INSTALLATION INSTRUCTIONS

Similar documents
TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Operation and Installation SE-ILC. Automatic Transfer Switches. Model: Service Entrance-Rated Transfer Switch with Integrated Load Center GM39766-SA1

INSTALLATION INSTRUCTIONS

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

FA-300 Series. LED Fire Alarm Control Panel. User Guide. FA-300 SERIES Fire Alarm Control Panel. FA-300 SERIES Fire Alarm Control Panel

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

TT /97 WARNING WARNING WARNING INSTALLATION INSTRUCTIONS

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

SFC-200 SERIES LED FIRE ALARM PANEL

Premier Hazard STC Instructions

Type 8001 PRIME MOVER CONTROLS INC. ALARM ANNUNCIATOR TYPE8001 FEATURES SB 8001B

The Remote alarm Panel, TYPE RAPv2

20 Light Remote Annunciator

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-9

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

TSM/TSSM OVERVIEW 3.1

Application, Installation, Operation & Maintenance Manual

Installation, Operating and Maintenance Manual

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Intelligent Security & Fire Ltd

MR-2602 Two Zone Fire Alarm Control Panel

PowerCommand FT-10 Network LONWORKS System Annunciator

M2500 Engine Controller Installation Manual

User Operation Manual

VoCALL - CFVCC5. Compact 5 Line Exchange Unit. Installation & Commissioning Manual

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

21-light Remote Annunciator. Owner s Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

AL800ULADA. NAC Power Extender. Installation Guide

EvacU Emergency Warning Control and Indicating Equipment (Occupant Warning Systems) Technical Manual MAN3072-5

CSP-204 CSP-208 CSP-104 CSP-108

Installation Manual Premier 412/816/832. Issue 10

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

EXTINGUISHING AGENT RELEASE MODULE

Installation and user manual for the BiWire / Conventional Repeater Panel

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

SP-1000X. Panic Device Power Controller Installation Guide. Rev

M2000 Engine Controller

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

ENGINE GENERATORS AND ACCESSORIES

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

MULTIGUARD MULTIGUARD USERS MANUAL TYPE S3/240W 26/01/2010

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

Security System. User Guide for the LED Command Center

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

NO ONE DARES COME CLOSE O WNER S GUIDE 7756V

ORION Mini-Rep INSTALLATION MANUAL

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

Control/Communicator Installation Manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Power Supply / Battery Charger Units, incorporating load switching relays for Smoke Dispersal, Bell Booster or other uses

Engine Block Heater Service Kits (Tank Type) 30RZ/33RZ/45RZ (CSG 649 Ford Powered) Standby Generator Sets

EVO192 v3.0 Fire and Burglary What s New

M2000 Engine Controller

Across-the-Line SERIES MP300 Combined Manual and Automatic

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Leak Detection System Leak Minder Model: LDA-1 Instruction Manual

Kwêbeam GSM/Interface/Repeater Module

DGC-500 DIGITAL GENSET CONTROLLER

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

What you get Welcome to the best generation of security with remote start. Your system contains everything you need.

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

DIGITAL LIGHT CONTROLLER

LeakSafe. solutions. WaterSwitch2. Installation Instructions

Model 17A00 Expansion Enclosure

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

CHECKFIRE 110 DETECTION AND ACTUATION SYSTEM

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Conventional Fire Alarm System 2014 V1.2

Conventional Releasing Control Panel

What you get Welcome to the best generation of security with remote start. Your system contains everything you need.

Annunciation, Remote Monitoring, Control Industrial Control Panels

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

FIRE ALARM CONTROL PANEL FVC01-08

OPERATOR S MANUAL MR-2100/2200. Fire Alarm Control Unit. Revision 0 Document #: LT-2002

Engine Block Heater Service Kits (Tank Type) ROZJ 6076T and 6076A (John Deere Powered Standby Generator Sets)

Soft Start Series MP700 Solid State, Reduced Voltage

DGC-1000 DIGITAL GENSET CONTROLLER

WARNING FIRE DOOR CLOSING

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

ITI Caretaker Basic Commands

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

Wireless D.I.Y. Alarm Kit

SECTION AUTOMATIC TRANSFER SWITCHES

Independent Zone Control (I.Z.C.)

Installation Guide for models:

Transcription:

TT-46 8/05 INSTALLATION INSTRUCTIONS Original Issue Date: 8/05 Model: Automatic Transfer Switches equipped with MPAC 500 Controls Market: ATS Subject: External Alarm Module (EAM) Kit GM38795-KP Introduction The External Alarm Module (EAM) connects to automatic transfer switches equipped with MPAC 500 controls. Use the EAM to perform the following functions from a convenient location up to 50 meters (500 ft.) away from the transfer switch: Start the generator set and transfer the load Transfer back to utility power and signal the generator set to stop Customer-Supplied Parts Obtain the following items locally before installation: Standard 2 cubic inch outlet box with mounting screws GFCI outlet cover plate or rocker switch plate Category 5e network cable with RJ-45 (8-conductor) connectors, 50 m (500 ft.) maximum Receive visible and 85 db audible indication that the generator set is supplying the load Receive visible and 85 db audible indication of system faults The EAM is designed for indoor installation in a standard 2 cubic inch outlet box. Note: The MPAC 500 accessory board is required for EAM connection and operation. The EAM is powered through the accessory board. The EAM also contains a rechargeable battery that powers the module when no other power is available. The battery recharges when the power returns. 2 3 4 The generator set master switch must be in the AUTO position for EAM operation. The EAM is constructed of two parts, circuit board GM3749 and switch/led membrane GM38872, which are factory-assembled and ready to install into a standard outlet box. Read the entire installation procedure and obtain the required customer-supplied parts before beginning installation. Perform the steps in the order shown. Refer to ATS Operation and Installation Manual TP-6345 as needed. See Figure for an illustration of the EAM.. Fault LED 2. Alarm Silence Button 3. Generator Set Supplying Load LED 4. Test (Start/Stop) Button Figure External Alarm Module (EAM) GM38795

Safety Precautions Observe the following safety precautions while installing the kit. WARNING DANGER Hazardous voltage. Will cause severe injury or death. Disconnect all power sources before opening the enclosure. Accidental starting. Can cause severe injury or death. Disconnect the battery cables before working on the generator set. Remove the negative (--) lead first when disconnecting the battery. Reconnect the negative (--) lead last when reconnecting the battery. Disabling the generator set. Accidental starting can cause severe injury or death. Before working on the generator set or connected equipment, disable the generator set as follows: () Move the generator set master switch to the OFF position. (2) Disconnect the power to the battery charger. (3) Remove the battery cables, negative (--) lead first. Reconnect the negative (--) lead last when reconnecting the battery. Follow these precautions to prevent starting of the generator set by an automatic transfer switch, remote start/stop switch, or engine start command from a remote computer. Grounding electrical equipment. Hazardous voltage can cause severe injury or death. Electrocution is possible whenever electricity is present. Open the main circuit breakers of all power sources before servicing the equipment. Configure the installation to electrically ground the generator set, transfer switch, and related equipment and electrical circuits to comply with applicable codes and standards. Never contact electrical leads or appliances when standing in water or on wet ground because these conditions increase the risk of electrocution. 2 TT-46 8/05

Installation Procedure. Place the generator set master switch in the OFF position. 2. Disconnect the power to the battery charger, if equipped. 3. Disconnect the generator set engine starting battery(ies), negative (--) lead first. 4. Open the circuit breakers to disconnect power to the transfer switch before opening the enclosure. 5. Choose a convenient location for the EAM up to 50 m (500 ft.) from the transfer switch. Install a standard 2 cubic inch outlet box (not supplied) at the EAM location. 6. Route Category 5e straight networking cable with RJ-45 connectors (maximum length 52 m [500 ft.]; not supplied) from the ATS Accessory board to the outlet box for the EAM. See Figure 2. 7. Set DIP switch 3 on the ATS Accessory board to the ON (maintained) position. See Figure 2. 9. Mount the EAM assembly into the outlet box using the screws supplied with the box. Cover the EAM assembly with a GFCI outlet cover plate or rocker switch plate (not supplied). See Figure 3. 0. Close and secure the ATS enclosure door.. Close the circuit breakers to reconnect power to the ATS. 2. Check that the generator set master switch is in the OFF position. 3. Reconnect the generator set engine starting battery, negative (--) lead last. 4. Reconnect power to the battery charger, if equipped. 5. Move the generator set master switch to the AUTO position. 6. Check the EAM and system operation by starting and stopping a test as described in the following section. 8. Use the Category 5e cable to connect P0 on the EAM circuit board to connector P3 on the ATS Accessory board. See Figure 2 and Figure 3. 00 and 200 Amp ATS Controls 400 Amp ATS Controls 4 3 2 2 3. MPAC 500 main logic board 2. RJ-45 connector for EAM connection (P3) 3. Accessory Board 4. Accessory board DIP switches 4 GM38796 Figure 2 ATS Accessory Board TT-46 8/05 3

. RJ-45 connector (P0) ADV-7099 Figure 3 EAM Dimension Drawing, ADV-7099 4 TT-46 8/05

EAM Operation See Figure for an illustration of EAM buttons and LED indicators. Figure 4 summarizes the operation of the LED indicators and audible alarm. Note: The Test and Alarm Silence buttons must be pressed and held for at least one second to operate. This feature guards against accidental system starts and stops. Note: The Maintained/Momentary DIP switch on the ATS accessory board must be set to the ON (maintained) position for EAM operation. Pressing the Test button activates a relay on the EAM circuit board to start a test. Pressing the button again deactivates the relay and stops the test. Starting a Test To start the generator set and transfer the load, press the EAM Test (Start/Stop) button. The GEN LED flashes slowly until the generator set starts and the ATS transfers the load. The GEN LED then lights steadily and the audible alarm beeps once every 0 minutes to indicate that the emergency power system has been started by the EAM and is running. Stopping a Test Press the Test (Start/Stop) button to stop a test. The ATS transfers the load back to the utility and then stops the generator set engine. The GEN LED flashes slowly until the load is transferred. Pressing the Test button will not transfer the load or stop the generator set if utility power is not available. In this case, the fault LED will indicate a shutdown timeout fault after 2 minutes. (See Faults.) Press the Alarm Silence button to clear the fault. When the utility power returns, the ATS will then transfer the load and stop the generator set. The generator set engine may continue to run until the engine cooldown time delay expires. See the Transfer Switch Operation and Installation Manual for information about time delays. Audible Alarm The alarm sounds once every 0 minutes to indicate that a test has been started by a remote start command from the EAM. To silence the alarm, press the Alarm Silence button. The GEN LED flashes every 2 seconds if the alarm is silenced while the generator set is supplying the load. The GEN LED flashes but the alarm does not sound if the system is running due to an exercise run or an automatic start triggered by loss of the utility power. The alarm sounds 3 short beeps every minute and the Fault LED lights or flashes to indicate a fault. See Figure 4. Silencing the Alarm Press the Alarm Silence button to silence the audible alarm. If the alarm is silenced during a test, the GEN LED flashes once per second to indicate that the generator set is supplying the load and the alarm is silenced. An ATS fault will reactivate the alarm if it has been silenced. If the alarm is silenced when the GEN LED is not illuminated, there is no visible indication that the alarm is silenced. Press the Alarm Silence button again to reactivate the alrm. LED Indicator Alarm Condition GEN Steady One beep/0 minutes Generator set supplying load after a remote start signal from the EAM Test button Fast flash every second None Generator set supplying load after a remote start signal from the EAM Test button and alarm silenced None Generator set supplying load due to automatic start after utility power loss or exercise run Slow flash None System starting or stopping in response to Test (Start/Stop) button every 2 seconds Fault Steady Three short Power system (ATS) fault beeps/minute Flashing Three short beeps/minute Test did not start (or stop) within 2 minutes of EAM Test button activation Figure 4 EAM LED and Audible Alarm Operation TT-46 8/05 5

Faults The Fault LED lights and the alarm sounds 3 short beeps every minute to indicate the following faults: Failure to acquire emergency source (ATS) Failure to transfer (ATS) Auxiliary switch fault (ATS) Startup/shutdown timeout (EAM, flashing LED) The fault LED flashes to indicate startup/shutdown timeout if the transfer switch does not transfer the load within 2 minutes of the signal from the EAM. Press the Alarm Silence button to clear this fault condition. Lamp Test Press the Alarm Silence button briefly (less than second) to illuminate both LEDs. Holding the button more than one second will silence or reactivate the alarm as described in Silencing the Alarm, above. Parts List External Alarm Module Kit: GM38795-KP Qty.* Description Part Number PCB Assy, Audible Alarm GM3749 Membrane, Switch/LED GM38872 * The two parts are factory-assembled into one unit. Refer to the Transfer Switch Operation and Installation Manual for more information about transfer switch faults. 6 TT-46 8/05