METASYS. Central Suction System EXCOM hybrid 2/5. Equipment Logbook Assembly, operation and maintenance

Similar documents
ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

ECO II. Economy System Typ 2. Amalgamabscheider ECO II/ECO II Tandem ECO II D/ECO II Tandem D Gerätedokument Einbau, Betrieb und Wartung

INSTALLATION PROOF REGISTER YOUR PRODUCT. for warranty claims STAMP. Dealer. Date. here. Please complete and return. For the dental office:

METASYS. Amalgam Separator COMPACT A8 / A16. Installation, operation and maintenance

REGISTER YOUR PRODUCT. for warranty claims INSTALLATION PROOF. Please complete and return

ECO MST 1. Separierautomatik MULTI SYSTEM TYP 1 ECO Gerätedokument Einbau, Betrieb und Wartung

CENTRAL SUCTION SYSTEMS. Dry / semi-wet suction For 1-15 dental units Underpressure of 180 mbar

METASYS. Amalgam separator ECONOMY SYSTEM TYPE 2 ECO II. Installation, operation and maintenance

INSTALLATION INSTRUCTIONS DÜRR MOTORSEPA S 300

Light oil burners. One stage operation

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

GB Installation instructions DÜRR Combi-Separator 7110

HEAT RECOVERY AIR HANDLING UNIT

Surgical Suction: Silent and powerful!

DÜRR SUCTION SYSTEMS. High demands reliably exceeded DÜRR AMALGAM SEPARATORS

Oil burners Brûleurs fioul Stookoliebranders

IDE 20 / IDE 30 / IDE 50 IDE 60 / IDE 80

INSTALLATION AND OPERATING INSTRUCTIONS

Supplementary Operating Manual for Cutting mill combination

ORIGINAL INSTRUCTIONS

h is ngl E ASSISTANCE CENTRE AUTHORIZED RETAILER

SILENT compact /

Millo / Millo pro. Nr x000 / 1805-x000

TTV 4500 / TTV 4500 HP / TTV 7000

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Top suction machines DÜRR VS SUCTION SYSTEMS FOR THE DENTAL PRACTICE. VS Combination Suction Units VS 300 S VSA 300 S VS 600 VS 900

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

CEMENT MIXER MODEL NO: CCM134L OPERATION & MAINTENANCE INSTRUCTIONS PART NO: GC0514

Instructions manual DEHUMID HP50

RONDA 2-58 Duo Heavy Duty Industrial Vacuum Cleaner For Liquid Filtration and Transport

OPERATION AND MONTAGE MANUAL ROOF FANS

Installation & Operation

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

SEPTIC FLUID ASPIRATOR MEDAP-VENTA SP 26 N MEDAP-VENTA SP 26 A

V80-H Multistage Pump Instruction Manual

Acquaer Ltd. H-4900, Fehérgyarmat, Szatmári út 11. CENTRIFUGAL PUMP Instruction Manual ACm60 / ACm75 / ACm150 / ACm150B2

AS Medizintechnik GmbH Sattlerstrasse 15, Tuttlingen, Germany Tel 07461/ Fax 07461/

Moisture inside the drum is due to final testing.

MODEL 7000 SUCTION UNIT

Oil Mist Separator Unit LGA 600 FUW

VETO CLEANER 500 FLUE GAS CLEANER

Dental Unit User's Guide

1. Take the hoses and elbow out of the holders, depending on model. max. 100 cm. min. * cm

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Parts Available from

USER AND MAINTENANCE MANUAL

VS suction systems for the dental practice Top suction machines. VS Combination Suction Units

OPERATION AND MONTAGE MANUAL ROOF FANS

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

VADA - V80-H PRODUCT OVERVIEW CONSTRUCTION USAGE LIMITATIONS MOTOR WARRANTY

Rotary Tube Furnaces

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

Tornado Operations & Maintenance Manual

Manual. Atomizer Air Humidifiers. Type DG4 / DG8

Instructions for use. BA Optima. Air motors BA602 (BA640081) BA604 (BA640060)

DS English... 5 Français Español CONSUMO DE ENERGIA. 1. En Operación: 287,82 Wh 2. En Modo de Espera: N/A Modelo: DS 5.

OIL TREATMENT ARRAS MAXEI

Instruction manual ASPIMAX 16

Washing machine PW 5064 MOPSTAR 60. en - GB. Installation plan

Decentralised ventilation units

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Oil Mist Separator Unit LGA 600 FUW

Short Instruction for Use for in-home care ASSKEA procuff M and ASSKEA procuff S

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Operating Instructions for Fristam Powder Mixer

FINO JETSTEAM PRO 52072

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

AIR HEATING UNIT HEATMASTER ACJB INSTALLATION, OPERATION, MAINTENANCE AND SPARE PARTS

Operating Guide. Termix Compact 28 VX-FI / HWP / HWS. 1.0 Table of Contents. 1.0 Table of Contents

Tornado Operations & Maintenance Manual

Washing machine PW 6055 AV/LP PW 6065 AV/LP. en - GB. Installation plan

Light oil / kerosene burner

Coffee Machine Zia series

OIL TREATMENT ARRAS MAXEI

Guide book ASPIMAX 32. Im Geer 20, Isselburg. Type No.: 403. Serial No.:...

Silent TS. Nr / Ideas for dental technology / A. Made in Germany

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

Faster BH-EN and BHG Class II Microbiological Safety Cabinets

Part No KEMPER Filter-Master XL

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

Operating Instructions

TECHNICAL SPECIFICATIONS - CW-80T AUSTRALIAN, EUROPEAN, SOUTH AFRICAN & UK

Instructions. Portable Absorb Phlegm. Apparatus

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

brands you trust. Pumps for hazardous materials Type GUP 3-1,5 & GP 20/10 Ex

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

INSTRUCTIONS CertoClav EL

USER GUIDE ENGLISH TOPSTART Ref. TSWZ, TSWRS or TSG Between 0.5 and 3 kw

SURGICAL ASPIRATOR FOR THE OPERATING THEATRE MEDAP-TWISTA SP 1070

Millo / Millo pro. Nr x000 / 1805-x000

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

OPERATION & MAINTENANCE MANUAL MODEL SC-924A SELF-CONTAINED ELECTRONIC AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

AS 50 operating manual, 2013

We ve invented suction. Again. The radial Tyscor V/VS suction machine COMPRESSED AIR SUCTION IMAGING DENTAL CARE 50 % HYGIENE. potential energy saving

Nilfisk Inc Winnetka Avenue North Minneapolis, MN REV.03( ) VF80189

FUTURE AIR SOLUTIONS OIL FREE SCROLL COMPRESSORS

Transcription:

METASYS Central Suction System EXCOM hybrid 2/5 Equipment Logbook Assembly, operation and maintenance

Index Explanation of the pictograms The footnote found on each page defines the user group particular information is aimed at. 1. Index: Page 1. Index 2 2. Explanation of the pictograms 2 3. General information 3 4. Use 4 5. Type overview 4 6. Construction 5 7. Accessories 6 8. Explanation of the type plate 7 9. Technical data 8 10. Description of function 9 11. Installation guidelines 10 12. Hose connections 11 13. Electrical connections 12 14. Connection COMPACT A8 / A16 with EXCOM hybrid 2/5 14 15. Maintenance, cleaning and disinfection 15 16. Commissioning 16 17. Maintenance 17 18. Disposal of the equipment 17 2. Explanation of the pictograms Warning that to ignore the following instructions could lead to personal injury, disrupt operation or damage the apparatus! means that particular attention is drawn to an important situation for the operating personnel or the technician. 2 Page Practice staff / technicians

General information 3. General information: The safety, reliability and performance of the equipment is only guaranteed by METASYS if the following instructions are observed: q Assembly, alterations or repairs may exclusively be carried out by authorized service personnel in compliance with EN Standard 60601-1 (International Standard for Medical Electrical Apparatus, in particular Part 1: General Rules for Safety). q The electrical installation must comply with the regulations of the IEC (International Commission for Electrical Engineering). q The appliance must exclusively be used in conformity with the instructions for installation, operation and maintenance. q Only original parts may be used for repairs or replacements. q All instructions issued by manufacturers of equipment for the treatment of patients which is connected to the suction engine must be observed. Following the commissioning of the apparatus, the Installation Proof must be completed and returned to METASYS in order to establish the guarantee period. q Every service and inspection must be recorded in the Equipment Logbook. q When requested by an authorized engineer, METASYS agrees to make all documents available for the use of technically qualified service personnel. q METASYS accepts no responsibility for damages caused due to external factors, such as wrong installation, improper use of the apparatus or unauthorized technical intervention. The equipment is not suitable for use in explosive or combustible environment. q Users must study equipment and assure themselves of its good condition before every use. Practice staff / technicians Page 3

Use Type overview 4. Use: The METASYS EXCOM hybrid is a central suction system used for centralised vacuum production, as well as the separation of air and liquids in dentistry. The EXCOM hybrid central suction system is a vacuum engine with integrated separation. It can be operated both as semi-wet or dry suction system. 1 5. Type overview: The EXCOM hybrid central suction system can be delivered in four models: 1 EXCOM hybrid 2-230V 2 EXCOM hybrid 2-400V 2 EXCOM hybrid 2: EXCOM hybrid 2 is a central suction system with integrated air/water separation for simultaneous operation of 2 treatment units or for up to 3 treatment units with 60% efficiency. 3 EXCOM hybrid 5-230V 4 EXCOM hybrid 5-400V EXCOM hybrid 5: EXCOM hybrid 5 is a central suction system with integrated air/water separation for simultaneous operation of 3 treatment units or for up to 5 treatment units with 60% efficiency. 3 4 4 Page Practice staff / technicians

Construction 6. Construction: 5 See illustration taking EXCOM hybrid 5 as an example 5.3 5.1 The suction engine with dynamic separation unit The suction engine is a powerful dry vacuum engine operating according to the principle of the side channel vacuum pump. The dynamic separation unit centrally separates liquids and solids from the air stream without interruption of the suction's output. This eliminates the need for a separator in the treatment unit. 5.5 Noise reducing item for air inlet valve 5.2 Control unit The control unit contains all electrical components necessary to control and monitor the entire device. 5.4 5.3 Air inlet valve + Noise reducing item The air inlet valve optimises the vacuum and protects the suction equipment from overheating. + Noise reducing item for air inlet valve 5.6 5.4 Prefilter Coarse solid particles are held back in the prefilter 5.5 Hose connections 5.1 5.6 Water collector The water collector protects the suction pump from water backdraft. 5.2 5 Practice staff / technicians Page 5

Accessories 7. Optional accessories available: 1 See illustration External place selection valve Order number: 40050048 1 Without integrated selective control air can be entrained through unused open hose connection points of operating suction systems. Distracting noises and loss of suction power can be the result. The installation of a place selection valve prevents this effect. 2 See illustration Spittoon valve: Order number: 40050002 2 If the treatment unit has a spittoon bowl, the water from the bowl must be discharged through the suction hose. The installation of a spittoon valve prevents distracting sucking noises and loss of suction through the bowl. The spittoon valve operates automatically and sets off the central suction system. 3 See illustration Covering hood: Covering hood for EXCOM hybrid 2/5: Order number: 40030004 3 The covering hood minimizes the sound level from the vacuum motor and protects the suction system from external influences. 4 See illustration Air bio filter: Air bio filter for EXCOM hybrid 2/5: Order number: 40060002 Air bio filter for EXCOM hybrid 2/5: Order number: 40060003 4 For reasons of hygiene and noise reduction we recommend the intregration of an air bio filter into the air-discharge connection and to lead it out of doors. 5 See illustration Noise reducing item for air inlet valve (included in scope of delivery) Order number: 40040007 The noise reducing item minimizes the sound level of the air inlet valve. 5 6 Page Practice staff / technicians

Explanation of the type plate 8. Explanation of the type plate: 6 See illustration Type plate of EXCOM hybrid 2/5: The type plate can be found at the outside of the suction motor's silencer 6.1, above the prefilter 6.2. 7 See illustration Explanation of the type plate, taking EXCOM hybrid 5-230 V as an example: 6.2 7.1 Equipment name 7.2 Connection data 7.3 Serial number 7.4 Manufacturer s address 7.5 CE mark 7.6 Separate collection electrical/electronic equipment 7.7 ÜZVO conformity mark 7.8 Protection class 1 6.1 6 7.1 7.3 7.5 EXCOM hybrid 5 U n = 230V, 50/60 Hz P max = 1,1/1,3 kw pmax = 180 mbar *reguliert EA-12345 000 METASYS Medizintechnik GmbH A-6063 Rum bei Innsbruck, Florianistr. 3 Made in Austria 7.2 7.8 7.4 7.7 7.6 7 Practice staff / technicians Page 7

Technical data 9. Technical data: 1 EXCOM hybrid 2 230 V 400 V Mains voltage: 230 V AC 400 V AC Frequency: 50/60 Hz 50/60 Hz Maximum current consumption: 6,5/7,4 A 2,5/2,8 A Electrical shaft power: 0,75/0,9 kw 0,75/0,9 kw Suction motor rotation speed, rpm: 2770/3250 2780/3300 Vacuum, regulated: 180 mbar 180 mbar Maximum ambient temperature: 40º C 40º C Operating time: 100% 100% Weight: 31 kg 32 kg Noise level without covering hood: 63 db (A) 63 db (A) Noise level with covering hood: 58 db (A) 58 db (A) Overall dimensions (L x W x H) cm: 441 x 342 x 620 441 x 342 x 620 1 2 EXCOM hybrid 5 230 V 400 V Mains voltage: 230 V AC 400 V AC Frequency: 50/60 Hz 50/60 Hz Maximum current consumption: 9,2/7,9 A 3,3/3,7 A Electrical shaft power: 1,1/1,3 kw 1,1/1,3 kw Suction motor rotation speed, rpm: 2800/3300 2880/3400 Vacuum, regulated: 180 mbar 180 mbar Maximum ambient temperature: 40º C 40º C Operating time: 100% 100% Weight: 34 kg 35 kg Noise level without covering hood: 65 db (A) 65 db (A) Noise level with covering hood: 58 db (A) 58 db (A) Overall dimensions (L x W x H) cm: 499x 363 x 626 499x 363 x 626 2 8 Page Practice staff / technicians

Description of function 10. Description of function: 3 See illustration 3.1 3.5 On removing a suction hose from its rest in the treatment unit, the dynamic separation 3.1 and the EXCOM hybrid central system suction engine 3.2 start. After the vacuum has been developed, the optionally available place selection valve for the treatment place in use opens. The water from the cuspidor or spittoon runs through the spittoon bowl into the suction hose, which also starts the EXCOM hybrid central suction system. 3.6 3.4 The mixture of liquids, solids and air sucked from the treatment units flows through the suction connection 3.3 and prefilter 3.4 into the separation chamber 3.1. The mixture is accelerated into a circular movement by the rapidly rotating impeller blades. The liquids and solids are tangentially centrifuged, whilst the air flows through the blade shafts into the hose connection with the air inlet valve 3.5 into the suction engine 3.2. The dry air is discharged via the optional bio-filter into the atmosphere through the exhaust air connection 3.6. The factorymade follow-up time of the dynamic air / water separation and of the suction motor is approx. 60 seconds. This can be extended according to the installation situation. 3.7 The centrifuged liquids and solid particles smaller than the mesh of the pre-filters 3.4 are either led into the normal sewage system via the water outlet 3.7 and the drainage connection or directed into an amalgam separator (COMPACT A8/A16 or ECO II). 3.2 3.3 3.2 3.1 3.6 3.7 3.5 3.3 3 Practice staff / technicians Page 9

Installation guidelines 11. Installation guidelines: 15 cm q The EXCOM hybrid suction system is designed to be installed only in dry, adequately ventilated rooms. Its use in areas subject to explosive and fire hazards is not permitted. q The permitted room temperature ranges from between +10 C and +40 C. The relative humidity must not exceed 70%. q In case of a room temperature of more than +35 C, a fan must be installed for additional ventilation. q Installation can be on the same level as the treatment units, in a side room or one floor lower. 1 In order to avoid vibrations, the suction system must be installed on a firm base. 1/1 1 See illustration q When the EXCOM hybrid suction system is installed, the connection side must be placed at least 15 cm from the wall so that the hoses can be connected. 2 EA-54.202/00 D Während des Saugvorgangs, darf der Hauptschalter nicht ausgeschaltet werden. While suction is used, the device must not be switched off at the main switch. I Mentre la pompa è in funzionamento, non bisogna in alcun caso spegnere o interrompere il sistema d aspirazione EXCOM premendo l interuttore dell EXCOM stessa. F Ne pas éteindre l interrupteur principal pendant le fonctionnement de l appareil. E No desconectar el interruptor principal mientras el equipo esté en marcha. EA-54.201/00 2 See illustration q The front of the device must be easily accessible. If the EXCOM hybrid system is installed with the covering hood, nothing must be placed on top of it. To allow the removal of the covering hood, a free space above equal to the equipment's height equal to half its width at the sides is required. There must be clear space of approx. 5 cm around the device to guarantee adequate air circulation. Do not lift the device! While the suction is used, the device must not be switched off at the main switch! 3 Air inlet valve: The suction power of a central suction system can fluctuate if only the spittoon valve without a suction cannula is operated. This can affect the transport of the liquids. To optimize the transport of liquids, an air-inlet valve (Item No. 40040006) needs to be installed in the dental unit. This ensures an air-flow of approx. 100 l/min during operation. This measure guarantees the safe transport of waste water from the spittoon bowl through the suction pipes. Pipe and hose installation: 3 Any pipe or hose used must be vacuum tight and resistant to all chemicals normally used in a dental practice (e.g. HT discharge pipes made from PP, PVC-C, PVC-U, PE-HD). 10 Page Practice staff / technicians

Installation guidelines Hose connections 4 See illustration q Only flexible spiral hoses made from PVC or equivalent materials may be used. q Connections to the EXCOM hybrid central suction system must be made by flexible hoses and be as short as possible. 90 q We recommend a pipe diameter of 40 mm. Avoid right-angle bends in order not to lose suction power (recommendation: 2 x 45º degree bends). q Discharge pipes must meet applicable local legislation or DIN 1986, Parts 1 and 2. 2 x 45 q Waste water must be allowed to drain off freely without any backup. Waste water pipes must have a hydraulic gradient of at least 2%. q The air must be discharged out-of-doors. For reasons of hygiene and in order to avoid noise pollution we recommend that the outgoing air connection is fitted with a bio-filter. q The diameter of the discharged air connection must be equal to or bigger than the diameter of the suction connection. min. 2% 12. Hose connections 4 5 EXCOM hybrid 2/5 5.1 Connection for the suction hose (from the treatment units): 40 mm diameter 5.2 Connection for exhaust air EXCOM hybrid 2: 40 mm diameter EXCOM hybrid 5: 50 mm diameter 5.3 Connection for waste water (clean water discharge): 15 mm diameter. 5.2 All hose connections must be secured with hose clamps! For the exhaust air connections only heat-resistant ( 130 C) hose and pipe material must be used. In case of water discharge at the water collector all connections, especially the water discharge pipe, must be checked. 5.3 5.1 5 Practice staff / technicians Page 11

Electrical connections 13. Electrical connections: Mains connection: The mains connection must only be carried out by a trained electrician. The electrical installation must be carried out in accordance with applicable local regulations. Before connecting with the mains, the nominal voltage stated on the type plate on the equipment must be compared with the mains voltage. The EXCOM hybrid suction system must only be connected to the power supply with the supplied power cable. Extension cables must not be used. Main switch: Connection to the mains must be established after the practice's main switch. 1 Circuit diagram EXCOM hybrid - 230V 2 Circuit diagram EXCOM hybrid - 400V 1 Legend: F1 fuse T2A K1 motor contactor K2 timing relay M1 motor for vac Q1 protection switch S1 main switch T1 transformer V1 varistor K275 2 12 Page Practice Technicians staff / technicians

Operating components The hose rest signal: The control cable for the hose rest signal light is already connected internally by a 2 pole cable, 3 metres long. The suction system starts when the two contacts are connected. The control cable is to be properly fixed into a junction box. K1 K2 Follow-up time: F1 S1 The factory-made follow-up time of the suction system is approx. 60 seconds. By turning the knob on the timing relay this running time can be adjusted. W2 3 Control unit EXCOM hybrid - 230V 4 Control unit EXCOM hybrid - 400V W1 V1 Legend: W3 F1 fuse K1 motor contactor K2 timing relay S1 main switch T1 transformer V1 varistor W1 power supply W2 motor for vac W3 sucking contact 3 T1 T1 S1 W1 W2 F1 W3 4 K1 K2 Practice Technicians staff / technicians Page 13

Connection COMPACT A8/A16 with EXCOM hybrid 2/5 14. Connection of the amalgam separators COMPACT A8/ A16 with EXCOM hybrid 2/5: 1 Connection of the sewerage tubes and pipes 1 min. 2% max. 0,4 m 2 Optional installation expansion container In case of high volumes of liquid and spontaneously fulminating large quantities of water an expansion container (Item No. 40040014) needs to be installed between the suction system (EXCOM hybrid) and the amalgam separator (METASYS COMPACT A8/A16). 2.1 amalgam separator 2.2 2.3 2.4 2.2 expansion container 2.3 bleeding valve 2.1 2.4 suction system 2.5 air in 2.6 min. 2% min. 2% 2.5 2.6 water out min. 2% max. 0,4 m 2 14 Page Practice staff / technicians

Maintenance, cleaning and disinfection with GREEN&CLEAN M2 Changing the collection container: see COMPACT A8/A16 "Installation, Operating and Maintenance Manual" Disposal of the collection container when full: see COMPACT A8/A16 "Installation, Operating and Maintenance Manual" 15. Maintenance, cleaning and disinfection: with METASYS GREEN&CLEAN M2 cleaning and disinfection agent for suction equipment and amalgam separators. 3 See illustration Following every operation, the rinsing basin must be rinsed thoroughly! 4 See illustration Suck off some water with each of the suction tubes after every treatment! 5 See illustration Twice a day, after having sucked off some water, use the disinfectant for amalgam separators Green&Clean M2. Ideally a disinfection with Green&Clean M2 should be carried out before longer periods of downtimes of the dental unit (e.g. lunch break, working day or holidays). 6 See illustration The spittoon bowl should also be rinsed with GREEN&CLEAN M2 twice a day. q Cleaning the filter At least once a week clean and empty the filter. The cleanout can also be carried out more frequently if necessary. 7 See illustration Any residues from the prefilter, which might contain amalgam, must be collected in a suitable container (e.g. METASYS EcoCenter) and disposed off properly with EcoTransform. 3 4 5 6 Please go to www.metasys.com to locate a world-wide collection point in your vicinity. 7 Practice staff / technicians Page 15

Commissioning 16. Commissioning: 1 See illustration q Switch on practice and the equipment main switch. 1 2 See illustration q Remove the suction hose from its holder. q Check that all hose connections and other connections in the suction pipe are air-tight. 2 3 Adjust the air-inlet valve see illustration q The suction flow at the large sucker should be at least 300 l/min. q Adjustments are made by turning the adjustment screw on the air-inlet valve whilst measuring the air flow at the large suction tip using a vacuum gauge*. * Digital Manometer ECO 1: Order No.: 40400005 Protective covering for Manometer: Order No.: 40400006 3 Negative pressure with air-inlet valve: 180 (-20) mbar 4 See illustration q Suck 3 litres of water and check that the EXCOM hybrid central suction system is operating correctly. q Undertake electrical safety checks as required by local legislation, and record that the checks have been made. 4 16 Page Practice staff / technicians

Maintenance Equipment disposal 17. Maintenance: 5 See illustration q The following filters must be checked and cleaned every week: á The filter in the hose rest or the suction hose not illustrated. á The filter in spittoon bowl outlet and the spittoon valve 5.1 á The base filter 5.2 q Cleaning the filters: The prefilters must be cleaned at least once a week. However, depending on the method of working, this may be necessary every day. A clogged prefilter is perceivable by a reduction of suction power. q Exhaust air filters: The optional exhaust air bio-filter must be changed at least once a year. 5.1 18. Disposal of the equipment: The devices may be contaminated. Please inform the disposal company of this so that the necessary precautions can be taken. Disposal of amalgam separator components, such as sieves, filters, hoses etc., must also comply with local regulations. Uncontaminated plastic components of the suction system may be recycled. The built-in control unit, electronic circuit boards and components may be disposed of as electro-technical scrap. Other metal components may be disposed of as ordinary metal scrap. 1 2 If the device is returned, for example to the dealer or METASYS Medizintechnik GmbH, all connections must be sealed so that they are water-tight. 5.2 5 Practice staff / technicians Page 17

Notes 18 Page Practice staff / technicians

Notes Practice staff / technicians Page 19

METASYS Austria METASYS Medizintechnik GmbH Florianistraße 3 A-6063 Rum bei Innsbruck 1+43/(0)512 /20 54 20-0 5 +43/(0)512/20 54 20-7 Germany METASYS Medizintechnik GmbH Ahornstraße 19 D-85614 Kirchseeon 1+49/(0)2236 / 37 42 42 5+49/(0)2236 / 37 42 41 France METASYS France S.a.r.l. 9, bd E. Michelet F-69008 Lyon 1+33/(0)4/37 90 22 15 5 +33/(0)4/37 90 22 47 e-mail: info@metasys.fr www.metasys.fr email: info@metasys.com www.metasys.com Italy Dental ECO Service Italia S.r.l. Florianistraße 3 A-6063 Rum bei Innsbruck 1 +39/045/981 4477 5 +39/045/981 4475 e-mail: desitalia@metasys.com EBW EXCOM hybrid D//FR/I, 19.03.2012 70100031 ZK-55.064/00 Subject to technical changes, printing and setting errors