante miglioramento dei nostri prodotti, ci riserviamo di modificarli senza preaviso. n el interés de mejoras constantes, nuestros productos pueden modificarse sin aviso prévio. Unsere Produkte werden laufend verbessert und können ohne Vorankündigung abgeändert werden. Com o objectivo de uma melhoria constante, os nossos produtos podem ser modificados sem aviso prévio. R.. 28 Reyrieux P 131 01601 Trévoux CX France Tél. 04 74 00 92 92 - Fax 04 74 00 42 00 Tel. 33 4 74 00 92 92 - Fax 33 4 74 00 42 00 R.C.S. ourg-en-resse 759 200 728