LHCb Rich Detectors Control and High Voltage Systems

Similar documents
Towards a Detector Control System for the ATLAS Pixeldetector

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

Expected needs in Electronics for the CERN Experiments. 5 October 2015

Humidity sensors. Behavior in different environments. Supervisor: Vaclav Vacek Collaborators: Martin Doubek, Martin Janda and Michal Vitek 28.9.

Laser Scan Micrometer Page 418. Laser Scan Micrometer Page 423

Stato di LHCb. P. Campana CSN1 14 maggio Il Trigger L0 dei Calorimetri Il sistema dei RICH Il sistema a Muoni

FEATURE ARTICLE. The PLCA-800 Series Inline Particle Sensor for Chemical Solutions. Yoshihito Yuhara. Abstract

Active Scanning Beam 2: Controlling Delivery

The LHCb Outer Tracker: Production & Ageing studies

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Fire and Gas Monitoring Panel ST7-HV

Status of the LHCb Detector. LHCC Open Session CERN, 27 November 2002 Werner Witzeling on behalf of the LHCb Collaboration

Physics Requirements for the CXI Detector Stage

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

Doc. No. SP R0. CXI Detector stage. Prepared by: Signature Date Jean-Charles Castagna Design Engineer

2 Overview of the Pixel Detector Control System

Analog Annunciator Unit SACO 16 A3. Product Guide

S ATION EWORK ST BGA R

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

3kW 6kW, QUBE Fiber Lasers

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

2-wire Passive Intelligent Loop (LED) Display Meter

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

Surface Concept Product Catalog 2014

SEC Signature Process Gas Analyzer

S ATION EWORK ST BGA R

5.1 Safety instructions for system configuration and explosion protection. Zone-specific conditions for system configuration

BGA Rework Station Pro-660

RICH Status Report. Tyler Lemon Detector Support Group. Rich Status Report. Tuesday, August 23, 2016

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

2-wire Passive Intelligent Loop (LED) Display Meter

FTIR-OEM IR source, interferometer & detector modules for modular and OEM applications

Intelligent addressable fire alarm control panel

ESTB Proposal from the Stony Brook University: Test of a RICH-Prototype Based on CsI-GEMs

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System. SENSORS & SYSTEMS Authority in Displacement Measurement ILD 1800

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

R&D Fast and lightweight EIC integrated tracking system Barrel MicroMegas & Forward Triple-GEM

Design specifications and test of the HMPID s control system prototype in the ALICE experiment

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

WHAT IS LASER ULTRASONIC TESTING?

System Test of the ATLAS Muon Spectrometer in the H8 Beam at the CERN SPS

Danfoss gas detection unit Type GD Heavy Duty

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

Annunciator unit. Application

SYSTEMS THINKING AND TROUBLESHOOTING

89BSD Digital Output

Annunciator Unit SACO 16 D1. Product Guide

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

CALICE: status of a data acquisition system for the ILC calorimeters. Valeria Bartsch, on behalf of CALICE-UK Collaboration

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Temperature Solutions Line Card

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Praetorian Fibre Optic Sensing

CTT8 TEMPERATURE MONITOR DEVICE

HDCVI PIR Camera User s Manual

Analogue Detectors. Series 200 plus

ClampOn DSP Corrosion- Erosion Monitor

Analog Room Pressure Monitor RPC Series

Innovation right to the point. Optical distance detection. Low cost and compact due to PMD technology.

RS485 MODBUS Module 8AI

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

An FPGA Spectrum Sensing Accelerator for Cognitive Radio

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Fiber Optical Multiplexer

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

EasyLog Data Logger Series

XRD XRD-1500 High-Temperature Oven. Innovation in Material Science...

Instrumental technique (MCP detectors) - Kamalesh ( )

EasyLog Data Logger Series

Variable Temperature Microprobe Systems

MO n : 12JMC rév A

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

RAYCHEM NGC-30 COMPONENTS

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

HUM-M2 Humidity Sensor Module Description

Cooling test results C-side replacement detector

4/8/12/16 Channel Temperature Scanner with FREE Data Logging PC Software RS485

AIDA Advanced European Infrastructures for Detectors at Accelerators. Presentation. LumiCal alignment system, status report

ACCESS AND ALARM SAFETY SYSTEMS ACTIVITIES FOR THE 2012/2013 LONG SHUTDOWN*

Technical specifications of FT-IR Spectrometer

Type TEC, Transformer Electronic Control System

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

ISO AIR FILTERS FOR GENERAL VENTILATION: DETERMINING FRACTIONAL EFFICIENCY

Temperature Data Logging

i-con Switchgear Condition Monitoring HV Switchgear Integrated Substation Condition Monitoring ISCM Answers for Infrastructure & Cities.

Industrial Fire Detection

FEE Diagnostics and Commissioning. June 17, 2008

Air & Water Heat Pump R832

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

Technical Specification PILATUS 100K Detector System

FPIAA - Find Persons Inside Atlas Areas A system for finding and rescuing persons in a very large physics experiment

Team Rescue X: Autonomous Firefighting Robot

Transcription:

LHCb Rich Detectors Control and High Voltage Systems Mario Sannino On behalf of LHCb RICH Group Rich 2007 Trieste 19.10.2007 1 Rich 2007 Trieste 19.10.2007

LHCb Rich Detectors Control and High Voltage Systems An overview of the Monitoring/Control System of the RICH Detectors in LHCb experiment will be presented In particular this talk will concentrate on the Monitoring/Control methods fundamental for an efficient RICH Detector operation Rich 2007 Trieste 19.10.2007 2

LHCb RICH detectors Mirror Support Panel Flat mirrors Spherical mirrors 8m Spherical Mirror Support Structure 4m Beam pipe Photon detector housing and shielding RICH1: 2-60 GeV/c RICH2: 17-100 GeV/c Flat Mirror Central Tube Photon detector housing Rich 2007 Trieste 19.10.2007 and magnetic shielding 3

Fundamental for an efficient RICH operation are: Low Voltage and High Voltage control and monitoring environment monitoring (temperature, pressure, humidity) radiator gas quality monitoring mechanical stability (mirror alignment) monitoring detector safety This is achieved by means of the DCS (Detector Control System), in charge of detector operation, i.e. Monitoring, Control and low level Safety. DCS will also automatically recover simple problems and restore normal operating conditions. Rich 2007 Trieste 19.10.2007 4

LHCb Partial Simplified view ECS = Experiment Control System DCS = Detector Control System DSS = Detector Safety System Rich 2007 Trieste 19.10.2007 5

ECS/DCS Hardware Implementation Board level electronics Electronics in barracks (out of Radiation Area) Front-ends, Readout Units, Timing and Fast Control components, VHV Control Credit Card PC s Ethernet interfaced acting as an embedded controller generating needed I2C, JTAG and a parallel bus by means of a proper glue logic (Glue Card) 66 85 12 mm 3 Pentium Compatible CPU Linux/DIM Credit Card PC Ethernet S S S I2C JTAG Bus I2C JTAG Bus I2C JTAG Bus Glue-Card 6

ECS/DCS Hardware Implementation Front-End Electronics In Radiation Areas needed I 2 C and JTAG generated by the busses SPECS Serial Protocol (inspired from Atlas) 10Mb/s Slave is radiation tolerant CAN protocol (0.5Mb/s) in charge of controlling ELMB s (used for Environmental and Voltage monitoring) SPECS CAN S S S I2C JTAG I2C JTAG I2C JTAG M I 7

Implementation of LHCb RICH Detectors Monitoring Rich 2 ECS supervisor PC PVSS II Supervisory Level (Control Room) Control Level (Counting Room) Rich2 Voltage and Environment Monitoring Rich2 Power Supplies Control Rich2 VHV Power Supplies Control Quality Monitoring Sensors T, P,H Environmental Monitoring ELMBs Radiation Area Voltages Voltage Monitoring LV, HV, L1 Power Supplies Other (DSS, ) HPD Planes Temp. Device/Sensor Level Environmental monitoring is implemented by means of resistive transducers ( (PT100 &1000 for T, Diaphgram Sensors for Pressure, HMX2000-HT sensors for Humidity) ELMBs are CAN controlled monitoring boards with 64 analog input channel 16 bit res. PLC Safety Interlocks VHV Power Supplies Gas Quality Alignment Quality Monitoring Rich 2007 Trieste 19.10.2007 8

Environmental Parameters Monitoring HPD box temperature Environmental Parameters PVSS II typical Monitoring Panels HPD box humidity <- 5 days -> RICH2 CF 4 radiator temperature Rich 2007 Trieste 19.10.2007 9

Gas Radiator quality Monitoring (I) The Gas Purity is critical to a reliable working of the RICH Detectors. Speed of sound in gases depends on molecular weight: and so it can be exploited to quickly spot gas pollution. vsound = γrt M γ = c p /c v is the ratio of specific heats R is the constant of gases T is the absolute temperature M the molecular weight Effect of air contamination C 4 F 10 CF 4 n 1.0014 1.0005 Gas N O air C 4 F 10 CF 4 Molecular weight 28 32 29 238 88 Theta max (mrad) 52.88 31.62 Speed of sound (m/s) at 30 C 354 332 349 ~130 ~150 1% N 2 θ max 52.68 (0.2) 31.55 (0.07) 3% N 2 52.26 (0.62) 31.42 (0.2) Typical error (mrad) 1.5 0.6 Rich 2007 Trieste 19.10.2007 10

Gas quality Monitoring (II) Speed of sound is monitored by measuring the time that a sound pulse takes to propagate back and forth along a gas column after having been reflected by the opposite wall. 2 such Systems on each Rich One on gas inlet A second on gas outlet The heart of the system is an electrostatic transducer acting both as source and detector. The time measurement is performed by a National Instrument Acquisition Board with an internal counter running at 20 MHz so, with a resolution of 50 ns This is enough to detect a 1% CO 2 pollution in C 4 F 10 (see graph) 10 11

Flat Mirror Laser alignment monitoring system (I) HPD Plane Beam Splitter Focuser CCDs Mirror Spherical Mirror Common Mounting Plate Mirror position must be known with good precision and any change of it must be tracked as accurately as possible. A 0.1 mrad resolution is required as seed for final software alignment. An optical system has been implemented in order to monitor changes in selected mirror segments. Working principle: Laser with optical fibre coupling system delivers light to 16 fibres in Rich2 and 8 fibres in Rich1. Each fibre has a focusing unit at its end and is focused onto a mirror segment (4 spherical and 4 flat per side). A beam splitter provides a reference beam for each fibre focused on a CCD camera on roof of detector. A second beam reaches the mirror and then is reflected back to the CCD camera. Rich 2007 Trieste 19.10.2007 12

Laser alignment monitoring system (II) Can track difference between two beam spots, even if spots move: Accuracy of monitoring better than 0.01 mrads. 13

VHV Power Supplies Control System (I) In LHCb Rich a custom VHV system for the HPD field supply was needed due to the fact that no commercial power supply satisfied our requirements: 20KV output Ethernet network interface compatible with CERN standard Reliable and modern (maintenance!) Architecture of the system The system is composed by 3 items: 1. Commercial HV unit: One unit for each column. 2. Motherboard with local intelligence One unit for each Detector 3. Control Board with optical isolation (avoid Gnd loops) One unit for each column Rich 2007 Trieste 19.10.2007 14

VHV Power Supplies Control System (II) Rich 2007 Trieste 19.10.2007 15

VHV Power Supplies Control System (III) Commercial HV unit: ISEG CPn 200 504 10-K 0-20 KV output Imax = 0.5 ma Remote control: analog input 0-10V Possibility to set Imax with a control voltage Monitoring of V out and I out Reasonably priced Custom version possible (2 output cable to cope with the HV splitter) Rich 2007 Trieste 19.10.2007 16

VHV Power Supplies Control System (IV) Standard VME size card ( 6U type) Local Intelligence: Credit Card PC (CCPC) Ethernet interface built-in CERN fully supported Easily interfaced with external devices by means of the so called Glue Card. Connections with Control Boards implemented by means of 4 I2C buses (from the Gluecard) Interlock Management and distribution entirely controlled by a small FPGA The Motherboard 17

VHV Power Supplies Control System (V) Control Board ISEG VHV Power Supply 17 18

Installation of VHV Rich Power Supplies in LHCb Pit 19

VHV Power Supplies Stability (19540 ± 18) V A stability of the ouput voltage under load of the order of 1 is achieved as can be seen from the aside plots where a voltage of 19540 V with 20 V RMS max is reported for a sample channel 20

Conclusions In LHCb a complex system in order to control and monitor the Rich Detectors was designed and implemented All the needed parameters are monitored Environmental Pressure Temperature Humidity Quality Mirror Alignment Gas Quality A new VHV Power Supply System completely automatized and remotely controlled was developed and is now working with good performances In case of simple problems the system is able to recover them restoring normal operations conditions In case of hard safety problems the system is able to interlock the detector putting it in a safe state. Rich 2007 Trieste 19.10.2007 21

Spare Slides Rich 2007 Trieste 19.10.2007 22

LHCb RICH detectors RICH2: 17-100 GeV/c RICH1: 2-60 GeV/c Rich 2007 Trieste 19.10.2007 23

Monitoring HPD enclosure: Air temperature (2 pt100). Humidity. Up to 16 temperatures (hot spots) per column (pt1000). High Voltage (6 voltages per column). Cooling pressure. Light level. Voltages and currents (from the power supplies). Temperature in RICH2 radiator: 20 pt100 in gas volume. Relative pressure (no gas yet). Rich 2007 Trieste 19.10.2007 24

Environmental Parameters Monitoring (II) RICH2 CF 4 radiator temperature Environmental Parameters PVSS II Monitoring Panel Rich 2007 Trieste 19.10.2007 25

Safety PVSS Per column: Any high column temperature will switch off the particular column. Power supplies will trip at over current. HV disable if over-current, over/under-voltage, monitoring problem. Per HPD enclosure: High ambient temperature will switch off whole side. Loss of cooling will switch off whole side. DSS Any alarm switches off whole RICH detector. Ambient temperature sensors. Chain of thermo-switches (1 per column). Rack related alarms. Light level Disables High voltage. Rich 2007 Trieste 19.10.2007 26

An embedded PC is still not a board-controller For controlling, configuring and monitoring FPGAs and ASICS need rather I 2 C, JTAG Traditional PC interfaces: PCI, ISA, parallel port, USB not very suitable for chip-control and a high-speed, simple, long distance parallel bus Need some small adapter or glue- logic The LHCb glue-card has an I2C / FPGA controller + a fast local bus generated from a PLX 9030 all controlled by an FPGA. (For details see: F. Fontanelli, B. Jost, G.Mini`, N. Neufeld, R. Abdel- Rahman, K. Rolli, M. Sannino 10 th ICALEPS Conference Geneva 2005 PO2.062) Rich 2007 Trieste 19.10.2007 27

Laser alignment monitoring system (Ib) Analysis software needs to recover centre position of reference and reflected beam with optimum accuracy and robustness. Beam not perfectly Gaussian so fitting method is not appropriate for a variety of differently shaped beams Adopt a different approach using techniques borrowed from image processing. Adopt a multi stage approach: 1. Smoothing filter 2. Edge enhancement 3. Sobel mask edge detection 4. Hough transform accumulator to determine centre of beam 5. Anomaly cut for spurious centre elimination 6. Centre spot location mask 7. Weighted average for centre determination. Rich 2007 Trieste 19.10.2007 28

Voltages Monitoring Rich Voltages Monitoring Panel Rich 2007 Trieste 19.10.2007 29