Product Information as required by EU regulations No 811/2013 and No 813/2013

Similar documents
Product fiche concerning the COMMISSION DELEGATED REGULATIONS

Product fiche concerning the COMMISSION DELEGATED REGULATIONS

COMMISSION REGULATION (EU) No /.. of XXX

WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)

Installer manual ELK 213 Immersion heater

Draft COMMUNICATION FROM THE COMMISSION

WALL HUNG GAS BOILER FOR C.H. AND PREDISPOSTION FOR INSTANTANEOUS D.H.W. PRODUCTION (with optional kit) MODELS 34,8 kw (depotenziata) 50 C

PART I ENERGY EFFICIENCY ACQUIS / DELEGATED REGULATION (EU) 811/2013

Official Journal of the European Union L 239/1. (Non-legislative acts) REGULATIONS

ANNEXES TO WORKING DOCUMENT ON POSSIBLE ECODESIGN AND ENERGY LABELLING REQUIREMENTS FOR SOLID FUEL BOILERS (< 500 KW)

White paper: New Ecodesign rules and energy labelling for space and water heaters

VIADRUS K4 Manual for boiler operation and installation

Grant Vortex Pro Boiler House Range 26/36, 36/46, 46/58 and 58/70

ANNEXES. to the. COMMISSION REGULATION (EU) No /..

User manual and Installation instructions

VERY LOW TEMPERATURE CONDENSING UNIT Low NOx Class 5 MODELS SEASONAL EFFICIENCY A A A A A A A

2. SCOPE. OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p OJ L 239, , p. 162.

MYdens T 5WARRANTY 1:20. Ti TITANIUM. commercial gas condensing boilers. boilers from 60 to 280 kw AISI 316 YEARS WORKING PRESSURE HEAT EXCHANGER

OJ L 239, , p. 1. OJ L 239, , p. 83, OJ L 239, , p. 136.

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

white blue cobalt bordeaux light oak (rovere)

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

DESIGN & TECHNICAL MANUAL

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

DTG130-45/65/90/115 Eco.NOx Plus

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Solar thermal solutions within the Energy Labelling Context

THE PERFECT CONDENSATION

Technology marries design. The boiler finally becomes a piece of design, emerging as a protagonist in a new domestic environment.

Easi-Heat Plus S. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions

COMMISSION REGULATION (EU) No /.. of XXX

(Non-legislative acts) REGULATIONS

Labelling of Gas boilers

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Installation and Service Manual Combi. Condensing Combination Boiler

A Step by Step Guide to Energy Labelling of Gaseous Fuel Local Space Heaters (Part 1)

Information on the Platform HEIZUNGSlabel. Contents

Installer manual ELK 213 Immersion heater

INSTALLATION AND OPERATING INSTRUCTIONS EVOLUTION EV HFM

Copper-Fin GAS-FIRED WATER HEATERS

Compact A. High efficiency combi boiler. Users Instructions. Installation & Servicing Instructions

PRIWA & PRIWA PLUS ENERWA & ENERWA PLUS CONDENSING COMBI BOILERS INSTALLATION, USER & SERVICE MANUAL

AS10S-DPNHE. Rating(s)... : V 3N~; 50Hz; other rating refer to page 6. Guangzhou Hiseer Air conditioning Co,. LTD

Page 2 of 42 Test report no. HS Rev.00

(Text with EEA relevance)

WHAT TO DO IF YOU SMELL GAS

SGE Condensing Gas - Solar Water Heater

Model and/or type reference... : COPMAX GS 15 JORDVARMEPUMPE Rating(s)... : V 3N~; 50Hz; other rating refer to page 6

Teknik Data NIBE F2120 8, 12, 16, 20

Electronic pellet burner controller - NPBC-V3M. Electronic Pellet Burner Controller NPBC-V3M

Tower Green HE Hybrid

Installation and Service Manual. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Compact HRE Boiler Range. The smart choice for heating and hot water

User s Information Manual

Installation and Service Manual. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

PICTOR CONDENSING KR 55 - KR 85

Installation & Operation Manual

AGUAdensT TM 100% commercial condensing D.H.W. commercial water heaters from 70 to 280 kw AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

103776HV1241 NOVELAN LAV 8-HV kw kw db 50 db

Installation and Service Manual. Titanium Combi Condensing Combination Boiler

The iqe Boiler Range. Combination and System T Boilers.

Installation and Service Manual. Promax Combi Condensing Combination Boiler

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

evolve High efficiency combi boiler Users Instructions Installation & Servicing Instructions

User Guide. Platinum Combi Gas Fired Wall Mounted Condensing Combination Boiler

Planner Documentation R600 EVO

PCH/new Series. High performance, total flexibility

Boiler Technical Specifications (2013)

Andrews Water Heaters

MONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

GAS FIRED ATMOSPHERIC ELECTRONIC VERSION kw

EU GPP Criteria for Water-based Heaters

Installation and Service Manual. Heat Condensing Central Heating Boiler

Compact HRE and ECO RF Boiler Range. The smart choice for heating and hot water

User Guide. Promax SL Condensing Central Heating Boiler

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

REPORT. Condensing air heaters. Technology evaluation. Project report Maj 2013

Ciao Green Condensing Wall-Hung Boilers

MODULAR GAS CONDENSING UNIT EQUIPPED WITH PRIMARY RING and premix modulating Low NO x. from 100 to 900 kw and in battery up to 8 units

ENTE CERTIFICAZIONE MACCHINE

Ecodesign for Energy Related products. State of play ASERCOM/EPEE SYMPOSIUM E. Baert-

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

gas condensing combi boiler

CITY PLUS. Wall-hung condensing boilers. ErP 24 HE 30 HE. Ready

Hot Water Generation for Commercial and Industrial Applications. Paul Marsden Specification Sales Manager

Installation and Service Manual. Promax SL Condensing Central Heating Boiler

COMMISSION DELEGATED REGULATION (EU) No /.. of XXX

COMPACT HRE ECO RF COMPACT HRE & ECO RF SMART CHOICE FOR HEATING AND HOT WATER

User Guide. Gold Combi Condensing Combination Boiler

User Guide Combi. Condensing Combination Boiler

Installation, Maintenance and User Guide

Greenstar CDi Compact ErP

Installation & Operation Manual

The products covered by the Regulation can be classified as follows:

MONOBLOCK HEAVY OIL BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

1. Purpose of the guidelines and disclaimer

Eligibility criteria

SECTION 1: USE AND MAINTENANCE

Transcription:

Product Information as required by EU regulations 811/2013 and 813/2013 Rev : 1.0 Product Fiche (according to EU regulation 811/2013) (a) Supplier s name or trademark E.C.A. (b) Supplier s model identifier Confeo Premix CP S 30 kw HM-P (c) Space heating: medium temperature application Water heating: declared load profile XL (d) Seasonal space heating energy efficiency class A Water heating energy efficiency class A (e) Rated heat output, including the rated heat output of any supplementary heater 27,0 kw (f) Space heating: annual energy consumption 23490 kwh and/ or 84 GJ Water heating: annual electricity and/ or fuel consumption 62 kwh and/ or 18 GJ (g) Seasonal space heating energy efficiency 92,0 Water heating energy efficiency 90,0 (h) Sound power level, indoors 53 db(a) (i) Combination heater is able to work only during off-peak hours no (j) Specific precautions for assembly, installation and maintenance All specific precautions for installation, assembly and maintanence are described in the installation and service manual. Date: Mar 30, 2018 Contents may be subject to change Page 1 / 2

Product Information Requirements (according to EU regulation 813/2013) Model condensing boiler low temperature boiler** B1 boiler Confeo Premix CP S 30 kw HM-P Cogeneration space heater If yes, equipped with a supplementary heater Combination heater Item Symbol Value Unit Item Symbol Value Unit Seasonal space heating ɳs Rated heat output Prated 27,0 kw 92,0 energy efficiency For boiler space heaters and boiler combination heaters: Useful heat output high-temperature regime (*) P 4 At 30 of rated heat output and low-temperature regime P 1 (**) For boiler space heaters and boiler combination heaters: Useful efficiency 27,3 kw high-temperature regime (*) ɳ 4 87,7 At 30 of rated heat output and low-temperature regime ɳ 1 9 kw (**) 97,8 Supplementary heater Rated heat output P sup 0 kw Type of energy input no value Auxiliary electricity consumption At full load elmax Other items 0,054 kw Standby heat loss P stby 0,065 kw At part load elmin 0,022 kw Ignition burner power consumption P ign 0 kw In standby mode P SB 0,005 kw Emission of Nitrogen Oxides x 42,80 mg/kwh For combination heaters: Declared load profile XL Water heating energy efficiency ɳ wh 90,0 Daily electricity consumption Q elec 0,283 kwh Daily fuel consumption Q fuel 23,108 kwh Contact details Emas Makina Sanayi A.Ş. - Organize Sanayi Bölgesi III. Kısım Mustafa Kemal Bulvarı :13 MANİSA 45030 (*) High-temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. (**) Low-temperature means for condensing boilers 30 C, for low-temperature boilers 37 C and for other heaters 50 C return temperature (at heater inlet). Specific precautions that shall be taken when the space heater is assembled, installed or maintained/ information relevant for disassembly, recycling and/or disposal at end-of-life All specific precautions for assembly, installation and maintenance and information relevant for dissassembly, recycling and/or disposal at end-of-life are described in the operating and installation instructions. Read and follow the operating and installation instructions. For type B1 boiler and type B1 combination boiler: This natural draught boiler is intended to be connected only to a flue shared between multiple dwellings in existing buildings that evacuates the residues of combustion to the outside of the room containing the boiler. It draws the combustion air directly from the room and incorporates a draught diverter. Due to lower efficiency, any other use of this boiler shall be avoided and would result in higher energy consumption and higher operating costs. Date: Mar 30, 2018 Contents may be subject to change Page 2 / 2

Product Information as required by EU regulations 811/2013 and 813/2013 Rev : 1.0 Product Fiche (according to EU regulation 811/2013) (a) Supplier s name or trademark E.C.A. (b) Supplier s model identifier Confeo Premix CP S 35 kw HM-P (c) Space heating: medium temperature application Water heating: declared load profile XL (d) Seasonal space heating energy efficiency class A Water heating energy efficiency class A (e) Rated heat output, including the rated heat output of any supplementary heater 32,0 kw (f) Space heating: annual energy consumption 27840 kwh and/ or 100 GJ Water heating: annual electricity and/ or fuel consumption 62 kwh and/ or 18 GJ (g) Seasonal space heating energy efficiency 92,0 Water heating energy efficiency 90,0 (h) Sound power level, indoors 53 db(a) (i) Combination heater is able to work only during off-peak hours no (j) Specific precautions for assembly, installation and maintenance All specific precautions for installation, assembly and maintanence are described in the installation and service manual. Date: Mar 30, 2018 Contents may be subject to change Page 1 / 2

Product Information Requirements (according to EU regulation 813/2013) Model condensing boiler low temperature boiler** B1 boiler Confeo Premix CP S 35 kw HM-P Cogeneration space heater If yes, equipped with a supplementary heater Combination heater Item Symbol Value Unit Item Symbol Value Unit Seasonal space heating ɳs Rated heat output Prated 32,0 kw 92,0 energy efficiency For boiler space heaters and boiler combination heaters: Useful heat output high-temperature regime (*) P 4 At 30 of rated heat output and low-temperature regime P 1 (**) For boiler space heaters and boiler combination heaters: Useful efficiency 32,3 kw high-temperature regime (*) ɳ 4 87,7 At 30 of rated heat output and low-temperature regime ɳ 1 10,7 kw (**) 97,8 Supplementary heater Rated heat output P sup 0 kw Type of energy input no value Auxiliary electricity consumption At full load elmax Other items 0,054 kw Standby heat loss P stby 0,065 kw At part load elmin 0,022 kw Ignition burner power consumption P ign 0 kw In standby mode P SB 0,005 kw Emission of Nitrogen Oxides x 42,80 mg/kwh For combination heaters: Declared load profile XL Water heating energy efficiency ɳ wh 90,0 Daily electricity consumption Q elec 0,283 kwh Daily fuel consumption Q fuel 23,108 kwh Contact details Emas Makina Sanayi A.Ş. - Organize Sanayi Bölgesi III. Kısım Mustafa Kemal Bulvarı :13 MANİSA 45030 (*) High-temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. (**) Low-temperature means for condensing boilers 30 C, for low-temperature boilers 37 C and for other heaters 50 C return temperature (at heater inlet). Specific precautions that shall be taken when the space heater is assembled, installed or maintained/ information relevant for disassembly, recycling and/or disposal at end-of-life All specific precautions for assembly, installation and maintenance and information relevant for dissassembly, recycling and/or disposal at end-of-life are described in the operating and installation instructions. Read and follow the operating and installation instructions. For type B1 boiler and type B1 combination boiler: This natural draught boiler is intended to be connected only to a flue shared between multiple dwellings in existing buildings that evacuates the residues of combustion to the outside of the room containing the boiler. It draws the combustion air directly from the room and incorporates a draught diverter. Due to lower efficiency, any other use of this boiler shall be avoided and would result in higher energy consumption and higher operating costs. Date: Mar 30, 2018 Contents may be subject to change Page 2 / 2

Product Information as required by EU regulations 811/2013 and 813/2013 Rev : 1.0 Product Fiche (according to EU regulation 811/2013) (a) Supplier s name or trademark E.C.A. (b) Supplier s model identifier Confeo Premix CP S 30 kw HCH-P (c) Space heating: medium temperature application (d) Seasonal space heating energy efficiency class A (e) Rated heat output, including the rated heat output of any supplementary heater 27,0 kw (f) Space heating: annual energy consumption 23490 kwh and/ or 84 GJ (g) Seasonal space heating energy efficiency 92 (h) Sound power level, indoors 53 db(a) (i) Combination heater is able to work only during off-peak hours no (j) Specific precautions for assembly, installation and maintenance All specific precautions for installation, assembly and maintanence are described in the installation and service manual. Date: Mar 30, 2018 Contents may be subject to change Page 1 / 2

Product Information Requirements (according to EU regulation 813/2013) Model condensing boiler low temperature boiler** B1 boiler Confeo Premix CP S 30 kw HCH-P Cogeneration space heater If yes, equipped with a supplementary heater Combination heater Item Symbol Value Unit Item Symbol Value Unit Rated heat output Prated 27,0 kw Seasonal space heating ɳs energy efficiency 92,0 For boiler space heaters and boiler combination heaters: Useful heat For boiler space heaters and boiler combination heaters: Useful efficiency output high-temperature regime (*) P 4 At 30 of rated heat output and low-temperature regime P 1 (**) 27,3 kw high-temperature regime (*) ɳ 4 87,7 At 30 of rated heat output and low-temperature regime ɳ 1 9 kw (**) 97,8 Supplementary heater Rated heat output P sup 0 kw Type of energy input no value Auxiliary electricity consumption At full load elmax Other items 0,054 kw Standby heat loss P stby 0,065 kw At part load elmin 0,022 kw Ignition burner power consumption P ign 0 kw In standby mode P SB 0,005 kw Emission of Nitrogen Oxides x 42,80 mg/kwh Contact details Emas Makina Sanayi A.Ş. - Organize Sanayi Bölgesi III. Kısım Mustafa Kemal Bulvarı :13 MANİSA 45030 (*) High-temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. (**) Low-temperature means for condensing boilers 30 C, for low-temperature boilers 37 C and for other heaters 50 C return temperature (at heater inlet). Specific precautions that shall be taken when the space heater is assembled, installed or maintained/ information relevant for disassembly, recycling and/or disposal at end-of-life All specific precautions for assembly, installation and maintenance and information relevant for dissassembly, recycling and/or disposal at end-of-life are described in the operating and installation instructions. Read and follow the operating and installation instructions. For type B1 boiler and type B1 combination boiler: This natural draught boiler is intended to be connected only to a flue shared between multiple dwellings in existing buildings that evacuates the residues of combustion to the outside of the room containing the boiler. It draws the combustion air directly from the room and incorporates a draught diverter. Due to lower efficiency, any other use of this boiler shall be avoided and would result in higher energy consumption and higher operating costs. Date: Mar 30, 2018 Contents may be subject to change Page 2 / 2

Product Information as required by EU regulations 811/2013 and 813/2013 Rev : 1.0 Product Fiche (according to EU regulation 811/2013) (a) Supplier s name or trademark E.C.A. (b) Supplier s model identifier Confeo Premix CP S 30 kw HST-P (c) Space heating: medium temperature application (d) Seasonal space heating energy efficiency class A (e) Rated heat output, including the rated heat output of any supplementary heater 27,0 kw (f) Space heating: annual energy consumption 23490 kwh and/ or 84 GJ (g) Seasonal space heating energy efficiency 92 (h) Sound power level, indoors 53 db(a) (i) Combination heater is able to work only during off-peak hours no (j) Specific precautions for assembly, installation and maintenance All specific precautions for installation, assembly and maintanence are described in the installation and service manual. Date: Mar 30, 2018 Contents may be subject to change Page 1 / 2

Product Information Requirements (according to EU regulation 813/2013) Model condensing boiler low temperature boiler** B1 boiler Confeo Premix CP S 30 kw HST-P Cogeneration space heater If yes, equipped with a supplementary heater Combination heater Item Symbol Value Unit Item Symbol Value Unit Rated heat output Prated 27,0 kw Seasonal space heating ɳs energy efficiency 92,0 For boiler space heaters and boiler combination heaters: Useful heat For boiler space heaters and boiler combination heaters: Useful efficiency output high-temperature regime (*) P 4 At 30 of rated heat output and low-temperature regime P 1 (**) 27,3 kw high-temperature regime (*) ɳ 4 87,7 At 30 of rated heat output and low-temperature regime ɳ 1 9 kw (**) 97,8 Supplementary heater Rated heat output P sup 0 kw Type of energy input no value Auxiliary electricity consumption At full load elmax Other items 0,054 kw Standby heat loss P stby 0,065 kw At part load elmin 0,022 kw Ignition burner power consumption P ign 0 kw In standby mode P SB 0,005 kw Emission of Nitrogen Oxides x 42,80 mg/kwh Contact details Emas Makina Sanayi A.Ş. - Organize Sanayi Bölgesi III. Kısım Mustafa Kemal Bulvarı :13 MANİSA 45030 (*) High-temperature regime means 60 C return temperature at heater inlet and 80 C feed temperature at heater outlet. (**) Low-temperature means for condensing boilers 30 C, for low-temperature boilers 37 C and for other heaters 50 C return temperature (at heater inlet). Specific precautions that shall be taken when the space heater is assembled, installed or maintained/ information relevant for disassembly, recycling and/or disposal at end-of-life All specific precautions for assembly, installation and maintenance and information relevant for dissassembly, recycling and/or disposal at end-of-life are described in the operating and installation instructions. Read and follow the operating and installation instructions. For type B1 boiler and type B1 combination boiler: This natural draught boiler is intended to be connected only to a flue shared between multiple dwellings in existing buildings that evacuates the residues of combustion to the outside of the room containing the boiler. It draws the combustion air directly from the room and incorporates a draught diverter. Due to lower efficiency, any other use of this boiler shall be avoided and would result in higher energy consumption and higher operating costs. Date: Mar 30, 2018 Contents may be subject to change Page 2 / 2