CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

Similar documents
CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Retro Fit Rinse Pump Rev B

Sprite III Warewash Dispensing System

D3000. Installation & Setup Guide

User Manual GV25 GV35 GV702. Company information: Original instructions GV12066 (1)

SPRITE Warewash Dispensing System

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

MINI FOOD CHOPPER INSTRUCTIONS FOR USE. Thank you for purchasing this product. Please read these instructions carefully before use

PORTABLE AIR CONDITIONER (LOCAL)

MHG201 Gas Hob Manual for Installation, Use and Maintenance

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

24 & 30 INCH DRUM FANS

READ AND SAVE THESE INSTRUCTIONS

Tempest TP420/180 Electric Pressure Washer

PORTABLE AIR CONDITIONER (LOCAL)

systems europe Laundry & Warewash Product Catalogue

24 & 30 Drum Fan. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

CRU-S Series Stainless Steel Condensate Recovery Unit

DESIGNED FOR HEAVY DUTY, OUTDOOR CLEANING

EDD61 & EDD91 Extractors

DEMA 830 Laundry Master TM Installation Instructions

Professional HEPA Air Cleaner

EVP61/91/101/121. Extractor. Installation, use and maintenance.

AC6 & AC8 HORIZONTAL SERIES Sealed Metallic Centrifugal Pumps Installation and Maintenance Instructions

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

NON-SUBMERSIBLE WATER PUMP

LOCAL AIR CONDITIONER

CPE RANGE PUMPS CPE RANGE PUMPS. MODEL Nos: CPE15A1 15A3 20A1 20A3 30A1 30A3 PART Nos:

Operator s Manual. IP-100 Immersion Probe Cooler

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY INFRARED HEATED SEAT MASSAGER MODEL C90005

Operating Instructions

Owner & Operator s Manual. Table of Contents

COMPACT AND LIGHTWEIGHT FOR OUTDOOR CLEANING

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

MODEL 7000 SUCTION UNIT

INSTALLATION INSTRUCTIONS: these are intended for the qualified technician who must carry out the installation, hook-up and testing of the appliance.

EVG Extractors. Manual for Installation, Use and Maintenance

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

Vintage Desk Fan. Model: SF1010 (all colours) Helpline. v1.1

OPERATING INSTRUCTIONS

User Manual. Dishwasher ZDM17301SA ZDM17301WA

Sanitise Syrup Lines & Valves. Taylor PH61 Cleaning every 14 days

30-pint Dehumidifier User Guide

Bagless upright. Vax Careline (UK) (ROI) vax.co.uk VS-19EC. Vax model number:

! WARNING. Before using product, read and understand instructions.

DEHUMIDIFIER. User Manual 50BT, 70BT

OWNER S GUIDE S3501UKL

User and maintenance manual

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Pet. Easy Guide. VAX Ltd., Kingswood Road, Hampton Lovett, Droitwich, Worcestershire, WR9 OQH, UK - website:

FORMATIC Instruction Manual

CTE9. Extractor. Installation, use and maintenance.

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE BOOKLET PROGRAMME CHART

CONTENTS READ INSTRUCTIONS FOR USE! INSTRUCTIONS FOR USE

VAC-THEN-STEAM MV2010UKL OWNER S GUIDE

1300W Pressure Washer RACHP133A

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

HOT 2000 USER MANUAL. Version 3.1. This manual shall be read in its entirety before using the machine.

Hedge Trimmer. Please read the manual fully before using the appliance and keep the manual safe for future reference.

Bar Fridge USER MANUAL MB46W

INSTALLATION & OPERATION Rev 1.00A DISTRIBUTED EXCLUSIVELY BY CMA DISHMACHINES KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841

TH100 Three in One Instant Hot Water Tap

CONSTANT SUCTION UNIT

DV7215EL DV1015EL DV1415EL DV1815EL.

POWERSHRED 325Ci/325i

Installation and Operating Instructions DÜRR Regeneration Unit for X-ray developers XR 24, XR24 II, XR 24 Nova, XR 24 Pro

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

HOT WASHER MODEL NO: KING150

OPERATING INSTRUCTIONS

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

A few simple steps to ensure perfect water, every time.

CELSI ELECTRIFLAME XD

Rapide Deluxe PT. User Guide V-026PTS. Performance is everything. vax.co.uk

Operating Instructions

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

SWIMMING POOL & SPA HEAT PUMPS OWNERS OPERATIONAL MANUAL

ProAction. Paper Shredder. Installation & User Instructions Please keep for future reference 903/1537

Instructions for installation and use English. More documents on: H B /09

HOT 4000 USER MANUAL. Version 2.1. This manual shall be read in its entirety before using the machine.

Automatic Water System Pump SERIES

AirTM SERIES POWERFUL LIGHTWEIGHT FULL SIZE LET S GET STARTED. CCQSAV1P1 CCQSAV1T1 CCQSAV1C1 CCQSASV1P1 CCQSASV1T1 CCQSASV1C1

4L Instant Water Boiler Instructions for Use

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

One-Touch Dispense. Multi-temp selections. 208 F For tea, coffee, instant noodle. 194 F Keep warm around 194 F. 176 F Keep warm around 176 F.

40cm Pedestal Fan with Remote Control

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

User Guide. Fixed Flow Pumps FOR SUBMERSIBLE OR INLINE USE FOR PUMP MODELS # # # # # # # # #728333

EZA60BL & EZA90BL Extractors

ST1. Mod. USE AND MAINTENANCE MANUAL

OPERATING INSTRUCTIONS

Get Cleaning... What s your Vax s model number? User Guide. Carpet Washer Vax Careline: AU: NZ:

St eam Cleane r. User Guide. Stick Steam Cleaner. Get Cleaning... vax.co.uk. S87-CX series

HOT AIR GUN MODEL NO: CHG1500D USER INSTRUCTIONS PART NO: GC0414

Personal Blender User guide

BEFORE USING THE DISHWASHER/CONNECTIONS

Wax Base Heater & Dispenser

Installation & Operating Guide

DLC Instruction Manual. Light Curing Machine MODEL. Table of Contents

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

Transcription:

CP-200 - Warewash Pump Instruction & Operation Manual Push Button 20-08881-01, Rev1.0, 25.06.2012, Page 1 of 8

Contents A) Description B) Site Survey and Installation Requirements C) Package Contents D) Installation E) Maintenance: Changing the Pump Tubing Inspecting the Pump Installing the New Tubing F) Specification G) Troubleshooting H) Replacement Parts I) Safety J) WEEE - Waste Electrical and Electronic Equipment K) EC Declaration of Conformity 20-08881-01, Rev1.0, 25.06.2012, Page 2 of 8

A - Description The CP-200 P/B dispenses liquid chemicals with a high degree of accuracy and repeatability. A separately wired push-button provides a convenient way to start the cycle. Simple mounting, setup and low cost make it ideal for single product applications. Two front potentiometers control Pump Run Time (1 second - 3 minutes) and Delay Time (0-3 minutes). The rearlocated potentiometer can be used to set a Lockout period (0-30 minutes) that temporarily disables the push-button after the initial press and prevents accidental re-dosing during a wash cycle. A constant, green LED indicates power to the pump. A flashing green LED indicates that a delay or a lockout period is in progress. B - Site Survey and Installation Requirements Before an installation takes place it is advisable to complete a site survey to ensure the CP-200 can be installed in a position that meets all of the requirements listed below. a) Unit must not be installed near areas that suffer excess temperature changes, direct sunlight, frost or precipitation of any kind b) Ensure the unit can be mounted in an accessible position above the height of the required discharge location. c) Unit must be mounted on a suitable wall, that is flat and perpendicular to the floor d) Area unit works in must be well lit for maintenance e) Install the CP-200 P/B close to product containers 2 m (6.5 ft.) and away from direct sources of steam, water spray, and high temperatures. f) The CP-200 P/B should be installed by a qualified technician only, in accordance with all applicable electrical and plumbing codes. g) Tube life will vary depending on the type of treatment product used. Advise scheduled maintenance and tube replacement at least once per year. C - Package Contents CP-200 P/B Pump Wall Mount Kit Push Button D - Installation Step 1 - Set Lockout Timer Set the Lockout Timer (on back of unit) to temporarily disable the pushbutton after the initial press and prevent accidental re-dosing during a wash cycle. The lockout period can be adjusted whenever the CP-200 P/B is not in a current dispensing cycle (which includes any lockout period). The new setting goes into effect in the next dispensing cycle. To set Lockout Timer to OFF: Use a small flat bladed screwdriver to turn setting fully counter-clockwise (to 1). To set Lockout Timer to ON (up to 30 minutes): Turn setting clockwise to increase time. To achieve the 30 minute maximum, turn fully clockwise (to 2). To terminate an in-progress lockout period, turn power off, then restore power to the CP-200 P/B. Cycling the power on and off permits the Lockout Timer to be immediately adjusted and/or allows the pump to accept the next pushbutton start signal. 20-08881-01, Rev1.0, 25.06.2012, Page 3 of 8

Step 2 : Wall Mount Dispenser and Push-Button Install the CP-200 P/B close to product containers 2 m (6ft) and away from direct sources of steam, water spray, and high temperatures. 1. Attach mounting bracket to solid surface 2. Slide CP-200 P/B down onto bracket and press firmly to lock in place. 3. Mount push-button on a clean and dry surface using adhesion backing (provided). Step 3 : Install Supply and Discharge Tubing Supply Tubing 1. Cut tubing and route from product container to intake (left) pump tube. Slip tubing through compression nut into fitting and tighten. 2. Place other end of tubing in product container. Discharge Tubing 1. Cut tubing and route from discharge location to outflow (right) pump tube. 2. Slip tubing through compression nut into fitting & tighten Step 4 - Electrical Installation Connect 2-conductor power cable only to a properly fused power source that matches the voltage on the dispenser and on the power cable label (see wiring chart & diagram). The CP-200 P/B should be installed by a qualified technician only, in accordance with all applicable electrical codes. Step 6 Dose Adjustments Pump Run Time Left Side Potentiometer Use a small, flat-blade screwdriver to turn the left setting fully counter-clockwise to set the pump run time to the minimum (1 second = 0.1 oz / 3 ml.). Turn the setting clockwise to increase the pump run time, up to the maximum of three (3) minutes when fully clockwise. The maximum output for three minutes is 18 oz. (532 ml.) when using standard tubing. To confirm output, run dispenser, catch product in a measured container and adjust setting, as necessary. 20-08881-01, Rev1.0, 25.06.2012, Page 4 of 8

Pump Delay Time Right Side Potentiometer Turn the right setting fully counter-clockwise to begin dispensing immediately after the button is pressed (Delay is Off ). Turn the setting clockwise to set a delay time, up to a maximum of three (3) minutes when fully clockwise. E - Maintenance: BEFORE ANY MAINTENANCE, ISOLATE THE UNIT! Clean and dry the outside of the unit pre maintenance, all maintenance must be carried out by a trained technician. Allow for motor to cool after isolation Changing the Pump Tubing NOTE: You may want to work over a mat to protect floors or other areas from the possibility of spilled treatments. Remove the Old Tubing a. Loosen and remove tubing from compression fittings. b. Loosen screw on pump cover and remove. c. Remove the old squeeze tube assembly from pump housing and discard it. Inspect the Pump a. While the pump is disassembled, inspect all parts for foreign matter. b. Clean the parts as necessary. c. Check the rollers to ensure they turn freely. d. Inspect the rotor. CAUTION - If the rotor needs service, replace the entire rotor. Install the New Tubing a. Replace the rotor and put a small amount of tube lubricant on each end of the rotor assembly shaft (bearings). b. Position the pump inlet port as shown. c. Bend the new tube in half and insert without twisting the tube and place the outlet port fitting in as shown. d. Replace the rotor over the motor (blade) shaft and use a screwdriver to twist the rotor as it is inserted. e. Replace cover and tighten screw. f. Reattach the inlet and exit port tubing. g. Prime the product to ensure the fittings are tight and unit is ready for operation. NOTE: A small amount of tube lubricant in will aid this process. CAUTION - Be sure the tube is not twisted during installation. Twisting the tube will greatly reduce tube life. 20-08881-01, Rev1.0, 25.06.2012, Page 5 of 8

F - Specification Pump Flow Rate 6 oz. (177 ml.) / minute with standard Detergent tube Tube Material EPDM (Other options available by contacting Hydro Systems Europe) Power Rating 200-240VAC nominal (+/- 10%), 50/60 Hz, 0.1 amp. Duty Cycle 50%, three minute maximum run time Run Time 0.1 3 Minutes Environmental and Install Properties IP IP Rating : 44 Size (mm) 76W x 114H x 114D Temperature 10 to 49 C (50 to 120 F) maximum Humidity 95% relative humidity, maximum Installation Location Approved for indoor use only. Must not be installed outdoors. G - Troubleshooting Unit is not to be used in an ATEX environment, or with ATEX chemicals. Issue If the motor is turning If the motor won t turn Check level of chemical Ensure programmer is functioning: Try to run pump manually Check for air leaks in the supply tubing connection to pump tube. Check settings: ensure conditions for dispense are correct. Check for clogs in inlet and outlet Check power supply. Unit is not tubes. pumping Ensure pump tube is not twisted. Check light tube for glowing light fluid: Unit is pumping improperly: H - Replacement Parts Check pump tube (as it wears Replace tube binding rotor. out, the amount of fluid pumped decreases); change if necessary. Are springs broken on rotor? Check the dispense amount and adjust as necessary. Ensure unit is turning on and off at set times. Check for improper tube installation. Replace tubing with proper size. Item Part Number Part Description EPDM Pump Tube, 1/4 13-06395-10 1 Rinse 10-pk. 13-06399-10 EPDM Pump Tube, 1/4 Detergent 10-pk. 2 13-08706-06 Pump Cover, Teal (screw included) 3 13-06396-00 Pump Spinner 4 13-08596-0203 Adjustment Cover, 3- pk. Not 13-08721-01 Pump Motor Kit (Det) Shown 13-08954-00 Push Button Kit 20-08881-01, Rev1.0, 25.06.2012, Page 6 of 8

I - Safety Please use this equipment carefully and observe all warnings and cautions. Wear PPE when dispensing chemicals or other materials or when working in the vicinity of all chemicals, filling or emptying equipment. Always observe safety and handling instructions of the chemical manufacturers. Always direct discharge away from you or other persons or into approved containers. Always dispense cleaners and chemicals in accordance with manufacturer's instructions. Always exercise caution when maintaining your equipment. Always re-assemble equipment according to instruction procedures. Be sure all components are firmly screwed or latched into position. Keep equipment clean to maintain proper operation. You must follow all precautions as advised on the product safety data sheet Before any maintenance, isolate the unit Do not operate the unit without Pump Cover and Captive Screw secured in place J - WEEE - Waste Electrical and Electronic Equipment WEEE Regulations apply to companies who Manufacture & Distribute electrical or electronic equipment WEEE Classification 10. Automatic dispensers. The WEEE Regulations apply to importers, producers, retailers and users of EEE, and to businesses that treat or recover WEEE. The CP-200 unit is a product placed onto market POST 13.08.05, therefore called future WEEE. As a producer Hydro Systems Europe have the option to take responsibility for the EEE placed on the market. If Hydro Systems Europe chooses to receive WEEE they must make sure that it is disposed of in an environmentally sound way, including the treatment, reuse, recovery and recycling of the components where appropriate. Responsibility as a producer of EEE Hydro Systems Europe as a producer of EEE are registered with a producer compliance scheme who register them with the relevant environmental regulator. Through the regulator they become part of an approved producer compliance scheme (PCS).The PCS supply a unique and permanent producer registration number. If disposal is outsourced it (the product) must be taken to an appropriately licensed site (approved authorised treatment facility - AATF) where it can be treated safely. 20-08881-01, Rev1.0, 25.06.2012, Page 7 of 8

The environmental impacts of the substances in EEE and waste electrical and electronic equipment (WEEE) The main environmental concerns in the EEE sector stem from soil and water contamination, resource depletion, energy use and waste. At the production stage, obtaining raw material for EEE production consumes a large amount of energy, especially the process of extracting resources, which can also lead to degradation of the surrounding environment. For instance, when raw material is shipped to a plant, it goes through a complex, high energy-consuming process as it is converted into a finished product. Moreover, as demand for fuel and raw materials increases with the increase in exports, the environmental impact of these factors is also likely to increase. The reasons for separating WEEE from other waste Failing to separate waste properly can be very expensive as the majority of discarded products are shredded into small pieces of material and re-sold as raw material much of which ends up in the Far East and goes back into manufacturing. If the hazardous components were not separated first the entire batch could be contaminated. This significantly increases the risk of environmental damage and could lead to legal action under hazardous waste regulations. The meaning of the crossed out wheeled bin symbol The crossed out wheeled bin symbol is not intended to indicate to you that WEEE is banned from being disposed of as general waste. Moreover, the intention behind the symbol is that, when coupled with information supplied by distributors as to the availability of recycling facilities, you will be reminded that these facilities exist. How they can safely dispose of WEEE for proper treatment When the product is at its end of life, either contact the Local Authority in charge of electrical disposal, or contact Hydro Systems Europe who will either take the item back from yourself or supply you with relevant information for a local WEEE treatment facility. If asked, Hydro Systems Europe must provide yourself business with: Contact information for the EEE producer within Hydro Systems Europe. The producer s compliance scheme is responsible for the end-of-life handling of EEE. Records that will help producers to supply their producer compliance scheme with accurate information, for example numbers of sales of EEE to non-household users. As a distributor Hydro Systems Europe have no legal obligation to take back WEEE from business users K - EC Declaration of Conformity This unit complies with the following directives; Electromagnetic Compatibility (EMC) Directive (2004/108/EC) Machinery Directive - (2006/42/EC) And has been designed and manufactured to the following specifications EN ISO 12100, EN 61000-6-1, EN 61000-6-3, EN 61000-3-2, EN 61000-3-3 12 Hydro Systems Europe Ltd Unit 3, The Sterling Centre Bracknell Berkshire RG12 2PW 20-08881-01, Rev1.0, 25.06.2012, Page 8 of 8