FIRE SUPPRESSION SOLUTIONS

Similar documents
Fire protection solutions for ships and offshore facilities

Fire protection solutions for ships and offshore facilities BRANCH SOLUTION

AUTROSAFE. An interactive fire detection system for larger vessels

HI-FOG for Ro-Ro and Special Category spaces

Turning expertise and innovations into marine solutions

Performance Based Fire Protection With Water Mist

AutroVoice voice alarm system AUTROVOICE VOICE ALARM. Loud and clear information

MAINTENANCE AND INPSECTION OF FIRE PROTECTION SYSTEMS AND APPLIANCES

Fixed Fire Extinguishing Equipment and Systems

SHIPBUILDING FIRE PROTECTION WATER MIST SYSTEM SAID. DONE!

Global Marine Solutions and Services From Ship to Shore Single Source Providers for Fire, Security, Life Safety

Fire. IMO fire control signs - according to IMO Resolution A.654 (16) (mm) 150x x200

Notice on the implementation of the amendments to the FSS Code in resolution MSC.339(91)

AutroSafe interactive fire detection system AUTROSAFE. An interactive fire detection system for complex installations

FIRE SUPPRESSION SYSTEM

DESIGNER AND SUPPLIER OF MARINE FIRE FIGHTING SYSTEMS

Government of Bermuda Bermuda Shipping and Maritime Authority BERMUDA SHIPPING NOTICE

ADDITIONAL FIRE PROTECTION (F-AMC)

THÔNG BÁO KỸ THUẬT TÀU BIỂN TECHNICAL INFORMATION ON SEA-GOING SHIPS

Additional Fire Protection (F-AMC)

IMO INTERPRETATIONS OF FIRE PROTECTION-RELATED PROVISIONS OF THE HSC CODE

Superior by Design The Kidde ADS TM FM-200 System

RESOLUTION MSC.339(91) (adopted on 30 November 2012) AMENDMENTS TO THE INTERNATIONAL CODE FOR FIRE SAFETY SYSTEMS (FSS CODE)

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

Element C3.4 Fire Fighting Equipment

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

Global Marine Solutions. From Ship to Shore, single source providers for Fire Protection, Electronic Security, Life-Safety and Communications Systems

What is HI-FOG? The natural enemy of fire

Fire fighting Questions

How can I protect invaluable assets and the environment from the effects of a fire?

A safe journey with Dräger CRUISE CATALOGUE

MAIB SAFETY BULLETIN 2/2010. Failure of fixed high expansion foam system to extinguish fire on board the passenger ferry Oscar Wilde

(2) Various fire sections enclosed by various classes of fire divisions; (3) Arrangement of fire detectors and manual fire alarm stations;

NOVENCO GROUP IMPROVING COMFORT AND SAFETY ON LAND AND AT SEA

LOW EXPANSION FOAM FIRE EXTINGUISHING SYSTEM

PORTABLE FIRE EXTINGUISHERS. Fire Safety.

MSC Guidelines for Foam Fire Suppression Systems

FIRE PROTECTION TECHNOLOGY Solutions never thought of before

Introduction. Our team

F&G detection system for LNG plants

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Fire Protection Systems and Equipment

MSC Guidelines for Automatic Sprinkler Systems

Main changes in BV Rules for Steel Ships

Part 6 Additional class notations Chapter 6 Additional fire protection for passenger vessels

MB05. RESPOND TO EMERGENCIES BASIC KNOWLEDGE OF EMERGENCY PROCEDURES, INCLUDING EMERGENCY SHUTDOWN

DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

Schedule of Accreditation

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle.

GUIDELINES FOR THE APPROVAL OF HELICOPTER FACILITY FOAM FIRE-FIGHTING APPLIANCES

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

IMO. Resolution A.952(23) Adopted on 5 December 2003 (Agenda item 17) GRAPHICAL SYMBOLS FOR SHIPBOARD FIRE CONTROL PLANS

FIRE SAFETY SHIPS RULES FOR CLASSIFICATION OF NEWBUILDINGS DET NORSKE VERITAS MACHINERY AND SYSTEMS MAIN CLASS PART 4 CHAPTER 10 JULY 2006

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

Safety is more than just being careful: it

3. Low location lighting system. 4. Illuminated emergency units. 5. Cabin escape route plans

TALK SAFETY WITH US MARINE SAFETY TECHNOLOGY. When Safety Matters


Requirements for ships carrying hydrogen and compressed natural gas vehicles

High pressure water mist sprinkler system for fighting fires

Technical Information

CERTIFICATE OF FIRE APPROVAL

MistMax Pro; A WaterMist fire skid designed for your UTV or smaller fire fighting vehicle. TM TM

BOC FS125 The Fire Extinguishing Solution

Sinorix Silent Extinguishing Technology protecting the quiet way

Dual Agent Unit w / Atmospheric Tank 200 Litres DAHR 01

Fire protection for buildings

WATER MIST CONVENTION AND EXHIBITION

UNIFIED INTERPRETATIONS OF SOLAS CHAPTER II-2, THE FSS CODE, THE FTP CODE AND RELATED FIRE TEST PROCEDURES ***

How can you minimize consequential damages in case of a fire?

Fire, Safety & Damage Control Systems for Naval Applications

BMA INFORMATION BULLETIN No. 97 FIRE FIGHTING EQUIPMENT

Amendments to the Revised Guidelines for the Maintenance and Inspection of Fire Protection Systems and Appliances (MSC.1/Circ.

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

AUTROSAFE 4 A new level in interactive fire detection systems

The Next Generation of Foam Fire Suppression. Automatic CAF Fire hose reel system FEATURES

The History of IWMA. 18th International Water Mist Conference will (IWMC) take place in London on 19th & 20th September 2018

Manager Other (Specify) Gross Tonnage: Main Propulsion (kw): Generating Power (kw):

IACS RESOLUTION CHANGES (GMO ) BEKİR SITKI TÜRKMEN

Fire Suppression. Water-Mist : A Revolutionary Green Technology in. - by Nimit Sheth TALL, SMART, SAFE BUILDINGS FOR SMART CITIES.

Ships and marine technology Fireextinguishing. of galley cooking equipment

ODS & SGG Alternatives for the Fire Protection Industry 2018

Approval of water mist systems in buildings

SINGLE MONITORED INPUT UNIT BN-303

ClassNK Technical Information No. TEC-0970 For any questions about the above, please contact: NIPPON KAIJI KYOKAI (ClassNK) Survey Department, Adminis

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Fire fighting excellence. HI-FOG water mist fire protection

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Optimising Performance

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

Full-scale test of fire detection in a facade using heat detection cable and flame detector

Intelligent Security and Fire Solutions. Southern Africa

3M Novec 1230 Fire Protection Fluid For Marine Applications. Created. Life. for

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

IMO FP 53 Report. Lloyd s Register report on the 53 rd session of IMO Fire Protection Sub-Committee. 16 th March, 2009

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

Transcription:

FIRE SUPPRESSION SOLUTIONS

MARITIME FIRE SUPPRESSION In the maritime world space is a luxury. That is why it is important getting maximum effect from your fire suppression with a space and power-efficient system. We provide solutions optimised for all kinds of vessels from tankers to yachts. All the fire safety you need from one supplier Integration of all the fire-safety equipment ensures that the correct response is made automatically; the integration of fire detection and suppression is a logical step. It can be difficult to get equipment made by two different suppliers to work together in a satisfactory way, and costs and installation time increase accordingly. That is why we offers the total safety solution for maritime applications. Autronica Fire and Security the natural choice for your fire suppression needs. Helideck Autronica drencher system Ro-Ro and special category spaces Autronica drencher system Galley Wet chemical CO2 galley duct Accommodation and service spaces FlexiFOG accommodation Bunkering station Autronica DCP system Machinery spaces FlexiFOG total flooding FlexiFOG local protection NOVEC gas Car deck Autronica drencher system 2 3

LOW-PRESSURE WATER MIST The future of water suppression Low-pressure water mist is the logical successor to sprinkler or high-pressure water mist systems. It requires a minimum of power and water, it offers ease of installation, and it benefits from the use of standard components. The feature of FlexiFOG water mist system is the advanced technology producing a mixture of small droplets in combination with mist, when activated. This ensures a quicker and more reliable suppression of fires in accommodation areas than any other system can offer. FlexiFOG water mist fire suppression system can protect accommodation, service areas and machinery spaces (total flooding and local protection) with one single pump package. FlexiFOG water mist systems are cost effective both when it comes to purchase and installation. Compared to traditional sprinkler systems, FlexiFOG offers significant advantages, for instance: v v Low water consumption v v Low piping weight, PN10 and PN16 v v Reduced risk of clogging The logical successor to sprinkler or high-pressure water mist systems v v Low power consumption v v Higher reliability Low profile flush mounting and colour adaptation to surroundings (for accommodation spaces only) FlexiFOG water mist systems are type approved by all major classification societies and hold wheel mark certificates, and can be supplied in compliance with Safe Return to Port requirements. Critical design parameters Weight and power consumption are always critical design parameters, and has been one of the key parameters when developing the nozzles. The design on a medium sized ferry with approximately 1500 nozzles, enables a weight reduction of approx. 2 tons and the required power output is reduced with approximately 30 kw. This means that the emergency generator can be smaller, reducing cost and fuel consumption. 4 5

DRENCHER SYSTEMS From car decks to helidecks Autronica drencher systems are reliable, simple and effective fire suppression systems offering significant advantages: Quick fire suppression Sea water can be used, even with water mist nozzles Prevent fires from spreading over a large area by means of water curtains Cool down protected equipment Simple and reliable operation High flexibility in design and installation Autronica drencher systems are used to protect different areas onboard, both inside and outside. For instance: Cargo tank decks onboard chemical/oil tankers LFL and seismic vessels Car-decks (open or closed) Helidecks, helicopter landing areas and garages Bow and stern loading areas. LNG and other fuel tanks Discharging devices Autronica can deliver a broad range of discharging devices to meet the requirements set by applicable regulations and to satisfy the needs of each specific vessel. In particular for car decks, we can offer a water mist nozzle approved with use of sea water: this is a unique product providing huge benefits to our customers: Highly reduced water consumption (around 1/3 compared to traditional water spray nozzles) Smaller drainage pumps No need for dedicated water pumps No need for fresh water tank Other discharging devices include: Jet/fog nozzles, manually and remotely operated monitors, water spray nozzles, branch-pipes, pop-up nozzles, hose reels, and foam/water guns. All foam discharging devices have been tested according to the relevant regulations and fulfill IMO requirements. Depending on the application, low expansion foam in different mixing concentration can be added to the water. All the foams concentrates are approved by all the major classifications societies and fulfill IMO requirements. 6 7

NOVEC GAS SUPPRESSION Critical facilities require fire protection systems which can detect and suppress fires quickly without harming equipment, the facility or the environment. Autronica Novec 1230 Engineered Fire Suppression System is designed to protect human life and high value assets from fire, meeting the marine industry s concerns for safety, performance and the environment. Compared to traditional gas suppression systems, it offers significant advantages: Protecting life, environment and property v v Very quick fire suppression v v Minimal storage space for the gas cylinders v v No damages to the protected equipment v v Zero ozone depletion potential and very low atmospheric lifetime (5 days) v v Great margin of safety for use in occupied spaces. v v Fastest possible clean-up after discharge (no residuals) v v Down-time kept at a minimum Easy and quick re-filling of gas cylinders. Autronica Novec 1230 systems are ideally suited to the protection of machinery spaces, cargo pump rooms, control and switchboard rooms in a wide range of vessel types. 8 9

GALLEY SYSTEMS 24-hour protection for cooking facilities onboard Equipped with deep fat fryers and a myriad of other high-temperature cooking appliances, no other environment demands proper fire protection more than today s modern cooking facilities onboard. Autronica can provide two different pre-engineered systems specifically designed for the challenging demands posed by these areas. Wet chemical system for the protection of deep fat fryers Autronica wet chemical system is an effective and reliable fire suppression system designed to extinguish fires in deep fat fryers quickly and effectively. The wet chemical agent does not damage surrounding work surfaces, is not toxic or harmful and is easy to wash away after discharge. Autronica wet chemical system holds type approval certificates from all the major classifications societies as well as wheel mark certificate. Photo: RCCL CO2 gas suppression system for the protection of galley ducts. Autronica CO2 system is specifically designed for the protection of one or more galley ducts. The system is simple to operate and is designed to quickly achieve the necessary CO2 concentration to extinguish a fire inside a galley duct.

DRY CHEMICAL POWDER SYSTEM For bunkering stations The new IGF Code (International Code of Safety for Ships using Gases or other Lowflashpoint Fuels) adopted by MSC requires a permanently installed dry-chemical powder fire-extinguishing system in the bunkering station areas to cover all possible leak points. Autronica has developed its own dry chemical powder system to fulfill new IMO requirements and satisfy our customers needs. Autronica pre-engineered dry chemical powder system is simple to operate and its high effectiveness has been proven during specific fire tests where the flames were extinguished almost immediately. The system is non-toxic and harmless to people and the environment. The system holds DNV type-approval, ensuring compliance with IMO require ments. 12 13

Thinking new thoughts is part of our job. That is how we create products that make you feel safe. More than fifty years ago, we invented the very first fire alarm as you know it today. Since then we have turned it upside down several times and still we continue to make new revolutions. Our goal has always been that people should be able to think less about what matters most; safety. We know that our products are amongst the best in the world, but we also know that the best products can always get better. We continue to develop and we are able to say with conviction, that we protect life, environment and property. Protecting life,environment and property www.autronicafire.com

Autronica Fire and Security AS is a leading innovator, manufacturer and supplier of fire and gas protection, safety and maritime measuring equipment worldwide. Our products ensure safety in applications on land, sea and in the petrochemical, oil and gas sectors. Owned by United Technologies Corporation (UTC), we employ almost 500 people handling the complete value chain, from idea, development and manufacturing to the marketing, sales and servicing of our products. We are an international company with worldwide offices and our HQ is located in Trondheim, Norway s technology hotspot. 16 Autronica Fire and Security AS DIVISION MARITIME Bromstadveien 59, NO-7047 Trondheim, Norway Tel: +47 90 90 55 00 E-mail: sales.maritime@autronicafire.no www.autronicafire.com 116-P-SUPPRESSION/MAR/AGB, rev. A, 2016-11-21