HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

Similar documents
Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Accuracy by Design Products for the HVAC Professional

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Measurement and Control Technology

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

THERMASREG TR 040 THERMASREG TR 060

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

Beck. The differential pressure transmitter for air

SITRANS T temperature transmitters A broad product family for every application. sitrans

Huminator II. Precision Humidity Generator. ww.testo.in

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

Dew-Point Transmitters and Instruments

DESCRIPTION AND SPECIFICATION

Thermostats. Innovative solutions for the toughest requirements

Thermostats. Innovative solutions for the toughest requirements

Hygrostats (hygrometric)

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

Flexible and efficient: Close Climate Control for IT equipment

Key benefits. Why Condair CP3?

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

SHAKING WATER BATHS ENGLISH

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

PoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS

Thermostats. Innovative solutions to meet the most stringent standards

DMFPM-2R MULTIFUNCTIONAL

Sitron s CF Line of Flow Switch Monitors

PM100V PM80V PM15V. Ex works. Depending on the specific range of application a regular ecalibration of the sensor head (PMU-V) has to be effected.

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Frost Protection Thermostat

Turbimax CUE21 / CUE22

STEGO Products stand for perfect Thermal Management.

Distributed By: M&M Control Service, Inc Building Technologies

More Precision. indusensor Linear inductive displacement sensors

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

STEGO Products stand for perfect Thermal Management.

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Condair Mk5. Getting rid of scale. The steam humidifier with scale management. Low maintenance. Reliability. And superior control accuracy

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

I/A Series 716C 1/16 DIN Temperature Controller

3M Overhead Ionizing Blower 991A

Using the Model 1500 Portable Chilled Mirror Hygrometer

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

COMPACT FLAME CONTROLLER CFC 2000

Thermohygrometer with Single Type K Input and Superheat Function

ELECTRONIC HUMIDISTAT: H200

More Precision. indusensor // Linear inductive displacement sensors

Temperature Controllers

Air Dehumidifying Systems

Environmental simulation chamber for complex alternating climate profiles

Resistance heaters. Ventilation systems. Air-air exchangers. Air-water exchangers. Cooling units. Control devices. Calculation and selection

Dräger PIR 7200 Toxic Gas Detection Transmitter

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

HIGH CAPACITY PRODUCT LINE

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Life insurance for your electronics

PROCESS AUTOMATION PROTECTING YOUR PROCESS THE DEFINITION FOR INTRINSIC SAFETY K-SYSTEM K-SYSTEM THE MOST TRUSTED NAME.

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

HTO-45 HUMIDITY TEMPERATURE PROBE INSTRUCTION MANUAL

Products. World Edition

MSA Flame and Gas Detection. [ for the Oil, Gas and Petrochemical Industries ]

DEi COMPRESSED AIR & GAS TREATMENT. Purifying your compressed air, increasing your efficiency.

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

ELECTRONIC HUMIDISTAT: H270

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

50% Refrigeration solutions to lower energy costs and reduce environmental impact. Foodservice Solutions. Up to

MOV Series Electric Ovens Dry Heat Sterilizers MOV-112F/212F MOV-112/212 MOV-112S/212S MOV-112F MOV-212

HIGH CAPACITY PRODUCT LINE

Product data sheet AIRWIN BO-120 Hygrostats

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

Carbon Monoxide (CO) Gas Detectors with (0)2-10 Vdc or (0)4-20 ma Output

Bernstein product overview

TEC2620 Series Non-Programmable Fan Coil Network Thermostat Controller and Remote I/O Relay Packs

Commercial and Technical Data

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Atlas Copco. Heat-of-compression rotary drum dryers ND series ( l/s, cfm)

Company profile. ANKERSMID is a privileged partner of several companies like Siemens, BASF, Bayer, Umicore, Dräger and many more.

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

Multi-Gas-Controller MGC2

CDP 40 SWIMMING POOL DEHUMIDIFIER

TSEK VHR EC HEAT RECOVERY UNITS

METPOINT THE COMPLETE RANGE OF PRECISION CONTROL DEVICES FOR COMPRESSED AIR DEW POINT, FLOW, AND LEAKAGE

Instruments. for hydroponics & horticulture 2016

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

ECOLOG Data logger series we prove it.

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

Eldon Product Overview

SDR Dry Room. Outstanding performance

Heaters, Thermostats and Hygrostats

TEC3000 Series Wireless, Stand-Alone, and Field-Selectable BACnet MS/TP or N2 Networked Thermostat Controllers Catalog Page

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

Transcription:

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY > Mechanical > Electronic > Guards PRODUCT RANGE 2017 FÜHLBARE PRÄZISION

HYGRASREG MECHANICAL For use in dust-free, non-polluted and non-aggressive air HYGRASREG RH - 2 with external control dial 67,32 HYGRASREG RHT with external control dials 140,13 HYGRASREG KH -10 with external control dial 177,17 The mechanical and electronic hygrostats from S+S are designed for control and /or monitoring of relative humidity in residential, office, IT and manufacturing environments, in laboratories, indoor swimming pools and greenhouses as well as in climate and control cabinets, ventilation and air conditioning ducts, humidifying and dehumidifying systems. As a two-position microswitch or room hygrostat including temperature controller, respectively, HYGRASREG RH-2 and RHT are equipped with a humidity measuring element made of plastic fibers. In addition, the HYGRASREG RHT room controller has bi-metal temperature sensor. The HYGRASREG RH-2 room and the HYGRASREG KH-10 duct devices can also be used as minimum guards or maximum hygrostats. HYGRASREG MECHANICAL Type WG01 Setting Range Features Setting Item No. Price RH - 2 IP 30 RH-2 25...95 % r. H. 1x Change-over contact external 1202-40C0-0010-000 67,32 RH-2 U 25...95 % r. H. 1x Change-over contact internal 1202-40C0-0020-000 69,36 RHT IP 30 RHT-1 35...100 % r. H., +10...+35 C Main switch external 1202-4010-0000-000 140,13 KH - 10 IP 65 KH-10 35...100 % r. H. external 1202-3012-0010-000 177,17 KH-10 U 35...100 % r. H. Setpoint adjuster covered internal 1202-3012-0020-000 179,31

NEW HYGRASREG ELECTRONIC HYGRASREG AHT - 30 198,90 HYGRASREG AH - 40 153,00 HYGRASREG KHT - 30 198,90 HYGRASREG KH - 40 154,02 HYGRASREG RHT - 30 external setting 220,12 Our new HYGRASREG AHT- 30 / KHT- 30 / RHT- 30 electronic on-wall, duct and room hygro-thermostats provide two continuous and two switched outputs for up to four different operating modes with adjustable switching thresholds. The spacious multi-line display in Tyr 2 housing alternates between actual humidity and temperature every 3 seconds. A durable, digital humidity sensor with integrated temperature sensor ensures a measuring accuracy of ± 3 % and ± 0.2 K. All devices including the HYGRASREG AH - 40 / KH - 40 single-step hygrostats in compact Tyr 1 housing feature our innovative slotted / cross head bolting system with integrated arrest and spring geometry for spray water protection (IP65). Standard delivery includes a. Optionally, the devices can also be supplied or retrofitted with a metal sinter filter. HYGRASREG ELECTRONIC Type WG02 (WG01) Setting Range Features Output Setting Display Item No. Price AHT - 30 IP 65 AHT-30W-I TYR2 5...95 % r. H., 35...+80 C 2x Change-over contact 2x 4...20 ma internal 1202-7127-2421-000 198,90 AHT-30W-U TYR2 5...95 % r. H., 35...+80 C 2x Change-over contact 2x 0-10 V internal 1202-7127-1421-000 198,90 AH - 40 (WG01) IP 65 AH-40W TYR-1 5...95 % r. H. 1x Change-over contact internal 1202-1065-0221-000 153,00 KHT - 30 IP 65 KHT-30W-I TYR2 5...95 % r. H., 35...+80 C 2x Change-over contact 2x 4...20 ma internal 1202-8127-2421-000 198,90 KHT-30W-U TYR2 5...95 % r. H., 35...+80 C 2x Change-over contact 2x 0-10 V internal 1202-8127-1421-000 198,90 KH - 40 (WG01) IP 65 KH-40W TYR-1 5...95 % r. H. 1x Change-over contact internal 1202-3065-0221-000 154,02 RHT - 30 IP 30 RHT-30W U 5...95 % r. H., +5...+45 C 2x Change-over contact 1x 0-10 V internal 1202-4077-1021-200 153,55 RHT-30W 5...95 % r. H., +5...+45 C 2x Change-over contact 1x 0-10 V external 1202-4077-1011-200 155,80 RHT-30W DISPLAY 5...95 % r. H., +5...+45 C 2x Change-over contact 1x 0-10 V external 1202-4077-1211-200 220,12

HYGRASREG & HYGRASGARD GUARDS NEW For use in dust-free, non-polluted and non-aggressive air HYGRASREG LS - 2 with 2 electrodes and clear-cover (IP65) 102,11 HYGRASREG LS - 4 with 4 electrodes and clear-cover (IP65) 120,36 HYGRASREG KW - SD with strap and snap-on lid (IP43) 89,07 HYGRASREG KW - W with strap, display and transparent cover (IP65) 95,24 HYGRASREG TW - W with strap, display and transparent cover (IP65) 149,13 HYGRASGARD TW - Modbus - extern with Y-adapter standard (IP65) 170,65 HYGRASREG KW condensation and HYGRASREG TW dew point guards are mounted on chilled ceilings, chilled / cold water pipes or cooled surfaces. A durable, digital humidity sensor with integrated temperature sensor detects condensation or dew formation by means of pro-dynamic cross-convection (no conductivity measuring, S+S patent). HYGRASREG LS leakage or water ingress detectors are available with 2 or (upright connecting) 4 electrodes. The clear-cover housing versions provide a visual control of the LED indicators inside the guard. The new HYGRASGARD TW - Modbus device is designed for use in an overall monitoring and control system and features our galvanic isolation of bus cable and housing by means of its patented Y adapter. HYGRASREG & HYGRASGARD GUARDS Type WG01 Measuring Range Features Sensor Display Item No. Price KW - SD IP 43 (snap-on lid) KW-W-SD ca. 93 % r. H. Change-over contact internal 1202-1075-0001-020 89,07 KW-W-SD EXTERN ca. 93 % r. H. Change-over contact external 1202-1075-0001-040 97,52 KW IP 65 (transparent cover) KW-W ca. 93 % r. H. Change-over contact internal 1202-1025-0001-020 95,24 KW-W EXTERN ca. 93 % r. H. Change-over contact external 1202-1025-0001-040 115,68 TW IP 65 (transparent cover) TW-W 75...100 % r. H. Change-over contact internal 1202-1015-0001-000 107,10 TW-W DISPLAY 75...100 % r. H. Change-over contact internal 1202-1015-1201-020 149,13 TW-U 0...100 % r. H. 0-10 V internal 1201-1011-1001-020 111,18 TW-U/W 0...100 % r. H. 0-10 V + Change-over contact internal 1202-1012-1001-020 127,50 TW-U/W DISPLAY 0...100 % r. H. 0-10 V + Change-over contact internal 1202-1012-1201-020 169,53 TW-W EXTERN 75...100 % r. H. Change-over contact external 1202-1015-0021-030 137,70 TW-W EXTERN DISPLAY 0...100 % r. H. 0-10 V + Change-over contact external 1202-1015-0221-030 179,72 TW - Modbus IP 65 (standard) TW-MODBUS 0...100 % r. H., 35...+80 C RS485 internal 1201-1211-3001-020 155,96 TW-MODBUS DISPLAY 0...100 % r. H., 35...+80 C RS485 internal 1201-1211-3201-020 198,90 TW-MODBUS EXTERN 0...100 % r. H., 35...+80 C RS485 external 1201-1211-3001-030 170,65 TW-MODBUS EXTERN DISPLAY 0...100 % r. H., 35...+80 C RS485 external 1201-1211-3201-030 201,96 LS IP 65 (transparent cover) LS-2 (2 electrodes) Conductance > switching threshold Change-over contact internal 1202-1042-0000-000 102,11 LS-4 (4 electrodes) Conductance > switching threshold Change-over contact internal 1202-1042-0000-100 120,36

OPTIMUM ACCESS TO ALL ELECTRONICS 2 Quality Assurance Calibration and balancing are done by means of the bus system in climate cabinets 3 Offset Potentiometer For fine adjustment (zero point offset) and readjustment upon recalibration 1 4 DIP Switches For multi-range toggling as well as setting of measuring ranges, response times, damping times, units and configuration levels 5 Screw Terminals Active output signals 0-10 V, 4...20 ma or switched output Extra-Large Display (70 x 40 mm) With backlighting as well as display of range violation, sensor breakage, sensor short circuit and physical units 6 Digital Humity & Temperature Probe Highly precise, longterm stable and temperature compensated

> 55 employees > 500 m 2 of office administration space > 4000 m 2 of manufacturing space > 800 m 2 finished parts warehouse > In-house tooling and test equipment design > 24-hours shipment service > Made-to-order production A PASSION FOR INNOVATION S+S Regeltechnik defines itself as a flexible and innovative partner for your requirements, from the single device to networked facility automation. To us, innovation means to lead the market both in technology and in quality. This is how we back up your investment in products that express our passion for reliability and precision. BROAD PORTFOLIO Our sensors, thermostats, transducers, hygrostats, guards, detectors and room climate controllers for facility engineering are designed to be multifunctional. This reduces the diversity of types and expands their application potential. Thanks to microprocessor technology, almost any measuring range can be represented, including custom specifications. SUPERIOR QUALITY & CERTIFIED SAFETY All devices are function tested as well as calibrated in-house prior to shipment and meet strict safety, quality and sustainability standards. S+S REGELTECHNIK GMBH PIRNAER STRASSE 20 90411 NUREMBERG GERMANY PHONE +49 (0) 911 519 47-0 FAX +49 (0) 911 519 47-70 FAX +49 (0) 911 519 47-73 mail@spluss.de www.spluss.de Our development and production in Nuremberg, Germany, is certified by the Technical Inspection Authority (TÜV) in Thuringia to DIN EN ISO 9001:2008. DIN tested and certified RoHS tested and certified ESD compliant manufacturing EAC certified GOST certificates for export of all S+S products to CIS member states CE compliant devices tested by external laboratories For fast & direct ordering, visit www.spluss.de