Foot control. No instrument selected. A Raise chair Chair to working position 1 B Incline backrest Chair to spitting. positioning

Similar documents
FOR YOU AND YOUR CUSTOMER

Fimet F1 User Guide Version

Dental Unit User's Guide

Dynamics Precision Speed

Illuminated Stopper Station Push Button

Flexibility and individual design turn your dental unit into an active partner. Quality is not a consideration quality is the solution

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Installation Instructions

Unlimited Mobility. The Mobile Dental Units From. B-Productions

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

FONA DURION Dental unit operation instruction

Planmeca Sovereign Classic

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTION In-Ground Color Changing

OPERATING INSTRUCTIONS

INSTALLATION INSTRUCTION In-Ground

OPERATING INSTRUCTIONS

DEKO 25 washer-disinfector

Short instructions for use ESTETICA E30

XO FLEX User Manual 2

Certificate of Compliance

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

CHIRANA Medical, a. s.

SEL-3422 Motor Relay HMI Quick-Start Guide

Lumination TM Volumetric Retrofit Kit

Unlimited Mobility The Mobile Dental Units By. BPR Swiss

SERRES SUCTION BAG SYSTEM MANUAL

DEKO 190 Ward washer-disinfector

Siemens Automation Products Siemens AG All rights reserved A5E AB, 08/2017 1

Short instructions for use ESTETICA E30

UNI 321. User s Guide

INSTRUCTION / INSTALLATION / TECHNICAL MANUAL

VisionAire V. Oxygen Concentrator Patient Manual

LOGIC CONTROLLED DEKO 25 EASE OF USE

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation & Operation Manual. AromaFlo. mr.steam. Feel Good Inc.

LS Condensate Removal Pump Installation, Operation and Service Instructions

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

Z-1500II and Z-3000II USER MANUAL Z-1500II und Z-3000II BEDIENUNGSANLEITUNG Mode D Emploi des Z-1500II et Z-3000II Machines à Fumée

Ice Maker. Use and Care Instructions. with water dispenser. Durable, high-quality stainless steel finish

GARAGE DOOR OPENER KIT

Vault Accessories Deluxe Kit

Narrow Depth Reach-in Refrigerator And Freezer Refrigerator model: 178A19RHC, 178A23RHC, 178A49RHC Freezer model: 178A19FHC, 178A23FHC, 178A49FHC

Wireless Outdoor Air Reset Adaptor PN:

200i User s information manual

Technical data. Bathroom/shower room installations. Water services (WRAS approved)

GBX GAS BOILERS USER S INFORMATION MANUAL

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Wi-Fi DOOR/WINDOW SENSOR

Operating Manual for Profident / Profident PLUS

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

Stopper II Heated Enclosure

Instructions for use KaVo Primus 1058 S/TM/C/G. Always be on the safe side.

DEKO 260 Washer - Disinfector - Dryer

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

VisionAire. Oxygen Concentrator Patient Manual

KSBC1B0 W C_ENv01.indd 1 9/14/16 11:49 AM

VIVA ace Quick Operation Guide

Voyager 125 E F S. Please read these instructions before use. Lire ces instructions avant utilisation. Lea estas instrucciones antes del usarlo.

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

VIDEO CONTROLS LIMITED

INSTALLATION INSTRUCTIONS

Care instructions ESTETICA E80. Always be on the safe side.

User s Manual for FT SERIES THE

Use and Care Guide. Over the Patient Units and Swing Mount Units

OZONE DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL MODEL:

Dyna-Form Air. Alternating Pressure Relief Overlay System

RELIABILITY AND TECHNOLOGY, SUITABLE FOR EVERY STYLE. MIGLIONICO.NET

Installation & Operating Guide

Washer disinfectors. MLC Series. for transfer trolleys, sterile containers and bulky items

(The chances are you re never going to read me) Owner s Manual.

IXIUM. DVR Smoke Alarm. User Manual

Mascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH

CAUTION CAUTION WARNING. Vulcan RT Heater With Remote Temperature Controller

CER-1 & CER-2 Installation & Testing Instructions

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

Warmup DS-2C RAIN/SNOW SENSOR CONTROLLER INSTALLATION MANUAL AUTOMATED SYSTEMS ENGINEERING ENCLOSURE TYPE 3R

HFG 12 and 24 Hydrogen Generators Installation Instructions

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

FIMET F1 DENTAL EQUIPMENT

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

SuperCELL Model SC500-H-SM User s Information

Read this owner's manual thoroughly before operating the appliance and retain it for future reference. TYPE : PORTABLE AIR CONDITIONER

InstructIons for use A-dec 561 Cuspidor

Register your product ONLINE today

DH 100 P. Always Dry dehumidifier. with. Condensation Removal System

Kit Instructions COMMON VENT KIT (PVC AND DURAVENT)

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

Atomic Digital Office Clock

Zone controller System ZC207DK INSTALLATION INSTRUCTIONS

Installation Instructions

L900 series USER MANUAL

APCTMDT. Specs 1. Basic Description 1. Installation 2. Factory Settings 2. Overview 3. Button functions 4-5. How to customize settings 6-9

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

D14 & D18 Upright Vacuum

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Transcription:

Quick guide

Foot No instrument selected Key Press briefly Preset ing A Raise chair Chair to working 1 B Incline backrest Chair to spitting C Lower chair Chair to entry and exit D Decline backrest Chair to working 2 e Switch operating light on/off F Open door lock g Activate preset Return chair to ing previous H I Instrument selected Key Key Micro motor Turbine Scaler Curing Syringe Camera press type light E Brief Select rotation scale F Brief Toggle water / Toggle water / air / both / off air / both / off G Long Chip blow Chip blow Freeze continuous continuous image H Long Run Run Run I Long Run Run Run 3 40000 4 13:57 01.05.2011 100 0s Idle state The power is switched on, but the system is not currently doing anything. Scaler power The ACT text illustrates when scaler is in use. Micro motor speed The micro motor is in use. Curing light The curing light is selected.

Instrument bridge and suction head user interface Instrument bridge user interface Key Symbol Press briefly Function Press and hold Pre-set ing Timer/Menu Doorbell Start timer, duration 30 s or other preset time Open door, preset duration Activate menu Open door, continuous Bowl rinse Rinse bowl for preset duration D A C B Cup fill Rotation Fill cup for preset duration Change rotation scale Fill cup continuously Reverse rotation Instrument water Toggle instrument water on/off All instrument flushing Instrument air Toggle instrument air on/off Suction head user interface Operation light External device Switch on or off operation light Depends on configuration Chair up Raise chair Raise chair Chair to working 1 Backrest up Incline backrest Incline backrest Chair to spitting Chair down Lower chair Lower chair Chair to entry and exit D A B Backrest down Decline backrest Decline backrest Chair to working 2 C Preset Activate preset ing Saving s Return chair to previous

Saving your own settings Saving the s for chair Position the chair to the desired. Press and hold the -button to start saving. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel. Selecting the memory slot Pre-set button 3 Utilisation 3.1 Allumer et couper le dispositif! Using pre-set s Press the -button to recall the pre-set s. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel to recall the. -button returns the chair to previous. The factory settings, which can be altered: Chair to working 1 (the backrest up, working while sitting) Chair to spitting Chair to entry and exit Chair to working 2 (the backrest up, working while standing) Select the user Press and hold the -key on the instrument bridge. This will bring up the menu display. The menu can be operated using the, and -buttons on the instrument bridge. From the user selection you can choose the user and utilise saved settings. Avertissement! L''intérieur du boîtier de jonction est soumis à des niveaux dang d'air et d'eau sous pression. Seul un technicien de maintenance habilité à ouvrir le boîtier de jonction. Remarque! Lorsque l'appareil est allumé, la tablette d'instruments, le module d'a et la boîte de jonction sont soumis à de l'eau et de l'air sous pression Commutateur de mise sous tension Commutateur de mise sous tension Le dispositif est mis en marche ou arrêté grâce au commutateur de m Celui-ci contrôle toute l'électricité du dispositif. Si le commutateur est dispositif peut se faire sans danger. Lorsque le système n'est pas so l'eau à l'intérieur du dispositif sont dépressurisés. 3.2 Sélection de l'utilisateur Selecting the user Appuyer sur la touche de la tablette d'instruments et la mainten fiche le menu présenté à la figure suivante. MENU. TIMER USER CLOCK CART MOVE FLUSH (i ) Affichage du menu Cleaning and disinfecting Disinfecting the suction system insert the suction hoses to the connectors in the bottom of the cuspidor remove the filling hole lid pour the disinfectant solution into the filling hole wait until the solution has gone through the suction hoses. replace the suction hoses. All instrument flushing To start the all instrument flushing operation, press and hold the -button until the flush-menu appears. Insert instruments to the instrument flushing -holder. From the flush-menu, select the suitable time for flushing. The options are: 30 seconds, 3 minutes and 10 minutes. The min +1 and min -1 menu items adjust the 10 minute time accordingly. The water can be taken from the clean water bottle or from mains water. It is also possible to use a disinfection solution in the clean water bottle. After flushing with the desinfectant flush with fresh water before treatment. G

Quick start Switch the power on The main power switch is located in the connection box. Using pre-set s Press the -button to recall the pre-set s. Select the desired memory slot (,,, ) with the corresponding button from the instrument panel to recall the. Chair to working 1 (the backrest up, working while sitting) Chair to spitting Chair to entry and exit Chair to working 2 (the backrest up, working while standing) Switching power on Power switch Selecting the memory slot Pre-set button Position the chair The chair can be operated with joystick(s), remote foot, instrument bridge buttons, and suction head buttons. Positioning the chair Position the headrest The distance between the headrest and backrest can be adjusted simply by sliding the headrest in or out. Positioning the headrest The movements of the headrest are double articulated. Use the lever to lock the mechanism. Turning and detaching armrests Lift the armrest slightly. Turn it 900. Detach the armrest in this. Turning and detaching armrests 13:57 01.05.2011

Safety precautions Electricity and pressurised water and air Do not open the door of the cuspidor during the patient treatment to prevent the risk of an electric shock. The maximum connection voltage to the relays for the external devices is 24V. There are harmful voltage levels, pressurized air, and water inside the connection box. The connection box may be opened only by an authorized service person. To avoid the risk of an electric shock, this equipment must only be connected to supply mains with the protective earth. Connecting devices not compliant with IEC 60601-1 or IEC 60950 may cause an electric shock hazard. Do not touch non-medical devices simultaneously with the patient. There is a risk of electric shock. Only qualified service personnel is allowed to replace the remote foot s rechargeable batteries. Treating patients Check that there is water and not disinfecting solution in the clean water bottle before the treatment. Flush the water lines with fresh water before treating patients after using disinfection solutions. Follow the disinfectant liquid manufacturer s instructions. To avoid the risk of fire, this equipment must not be used with flammable anaesthetics. Using the chair Check that nothing is obstructing the movements of the chair to prevent damage to the system. Beware of damaging the instrument bridge arms when lifting the backrest of the chair. Do not sit on the backrest or footrest. They may bend under your weight. Check the tightness of the locking mechanism after adjusting the of the headrest. Instruments Check that the scaler gets water for cooling. The scaler may get damaged if it is not cooled. Avoid looking straight at the curing light because it may damage your eyes. Check the locking of the instrument drill bit mechanism after replacing the drill bit. The operating light Do not look straight into the operating light. Staring the light beam may cause damage to eyes. Maintenance and cleaning The display is not water proof. Beware wetting the display when cleaning the system. Use only bottles provided by Fimet Oy. Otherwise there is a possibility that the bottle breaks. Be cautious when using flammable disinfection/cleaning agents because of the risk of fire. Do not smoke or handle fire when handling flammable agents. Using instruments which are not disinfected or sterilised may cause infection hazard to the patient or operator. Follow the instrument manufacturer s instructions on disinfection and sterilisation. More information More information about using the Fimet Neo system is in the user guide. The user quide can be obtained from www.fimet.fi/media/neouserguideen.pdf 3/2014/ek Fimet Oy Teollisuustie 6 FI-07230 Monninkylä Finland Tel: +358 19 521 6600 Fax: +358 19 521 6666 fimet@fimet.fi www.fimet.fi