AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS Copyright 2010 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 07/10 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Catalog No:---01SB Replaces: New
Job Data: Location: Buyer: Buyer P.O.#: Carrier: Unit Number: Model Number: Unit Designation: Performance Data Certified By: Use of the AHRI Certified TM Mark indicates a manufacturer s participation in the program For verification of certification for individual products, go to www.ahridirectory.org. DESCRIPTION units are high-efficiency, single-packaged electric cooling, gas heating units that are pre-wired and pre-charged with Puron R (R-410A) HFC refrigerant. The units are factory tested in both heating and cooling modes. These units meet the ASHRAE 90.1 efficiency levels. Certified to ISO 9001:2008 Base Unit S Puron (R-410A) HFC refrigerant S EER 11.0 S Rated in accordance with AHRI Standards 340/360 S Designed in accordance with Underwriters Laboratories Std 1995 and listed by UL and UL, Canada S Single -stage capacity control S Non-corrosive composite sloping design; side or center drain condensate pan. Meets ASHRAE Standard 62 S Standard cooling operating range from 40_F upto 115_F (4_C upto46_c). Field installable accessory extends the minimum down to -20_F (-29_C) S Field convertible from vertical to horizontal airflow for slab mounting No special kits required S Return air filters are two-inch metal frames with pleated media S Single point gas and electric connections S 24-volt control circuit protected with resettable circuit breaker S Belt drive, constant torque, permanently lubricated evaporator-fan motor S Totally enclosed condenser motors with permanently lubricated bearings S Low-pressure and high-pressure switches S Full perimeter base rail with built-in rigging adapters and fork truck slots S Centralized terminal board facilitating simple safety circuit troubleshooting and simplified control box arrangement S Surveyor controller and associated sensors S Power and control wiring through the base Meyer hubs and compressor relay STANDARD FEATURES Cabinet S Access panels with easy grip handles S Innovative, easy starting, no-strip screw feature on unit access panels S Pre -painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection S Fully insulated cabinet S Tool-less filter access door S Hinged panel access for the control panel and evaporator blower motor. Refrigerant System S Acutrolt refrigerant metering system S Liquid line filter drier S Scroll compressors with internal line-break overload protection S Copper tube, aluminum fin coils with optional corrosion resistant coils S Removable gauge line plugs for reading refrigerant pressure with unit panels in place Gas Heat S IGC solid-state gas heat exchanger control for on-board diagnostics, anti -cycle protection, LED error code designation, burner control logic and energy saving indoor fan motor delay S Gas efficiencies up to 82% S Inducted draft combustion S Redundant gas valve, with 2 states of heating S Flame roll -out safety protector S Solid-state electronic direct spark ignition system 2
STANDARD FEATURES (cont.) Standard Warranty S 15-year gas heat exchanger parts - Stainless Steel S 10-year gas heat exchanger parts - Aluminized S 5-year compressor parts S 1-year parts PERFORMANCE DATA Unit Operating Weight lb Cooling Gross Total Capacity: at Condenser Air Temperature _F Gross Sensible Capacity: Compressor Power Input: kw Indoor Entering db _F wb _F Airflow External Static Pressure in.wg Indoor Fan Motor Size Hp Exhaust Fan Motor Size Hp Curb Weight Heating Heating Capacity: Stage 1 Stage 2 Heating Capacity Total Stage 1 Stage 2 Heating Capacity Total lb kw kw kw ELECTRICAL DATA Power Supply to Unit Volts Phase Hz Minimum Circuit Amps Maximum Overcurrent Protection Job Name Architect Engineer Contractor Unit Designation SUBMITTAL DATA 3
OPTIONS AND ACCESSORIES FACTORY -INSTALLED OPTIONS (FIOPs) j Stainless steel gas heat exchanger (includes tubes, vestibule plate and collector box) j Economizer with dry bulb sensing and barometric relief j Economizer with enthalpy sensing and barometric relief j Non-fused disconnect j High static evaporator fan motor j Return Air smoke detector j Condenser hail guard - louvered style j Special coating protection for evaporator and condenser coils OPTIONAL WARRANTIES j Complete Unit Parts only up to 5 years j Complete Unit Parts and Labor up to 5 years Many other optional warranties are available. See the Commercial Start -Up and Optional Extended Warranty Price price pages for further information. FIELD INSTALLED ACCESSORIES j Economi$ert IV-electromechanical, gear driven with Belimo actuator (2-10v DC signal) and controller j Economi$ert2-compatible with DDC controls; gear driven with Belimo actuator (4-20mA) signal and no controller j Power exhaust j Manual outside air damper 25% j Manual outside air damper 50% j Roofcurb - 14 inch (356mm) tall j Roofcurb - 24 inch (610mm) tall j Thru-the -bottom connections-electrical only j Thru-the-bottom connections-electrical and gas j Condenser hail guard - louvered style j Flue shield j Flue discharge deflector j Liquid propane (LP) conversion kit j High altitude conversion kit j Phase monitor (loss of phase/phase reversal) j Winter start kit, down to 25_F (-4_C) j Low ambient head pressure controller, downto0_f (-18_C) j Low ambient head pressure controller, down to -20_F (-29_C) j Time Guard II compressor anti -cycle protection j Return Air smoke detector j Supply Air smoke detector j Thermostats and Sensors Economizer Sensors j Single Dry bulb control j Differential Dry bulb control j Single enthalpy control j Differential enthalpy control j CO 2 - wall mounted j CO 2 - duct mounted j CO 2 - unit mounted 4
CERTIFIED DIMENSION *07 C10705 5
CERTIFIED DIMENSION *07 C10706 6
ROOF CURB DETAILS CONNECTOR PKG. ACCY. CRBTMPWR001A01 CRBTMPWR003A01 B 1-9 11 / 16 [551] C 1-4 [406] D ALT DRAIN HOLE 1 3 / 4 [44.5] GAS POWER CONTROL ACCESSORY POWER 3/ 4 [19] NPT 3/ 4 [19] 1/ 2 [12.7] 1/ 2 [12.7] 1/ 2 [12.7] NPT NPT NPT NPT ROOFCURB ACCESSORY CRRFCURB001A01 CRRFCURB002A01 A 1-2 [356] 2-0 [610] UNIT SIZE *07 NOTES: 1. Roof curb accessory is shipped disassembled. 2. Insulated panels. 3. Dimensions in [ ] are in millimeters. 4. Roof curb: galvanized steel. 5. Attach ductwork to curb (flanges of duct rest on curb). 6. Service clearance: 4 ft on each side. 7. Direction of airflow. 8. Connector package CRBTMPWR001A01 is for thru-the-curb type gas. CRBTMPWR003A01 is for thru-the-base type gas connections. C10707 7
8