GAS DETECTION & RESPIRATORY PROTECTION C A T A L O G U E P A R T I : G A S D E T E C T I O N 1
Protégé ZM - O2 A 2-years lifetime ATEX single gas detector H2S - CO - O2 The Protégé ZM Single Gas Monitor is an easy-to-use, zeromaintenance gas detection solution that delivers high performance in a small, ergonomically designed package. It is available in oxygen (O2), carbon monoxide (CO) and hydrogen sulfide (H2S) single gas models. Two years of service, hassle free : The Protégé ZM is simple to use. Just turn it on for the first time, and the monitor does the rest. Using the default settings from the factory there is no need to set up or program the monitor. Once activated, the Protégé ZM monitor does not require charging or calibration so these monitors can be deployed in the field 24 hours a day, every day for two years, maintenance and hassle free. The H2S and CO models include a hibernate feature which allows you to extend your battery life up to one additional year. 3 versions available: 2025937: Protégé ZM Single Gas H2S Monitor (1-100 ppm) 2025938: Protégé ZM Single Gas CO Monitor (1-300 ppm) 2025939 : Protégé ZM Single Gas O2 Monitor (1-30%/vol.) Alarms: Visual: Red LED Audible: 95db - Vibrating: yes Size: 3.7" H x 2.2" W x 1.3" D Weight: 2.7 oz 76.5g Power Source: Lithium Ion battery Battery Life Indication: Yes Certifications: EMC Compliance CE Marked; EMC\EMI\RFI Compliant Explosive Atmospheres ETL/cETL certification to UL 913 7th, CSA C22.2 No. 157 for use in Class I Division 1 & 2, Groups A, B, C and D hazardous areas; IECEx Ex ia IIC T4 Ga; ATEX Directive (94/9/EC) ATEX II 1 G Ex ia IIC T4 Ga Approvals CE Mark includes both ATEX & EMC testing 2
T40 ATEX single gas detector (CO or H2S) The T40 is an ATEX single gas monitor designed to protect personnel from dangerous hydrogen sulfide or carbon monoxide gas exposure. The T40 includes a large, liquid crystal display (LCD), adjustable alarm setpoints and a 2-years warranty Sensors: CO H2S Electrochemical Measuring Ranges: Carbon Monoxide 0-999 ppm in 1 ppm increments Hydrogen Sulfide 0-500 ppm in 1 ppm increments Alarms: adjustable low and high alarm setpoint shows the highest reading during a shift internal vibrating alarm, audible/visual alarms Battery: 1 replaceable AA alcaline battery run time: approx. 1500 hours typical Case: high visibility, impact-resistant composite radio frequency interference (RFI) protection Dimensions: 86 mm x 58 mm x 19 mm (3.375" x 2.3" x.75") Weight: 98 g ( 3.5 oz.) Certifications: UL and cul: Class I, Groups A, B, C, D, T4 CSA: Ex ia IIC T4 ATEX: EEx ia IIC T4; Equipment Group and Category II 2G IECEx: Ex ia IIC T4 ANZEx: Ex ia IIC T4 Including : All Rattler T40 Monitors include: Battery (installed), additional battery, maintenance tool and instruction manual. 3
Tango TX1 Single gas monitor using two sensors to detect the same gas. The safest single gas monitor in the world. By wearing the TangoTX1 with the DualSense Technology, workers will be the safest single gas monitor users in the world. The Tango incorporates revolutionary patent pending DualSense Technology which includes two of the same type sensor for the detection of a single gas. The two sensor readings are through a proprietary algorithm and displayed as a single reading to the user. DualSense Technology was developed to address the major challenge of making sure workers are always using fully functioning, reliable instruments in the field. Until Tango, that required a bump test of the instrument before each day s use. DualSense Technology ensures that regardless of your current bump test policy, you will be significantly safer with the Tango than with any other single gas instrument on the market today. For higher-noise environments, the Tango s alarm volume, typically 100dB at 10 cm, can be increased nearly 10dB with the addition of the optional patent pending AlarmAmp. The Tango s alarm is louder than that of any other single gas instrument on the market. Alarms: Three strobe-emitting visual alarm LEDs (two red; one blue);100 decibel (db) audible alarm at a distance of 10 cm (3.94"); Vibration alarm Dimensions: 99 x 51 x 35 mm (3.9" x 2.0" x 1.4") Temperature range: -40 C to +50 C (-40 F to +122 F) Humidity Range: 15%-95% Non-condensing (continuous) Ingress Protection: IP66 ; IP67 Sensors: CO, H2S, NO2, SO2 - Electrochemical sensor technology Sensor Measuring Ranges: Carbon Monoxide (CO): 0.0 to 1,000 ppm in 1 ppm increments Hydrogen Sulfide (H2S): 0.0 to 200.0 ppm in 0.1 ppm increments Nitrogen Dioxide (NO2): 0.0 to 150.0 ppm in 0.1 ppm increments Sulfur Dioxide (SO2): 0.0 to 150.0 ppm in 0.1 ppm increments Instrument Configuration : TX1-1 TX1-2 TX1-4 TX1-5 Tango TX1, CO Tango TX1, H2S Tango TX1, NO2 Tango TX1, SO2 4
GasBadge PRO Portable ATEX mono-gas detector, «DS2 compatible» CL2 CLO2 CO H2 H2S HCN HN3 NO2 O2 PH3 SO2 Built to Industrial Scientific s highest quality and reliability standards, GasBadge Pro provides a lifetime of gas hazard protection with more features than any other single gas monitor available. Interchangeable "smart" sensors enable the GasBadge Pro to be quickly adapted to monitor unsafe levels of oxygen or any one of the toxic gases. GasBadge Pro communicates directly via an infrared interface to optional accessories like the Docking Station, Datalink and infrared printer to further simplify and automate calibration, function (bump) testing and data downloading. Standard STEL and TWA readings, and datalogging of up to one year of survey data are featured along with an event-logger that records the past 15 alarm events. Housed in a rugged enclosure, the GasBadge Pro is immune to RF, water resistant and extremely durable. A protective concussionproof overmold protects the unit from extreme abuse in a variety of harsh industrial environments. Its simple and intuitive four-button navigation allows easy access to setup, operation and calibration functions. Interchangeable «smart» sensors: CL2 CLO2 CO H2 H2S HCN HN3 NO2 O2 PH3 SO2 Display: Custom LCD with graphical icons for easy use. Segmented display for direct gas readings.backlight for low light conditions Alarms: User selectable low and high alarms Ultra-bright LEDs, loud audible alarm (95 db) and vibrating alarm Battery: User replaceable 3V, CR2 Lithium battery Runtime: 2,600 hour run time typical Case: Rugged, water-resistant polycarbonate shell with protective concussion proof overmold. RFI resistant Dimensions: 9.4 cm x 5.08 mm x 2.79 mm (3.7" x 2" x 1.1") Weight: 85 g (3 oz.) Certifications: UL/cUL: Class I, Groups A,B,C,D T4; Class II, Groups E,F,G; Class I, Zone 0, AEx ia IIC T4 CSA: Class I, Groups A B C D T4; Ex ia IIC T4 ATEX: Ex ia I/Ex ia IIC T4; Equipment Group and Category: I M1/II 1G IECEx: Ex ia I/IIC T4 ANZEx: Ex ia I/IIC T4 INMETRO: Ex ia I Ma; Ex ia IIC T4 Ga China EX: Ex ia I/IIC T4 KOSHA: Ex ia I/IIC T4 Ingress Protection: IP67 5
MX4-Explo ATEX monitor to detect combustible gases (natural gas, butane, propane,hydrocarbons, solvents, alcohols) MX4-EXPLO to detect combustible gases (natural gas, butane, propane,hydrocarbons, solvents, alcools) Single sensor version with the opportunity to add until 3 other sensors (02, CO and/or H2S) Gain increased instrument visibility with a safety orange overmold Draw samples from up to 100 feet with an optional, integrated sampling pump Realize true portability with multi-gas protection in single-gas size Ultra- bright LEDs, loud audible alarm (95 db) at and vibrating Alarm Measuring Ranges: Combustible Gases: 0-100% LEL in 1% increments Methane (CH4): 0-5% of vol. in 0.01% increments Extra sensors: Oxygen - Carbon monoxide - Hydrogen sulfide Alarms: Ultra-bright LEDs, loud audible alarm (95 db at 30 cm), and vibrating alarm Ingress protection: IP66 IP67 Certifications: UL: Class I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4 Class II, Groups F G (Carbonaceous & Grain dust) ; ATEX: Ex ia IIC T4 Ga and Ex ia I Ma; Equipment Group and Category II 1G and I M1; IP66; IP67 IECEx: Ex ia IIC T4 Ga; IP66; IP67 CSA: Class I, Division 1, Groups A B C D, T4; Ex d ia IIC T4 C22.2 No. 152 for %LEL reading only ANZEx: Ex ia s Zone 0 I/IIC T4; IP66; IP67 InMetro: Ex ia IIC T4 Ga; IP66; IP67 KOSHA: Ex d ia IIC T4 MSHA: 30 CFR Part 22; Permissible for underground mines; Li-ion versions only PA-DEP: Permissible for PA Bituminous Underground Mines China Ex: Ex ia d IIC T4 Gb China CMC:Metrology approval China MA: Approved for underground mines; diffusion (without pump) standard Alkaline version only GOST- K: PBExdiaI X / 1ExdiaIICT4 X GOST-R: PBExdiaI X / 1ExdiaIICT4 X MX4-EXPLO diffusion version MX4-EXPLO aspirated version 6
Ventis MX4 Detect 1 to 4 gases with a large choice of cells Combustible gases (0-100% LEL) O2 CO H2S NO2 SO2 Configured for your safety, the Ventis MX4 multi-gas detector takes your gas detection program to the next level. Detect from one to four gases with a wide range of sensor options Gain increased instrument visibility with a safety orange overmold Draw samples from up to 100 feet with an optional, integrated sampling pump. The highly configurable Ventis is specifically designed to meet unique gas detection needs while maintaining worker safety. Available with or without an optional, integral pump, the Ventis is ideal for confined space or personal monitoring. Realize true portability with multi-gas protection in single-gas size An extended range lithium-ion battery pack provides up to 20 hours of continuous monitoring when using the diffusion version Ultra-bright LEDs, loud audible alarm (95 db) at and vibrating Alarm Sensors: Combustible gases/methane - Catalytic diffusion O2, CO, H2S, NO2, SO2 Electrochemical MeasurIng ranges: Combustible gases: 0-100% LEL in 1% increments Methane (CH4): 0-5% of vol. In 0.01% increments Oxygen (O2): 0-30% of vol. In 0.1% increments Carbon monoxide (CO): 0-1,000 ppm in 1 ppm increments Hydrogen sulfide (H2S): 0-500 ppm in 0.1 ppm increments Nitrogen dioxide (NO2): 0-150 ppm in 0.1 ppm increments Sulfur dioxide (SO2): 0-150 ppm in 0.1 ppm increments Case material: Polycarbonate with protective rubber overmold Alarms: Ultra-bright LEDs, loud audible alarm (95 db at 30 cm) and vibrating alarm Power source/run time: Rechargeable lithium-ion battery pack (12 hours typical @ 20 C) Ventis Rechargeable extended-range lithium-ion battery pack - 20 hours typical @ 20 C) Ventis Dimensions: 103 mm x 58 mm x 30 mm (4.1" X 2.3" X 1.2") - Ventis, lithium-ion battery version Weight: 182 g (6.4 oz) - Ventis, lithium-ion battery version Operating temperature and humidity range: -20 C- 50 C (-4 F-122 F), 15%-95% Non-condensing (continuous) Ingress Protection: IP66 - IP67 Certifications: UL: Class I, Division 1, Groups A B C D, T4; Zone 0, AEx ia IIC T4 Class II, Groups F G (Carbonaceous & Grain dust); IP66; IP67 ATEX: Ex ia IIC T4 Ga and Ex ia I Ma; Equipment Group and Category II 1G and I M1; IP66; IP67 IECEx: Ex ia IIC T4 Ga; IP66; IP67 CSA: Class I, Division 1, Groups A B C D, T4; Ex d ia IIC T4 C22.2 No. 152 for %LEL reading only ANZEx: Ex ia s Zone 0 I/IIC T4; IP66; IP67 InMetro: Ex ia IIC T4 Ga; IP66; IP67 KOSHA: Ex d ia IIC T4 MSHA: 30 CFR Part 22; Permissible for underground mines; Li-ion versions only PA-DEP: Permissible for PA Bituminous Underground Mines GOST- K: PBExdiaI X / 1ExdiaIICT4 X GOST-R: PBExdiaI X / 1ExdiaIICT4 X 7
MX6-COV Volatile Organic Compounds: Photo Ionization Detector (PID) 0-2000 ppm in 0,1 ppm increments The MX6 is more than an intelligent hybrid of the best monitoring technologies. It s the first gas monitor to feature a full-color LCD display screen. The display improves safety with clear readings in low-light, bright-light or anywhere in between. Whether the work is outside, inside or underground, it s easy to see what gas hazards lurk in the immediate work environment. And a color display is more than eye-catching. It allows the user to step through instrument settings and functions with an intuitive menu and the instrument s five-way navigation button. VOCs (Volatile Organic Compounds) gas detector Photo Ionizazion Detector (PID) with the opportunity to add more sensors (up to 5) Display/Readout: STN Color Graphic LCD Case: Lexan/ABS/Stainless Steel w/protective rubber overmold Dimensions: 13.5 cm x 7.7 cm x 4.3 cm (5.3" x 3.05" x 1.7") diffusion version Power Source (Run times): Rechargeable Lithium-ion (Li-ion) Battery Pack (24 hours typical) Rechargeable, Extended-Range Lithium-ion (Li-ion) Battery Pack (36 hours typical) Replaceable AA Alkaline Battery Pack (10.5 hours typical) Certifications: UL: Class I, Groups A,B,C,D T4; Class II, Groups F,G; AEx ia d IIC T4 CSA: Class I, Groups A,B,C,D T4; Ex d ia IIC T4 MSHA: CFR30, Part 22, Intrinsically safe for methane/air mixtures ATEX: Ex ia IIC T4 Ga / Ex ia I Ma; IP65 (IP64 pump version); Equipment Group and Category: II 1G / I M1 (I M2 w/ir sensor) IECEx: Ex ia IIC T4 Ga / Ex ia I (Ex ia d I w/ir sensor) ANZEx: Ex ia s Zone 0 I, IP64 Asp., IP65 Dif. Ex ia s Zone 0 IIC T4 INMETRO: Ex ia IIC T4 Ga GOST-R: PBExiadI X / 1ExiadIICT4 X KOSHA: Ex d ia IIC T4 China Ex: Ex ia d I/IIC T4 China CPC: Metrology Approval The MX6 clearly shows real-time readings in PPM or % by volume. An intuitive menu provides easy access to features and setup. It even supports the option of on-board graphing for easily interpreted direct readings and recorded data. 8
MX6 ATEX multi-gas detector (Up to 6 gases monitored simultaneously). Oxygen, toxic and combustible gas, and volatile organic compounds (VOCs) The MX6 is more than an intelligent hybrid of the best monitoring technologies. It s the first gas monitor to feature a full-color LCD display screen. The display improves safety with clear readings in low-light, bright-light or anywhere in between. Whether the work is outside, inside or underground, it s easy to see what gas hazards lurk in the immediate work environment. And a color display is more than eye-catching. It allows the user to step through instrument settings and functions with an intuitive menu and the instrument s five-way navigation button. List of monitored gases: Combustible gases, CL2, CLO2, CO, CO2, H2, H2S, HCL, HCN, NO, NO2, NH 3, O2, PH3, SO2 and volatile organic compounds (VOCs) Sensors: Combustible Gas/Methane: Catalytic Diffusion/Infrared CO2: Infrared Oxygen and Toxic Gases: Electrochemical VOCs: 10.6 ev PhotoIonization Display/Readout: STN Color Graphic LCD Case: Lexan/ABS/Stainless Steel w/protective rubber overmold Dimensions: 13.5 cm x 7.7 cm x 4.3 cm (5.3" x 3.05" x 1.7") diffusion version Power Source (Run times): Rechargeable Lithium-ion (Li-ion) Battery Pack (24 hours typical) Rechargeable, Extended-Range Lithium-ion (Li-ion) Battery Pack (36 hours typical) Replaceable AA Alkaline Battery Pack (10.5 hours typical) Certifications : UL: Class I, Groups A,B,C,D T4; Class II, Groups F,G; AEx ia diic T4 CSA: Class I, Groups A,B,C,D T4; Ex d ia IIC T4 MSHA: CFR30, Part 22, Intrinsically safe for methane/air mixtures ATEX: Ex ia IIC T4 Ga / Ex ia I Ma; IP65 (IP64 pump version); Equipment Group and Category: II 1G / I M1 (I M2 w/ir sensor) IECEx: Ex ia IIC T4 Ga / Ex ia I (Ex ia d I w/ir sensor) ANZEx: Ex ia s Zone 0 I, IP64 Asp., IP65 Dif. Ex ia s Zone 0 IIC T4 INMETRO: Ex ia IIC T4 Ga GOST-R: PBExiadI X / 1ExiadIICT4 X KOSHA: Ex d ia IIC T4 China Ex: Ex ia d I/IIC T4 China CPC: Metrology Approval The MX6 clearly shows real-time readings in PPM or % by volume. An intuitive menu provides easy access to features and setup. It even supports the option of on-board graphing for easily interpreted direct readings and recorded data. 9
BM25 ATEX transportable area monitor Power Source : Power source: NiMH battery pack. An intrinsically safe trickle charger is also available for longterm area monitoring in classified zones. Chargers: Integrated and intelligent charger, with continuous power supply of 12V DC to 30V DC compatible for vehicle use. A 100V AC/230V AC adaptor allows sector recharge Recharge Time: 4.5 hours Run Time: Example for combustible gases/o2/tox1/tox2: 100 hours typical Sensors: Intelligent, precalibrated, interchangeable units. Automatic regognition by the BM25A by Means of EEPROM List of gases: Combustible gases AsH3 CL2 CO CO2 COCL2 ETO F2 H2 H2S HCL HCN HF NO NO2 NH3 O2 O3 PH3 SiH4 SO2 and VOCs (volatile organic compounds) Display: Graphic liquid crystal display with backlight Alarm thresholds: LEL: 2 adjustable instantaneous thresholds in 0-60% LEL range Oxygen: two adjustable instantaneous thresholds over the sensor s whole measuring scale (over-oxygenation and underoxygenation) or two optional under-oxygenation thresholds Toxic (by sensor): two adjustable instantaneous thresholds over the whole range STEL and TWA Visual indications: An indicator light (made of 20 ultra-bright LEDs) installed on top of the instrument indicates alarm conditions and can be seen from all directions Programmable inputs/outputs: 2 relay outputs (default and gas) and 2 logic inputs (remote aknowledged and alarm transfer) Audible alarms: 103dB @ 1m Ingress Protection: IP66 Weight: 6.8 kg (15 lbs) Dimensions: 470x180 x190mm (16.7"x 7.1" x 7.5") Certifications : ATEX & IECEx VERSIONS (BM 25 and BM 25W) BM25 (standard version) Without IR sensor: With IR sensor: II 1G / I M1 II 2G / I M2 Ex ia IIC T4 Ga / Ex ia I Ma Ex ia d IIC T4 Gb / Ex ia d I Mb Class I, Division 1, Groups A,B,C,D ; Ex ia d IIC T4 Class I, Division 1, Groups C,D ; Ex ia d IIB T4 - PENDING C22.2 No.152 (% LEL only) BM25W (wireless version) Without IR sensor: With IR sensor: II 2G / I M2 II 1G / I M1 II 2G / I M2 Ex ia IIB T4 Ga / Ex ia I Ma Ex ia d IIC T4 Gb / Ex ia d I Mb or II 2G / I M2 Ex ia IIC T4 Gb / Ex ia I Mb 10
RD99 Refrigerant gas leak detector The new refrigerant leak detector is a low cost effective way of detecting the smallest of refrigerant gases. The handheld unit detects environmentally damaging gases, including the latest CFC gases. The unit has a two position sensitivity switch allowing the user to locate the smallest leaks. The RD99 has a dual alarm system for leak finding. The increased tic rate sounds and a series of visual indicators illuminate as you approach the source of the leak. This visual indication makes the detection of leaks possible in noisy environments. The RD99 is battery powered and is ideal for use with domestic and commercial refrigeration systems, automotive and airconditioning systems. Detects all existing refrigerants which include HFC s, HFC s, CFC s, SF6, R134A and R123 High Sensitivity switch to locate the smallest of leaks Easy to use one handed operation Long gooseneck probe for hard to reach areas Audio and visual leak indicator Protective rubber sleeve houses gooseneck when not in use. Sensor: 5 gms per year 134A based on LS-20 leak standard Response Time: <1 second. Advanced ionisation detection Monitored gases: CFCs - R11, R12, R13 etc HCFCs - R22, R502, R500 etc HFCs - R134A, R123, R125, R33 etc R404, R407 C, R410a Operation: Turn the instrument ON by sliding the High/Low/OFF switch to either LOW or HIGH in a non-contaminated environment i.e. Fresh air As concentration of gas increases the LED array will progressively move from flashing yellow, orange and red (highest). The power light will be illuminated green when the unit is turned on. If the batteries are too low to operate the instrument this light will be RED. Power Supply: One 9V PP3 battery Battery Life: Approx 8 hours Probe Length: 400mm Dimensions: 180mmH x 70mmW x 35mmD Weight: 400gms Duty Cycle: Continuous Ambient Conditions: 0-40 C, 0-80% RH (non-condensing) 11
C1100 Infrared portable CO2 monitor Naturally present in low quantities in the atmosphere, Carbon Dioxide remains a genuine potential risk for the confined, industrial and tertiary environments. People are particularly confronted with it in sewers, tunnels,slaughter house, food-processing industries, greenhouses, wine-making or maturing cellars etc Light, ergonomic, high performance and with a long life battery, the C 1100 pocket gas detectors allows people to work freely and move about without any risk. A high technology The C1100 is equipped of an infra-red cell which provides reliable, accurate and stable CO2 measurement. Optimised size and weight : Small & compact User friendly display Large LCD display Simultaneous and continuous display of two CO2 measurements: - current concentration - 8h TWA value average Battery & sensor status indication Adapted features A single push-button to activate and access main menu 12h battery life Controlled environment Simultaneous display of the current concentration and the TWA value Recording of the data Data transfer to a PC for working with the sample and to calibrate the detector Safety alarm 80 db audible alarm Visual alarm on a 5 step LED bar graph (green, yellow and red) displaying the hazard level Function: CO2 detector Measurement Range: 0-3 % vol. - 3-10 % vol. Type of cell: Infra-red Response Time: 15 sec (at 0.2 litre/min) Accuracy: ± 3 % of reading or ± 0.02 % vol Display: Numerical LCD Simultaneous display of CO2 measurement: current concentration in % vol. 8 h TWA value in % vol. Battery status indication, sensor status indication Alarms: Audible: 80 db buzzer Visual: 5 step bar graph LEDs (green-yellow-red) each step in the lighting up of LEDs indicates the hazard level Power supply: Li-ion accumulator (3.6 VDC / 1350 mah) Battery life: 12 hours Service life: 15 years Dimensions: 125 x 52 x 32 mm Digital interface: USB cable, UART-RS232 UIP-P software: Transfer & save data, Configuration of alarms and LED, User preferences, Sensor calibration 12