L1L2L3. 99 Washington Street Melrose, MA Phone Toll Free Visit us at

Similar documents
275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

CA870 INFRARED THERMOMETER E N G L I S H. User Manual. Auto OFF

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

DIGITAL / ANALOG MEGOHMMETERS 1030

MW Pince courant de fuite Leakage current Clampmeter. Notice d utilisation User s Manual M3950M00

Analog Melting Point Apparatus

LV-5 Direct Contact Low Voltage Detector and LV-5/K01 Kit including LV-PT Tester, Holster and Available Accessories

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Instruction Manual Analog Vortex Mixer with Fixed Cup Head

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

62 MAX/62 MAX + Infrared Thermometer

10A Micro-Ohmmeter Model 6250

Hi-Temp Bath Installation and Operation Manual

Aluminum Heating Mantles

User Guide. Luxxor. 35 LED Light Source Fax: Tremont Street, Rochester, New York gradientlens.

GigaCore RPSU. Redundant power supply for GigaCore 14R and 16Xt. Quick Start Guide. V2.0.0 Rev1. English

Digi-Sense TC9000 Advanced PID and On/Off Temperature Controller with Thermocouple Input

OPTISENS TUR 2000 Technical Datasheet

LC2200 Level Controller Installation and Maintenance Instructions

Visit us at

Instruction Manual. Mini Hotplate Mini Stirrer Mini Hotplate Stirrer

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com HCT-900. HCT-900 User Guide _C

GETTING STARTED GUIDE NI DI, 30 V, Sourcing, 7 μs

10A Micro-Ohmmeter Model 6250

GigaCore 12. Gigabit Ethernet Switch for the entertainment industry. Quick Start Guide. V2.1.0 Rev5. English

Instruction Manual. Model AccuPlate Hotplate AccuPlate Stirrers AccuPlate Hotplate Stirrer 12/10 CLS-EQ-LHP01REV

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

Thermohygrometer with Single Type K Input and Superheat Function

Instruction Manual M6627 / Version 7.4. Slide Drying Bench MH6616 MH6616X1

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

Instruction Manual Mini Hotplate Mini Stirrer Mini Hotplate-Stirrer Mini Auto Stirrer Mini Fixed Temperature Hotplate

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

OPERATING MANUAL TORREY PINES SCIENTIFIC, INC. DIGITAL HPLC COLUMN HEATER MODEL CO20 DOCUMENT NUMBER CO20-00

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Operator s Manual. The Bullet Blender 50 BB50-AU, BB50-DX. Contents. Congratulations!

62 MAX/62 MAX + Infrared Thermometer

INSTRUCTIONS FOR THE LCR10 TEN INCH CIRCULAR CHART RECORDER

BD Viper Lysing Heater Manual (for BD Viper System)

YELLOW JACKET. H 2 Tracer Gas Leak Detector. Operations Manual. Detects 5% H 2 in 95% Nitrogen Tracer Gas. Model 69341

Keysight U1241B and U1242B Handheld Digital Multimeter. Quick Start Guide

INSTRUCTIONS FOR OPERATION AND CARE OF

SET-2000 Hi Level/Oil

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Archive. LC2200 Level Controller. 1. Safety information. 2. General product information. 3. Installation. 4. Setting up the controller

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

FastGene Plate Centrifuge. Instruction Manual. Catalog No. NG

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Keysight U8030A Series Triple Output DC Power Supply

Water Bath SWB1 SWB2 SWB3 SWB1D SWB2D SWB3D. Instructions for use Version 2.0. water bath SWB2D. mains on on. press to set. set. off.

SimpleVIS Viscometer Reference Guide P

Certificate of Compliance

PH1000T PH1500T PH2000T

GETTING STARTED GUIDE NI TC, ±78 mv, 24 Bit, 75 S/s Aggregate

Lawnmowers (pedestrian controlled electric mains-powered)

Industrial Solid State Contactor TE10S. Static switching of resistive loads and shortwave infrared heating tubes up to 20 kw

GETTING STARTED GUIDE NI Channel, 0 ma to 20 ma, 16-Bit Analog Output Module. This document explains how to connect to the NI 9265.

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

OilSET Installation and Operating Instructions. Oil Separator Alarm Device

INSTALLATION AND OPERATION MANUAL

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

Operator s Manual. IP-100 Immersion Probe Cooler

Instruction Manual. For All Corning Hot Plates, Stirrers, Stirrer/Hot Plates with Digital Displays, and External Temperature Controller (6795PR)

User Manual for AirFlow Convection Oven

Corning LSE Benchtop Shaking Incubator

Millo / Millo pro. Nr x000 / 1805-x000. Ideen für die Dentaltechnik A

3M Overhead Ionizing Blower 991A

Owner & Operator s Manual. Table of Contents

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

Package Contents. Dry Block Heater Power Cord Instruction manual Warranty Card. Serial Number: Date of Purchase: Supplier: Table of Contents

Operating Instructions

Instructions for the fan motor control system with integrated wiring terminals SILVER C

Certificate of Compliance

LV-S-5. Instruction Manual DIRECT CONTACT STRAY VOLTAGE DETECTOR GENERAL DESCRIPTION HOW IT WORKS

Vacuum cleaner Instruction manual

MD-MINI Dry Bath. Instruction Manual

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Digital Heat Block User Manual

Rapid Heat Sterilizers with 6, 8, and 12 Minute Sterilization Cycle Times

RE-PR3-E-27 3-Phase Panel Mount 27kW

Series: MBC1-TC Mini Benchtop Temperature Controller

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

Druck DPI 705/DPI 705 IS Series

MBCE-110/230UV Flame Sensor Module

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Mini Tower Fan NSMTF-18

Flameproof Manual Call Points

SET-2000 Oil/Sludge. Alarm Device for Oil Separators. Installation and Operating Instructions

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Operating Instructions

TSXAEY1614C analog input module - 16 inputs - thermocouple - 16 bits

Händetrockner Hand dryer Sèche-mains Handendroger Osoučeč rukou Suszarka do rąk Сушилки для рук Kézi szárító

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

200W Frostwatch Radiant Heater Operation Manual

LC3000 Level Controller Installation and Maintenance Instructions

MODEL WIND TRACKER

actoolsupply.com User Guide Extech RD300 Air Conditioning AC Refrigerant Leak Detector Refrigerant Leakage Detector Model RD300 actoolsupply.

! WARNING. Before using product, read and understand instructions.

PAC1500Xi PORTABLE APPLIANCE CHECKER

Transcription:

PHASE ROTATION METER 6608 L1/A L2/B 690V 600V CAT III 300V CAT IV L1L2L3 L3/C L R PHASE ROTATION MODEL 6608 User Manual 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards. We guarantee that at the time of shipping your instrument has met its published specifications. The recommended verification interval for this instrument is 12 months and begins on the date of receipt by the customer. Serial #: Catalog #: 2121.10 Model #: 6608 Please fill in the appropriate date as indicated: Date Received: Date Verification Due: Chauvin Arnoux, Inc. d.b.a AEMC Instruments

Table of Contents 1. INTRODUCTION...2 1.1 International Electrical Symbols...3 1.2 Definition of Measurement Categories...3 1.3 Receiving Your Shipment...4 1.4 Ordering Information...4 1.4.1 Accessories and Replacement Parts...4 2. PRODUCT FEATURES...5 2.1 Description...5 2.2 Control Features...5 3. SPECIFICATIONS...6 4. OPERATION...7 4.1 Phase Rotation Direction...7 5. MAINTENANCE...8 5.1 Cleaning...8 Repair and Calibration...9 Technical and Sales Assistance...9 Limited Warranty...10 Warranty Repairs...10

CHAPTER 1 INTRODUCTION Warning This instrument complies with safety standard IEC 61010-1, Ed 2 of February 2001. For your own safety, and to prevent any damage to your instrument, you must follow the instructions given in this manual. This instrument can be used on category III electrical circuits not exceeding 600V with respect to earth. It must be used indoors, in an environment not exceeding pollution level 2, at an altitude of not more than 2000m. The instrument can therefore be used in complete safety on 400V and 690V three-phase networks in an industrial environment. For safety reasons, you must use only measurement leads having a voltage rating and category at least equal to those of the instrument and compliant with standard IEC 61010-031. Do not use if the housing is damaged or not correctly closed. Do not place your fingers near unused terminals. If the instrument is used other than as specified in this manual, the protection provided by the instrument may be impaired. Do not use this instrument if it seems to be damaged. Check the integrity of the insulation of the leads and of the housing. Replace damaged leads. Be prudent when working in the presence of voltages exceeding 70Vdc or 33Vrms and 46.7Vpp; such voltages can cause a risk of electrocution. The use of individual protections is recommended in some cases. Always keep your hands behind the physical guards of the probe tips or alligator clips. Always disconnect all leads from the measurement and from the instrument before opening the housing. 2 Phase Rotation Meter Model 6608

1.1 International Electrical Symbols Instrument is protected by double or reinforced insulation. CAUTION - DANGER! Read the User Manual. Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous. The CE marking guarantees conformity with European directives and with regulations covering EMC. The trash can with a line through it means that in the European Union, the product must undergo selective disposal for the recycling of electric and electronic material, in compliance with Directive WEEE 2002/96/EC. 1.2 Definition of Measurement Categories CAT I: CAT II: CAT III: CAT IV: Measurement category I corresponds to measurements taken on circuits not directly connected to the network. Measurement category II corresponds to measurements taken on circuits directly connected to the installation. Example: measurement for electrodomestic units, portable tools and analogue devices Measurement category III corresponds to measurements on building installations. Example: measurement on distribution panels, cabling, etc. Measurement category IV corresponds to measurements taken at the source of low-voltage installations Example: metering and measurements on overvoltage protection devices. Phase Rotation Meter Model 6608 3

1.3 Receiving Your Shipment Upon receiving your shipment, make sure that the contents are consistent with the packing list. Notify your distributor of any missing items. If the equipment appears to be damaged, file a claim immediately with the carrier and notify your distributor at once, giving a detailed description of any damage. Save the damaged packing container to substantiate your claim. 1.4 Ordering Information Phase Rotation Meter Model 6608... Cat. #2121.10 Includes meter, three color-coded test leads (red, black, blue), three alligator clips (black), soft carrying case and a user manual. 1.4.1 Accessories and Replacement Parts Soft carrying case... Cat. #2121.54 Set of 3 color-coded leads with black alligator clips CAT III 1000V 10A... Cat. #2121.55 4 Phase Rotation Meter Model 6608

CHAPTER 2 PRODUCT FEATURES 2.1 Description The Model 6608 is designed to facilitate installing three-phase electrical power supply networks by allowing a rapid determination of the direction of phase rotation 2.2 Control Features 1 2 L1/A L2/B L3/C 690V 600V CAT III 300V CAT IV L1L2L3 1. Test lead input terminals 2. Phase indicators L1, L2, L3 3. Clockwise and counterclockwise rotation LED 3 L R PHASE ROTATION MODEL 6608 Phase Rotation Meter Model 6608 5

CHAPTER 3 SPECIFICATIONS ELECTRICAL Operating Voltage Frequency Test Current Power Source MECHANICAL Dimensions Weight ENVIRONMENTAL Operating Temperature Storage Temperature SAFETY Safety Rating Double Insulation CE Mark 40 to 850Vac between phases 15 to 400Hz 1mA Line Powered 5.1 x 2.7 x 1.3" (130 x 69 x 32mm) 4.5 oz (130g) 32 to 104 F (0 to 40 C) -4 to 122 F (-20 to 50 C); RH < 80% CAT III 600V IEC 61010-1, DIN VDE 0411; IEC 61557-7, DIN VDE 0413-7; Tightness : IP 40 (as per IEC 60529 Ed.92) Yes Yes 6 Phase Rotation Meter Model 6608

CHAPTER 4 OPERATION 4.1 Phase Rotation Direction On a three-phase electrical network: 1. Connect the three leads to the instrument, matching the markings. 2. Connect the three alligator clips to the 3 phases of the network to be tested. 3. The display lights up, indicating that the instrument is in operation. 4. When the three phase indicators (L1, L2, L3) are lit, the clockwise (or counter-clockwise) rotation arrow indicates the direction of phase rotation. Warning: The wrong direction of rotation may be displayed if a lead is connected in error to the neutral conductor. Refer to the instrument s back label for a summary of the various display possibilities. Phase Rotation Meter Model 6608 7

CHAPTER 5 MAINTENANCE 5.1 Cleaning To avoid electrical shock or damage to the meter, do not get water inside the case. Periodically wipe the case with a damp cloth and mild detergent Dry completely before using again. Do not use abrasives or solvents. 8 Phase Rotation Meter Model 6608

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 03/17 99-MAN 100336 v4 Chauvin Arnoux, Inc. d.b.a. AEMC Instruments