IECEx Certificate. INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

Similar documents
IECEx Certificate of Conform ity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

Certificate No.: lecex BVS X issue No.:1 Certificate history: Issue No. 1 ( ) Status:

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity


IECEx Certificate of Conformity

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

IECEx Certificate of Conformity

srra, of Conformity IECEx Gert f cate ?-ot,b

IECEx Certificate of Conformity

Report No EC. 1 Windsor Dials, Windsor, Berkshire, UK. SL4 1RS ATEX CERTIFICATION REPORT. Electronstandart-pribor

Certification Supplement Manual

Ex-d luminaire type dklk 23 (V-CG-S) GHG W. Flameproof enclosure 'd', Equipment dust ignition protection by enclosure 't' Dr. F.

SmartPower Solutions [ SmartPower Solutions. Quick Installation Guide , Rev AC January 2012

Flameproof Manual Call Points Series MCP

IECEx Certificate of Conformity

INTERNATIONAL ELECTROTECHNICAL COMMISSlON IEC Certification Scheme for Explosive Atmospheres

805QS Pressure Switch-Transmitter

Approvals, Certificates and Conditions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

INSTRUCTION MANUAL (ATEX / IECEx)

Dräger Polytron 5700 IR Detection of flammable gases and vapours

IECEx Certificate of Conformity

DB5 Intrinsically Safe Sounder Type DB-5

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

User s Manual YTA610 and YTA710 NEPSI Certification

SmartPower Solutions. Quick Start Guide , Rev CA March 2015

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

FINAL ATEX REPORT ON EQUIPMENT FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES FOR GOLDEN PROMISE EQUIPMENT INC. FLOW MONITOR, GPE3000 SERIES,

Rosemount 2051G Pressure Transmitter

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

Quick Start Guide , Rev EA December Rosemount 0065/0185 Sensor Assembly

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Rosemount 702 Wireless Discrete Transmitter

Certificate of Compliance

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Flameproof Manual Call Points Series MCP

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Certificate of Compliance

Rosemount 644 Temperature Transmitter

Dräger Polytron 8700 IR Detection of flammable gases and vapors

OPTIBAR DP 7060 Supplementary Instructions

FLASHLIGHT ANSI STANDARDS

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

IR1xxx Series 1, IR2xxx Series 1 Miniature Infrared Gas Sensors for Hazardous Areas and Intrinsic Safety in Mining

slra IEC of Gonformity IECEx Cert f cate ü* t4

Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev DC August 2017

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Flameproof Manual Call Points

UL HAZARDOUS LOCATIONS SERVICES

Explosion Proof Manual Call Points Series MCP

Fixed Gas Detection System/Meridian CERTIFICATION

Rosemount 248 Temperature Transmitter. Quick Start Guide , Rev. EA April 2013

Intrinsically Safe Solutions

IR15 Dual Gas Series Datasheet

14300 MAINS SEPARATOR ALARM MANUAL

Installationsmanual GWSL1100/2100, GWML3100

Earth-Rite II PLUS Static Earthing System

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Documentation. Explosion-Protection. for Smoke Detection Panels SDS-4, SDS-8, SDS-12 and Extension Panels SDS-E8, SDS-E12, SDS-E16, SDS-EC16

Dräger Polytron 8100 EC Detection of toxic gases and vapors

OPTIWAVE X500 Supplementary Instructions

Rosemount 2088, 2090P, and 2090F Pressure Transmitters

Dräger Polytron 8720 IR Detection of carbon dioxide

Annubar Flowmeter Series

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Explosion-proof Immersion Heater Type D-8660

IR25 Dual Gas Series Datasheet

VERSAFLOW VORTEX Supplementary instructions

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Quick Start Guide For the

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Survey of electrical equipment installed in hazardous areas on tankers

Transcription:

INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Status: Current Issue NO.7 () Issue NO.6 (2014-08-06) Page 1 of 5 Issue NO.5 (2013-04-26) Issue NO.4 (2012-05-03) Applicant: CrO'NCOn Detection Instruments Umited 172 Brook Drive Milton Park Abingdon Issue NO.3 (2012-01-10) Issue NO.2 (2011-09-30) Issue NO.1 (2010-10-27) Issue No. 0 (2010-04-29) Oxfordshire OX144SD Equipment: IR Gas Detector with Display Opuonalaccessory: Type of Protection: Flameproof &Intrinsic Safety Marking: Ex db ia lie T4 Gb (-40 C :5i Ta :5i +75 C) - All variants Extb ia mc T135 C Db (-40 C :5i Ta :5i +40 C) - Remote &Handheld Display Models only Approved for issue on behalfofthe IECEx Certification Body: R.S. Sinclair Position: Technical Manager Signature: (for printed version) Date: 1. This certificate and schedule may only be reproduced in full. 2. This certificate is not transferable and remains the property of the issuing body. 3. The Status and authenticity of this certificate may be verified by visiting the OfficiallECEx Website. Certificate issued by: SGS Baseefa Urnited Rockhead Business Park staden Lane Buxton, Derbyshire, SK17 9RZ

Page 2 of 5 Manufacturer: Crowc:on Detection Instruments Limited 172 Brook Drive Milton Park Abingdon Oxfordshire OX144SD Additional Manufacturing location(s): This certificate is issued as verification that a sample(s), representative of production, was assessed and tested and found to comply with the IEC Standard list below and that the manufacturer's quality system, relating to the Ex products covered by this certificate, was assessed and found to comply with the IECEx Quality system requirements. This certificate is granted subject to the conditions as set out in IECEx Scheme Rules, IECEx 02 and Operational Documents as amended. STANDARDS: The apparatus and any acceptable variations to it specified in the schedule of this certificate and the identified documents, was found to comply with the following standards: IEC 60079-0 : 2011 Edition:6.0 IEC 60079-1 : 2014-06 Edition:7.0 IEC 60079-11 : 2011 Edition:6.0 IEC 60079-31 : 2013 Edition:2 Explosive atmospheres - Part 0: General requirements Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures lid" Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i" Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure lit" This Certificate does not indicate compliance with electrical safety and performance requirements other than those expressly included in the Standards listed above. TEST &ASSESSMENT REPORTS: A sample(s) of the equipment listed has successfully met the examination and test requirements as recorded in Test Report: GB/BAS/ExTR09.0146/00 GB/BAS/ExTR10.0243/00 GB/BAS/ExTR12.0063/00 Quality Assessment Report: GB/BAS/QAR06.0070/07 GB/BAS/ExTR09.0155/00 GB/BAS/ExTR11.0210/00 GB/BAS/ExTR13.0064/00 GB/BAS/ExTR10.0231/00 GB/BAS/ExTR11.0309/00 GB/BAS/ExTR17.0131/00

Schedule Page 3 of 5 EQUIPMENT: Equipment and systems covered by this certificate are as follows: The IR Gas Detector with Display comprises a stainless steel housing with a transparent sapphire detector window fitted to the end and clamped in place. A protective weatherproof cover manufactured in an antistatic plastic material is fitted over the sapphire window. The housing contains optics and a stacked PCB assembly. At the opposite end to the window is an IS Interface assembly. The IS Interface, on two encapsulated PCB's, provides an intrinsically safe output to power the display which contains one more PCB. The display may be directly mounted on the gas detector or remotely mounted using up to 30 metres of cable which is fitted with connectors at each end. The connection arrangement and the enclosures protect the intrinsically safe circuits to at least IP20. The interface assembly is secured against unintentional removal from the main gas detector by a securing plate fixed in position by cap screws with an internal hexagon head. The internal circuits of the IR Gas Detector are rated up to a maximum of 32V and 5W, of which less than 0.7W is present at the display. A Handheld Display is also available and is designed for connection to the IR Gas Detector only while the equipment is being calibrated. Once calibration is complete the Handheld Display is removed. The display is fitted with a 1.5 metre cable with a UR ratio not exceeding 23j.JH/O. In cases where the IR Gas Detector is installed in a location where it is difficult to connect the handheld display to it, a Remote Calibration Box can be connected to the detector. The Remote Calibration Box comprises a black polyester enclosure fitted with two inter-connected polarised connectors permitting connection to the Gas Detector via a cable of up to 28.5 metres and a UR ratio not exceeding 23j.JH/O and the Handheld Display. All variants of the IR Gas Detector with Display are suitable for installation in an explosive gas atmosphere, but the Remote and Handheld Display variants of the equipment can be additionally installed in an explosive dust atmosphere with the Gas Detector and I.S interface, and where applicable the Remote Calibration Box, mounted in the hazardous area and the remote or Handheld Display mounted in the nonhazardous area. Based on this, the following variants of the IR Gas Detector with Display are marked as follows - IR Gas Detector with Fixed Display Ex db ia IIC T4 Gb (-40 C S T as +75 C) IR Gas Detector with Remote or Handheld Display Ex db ia IIC T4 Gb (-40 C S T as +75 C) Ex tb ia IIIC T135 C Db (-40 C S T a S +40 C) For the Ex db I Ex tb part (Main Gas Detector) Two cable entry holes are provided as specified on the certified drawings for the accommodation of a flameproof cable entry device, with or without the interposition of a flameproof thread adapter. One cable entry is of thread form M20, and the other is of thread form %" NPT. The cable entry thread form for each cable entry is identified on the body of the IR Gas Detector by etched markings. The cable entry device and thread adapter shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a component) under an EU Type Examination Certificate to Directive 2014/34/EU. Any unused cable entry holes must be fitted with a suitable flameproof stopping plug certified as Equipment (not a component) under an EU Type Examination Certificate to Directive 2014/34/EU. When the Remote and Handheld variants are mounted in an explosive dust atmosphere, cable entry device and thread adapter shall be suitable for the equipment, the cable and the conditions of use and shall be certified as Equipment (not a component) under an EU Type Examination Certificate to Directive 2014/34/EU with a minimum ingress protection of at least IP6x. For the Ex i part (IS Interface & Display The LlR ratio of the interconnecting cable for the Remote & Handheld Display must not exceed 23j.JH/O. Two contacts on the front of the display are intended for connection to a HART communicator, Emerson Type 375 Communicator to Certificate BVS 03 ATEX E 347 & IECEx BVS 08.0044 or equivalent. The output parameters for these contacts are U 0 = 5.9V, 1 0 = 19mA, P o =28mW, C i =0 and L i =O. The contacts on the front of the display are not protected to IP20, however the possible output has a FOS of at least 250 so does not pose a hazard.

IECEx BAS 09.01 04X Page 4 of 5 SPECIFIC CONDITIONS OF USE: YES as shown below: 1. The equipment must be earthed using the cable gland and steel armoured cable 2.1R Gas Detectors with Remote & Hand Held Displays Only: When located in an explosive dust atmosphere, the display must only be mounted in the non-hazardous area.

IECEx BAS 09.01 04X Page 5 of 5 DETAILS OF CERTIFICATE CHANGES (for issues 1 and above): Variation 7.1 To confirm the current designs of the IR Gas Detector with Display have been reviewed against the requirements of IEC 60079-0: 2011 Ed. 6, IEC 60079-1: 2014 Ed. 7 & IEC 60079-11: 2011 Ed. 6 in respect of the differences from IEC 60079-0: 2007 Ed. 5, IEC 60079-1: 2007 Ed. 6 & IEC 60079-11: 2006 Ed. 5 and, with exception of the markings, none of the differences affect the equipment. In accordance with the marking requirements of the new editions of the standards, all variants of the equipment are now marked: - Ex db ia IIC T4 Gb (-40 C S Ta S +75 C) Variation 7.2 To permit the assessment of the remote display variants of the IR Gas Detector fitted with the IS Barrier against the dust requirements of IEC 60079-0: 2011 IEC 60079-11: 2011 and IEC 60079-31: 2013 permitting the mounting of this assembly in the explosive dust atmosphere with the remote display only mounted in the non-hazardous area. This variants of equipment is additionally marked with the following dust Certification Code: - The certificate schedule was revised to detail the dust certification and a Specific Condition of Use was added to the certificate specifying the display must only be mounted in the non-hazardous area. Variation 7.3 To permit minor drawing changes not affecting the original assessment. ExTR: GBlBASIExTR17.0131/00 File Reference: 15/0089