COMMISSION DELEGATED REGULATION (EU) /... of XXX

Co170 ARMOURED WALL BURGLAR PROOF GRADE 2 ACCORDING TO UNI EN1143

Updated 04/07/2017 Page 1/8

Initial Test Typing Leak test

Measurement of force - UNI EN 12453(2002) point 5. C % U.R. Slow-down speed: Opening slow-down torque: Closing slow-down torque: 33,0 28,0

BUILDING CATALOGUE

Tubular motor with encoder for awnings series EUROPLUS


Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FURNISHINGS FOR WINDOWS OR DOORS (concerned with the functioning of the door or window E05; roller blinds E06B)

CESI EXTENSION D. 02/12 ~ FGH ~ to EC-Type Examination Certificate CESI 03A TEX057X Equipment: Explosion proofsolenoid series OA-; OZA; MZA-A- Manufac

DIVISION FURNISHINGS. WINDOW TREATMENTS Page 63 of WINDOW TREATMENTS WINDOW BLINDS

oem OEM 1" Between the Glass Metal Blind Series P2100 Included:

Measurement of force - UNI EN 12453(2002) point 5 30,0 33,0

Industrial 3721/3741/3745/3791. Documented Quality - Stitch by Stitch

TEST REPORT FIRES-FR AUNE

DECLARATION OF CONFORMITY FOR THE MEDICAL DEVICE FAMILY LOW-PRESSURE HOSE ASSEMBLIES FOR USE WITH MEDICAL GASES

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

IMPORTANT NOTICE BUILDERS AND CONTRACTORS WORKING IN NORTH RICHLAND HILLS, TEXAS. June 17th, 2016

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Fiji Electricity Authority Transmission Unit 2 Marlow Street, Suva

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

PERFORMANCE TEST REPORT. Rendered to: EVERBLOCK SYSTEMS, LLC. PRODUCT: Modular Block Product

Pleated blinds, free hanging units FS, FK, FE Description

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

INSTALLATION AND OPERATION MANUAL

Classification Report Reaction to fire of building elements DIN EN :2007. Class E

Contact person Date Reference Page Christian Larsson P01958A 1 (3) Safety

Trade Practices (Consumer Product Safety Standard Corded Internal Window Coverings) Regulations

Window Treatment Solutions

Technical Assessment Guideline Applicable for the Kiwa KQ Certification Scheme:

General information BB0113

C 32 ELECTRIC HEATED DISPLAY FOR PIZZA C 32 INSTRUCTIONS FOR INSTALLATION USE AND MAINTENANCE

TEST REPORT. Fire tests of construction products in compliance with the following standard:

This document is a preview generated by EVS

Co153, Co154 SECURITY SHUTTERS RC3 GRADE ANTI-BURGLARY CERTIFICATION UNI EN1627 P6B GRADE ANTI-BURGLARY CERTIFICATION UNI EN356

BLUE GALAXY DEPYROGENATION TUNNELS. Solid Dose Sol

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Child Safety Guide SAFETY FIRST. STYLE SECOND TO NONE.

Made to Measure Window Furnishings

Custom Window Treatments. Child Safety Guide SAFETY FIRST. STYLE SECOND TO NONE.

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

This annex is valid from: to Replaces annex dated: Locations where activities are performed under accreditation

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

CREATIVE ITALIAN SOFAS & BEDS

Special Provision No. 683S28 December 2017

CREATIVE ITALIAN SOFAS & BEDS

REACTION TO FIRE CLASSIFICATION REPORT No. RA ACCORDING TO THE EUROPEAN STANDARD NF EN A1:2013

Product Range. The UK s leading trade only Window Blind manufacturer

Temperature-Relay TR210

NERGYTOWER. energytower Leader in style, quality and safety. ground distribution turrets

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

INTERNATIONAL STANDARD

AIR CONDITIONING AIR DOOR RANGE NEW

Title: WF Assessment Report No B. Prepared for: CHEMOLLI S.A.S. di Eros Chemolli & C. Via Fitta, Arco (TN), Italy

Physical-mechanical properties*

Online Ordering. Swale Blinds has established itself as one of the UK s leading trade only Window Blind suppliers and installers.

INTERNATIONAL STANDARD

External venetian blinds

Weigh In Motion (WIM) Wheel Impact Load Detector (WILD)

SPECIFICATION SECTION:

Twist Roller Blinds. Distinctive ambiance and privacy control in one

This document is a preview generated by EVS

FIGURE 1. Model RD107

ENG 2013_00. Guidelines for the Visual Quality Evaluation of Venetian Blinds Inside Insulating Glass Units. Venetian Blinds Division is a brand of

Most veratile range of perfect fit window roller, Venetian, pleated & bespoke blinds

AS/NZS :2003 Luminaires - Part 1: General requirements and tests

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

THE WIDTH AND HEIGHT OF THE LIGHT HOLE IN THE WINDOW WING IS MEASURED IN THE FOLLOWING WAY:

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

PLEASE READ PRODUCT GUIDE NOTE IN FULL BEFORE COMPLETING ORDER FORM, 1 BLIND PER ORDER FORM, STATE QUANTITY IN BOX PROVIDED BELOW

ISO INTERNATIONAL STANDARD. Oscillation-type density meters Part 1: Laboratory instruments

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

AS/NZS :2009. Performance of household electrical appliances Refrigerating appliances AS/NZS :2009

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

HEDMAN The HEDMAN Company 189 Gordon St. Elk Grove Village, IL

DRYTEK 1 - User Manual ELECTRICAL PANEL FOR 1 MOTOR WITH POWER FACTOR CONTROL

Official Plan Amendment for Scarborough Rapid Transit (SRT) Extension Final Report

16028 September 23, 2016

WINDOW-TYPE AIR CONDITIONER

BRINGING GLASS to life. Beauty from within... INNOVATION COMES BUILT-IN

Crimsafe & Safety. Traditional Diamond Grille Premier Crimsafe Security Protect Your Lifestyle. Ph:

NFPA 80 Overview January 21, 2016

A1 Blinds Product Care & Trouble Shooting Guide

Data Sheet 4.16 Issue D

VDE-QT-PV001:2012/01

DS/EN DK NA:2011

Established in 1926 SELECTING YOUR WINDOW FURNISHINGS

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

ISO 7491 INTERNATIONAL STANDARD. Dental materials Determination of colour stability. Produits dentaires Détermination de la stabilité de couleur

Transcription:

Istituto Giordano S.p.A. Via Gioacchino Rossini, 2-47814 Bellaria-Igea Marina (RN) - Italia Tel. +39 0541 343030 - Fax +39 0541 345540 istitutogiordano@giordano.it - www.giordano.it PEC: ist-giordano@legalmail.it Cod. Fisc./Part. IVA: 00 549 540 409 - Cap. Soc. 1.500.000 i.v. R.E.A. c/o C.C.I.A.A. (RN) 156766 Registro Imprese di Rimini n. 00 549 540 409 TEST REPORT No. 357417 Place and date of issue: Bellaria-Igea Marina - Italia, 18/12/2018 Customer: IDECO ARIGIRIS PAPADOPOULOS INDUSTRIAL S.A. - Egnatia Odos Veria-Thessaloniki km 10,000 - Veria, IMATHIA - Greece Date testing requested: 09/10/2018 Order number and date: 78085, 09/10/2018 Date sample received: 09/03/2018 Date of testing: 05/12/2018 Purpose of testing: testing the wind resistance of an insect screen with guiderail with fabric running into the lateral rails and without tension system according to clause 7.4 of standard UNI EN 1932:2013 with test parameters and results evaluation according to standard UNI EN 13561:2015 Place of testing: Istituto Giordano S.p.A. - Strada Erbosa Uno, 72-47043 Gatteo (FC) - Italia Origin of sample: sampled and supplied by the Customer Identification of sample received: No. 2018/0517 Name of sample* The test sample is named EL GRECO-11130-ONE LEAF LATERAL (1200x2200). (*) according to that stated by the Customer. Comp. MB Revis. PB This test report consists of 6 sheets. CLAUSES: This document relates only to the sample or material tested and shall not be reproduced except in full without Istituto Giordano s written approval. Sheet 1 of 6

(Test report No. 357417 dated 18/12/2018) sheet 2 of 6 follows Description of sample* The sample under test consists of an insect screen with guiderail with fabric running into the lateral rails and without tension system, with caterpillar down and cord up, nominal size 1200 mm 2200 mm. The sample in details is composed by: curtain, stated openness coefficient Co 65 %; retention guide made of a C-shaped profile, section 20 mm 39 mm; lateral guide, section 56 mm 35 mm; sliding guide, section 56 mm 35 mm; top guide made of a C-shaped profile, section 65 mm 40 mm; lower plastic track chain, which facilitates the folding of the curtain and conceals itself inside the profile as the curtain opens. Photograph of the sample. (*) according to that stated by the Customer.

(Test report No. 357417 dated 18/12/2018) sheet 3 of 6 follows Detail of the label. Normative references Testing was carried out according to the following standards: UNI EN 13561:2015 dated 09/07/2015 Tende esterne e tendoni - Requisiti prestazionali compresa la sicurezza ( External blinds and awnings - Performance requirements including safety ); UNI EN 1932:2013 del 18/07/2013 Tende e chiusure oscuranti esterne - Resistenza al carico del vento - Metodo di prova e criteri di prestazione ( External blinds and shutters Resistance to wind loads Method of testing and performance criteria ). Test apparatus Testing was carried out using the following equipment: measure and control computerized semiautomatic system with differential pressure transducers; Mitutoyo Corporation digital meter model TD-S551D1 216-452, full scale 5500 mm (in-house apparatus code: FT364).

(Test report No. 357417 dated 18/12/2018) sheet 4 of 6 follows Test methods The test was performed in accordance with clause 7.3 Awnings with lateral guiderail without fabric running into the lateral rails and without tension system of standard UNI EN 1932:2013 and with clause 4.1 Resistance to wind loads of standard UNI EN 13561:2015. The test loads for the reference class in clause 4.1 of standard UNI EN 13561:2015. The sample was tested to determine the wind load resistance using method 3: applying a direct nominal pressure p S, for at least 2 min, defined as p S =p N-Co>20% γ where: p N = threshold value of nominal test pressure, in N/m 2, corresponding to the class considered in accordance with table 1 of standard UNI EN 13561:2015; Co = openness coefficient of the fabric; γ = 1,2 (coefficient of transition from the nominal loads to the safety loads; releasing and inspecting; applying reverse safety pressure -p N, for at least 2 min, releasing and inspecting. The drop test was not performed since it was not feasible because of the conformation of the sample. Environmental conditions at the time of testing Room temperature (19 ± 1) C Relative humidity (54 ± 5) % Test results Load method* 3 Width L 1,200 m Height H 2,200 m (*) according to clause 5 of standard UNI EN 1932:2013.

(Test report No. 357417 dated 18/12/2018) sheet 5 of 6 follows Wind load resistance test. Applied load Side* Result** [Pa] 46 outer complying (*) The sample has been tested only on one side because it is statically symmetrical. (**) According to clause 7.4.6 Performance criteria of standard UNI EN 1932:2013 there shall be no: - tearing in fabric; - breakage (stitching, guiding pins..); - permanent deformations (profiles, rails, roller tube..); - exit from guide rails. Photograph of the sample during test.

(Test report No. 357417 dated 18/12/2018) sheet 6 of 6 follows Findings On the basis of the test performed, on the basis of the results obtained and based on standards UNI EN 13561:2015 and UNI EN 1932:2013, the test sample, comprising an insect screen with guiderail with fabric running into the lateral rails and without tension system, called EL GRECO-11130-ONE LEAF LATERAL (1200x2200) and submitted by the company IDECO ARIGIRIS PAPADOPOULOS INDUSTRIAL S.A. - Egnatia Odos Veria-Thessaloniki km 10,000 - Veria, IMATHIA - Greece, results to belong, according to clause 4.1 of standard UNI EN 13561:2015, to the performance class specified in the following table. Test type Test reference Class reference Class wind load resistance UNI EN 1932:2013 UNI EN 13561:2015 3 The results given refer exclusively to the test sample itself and are only valid under the same conditions in which testing was carried out. This test report alone shall not be considered a certificate of conformity. Test Technician (Dott. Ing. Paolo Bertini) Head of Security and Safety Laboratory (Dott. Andrea Bruschi) Chief Executive Officer......... The original of this document consists of an electronic document digitally signed pursuant to the applicable Italian legislation.