Lenntech. Tel Fax

Similar documents
MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

QuadraFlow Cooling Tower

ENGINEERING AND SPECIFICATIONS. Marley MC FLUID COOLER

Evaporative Condensers

Lenntech. Tel Fax Engineering Data & Specifications

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

ENGINEERING DATA AND SPECIFICATIONS. MH Fluid Cooler

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

MH fluid cooler. engineering data and specifications

SECTION COOLING TOWERS

Closed Circuit Cooling Towers

CONTENTS. B. System Design and Performance Requirements

Closed Circuit Cooling Towers

Aquatower STEEL COOLING TOWER. engineering data and specifications

CTI Sponsored Educational Program

Engineering Specifications for HXV Closed Circuit Hybrid Cooling Tower

PAPER NO: ANDREW RUSHWORTH

Michigan State University Construction Standards. COOLING TOWERS Page SECTION COOLING TOWERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Products and Services

Evaporative Condensers

JCseries EVAPORATIVE CONDENSER. engineering data

How about Savings in Time, Money, Energy and Longer Life?

ENGINEERING DATA AND SPECIFICATIONS. Marley Aquatower FIBERGLASS CROSSFLOW COOLING TOWER

Product Introduction...E35. Benefits...E37. Construction Details...E39. Custom Features & Options...E41. Accessories...E44. Engineering Data...

Efficient, Long Lasting Evaporative Condensers

Cold Weather Operation Of Cooling Towers

/ Aquatower Fiberglass Cooling Tower /

QuadraFlow cooling tower. engineering data and specifications

Series 5000 Industrial Modular Cooling Tower. Series 5000 Cooling Tower. engineering Data

Un-Used Series CXV Evaporative Condenser

Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

SECTION COOLING TOWERS

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

Closed Circuit Coolers Technology for the Future, Available Today

Reliable products with long-term, low cost of ownership

XLP2 Evaporative Condensers

Product Introduction...E11. Benefits...E13. Construction Details...E15. Custom Features & Options...E19. Accessories...E23. Structural Support...

FEATURES AND BENEFITS

Baltimore Aircoil RCF CLOSED CIRCUIT COOLING TOWERS. ...because temperature matters COUNTERFLOW INDUCED DRAFT

/ Recold J Series / Designed To Perform. Built To Last.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

CXVB Evaporative Condenser TABLE OF CONTENTS E112 ENGINEERING DATA CXVB EVAPORATIVE CONDENSERS E144 STRUCTURAL SUPPORT CONSTRUCTION DETAILS

VTL Open Cooling Towers... B98. Benefits... B100. Construction Details... B102. Custom Features and Options... B103. Accessories...

HYBRID ADIABATIC Cooling System

Closed Circuit Hybrid Cooling Towers. Product Introduction...E61. Benefits...E63. Construction Details...E65. Custom Features & Options...

Layout. Guidelines11. Chapter 11: Layout Introduction

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Fibreglass reinforced polyester (FRP) water collection basin with sloping base and smooth internal finish with rounded corners for easy cleaning.

MECHANICAL SERVICES 101. Ian White

CROSSFLOW REPLACEMENT FILL KITS. Replacement Fill Kits Specifically Designed for All Types of Crossflow Cooling Towers (BAC, Marley, etc.

Product Introduction...D85. Benefits...D87. Construction Details...D89. Custom Features & Options...D91. Accessories...D93. Engineering Data...

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

DESIGN GUIDELINES SECTION HVAC

TM Series. Induced Draft, Counter Flow Optional Accessories

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

/ MH Fluid Cooler / User Manual F

Direct Fired Heater Model AD Specification

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

Closing the Loop What s best for your system?

Appendix 13. Categories of Cooling and Heating systems

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

Evaporative Cooling products

KIC Air Curtains. Technical Guide

TOPAZ ADIABATIC COOLER

Fluid Cooler Fan and Pump control panel

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Series 1500 Cooling Tower Specification

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

Evaporative Cooling Products

GIRTON CABINET WASHER MODEL 794A

Square Ceiling Diffusers : All extruded aluminum constructions. Opposed blade damper is adjustable from face of diffuser. Available in square and

EqUIPMENT LAYOUT MANUAL

Maximum Capacity and Highest Quality to the. Lowest Shipping Costs! Engineered to Deliver the. Worldwide Market - with the.

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

TYPICAL CPA SPECIFICATIONS

MAC-120HE-03 Air-Cooled Chiller

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Bulletin 241B. Mark owned by the Cooling Technology Institute

Paragon. Induced Draft, Counter Flow Optional Accessories

Semi-Instantaneous Indirect Fired Water Heater

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Linear Floor Heaters

LSFG-8 LOW SOUND & SLSFG-10 SUPER LOW SOUND TOWER FEATURES

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

NJWEA TECH TRANSFER MARCH 1, 2016

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

2009 IECC Commercial Mechanical Requirements

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Transcription:

Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289 MC Fluid Cooler

Unmatched reliability Heavy-duty construction, high performance design and our five-year mechanical warranty ensure consistent, fully-rated cooling over a wide range of flow and temperature requirements.

What every premium installation demands Reliability and performance. When specifying components for high-end applications, they re the most important considerations for your cooling solution. And the Marley MC Fluid Cooler delivers, with low noise and a space-saving footprint for installation practically anywhere. Suitable for all critical indoor and outdoor applications, the MC Fluid Cooler provides these built-in performance advantages: Low energy consumption Low noise Smaller footprint Ease of maintenance Fluid cooling equipment minimizes the energy consumption of the entire system because it provides lower operating temperatures saving money while conserving natural resources. Centrifugal fans, a fully-enclosed falling water area and optional sound attenuation create one of the quietest tower configurations on the market. Forced-draft counterflow design requires considerably less plan area than crossflow towers. An extra large entry panel makes the interior of the unit easy to access for service and maintenance. For even greater access, the motor and drive are located outside the plenum area near the grade.

Features of the MC Fluid Cooler High velocity, low drift eliminators guarantee drift rates <0.005% Distribution system access via an optional ladder or platform Extra large rectangular access doors for easy maintenance Optional S300 construction for extended life 5-year mechanical warranty for fans, fan shafts bearings, sheaves and mechanical equipment supports

POPULAR OPTIONS Welded stainless steel collection basin for extra protection, all collection basin parts exposed to the circulating water, including structural members projecting into the basin (plus attaching hardware and all basin options) are heavy-gauge series 300 stainless steel. Electric basin heater incorporating a stainless steel electric immersion heater with magnetic contactor and solid state circuit board can prevent freezing during operation in cold weather. A pump heat trace comes standard with the basin heater package. Solid state water level control package monitors basin water level with solenoid-valve water makeup. Configurations include makeup along with high and low water level alarm and cutoff and electric basin heater cutoff. Positive closure dampers gives the added security of safe operation in freezing weather by trapping heat inside the fluid cooler while fans are inoperable. Electric or pneumatic actuator operation allow for flexibility during design. Vibration switch protects against mechanical failure should the tower experience high vibration levels. Automatically shuts down the motor. Manual reset ensures inspection to correct initial vibration cause. Variable speed drive provides the ultimate in temperature control, energy management, sound control and mechanical equipment longevity. Control systems range in sophistication from standard fan and pump starters to Programmable Logic Controllers that work in conjunction with your building or process system. Sound attenuation baffles can be installed across the length of the air inlet, as well as the air outlet opening. All baffles are constructed of perforated sheet metal and contained within a self-supporting steel box. Standard HDG coil pressure tested to 400psi Hot dipped galvanized after fabrication Welded process fluid connection on either side Coils sloped for drainage For fully-rated thermal performance, low sound levels and installation costs, year-round operating reliability and simplified maintenance requirements, demand the Marley MC Fluid Cooler. Call 800 462 7539 or visit www.spxcooling.com to learn more.

Frequently Asked Questions Q A Why should I purchase a fluid cooler instead of a cooling tower/heat exchanger combination? Fluid coolers reduce piping and system complexity by combining three pieces of equipment (cooling tower/ heat exchanger/pump) into one unit. This can prove beneficial in critical application areas. In addition, a cooling tower and heat exchanger usually have a combined approach temperature of about 7 F. With a closed circuit fluid cooler, approaches as low as 5 F can be guaranteed allowing for colder process fluid temperatures and greater efficiency during operation. Closed circuit systems also protect the process fluid from contamination reducing fouling and scaling tendencies within sensitive systems. Clean closed loops result in greater efficiency, reduced energy costs and reduced maintenance costs. Q A What are some common closed circuit/fluid cooler applications? Typical closed circuit applications include any process that is sensitive to fouling and corrosion. Many HVAC applications are ideal for fluid coolers. Fluid coolers are also ideal for installations where the process fluid is something other than water. The MC Fluid Cooler can effectively discharge heat from other fluids such as glycol, oil or other unusual water mixtures. Common applications for the MC Fluid Cooler: Common sites for the MC Fluid Cooler: Water source heat pumps Cooling special fluids Condominiums Self-contained cooling Compressor jacket cooling Steel mills Chillers Machine jacket cooling Power plants Free cooling Schools Hospitals Q A Q A Why would I install a forced draft fluid cooler over other fluid cooler configurations? There are a number of reasons why a forced draft fluid cooler might be the smartest choice: Low energy and water consumption forced-draft fluid coolers can alternately operate in a dry cooling mode if ambient conditions are favorable. This minimizes energy and water consumption, saving money while conserving natural resources. For situations that require greater electrical energy savings, consider the Marley MH Fluid Cooler. Low noise centrifugal fans and a fully-enclosed falling water area work to create one of the quietest fluid cooler configurations on the market. Small footprint a forced-draft, counterflow design requires considerably less plan area than crossflow towers. High static the capability of centrifugal fans makes it ideal for ducted applications, indoors or out. Can a fluid cooler be used in freezing weather applications? Yes, but care must be taken to ensure proper operation and orientation (preventing recirculation). By maintaining sufficient flow rate and heat load on the process fluid, a closed circuit tower can be utilized in almost any environment. Fluid exiting the coil must be maintained at or above 45 F. Cycling of the recirculation should not be used to control process temperatures. Instead, introduction of ethylene or propylene glycol solutions is the best means to protect the coil. For more severe fluid cooler freezing environments, we recommend the Marley MH Fluid Cooler.

TOweR TOweR models GPm* GPm L models L ww HH INSTALLed weight MCF7012 _ 081 34-44 6' - 0" 4' - 1" 9' - 3" 3110 MCF7012 _ 101 40-51 6' - 0" 4' - 1" 10' - 0" 3490 MCF7012 _ 121 44-56 6' - 0" 4' - 1" 10' - 9" 3870 MCF7013 _ 081 63-77 9' TOweR - 0" 4' models - 1" 9' - 3" 4035 MCF7013 _ 101 72-86 9' - 0" 4' - 1" 10' - 0" 4540 H MCF7013 _ 121 76-93 9' - 0" 4' - 1" 10' - 9" 5050 MCF7014 _ 081 95-115 12' - 0" 4' - 1" 9' - 3" 5070 MCF7014 _ 101 104-125 12' - 0" 4' - 1" 10' - 0" 5700 MCF7014 _ 121 109-133 12' - 0" 4' - 1" 10' - 9" 6340 L MCF7054 _ 081 216-283 11' - 8" 7' - 10" 13' - 8" 9050 MCF7054 _ 101 239-310 11' - 8" 7' - 10" 14' - 5" 10270 MCF7054 _ 121 250-323 11' - 8" 7' - 10" 15' - 2" 11300 MCF7055 _ 081 357-402 11' - 8" 7' - 10" 13' - 8" 12250 MCF7055 _ 101 397-445 11' - 8" 7' - 10" 14' - 5" 13940 MCF7055 _ 121 425-476 11' - 8" 7' - 10" 15' - 2" 15625 MCF7073 _ 081 183-215 8' - 9" 9' - 9" 13' - 8" 9070 MCF7073 _ 101 208-249 8' - 9" 9' - 9" 14' - 5" 10245 MCF7073 _ 121 222-264 8' - 9" 9' - 9" 15' - 2" 11425 MCF7074 _ 081 270-312 12' - 1" 9' - 9" 13' - 8" 11270 MCF7074 _ 101 295-343 12' - 1" 9' - 9" 14' - 5" 12770 MCF7074 _ 121 313-363 12' - 1" 9' - 9" 15' - 2" 14270 MCF7075 _ 081 419-487 17' - 7" 9' - 9" 13' - 8" 15075 MCF7075 _ 101 460-538 17' - 7" 9' - 9" 14' - 5" 17150 MCF7075 _ 121 488-565 17' - 7" 9' - 9" 15' - 2" 18995 H INSTALLed weight W * at 95º F HW, 85º F CW and 78ºF WB

AddITIonAL MC FLUId CooLER PUBLICATIonS For further information about the MC Fluid Cooler including engineering schematics, data, layout requirements and more ask your Marley sales representative for a copy of the following publications: other SPX CooLInG TECHnoLoGIES PRodUCTS SPX Cooling Technologies offers a full line of industry-leading products with unmatched support and innovation designed to help you get the most out of your cooling process. Take a look at these other SPX Cooling Technologies products. Engineering data and Specifications IoM Manual Marley MH Fluid Cooler Marley MCW Cooling Tower Recold MW Fluid Cooler Recold JW Fluid Cooler SPX COOLING TECHNOLOGIES, INC 7401 WEST 129 STREET OVERLAND PARK, KANSAS 66213 UNITED STATES 913 664 7400 In the interest of technological progress, all products are subject to design and/or material change without notice. 2011 SPX Printed in USA MCF-11