easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

Similar documents
easydetect and easydetect deluxe model train detector kits Quickar Electronics, Inc.

Installation Instructions Azatrax HexDetex Model Train Detector with Grade Crossing Trigger MRD6X

Installation Instructions Azatrax Dual Infrared Model Train Detector MRD2 'Turnout' Edition

How to modify Volvo Alarm Siren after it has given Message: Alarm system Service Required Ver. 1.2

Before you begin the installation process, gather the following tools and keep them handy:

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

TrainBoss Defect Detector Displaying Detector Model No. TB-21D

Installing and operating your Cabinet Cooling System, with Digital Thermostat

Installing and operating your Enclosed Cabinet Cooling System and digital thermostat

An Ambient-Light-Ignoring Infrared Active Motion Detector

How Home Thermostats Work by Karim Nice

MEGAbitty ProxDot Object Sensor Board (preliminary documentation) 5/1/2004

Exercise 1. Introduction to Sensors EXERCISE OBJECTIVE

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

Magneplanar 20.7 Instruction Manual

General System Layout Sketch

Sensing the World. When you have finished this lecture you should be able to:

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

SERVICE MANUAL FOR MODEL RM-10

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Polarized Retroflective Photoelectric Switches

Q1. Carefully read the following extract from a safety leaflet. Then answer the questions.

Combining Old and New Systems in Existing Buildings and Other Retrofit Tales. By Paul Jewett CFAA Technician Number 11

The diagram shows the inside of an incorrectly wired three-pin plug. What two changes need to be made so that the plug is wired correctly?

Smart Grid Tables. Exploring the Electrical Infrastructure Grades 9-12

THE. Series 01 and 02. MG01C Package

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

INSTALLATION INSTRUCTIONS GT8500E / GT8501E MASTER FLUORESCENT FIXTURE / SLAVE FLUORESCENT FIXTURE

Technical Manual. VFD / Cabinet Heater Upgrade 110 VAC Heater to 12 VDC Heater. Provided by: Chart Inc.

Installation, Operating and Maintenance Manual

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

ECOSMART TROUBLE SHOOTING GUIDE MODELS ECO POU 3.5-6

Model 3300 Technical Support and Installation Manual

AP Air Ion Counter Instructions

FLT93 Installation, Operation and Troubleshooting Guide

Smith's Heater Core DIY version

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION & OPERATION MANUAL

Run Your Trains, Not Your Track!

Always make sure to check the heating film before, during, and after installation of the floor covering.

ACCURATE ELECTRONICS INC

Alpha In-Wall Speaker 10-Inch Carbon Fiber 300W Subwoofer

EG-400 Fire Detection Monitor

Deluxe Programmable Thermostats

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

UNIT MUST BE ON A DEDICATED ELECTRICAL CIRCUIT. Owner s Manual Models: 02117/02678 INFRARED HEATER POLE SET

Amber In-wall & In-ceiling Speakers. P/Ns 24431, 24432, 24433, 24434, User's Manual

Victoreen Primalert 35 Area Radiation Monitor

Privacy Aluminum Shade

Wig-Wag (C) Light-Flashing Module Improves Aircraft Visibility

EWS-1500-T2 Deluxe Tower Heater USER MANUAL

Light Sensor Module (LSM01)

Tips To Help Conserve Electricity

Coleman Mach to Hunter Digital Thermostat Instructions

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

REV: 000. Mercury Compact Series

Helicycle Crew Alerting System (CAS)

MWS3 Ceiling Mount Microwave Occupancy Detector

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

KITCHEN INSTALLATION GUIDE

TM channel block occupancy detector for LocoNet

FerronTM. Instruction Manual A Kichler Decor ceiling fan

WD-CS. Water leak detection cable. Technical Overview. Features. Page 1. Data Sheet Ref: Issue: 5.1.

LINKABLE UNDERCABINET

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

Magneplanar 3.7i Instruction Manual

T8600D Chronotherm IV Deluxe Programmable Thermostats

EIC SOLUTIONS, INC. Thermoelectric Air conditioner installation and operation manual. FOR 1500 Btu MODEL # S

Vance Dickason s LDC6 Home Theater System #

INSTALLATION INSTRUCTIONS

Electric, Liquid Filled & Hydronic Rails Installation Wiring Controlling Your Rail Stainless Steel vs Chrome Warranty Where can they be installed?

Aria Polypropylene In-wall & In-ceiling Speakers. P/Ns 18586, 18587, 18588, 18589, User's Manual

Azatrax Quad Infrared Proximity Detector Shield for ArduinoTM Uno, Mega and compatibles

Magneplanar 1.7i Instruction Manual

Public Safety DAS Annunciator Panel

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

Part 1: Playing with Electricity

INSTALLATION INSTRUCTIONS FOR ENTRANCE CONTROL SYSTEM MODEL GL-RO-3

Merloni Elettrodomestici UK Ltd., Morley Way, Peterborough, PE2 9JB

How to reduce ChiliCube noise level by

EnvironmentalMonitoring

DSUB Collection Manual DSUB COLLECTION DSUB6F68K DSUB6F5K DSUB6F3K DSUB8F8K. DSUB Collection Installation Manual

USING ANCILLARY SIGNAL DEVICES TO IMPROVE SAFETY AT RAIL/HIGHWAY GRADE CROSSING SIGNALS

LINEAR HEAT DETECTION CABLE DURÁN-SAFE

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

1F60-22 INSTALLATION & OPERATING MANUAL SETBACK THERMOSTAT. Homeowner: Save this booklet for future use!

Developing UV LED Curing Processes for Converting Applications

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Solstice Kit Assembly Guide

CO2 Carbon Dioxide Sensor

BDL168. All Scales. LocoNet Occupancy Detector For 16 Detection Sections and up to 8 Transponder Zones

Cambridge National Engineering. Mark Scheme for January Unit R113: Electronic principles

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

DSP-13 Tri-Axis Detection (TRIAD TM ) System

an ISO 9001:2008 Registered Company GOLL ST. - SAN ANTONIO, TX ph fax MINI SPACE SAVER HEAT /COOL

Vari-Cyclone Ceiling Fans

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

Use numbers given in the box to complete the following sentences. In the UK, the mains electricity supply is volts.

Transcription:

easydetect and easydetect deluxe model train detector kits 2011-2012 Quickar Electronics, Inc. INSTRUCTIONS AND DIAGRAMS REVISED NOV 12 TH 2018 Please note that the color of the calibration trimmer may be orange or blue instead of the black pictured depending on what brand of trimmers are available Features, Set Up, Wiring Diagrams, Calibration, User Manual, and Assembly Instructions Thank you for purchasing our new detector circuit kit for model railroads. This kit can be used to provide a visual indication at your control panel of trains in hidden staging or it can also be used to turn on and off your crossing flashers at grade crossings, AS WELL AS CONTROL YOUR SWITCH MACHINES, AND CONTROL YOUR SIGNALS Features: Least expensive train detector kit available Easy To Assemble even for someone who has never built an electronic kit Small Size so you can hide it virtually anywhere Easy to install on your layout only 2 small holes needed between the rails, so it is almost invisible Uses very little power requires a 6 to 12 volt dc power supply, and uses only 10-20 milliamps 6 DIFFERENT VERSIONS STANDARD DELUXE STANDARD WITH SPDT RELAY DELUXE WITH SPDT RELAY STANDARD WITH DPDT RELAY DELUXE WITH DPDT RELAY

*******************************************************

Before we go any further let s discuss the various means of detecting a model train and their advantages versus disadvantages. 1. Current Detection. In a current detection scenario, your layout is divided into electrical blocks. When a locomotive enters that block it draws current that can be detected. This is how real railroads detect trains. Unfortunately to do this on a model railroad, more than just the first locomotive needs to draw current. This means you have to equip all or most of your cars with resistors or resistive paint between the wheels. For this reason we did not use current detection, because you would have to spend a bunch of money and time to modify all of your cars. 2. Optical Detection. This is the method our detector uses, in a very simple, inexpensive way. Our circuit uses 2 phototransistors ( or 4 phototransistors in our Deluxe Kit) to detect the ambient light on your layout. When something a loco or car covers at least one of the phototransistors, the detector circuit is activated. This is like an electronic switch that is turned on or off depending on whether it senses light or darkness. You can use our easydetect circuit to turn on a led at your control panel so you know where on your layout a train is located.useful in hidden staging yards, or to turn on and off a crossing flasher kit like the one we sell. The disadvantage to our circuit is that there must be enough light on your layout (there is a calibration adjustment you can make to adjust for most lighting levels, more on this later.) and if you are using it to turn on/off a crossing flasher, your train must be long enough that the 1st phototransistor will still be covered buy a car as your locomotive goes over the 2 nd phototransistor. Of course there are other optical detectors that either use ambient light, or infrared emitter/detectors, but they are a lot more expensive.in some cases 3 times as much! ASSEMBLING YOUR DETECTOR KIT You will need the following tools and supplies to assemble and install your detector kit:..small pencil size soldering iron with fine tip...rosin core solder

..some small diameter (24-30 gauge) wire to connect the phototransistors to the circuit board, wire to connect to your 6 12 volt DC power supply, and wires to connect to your load. Your load can be our crossing flasher kit, or an led mounted on your control panel..heat shrink tubing or electrical tape to insulate the leads of the phototransistors drill to make holes between the rails of your model railroad track for the 2 phototransistors Please look at the picture below to identify the parts, and where the parts go on the circuit board note that the phototransistors look just like 3mm leds

1. make sure the board is laying face up so that the silver lines between the holes are laying face up as shown start by placing the 2n3904 transistor thru the 3 holes in the circuit board and solder in place.please note the transistor has a rounded side and a flat side, so make sure you install the transistor the right direction as it appears in the pictures flat side facing out clip off the excess length of the transistor leads on the bottom of the board after soldering

3. place the board resistor ( 1k Ohm brown black red gold) as shown and solder in place note it does not matter which end of the resistor goes where clip off the excess length of the resistor leads on the bottom of the board after soldering

4. place the calibration trimmer in the holes as shown and solder in place

5. place color coded wires in the holes to run to the phototransistors

Before installing the detector on your layout we highly reccomend that you test it on your workbench first Apply 6-12 volts DC power to the power input wires on the kit as per the picture above If the lights are fairly bright in your layout room the red led should light up when you cover either one of the two phototransistors with your finger. If the red led does not light when you cover either one or both of the phototransistors, then while keeping at least one of the phototransistors covered, take a small screwdriver, and turn the calibration trimmer until the red led turns on start by turning the calibration trimmer a small ways to the right then cover either one or both of the phototransistors, again by turning to either the left or right

you should find a spot where the status led turns on when you cover one of the phototransistors. if you still cant get it to work, try increasing the light in you layout room maybe try a small clamp on lamp over one of the phototransistors and try adjusting the calibration trimmer again it should work. Try holding the phototransistors in your hand and move them closer or farther away from your workbench lamp(s) 6. determine how far apart you want to place the phototransistors, and trim the wires to length 7. either slip some heat shrink tubing over the ends of the wire before soldering the wires to the phototransistors, or use electrical tape to insulate the legs of the phototransistors make sure that the long leg of each phototransistor is soldered to the correct color coded wire that then goes to the correct hole on the circuit board 8. Drill holes between the rails where you want your phototransistors to detect the train and insert the phototransistors in the holes so the rounded tops are facing upwards

9. solder color coded wires in the holes as shown for power to the kit and power to control your load follow the pictures and don t get them mixed up as connecting the kit backwards could destroy the kit Calibration, Testing, and Connecting to other Circuits We supply the kit with a red led for testing and calibration purposes if all you need is to know where your train is at, you can mount this led at your control panel by using some long wires Below is the Wiring Diagram for connecting your Red Status Indicator Led that is supplied with the kit

Apply 6-12 volts DC power to the power input wires on the kit as per the picture above If the lights are fairly bright in your layout room the red led should light up when you cover either one of the two phototransistors with your finger. If the red led does not light when you cover either one or both of the phototransistors, then while keeping at least one of the phototransistors covered, take a small screwdriver, and turn the calibration trimmer until the red led turns on start by turning the calibration trimmer a small ways to the right then cover either one or both of the phototransistors, again by turning to either the left or right you should find a spot where the status led turns on when you cover one of the phototransistors. if you still cant get it to work, try increasing the light in you layout room maybe try a small clamp on lamp over one of the phototransistors and try adjusting the calibration trimmer again it should work.

Below is the wiring diagram for interfacing to our Crossing Flasher Kit ( The crossing flasher kit is not included but is for sale separately from the detector kit ) Below is the wiring diagram for interfacing to our Crossing Flasher Kit and the Red Status Indicator both at the same time

BELOW IS OUR WIRING DIAGRAM FOR INTERFACING OUR DETECTOR KITS TO A 12 VOLT DC RELAY Pictured below is a wiring diagram for interfacing with a generic 12 volt DC relay Things to bear in mind when interfacing to a relay 1. Relay Selection: your relay must be a relay whose coil will operate reliably with 12 volts dc and 20 milliamps or less of power 2. Your power supply for you load should not exceed the relays contact rating

Pictured below is a wiring diagram showing how to interface with the 12 volt relay we sell in our Detector with Relay Kit Things to bear in mind when interfacing to a relay 3. Relay Selection: your relay must be a relay whose coil will operate reliably with 12 volts dc and 20 milliamps or less of power 4. Your power supply for you load should not exceed the relays contact rating see the pictures below for proper placing of your phototransistors and extra lighting options if your layout room has dim lighting CONGRATULATIONS - That s it.you are done. Troubleshooting

If the red led does not come on regardless of which way or how far you turn the calibration trimmer then check the following 1. are the phototransistors wired correctly so that the long leg of each phototransistor is connected to the correct wire that goes to the correct hole? 2. check to see that all your soldering connections are nice and strong 3. check to see that the 2n3904 transistor is installed facing the right direction 4. check to see that you have the positive and negative wires that power the kit are connected correctly to you 6-12 volt dc power source 5. MAKE SURE YOUR POWER SUPPLY IS DC NOT AC 6. check to see that your 6-12 volt power supply is turned on you can check that by connecting the red led/ 560 ohm resistor combination directly to your 6-12 volt dc power supply make sure the 560 ohm resistor is soldered to one leg of the led or it could blow up the led 7. check to see that the red led is wired correctly, if it is backwards, it wont hurt the kit, but it wont light up either 8. the detector will not work if you turn the lights off in your layout room or if the lights are not bright enough. One way around this would be to install light posts on your layout above the phototransistors see diagram below 9. Remember that at least one of the phototransistors need to be covered for the detector circuit to be activated. If your train is too short, you could have a situation where the detector comes on when the engine covers the first phototransistor, but shuts off before the train reaches the crossing because the 1st phototransistor gets uncovered before the 2 nd phototransistor gets covered

Thanks again for purchasing our new train detector kit If you have any questions or problems please call us at 503-377-8247 or email sales@quickar.com see illustration below for proper spacing of your phototransistors and for wiring the phototransistors in our Deluxe 4 Point Detector kit

As shown in the above pictures, Please note that as long as at least one of the phototransistors is covered the detector is still activated, so if the train stops and backs up, as long as at least one phototransistor is covered, the detector will work. Things to remember before buying or installing your detector kit so your detector kit works properly 10. the detector will not work if you turn the lights off in your layout room or if the lights are not bright enough. One way around this would be to install light posts on your layout above the phototransistors see diagram below

Things to remember before buying or installing your detector kit so your detector kit works properly 11. Remember that at least one of the phototransistors need to be covered for the detector circuit to be activated. If your train is too short, you could have a situation where the detector comes on when the engine covers the first phototransistor, but shuts off before the train reaches the crossing because the 1st phototransistor gets uncovered before the 2 nd phototransistor gets covered. See picture below The remedy is to either move the two phototransistors closer together, or use a longer train or you can purchase our Deluxe Detector Kit that features 2 extra phototransistors for a total of 4 detection points See Wiring Diagram Below for wiring the

4 phototransistors in our Deluxe Detector Kit

Thanks again for purchasing our new train detector kit If you have any questions or problems please call us at 503-377-8247 or email sales@quickar.com Revisions 10/30/2018 COMMON QUESTIONS (and answers) QUESTION: What does it take to power the detector kit(s)? ANSWER: 12 volt DC power supply one that is separate from your power to the train tracks QUESTION: how much power does the detector kits output? ANSWER: 12 VOLTS DC @ 20 MILLIAMPS QUESTION: can you use a deluxe (4 point) detector kit to cover a double crossing? ANSWER: YES 2 detection points on either side of each crossing track QUESTION: Can I add more than 4 detection points? ANSWER: NO.4 detection points is the maximum per detector kit QUESTION: What is the optional relay for?

ANSWER.So you can power any crossing signal or other device that needs more than 12 volts DC at more than 20 milliamps with the optional relay and a separate power supply..you can use the detector kit to turn on and off ANY brand crossing flasher or other device.ac OR DC and up to 10 amps QUESTION: Do I need the relay? ANSWER: Only if the device (crossing flasher or other) you are powering with the detector kit needs more than 20 milliamps at 12 Volts DC QUESTION: I don t have a crossing flasher yet what should I get? ANSWER: Our crossing flasher works perfectly with ANY of o9ur detector kits no relay needed QUESTION: I still have other questions what should I do? ANSWER: Call us at 503-801-8408 10am to 6pm Mon-Fri Pacific Time New circuit diagrams

WITH BIPOLAR LED

WITH BIPOLAR LEDS ON EITHER SIDE OF THE CROSSING