INSTALLATION MANUAL. Decoration Panel Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ140D7GW1 BYCQ140D7GFW1

Similar documents
Self Cleaning decoration panel

INSTALLATION MANUAL. Decoration Panel BYCP125K-W1 MODELS

General safety precautions English

General safety precautions English

General safety precautions English

DAIKIN ROOM AIR CONDITIONER. Operation Manual

INSTALLATION MANUAL. Decoration panel BYCQ140D7W1 BYCQ140D7W1W

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXSQ36MVJU FXMQ36MVJU FXSQ48MVJU. MODELS Ceiling-mounted Duct type. Ceiling-mounted Built-in type

General safety precautions English

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

SYSTEM Inverter Air Conditioners

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

General safety precautions English

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

OPERATION MANUAL. Split series room air conditioners Multi system room air conditioners FDBQ25B7V1

INSTALLATION MANUAL. Decoration panel BYFQ60C3W1W BYFQ60C3W1S MODELS

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

INDOOR UNIT/OUTDOOR UNIT

SYSTEM Inverter Air Conditioners

General safety precautions English

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

INDOOR UNIT/OUTDOOR UNIT

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

INDOOR UNIT/OUTDOOR UNIT

OPERATION MANUAL. SYSTEM Inverter Air Conditioners FXAQ15PAV1 FXAQ20PAV1 FXAQ25PAV1 FXAQ32PAV1 FXAQ40PAV1 FXAQ50PAV1 FXAQ63PAV1

INDOOR UNIT/OUTDOOR UNIT

INDOOR UNIT/OUTDOOR UNIT

SPLIT TYPE. Instruction manual

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

INDOOR UNIT/OUTDOOR UNIT

Moveable Air-conditioner User s Manual

INDOOR UNIT/OUTDOOR UNIT

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

SYSTEM Inverter Air Conditioners

Instruction Manual. Portable Air Conditioner

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Installation. Leveling

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

Installation and operation manual

OPERATION MANUAL. Wireless Remote Controller Kit

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

WINDOW TYPE COOLING MODEL AKT7F AKT9F REVERSE CYCLE MODEL AKT7U AKT9U FUJITSU GENERAL LIMITED

53 KNL / 53 QNL OWNER S MANUAL

Handling or using the product improperly and in disregard of the instructions with this mark might result in serious bodily injury or death.

OPERATION MANUAL. System air conditioners FXAQ15AUV1B FXAQ20AUV1B FXAQ25AUV1B FXAQ32AUV1B FXAQ40AUV1B FXAQ50AUV1B FXAQ63AUV1B

Inverter Split-type Room Air Conditioner

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

900mm Island Canopy Manual

INSTALLATION MANUAL. R410A Split Series. Models RXS15LVJU RXS18LVJU. Installation manual R410A Split series. Manuel dinstallation Série split R410A

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

INSTALLATION MANUAL MODELS DAIKIN ROOM AIR CONDITIONER. R410A Split Series. Installation manual Manuel d installation Manual de instalación

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

INDOOR UNIT/OUTDOOR UNIT

D14 & D18 Upright Vacuum

Wireless Remote Controller Kit

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Operation Manual - PC-ARF - P IMPORTANT:

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

FDT11 FDT15 FDT18. DUCTED TYPE SPLIT SYSTEMS (3 Phase, Fixed Speed)

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

GDDEM10 DEHUMIDIFIER

Dehumidifier. Instruction Manual. Model DH-320/A

DAIKIN AIR CONDITIONER

Portable Air-conditioner Use and Care Manual

ISHIDA CO., LTD. Do not carry out installation, operation, service or maintenance until thoroughly understanding the contents of this manual.

MXZ-4B80VA MXZ-5B100VA INSTALLATION MANUAL

INSTALLATION MANUAL R410A Split Series

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

Operation Manual MODELS FTYN25DV3B FTN25DV3B FTYN35DV3B FTN35DV3B FTYN25DAV3B FTN25DAV3B FTYN35DAV3B FTN35DAV3B DAIKIN ROOM AIR CONDITIONER.

Using the Remote Control Unit

1. BEFORE INSTALLATION

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

51AKS I S O OWNER S MANUAL

50 Disassembly and assembly Cab and its attachments

Split-type Air-Conditioner

Indoor Unit (2 Series)

RAS-M10U2MUVG-E RAS-M13U2MUVG-E RAS-M16U2MUVG-E

INSTRUCTION MANUAL EPH-121 CONTENTS

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Portable Air-conditioner

Service Manual & Installation Manual

Washing Machine. User manual WW9*K5*****/WW8*K5*****/WW7*K5***** Untitled :17:40

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

CONTENTS READ BEFORE OPERATION

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

BL Series INSTRUCTIONS

Installation Instructions

Transcription:

INSTALLATION MANUAL Decoration Provided with Filter Auto Cleaning Function Self Cleaning decoration panel BYCQ0D7GW BYCQ0D7GFW

BYCQ0D7GW BYCQ0D7GFW Installation manual Contents. SAFETY PRECAUTIONS.... ACCESSORY.... INSTALLATION SITE.... PREPARATIONS FOR PANEL... 5. PREPARATIONS FOR INDOOR UNIT... 6. ATTACHING PANEL TO INDOOR UNIT...5 7. ATTACHING SUCTION GRILLE AND DECORATION CORNER COVERS...8 8. OPERATION MODE SETTINGS...0 9. FIELD SETTINGS...0 0. TEST OPERATION... The English text is the original instruction. Other languages are translations of the original instructions.. Safety precautions Please read these "Safety precautions" carefully before installing air conditioning equipment and be sure to install it correctly. After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate the air conditioner and take care of it with the aid of the operation manual. Ask the customer to store the installation manual along with the operation manual for future reference. This air conditioner comes under the term "appliances not accessible to the general public". Meaning of WARNING and CAUTION notices. Installation manual WARNING CAUTION WARNING Failure to follow these instructions properly may result in personal injury or loss of life. Failure to observe these instructions properly may result in property damage or personal injury, which may be serious depending on the circumstances. Ask your dealer or qualified personnel to carry out installation work. Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire. Perform installation work in accordance with the instructions in this installation manual. Do not modify the product. Improper installation may result in water leakage, electric shocks, or fire. Be sure to use only the specified accessories and parts for installation work. Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire. Make sure that specified wires are used and that there is no strain on the terminal connections or wires. Improper connections or securing of wires may result in abnormal heat radiation or fire. Be sure to switch off the unit before touching any electrical parts. Arrange the lead wires of the provided harness so that the EL. COMPO. BOX lid of the indoor unit will not rise, and attach the lid securely. Heat radiation, electric shocks, or fire may result if the EL. COMPO. BOX lid is not attached properly. Tear up and dispose of the plastic bag. Children playing with the plastic bag may be suffocated. CAUTION Install the indoor and outdoor units, power cord, remote controller wiring, and transmission wiring at least m away from TV or radio sets. This is for the prevention of TV and radio interference. (Depending on the incoming signal strength, a distance of meter may not be sufficient to eliminate noise.) Pay the utmost attention to the transportation of the product. Hold the handles on the package to carry the product. Do not carry the package with the polypropylene band on the package held, which will be dangerous because the polypropylene band may be deformed. Do not touch the fin of the heat exchanger. Touching the fin improperly may result in injury. Do not turn the product power off immediately after the operation of the product comes to a stop. Always wait for at least 5 minutes before turning the product power off. Otherwise, water leakage and malfunctions may result. Do not install the air conditioner in the following locations:. Where there is a high concentration of mineral oil spray or vapour (e.g. a kitchen). Plastic parts will deteriorate, parts may fall off and water leakage could result.. Where corrosive gas, such as sulphurous acid gas, is produced. Corroding of copper pipes or soldered parts may result in refrigerant leakage.. Near machinery emitting electromagnetic radiation. Electromagnetic radiation may disturb the operation of the control system and result in a malfunction of the unit.. Where flammable gas may leak, where there is carbon fibre or ignitable dust suspensions in the air, or where volatile flammables such as paint thinner or gasoline are handled. Operating the unit in such conditions may result in fire. [Instructions peculiar to this product] Do not install the product in the following places. Oil, cigarette tar, and steam will result in sticky dust on the filter, which may not be cleaned properly. Furthermore, sticky dust may cause malfunctions. Places with oily smoke: Restaurants, factories, etc. Places with excessive cigarette smoke: Smoking room, etc. Places with excessive moisture or steam: Restaurants, factories, etc. The air conditioner is not intended for use in a potentially explosive atmosphere. Have the customer actually operate the air conditioner while referring to the operation manual and explain the right operation of the air conditioner with useful tips given. Refer to the operation manual along with the installation manual provided with the indoor unit. Use the BRCE5A7 remote controller.. Accessory Check that the following accessories provided with the air conditioner are correct in number. See the following illustration, which shows where the accessories are kept. Backside of the protective corrugated cardboard A set of accessories The accessories are on the backside of the protective corrugated cardboard under the suction grille. BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

Spacer Flexible S-shaped Clamp Name () hose () pipe () Harness () (5) Quantity pc. pc. pc. pc. pc. Shape Connecting Attachment Name pipe (6) (7) Seal (8) Quantity pc. pc. pc. Shape Pay the utmost attention to the following items when conducting installation work, and recheck the items on completion of the work. a. Test items on completion of work Others Operation manual Installation manual Test items In case of failure Result Is the air conditioner free of wiring and connection mistakes or omissions? Are you sure that there is no space between the ceiling and ceiling material? Are the fixing knobs (in two points) of the dust box secured tightly? Are the fixed knobs (in five points) of the air filter secured tightly? Is the fall prevention cord for the dust box and grille hooked to the mounting bracket? Did you attach the EL. COMPO. BOX lid, dust box, flexible hose, S-shaped pipe, suction grille, and decoration corner covers? Operation failure and wire burnout Water leakage Vibration, noise, and dust collection failure Vibration, noise, and dust collection failure Fall Noise and dust collection failure * Be sure to recheck the items provided in the section ". Safety precautions" on page. b. Test items before delivery Test items Was the test operation of the air conditioner finished? Did you explain the operation method of the air conditioner to the customer while showing the customer the operation manual? * Did you make mode settings for filter auto cleaning (automatic control operation settings or timer operation settings with an operation time zone specified) and provide information on the set mode operation of the air conditioner to the customer? Did you deliver the operation manual to the customer? (Be sure to hand the customer the operation manual as well as the installation manual.) Did you hand the customer the connecting pipe and attachment and ask the customer to keep them? Result * Point of operation explanation In addition to the general usage of the air conditioner, it is necessary to explain the descriptions of the WARNING and CAUTION marked items in the operation manual and have the customer read the descriptions carefully, because these items indicate information that, if not heeded, is likely to result in loss of life, serious injury, or property damage.. Installation site This product offers selectable air outlet directions. A closure kit (an optional accessory) is required to achieve three-way flow patterns. Two-way flow patterns are not available to this product. - Select the installation site that meets the following conditions with the consent of the customer The surface of the ceiling is not remarkably inclined. Installation and service workspace is secured (see the following illustrations). The panel indicators are seen with ease. The indoor and outdoor units, power cord, transmission wiring, and remote controller wiring are at least m away from TV or radio sets. (The above is for the prevention of TV and radio interference. Depending on the incoming signal strength, a distance of meter may not be sufficient to eliminate noise.) - Required installation space Install the indoor unit according to the installation manual and the following illustrations. Dust collection inlet Indicator Front side of panel 56 0 0 Indoor unit Drain socket At least 500 mm away from the wall. This space will be at least 500 mm with the air outlet closed and blocking pad installed. Dust collection inlet 5 A space is required for dust collection with a vacuum cleaner used - Mounting directions of suction grille Select one of the following mounting directions of the suction grille on the panel. Drain socket Piping Dust collection inlet Drain socket 5 Piping Suction grille BYCQ0D7GW + BYCQ0D7GFW Installation manual P0-B 05.05

. Preparations for panel - Removal of decoration corner covers Decoration corner cover Perform all the required work in ". Preparations for panel" on page with the panel kept in the packing material (on the bottom side). Do not put the panel downward or upright or leave the panel on protruding parts. Otherwise, scratch damage to the surface of the panel may result. Do not touch the swing flap and do not put any force on the swing flap. This will result in malfunction of the unit. - Removal of suction grille from panel, protective corrugated cardboard, and set of accessories Decoration corner cover Decoration corner cover () Raise and remove the decoration corner cover (with the display) in the direction of the arrow. Do not impose force on the lead wires. () Press the knobs of the suction grille and lift up the knobs. Decoration corner cover (with display) Operation/filter cleaning Packing material (bottom) Decoration panel Knobs () Open the suction grille to an angle of approximately 5 and remove the suction grille from the panel. 5 () Remove the screws on the backside of the decoration corner cover (with the display), open the cover, and remove the connector attached to the front end of the lead wires from the PCB. Cover Connector Screw Lead wires Decoration corner cover (with display) PCB () Take out the protective corrugated cardboard. Take out the protective corrugated cardboard (on top of the panel) together with the accessories attached to the backside of the protective corrugated cardboard. () Remove each of the remaining decoration corner covers (i.e., three covers) in the direction of the arrow. Decoration corner cover Protective corrugated cardboard (top) (The accessories are on the backside.) Protective corrugated cardboard (bottom) - Removal of dust box Do not impose force on the swing flap, brush unit, or air filter when handling the panel. Air filter Fixing knob of dust box and clasp Dust box Fixing knob of dust box Brush unit Swing flap Installation manual BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

() Turn the two fixing knobs of the dust box. 5- Attaching spacer (accessory ()) Fixing knob Dust box () Remove the bypass hole closing cap. Fixing knob (The front side of the panel is shown for ease of explanation.) () Remove the dust box from the panel while paying attention not to cut the fall prevention cord. Dust box Fall prevention cord Indoor unit Remove the bypass hole closing cap () Peel off the release paper of the double-stick tape on the backside of the spacer (accessory ()). () Attach the spacer (accessory ()) on the air bypass hole. Check that the air bypass hole is not blocked after the spacer is attached. () Remove the fall prevention cord for the dust box from the clasp bracket of the panel. Remove the fall prevention cord from the clasp bracket. Dust box Clasp Fall prevention cord Air bypass hole Pasted to align with the air bypass hole Align the corners Spacer (accessory ()) 5- Attaching harness (accessory ()) () Remove the EL. COMPO. BOX lid from the indoor unit. Claws 5. Preparations for indoor unit WARNING Check that the indoor and outdoor units are turned power off before conducting wiring work. Otherwise, an electric shock may be received. Screws ( points) EL. COMPO. BOX lid Loosen the screws (in two points) and slide the EL. COMPO. BOX lid in the direction of the arrow to unhook the lid from the claws. CAUTION Conduct the following work after installing the indoor unit. Install the indoor unit according to the installation manual provided with the indoor unit. BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05 Installation manual

() Remove jumper connector from X8A. () Tentatively put the two temporary latching brackets of the suction port of the panel (on the internal circumference side) to the hooks of the indoor unit. X8A Leave your hands after confirming through the check window that the temporary latching brackets are engaged with the hooks. EL. COMPO. BOX Jumper connector () Connect the harness (accessory ()) to the connectors (X8A, X5A and X6A) and the three points of the harness on the unit side. 6- Attaching panel X5A X6A X8A 5 6 () Draw out from the opening the harness attached in "5. Preparations for indoor unit" on page. Furthermore, pull out the lead wires disconnected from the corner decoration cover (with the display) in ". Preparations for panel" on page from the corner hole carefully so that the lead wires will not be caught by the mounting bracket. () Put the mounting brackets (in four points) on the corners of the panel to the hooks of the circumference of the indoor unit. (Hook the mounting bracket engraved with the PIPING SIDE first, followed by the mounting bracket on the opposite angle side.) At that time, pay attention that the harness and lead wires (on the panel side) will not be caught between the panel and indoor unit. Harness on the unit side Connector Be sure to connect them securely EL. COMPO. BOX Hook X5A, X6A 5 Harness (accessory ()) 6 Glass tube Make sure that the connectors are securely connected, or otherwise the swing flap, brush unit, or air filter will not work. 5- Attaching EL. COMPO. BOX lid Attach the EL. COMPO. BOX lid in the order opposite to the procedure in "5- Attaching harness (accessory ())" on page (). Make sure that the wires or glass tube will not be caught by the EL. COMPO. BOX lid. Leave your hands after confirming that the mounting brackets are engaged with the hooks. () Tighten the four hexagon head screws right under the mounting bracket for approximately 5 mm. (The panel will move upward.) (5) Turn the panel in the directions of the arrows so that the opening on the ceiling will be perfectly covered by the panel. (6) Furthermore, tighten the screw () until the distance from the lower part of the hook of the indoor unit to the lower part of the panel becomes 07 to mm. 6- () Check window Hook Temporary latching brackets Before temporarily hooking WARNING After temporarily hooking 6- () Arrange the electric wires neatly and attach the EL. COMPO. BOX lid securely. Hook The electric wires being caught or the rising of the EL. COMPO. BOX lid may result in an electric shock or fire. Mounting bracket After hooking Before hooking 6. Attaching panel to indoor unit Install the indoor unit by referring to the installation manual provided with the indoor unit. 6- () Drain socket Do not impose force on the swing flap, brush unit, or air filter when taking out the panel from the packing material (on the bottom side). PIPING SIDE engraved mark 6- Checks before attaching panel DRAIN SIDE engraved mark Check the directions of the indoor unit and the engraved marks on the panel as shown below. The piping block to the PIPING SIDE and the drain socket to the DRAIN SIDE. Stand the temporary latching bracket upright. Draw out the lead wires (on the panel side) from the opening. Installation manual 5 Make adjustments 6- (5) Piping Hook ( points) Check window Temporary latching brackets Before temporarily After temporarily hooking hooking Opening 6- () 6- (6) Tool (e.g., screwdriver) BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

Lower part of hook of the indoor unit 6- (6) () Draw the harness and lead wires (on the panel side). 07~mm Indoor unit (The ceiling is omitted from the illustration for ease of explanation) Lower side of panel Lead wire (on the panel side) Indoor unit Lower part of hook of the indoor unit 07~mm Seal Harness Lead wire (on the panel side) Ceiling Lower side of panel Mounting bracket Cross sections ( points) () Connect the connector of the lead wires and move the glass tube to cover the connector part. Lead wire (on the panel side) Tighten the screws securely, or otherwise a defect as shown below may result. Readjust the height of the indoor unit if there is a space between the ceiling and panel with the screws tightened securely. Air leakage Height adjustments to the unit will be possible through the holes on the corners of the panels without removing the panel, provided that the adjustments does not affect the levelness or the drain piping of the indoor unit. Refer to the installation manual of the indoor unit to conduct the work. Air leakage from the ceiling side. Generation of dirt Drew condensation or dripping Make sure that there is no space. Connector Be sure to connect them securely. Harness Move the glass tube. Glass tube () Tighten and secure both ends of the glass tube with the clamps on the glass tube together with provided clamps (accessories (5)). Cut the redundant portions of the clamps from their roots after the both ends are secured. Tighten the clamps Cut the roots Clamp (accessory (5)) (5) Return the connected lead wires to the space between the indoor unit and panel. (Accommodate the lead wires in the shaded part shown in the illustration.) 6- Checking panel () Remove sealing of panel. Harness Accommodate the lead wires carefully so that the lead wires will not come in contact with the air filter. Remove seal of panel Insert the seal until the seal comes in contact with the claw Claw Sealing (accessory (8)) BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05 Connected lead wires Connected lead wires EL. COMPO. BOX of the indoor unit Installation manual 6

(6) Remove the EL. COMP. BOX lid from the indoor unit. Refer to "5- Attaching harness (accessory ())" on page. () Hook the fall prevention cord for the dust box to the panel clasp as shown in the illustration. (7) Connect the swing lead wire connector to the PCB. X9A 5 PCB Connect the swing lead wire connector to the PCB Be sure to connect them securely. Swing lead wire (to X9A) (8) Attach the EL. COMP. BOX lid in the order opposite to the procedure in "5- Attaching harness (accessory ())" on page. (9) Guide the lead wires through the hook. 5 Clasp Hooked fall prevention cord Fall prevention cord Dust box () Attach the dust box in the order opposite to the procedure in "- Removal of dust box" on page. Make sure that the fall prevention cord is not caught by the exhaust opening on the dust box when attaching the dust box. Otherwise, the dust box may not function normally. () Turn the fixing knobs (in two points) of the dust box and secure the dust box. Fixing knob Hook Guide the wires through the hook 6- Attaching dust box Fixing knob (The front side of the panel is shown for ease of explanation.) b a 6-5 Mounting S-shaped pipe (accessory ()) 5 6 Mount the dust box side (engraved with A) before mounting the brush side (engraved with B). (Mount them so that the engraved characters will be in conformity.) 5 6 7 Engraved mark on piping side clasp Engraved mark on drain side Fall prevention cord Dust box Mount the dust box with the side where the mark is engraved faced downward. Dust box Brush unit 7 Make sure that the engraved characters are in conformity with each other. Brush unit Dust box Claw ( point) Claws ( points) Brush unit side S-shaped pipe (accessory ()) Dust box side Make sure that the engraved characters are in conformity with each other. Check that the claws are engaged securely. Otherwise, a dust collection failure may result. Installation manual 7 BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

7. Attaching suction grille and decoration corner covers () Connect the flexible hose (accessory ()) onto the panel side. (The flexible hose (accessory ()) has no directionality constraint.) Flexible hose junction on the panel side The suction grill can be rotated and attached in two directions, either one of which is selectable. If a number of units are installed, adjust the directions of the suction grilles if necessary. Make directional changes as well at the request of the customer. 7- Attaching suction grille * Select either the hook (A) or (B), and hook the claws of the suction grille. Flexible hose (accessory ()) The suction grille may be damaged if the wrong hooking side is selected. 7- Hook (A) () Set the suction grille to an angle of approximately 5 and put the hooks (in three points) onto the panel. Display on SUCTION GRILLE HOOKING SIDE GRILLE SUCTION G SIDE HOOKIN Flexible hose junction on the panel side Fit the claws into the hooks (in two points) securely. Hooks ( points) Check that the claws are engaged securely. Otherwise, a dust collection failure may result. () Press fit the flexible hose connected in () into the panel. (Pay attention so that the hose will not be caught by the suction grille closed.) Be sure not to break the flexible hose when press fitting the flexible hose. Flexible hose Suction grille 5 Suction grille mounting angle Press fit the flexible hose along the shape of the corner. () As shown in the illustration, hook the fall prevention cords for the suction grille to the corner clasps (on two corners). Change the directions of the fall prevention cords. To suction grille (5) Connect the opposite end of the flexible hose connected in () onto the suction grille side. * Rotate the flexible hose joint on the suction grille side according to the mounting direction of the suction grille as shown in the illustration. Flexible hose joint on the suction grille side Flexible hose joint on the suction grille side Flexible hose Fall prevention cord Clasp Clasp Bend the clasp inward. Connect the hose securely. Fall prevention cord BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05 Check that the claws are engaged securely. Otherwise, a dust collection failure may result. Installation manual 8

(6) Push up the suction grille slowly first, and while pressing the two knobs, finally fit the grille into the panel securely. Knobs ( points) () Connect the flexible hose (accessory ()) onto the panel side. (The flexible hose (accessory ()) has no directionality constraint.) Flexible hose junction on the panel side The suction grille can catch the fall prevention cords while the suction grill is closed. Check that the fall prevention cords do not protrude from the suction grille before closing the suction grille. Flexible hose (accessory ()) Fit the claws into the hooks (in two points) securely. Flexible hose junction on the panel side Must not protrude Hooks ( points) Fall prevention cord Check that the claws are engaged securely. Otherwise, a dust collection failure may result. 7- Hook (B) () Set the suction grille to an angle of approximately 5 and put the hooks (in three points) onto the panel. () Press fit the flexible hose connected in () into the panel. Pay attention so that the hose will not be caught by the suction grille closed. To suction grille Flexible hose Display on SUCTION GRILLE HOOKING SIDE SUCTION GRILLE HO OKING SI Press fit the flexible hose along the shape of the corner. DE 5 Suction grille mounting angle (5) Connect the opposite end of the flexible hose connected in () onto the suction grille side. * Rotate the flexible hose joint on the suction grille side according to the mounting direction of the suction grille as shown in the illustration. () As shown in the illustration, hook the fall prevention cords for the suction grille to the corner clasps (on two corners). Flexible hose joint on the suction grille side Flexible hose joint on the suction grille side Flexible hose Change the directions of the fall prevention cords. Connect the hose securely. Check that the claws are engaged securely. Otherwise, a dust collection failure may result. (6) Push up the suction grille slowly first, and while pressing the two knobs, finally fit the grille into the panel securely. Fall prevention cord Clasp Clasp Bend the clasp inward. Knobs ( points) Fall prevention cord Installation manual 9 BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

The suction grille can catch the fall prevention cords while the suction grill is closed. Check that the fall prevention cords do not protrude from the suction grille before closing the suction grille. Must not protrude () Attach the decoration corner covers (i.e., the three covers) to the panel. Fall prevention cord Press fit the five claws on the decoration corner cover into the holes on the panel. 7- Attaching decoration corner covers () Connect the decoration corner cover (with the display) securely to the PCB in the order opposite to the procedure in ". Preparations for panel" on page. Cover Connector Connect the connector securely. PCB Screw Lead wires Arrange the lead wires neatly so that the clamp will be on the inner side of the cover. Decoration corner cover (with display) Clamp () Attach the decoration corner cover (with the display) to the corner with the DRAIN SIDE engraved mark. Push the connected lead wires through the corner hole onto the backside of the ceiling. DRAIN SIDE engraved mark Lead wires Decoration corner cover (with display) Press fit the five claws on the decoration corner cover into the holes on the panel. () Hook each of the cords of the remaining decoration corner covers (i.e., three covers) onto the corresponding pin on the panel. Pin 8. Operation mode settings Any one of the following operation modes can be selected for the filter auto cleaning of the self-clean panel. Operation mode () Scheduled timer operation () 00:00-to-0:00 operation () Auto control operation Description Performs filter auto cleaning during the designated period selected from eight periods. Performs filter auto cleaning during the factory-set period of time (00:00 to 0:00). Performs filter auto cleaning according to the control reference. In consultation with the customer, set the desired operation mode by referring to the instructions on Filter Auto Clean in the operation manual for the Self Cleaning decoration panel. At the time of delivery, refer to the contents of descriptions () through () in the above table and explain the customer when filter auto cleaning will start. 9. Field settings Make settings in consultation with the customer according to the installation and usage conditions of the air conditioner. The following three settings are possible. 9- Dust quantity settings Make settings according to the quantity of dust in the room. Standard quantity of dust (General offices) Large quantity of dust (Stores dealing in clothing) 9- indicator (green) On/Off The panel indicator (green) can display the following operating conditions. Make indicator settings according to the request of the customer. Green Indicator Operating conditions Remarks Lit Flashing Air-conditioning operation Filter auto cleaning The indicator is turned off before shipping. The red lamp to inform the customer of the time of dust collection will not be turned off. BYCQ0D7GW + BYCQ0D7GFW Installation manual P0-B 05.05 0

Make field settings according to the installation manual of the remote controller. (Settings in bold cells are made before shipping.) Setting item Display Dust Collection sign Dust quantity settings indicator (green) on/off Mode No. 0 (0) () () FIRST CODE NO. SECOND CODE NO. 0 0 0 0 () Display No display (9) () Standard quantity of dust On while in air-conditioning operation and filter cleaning operation. Large quantity of dust Possible to turn on while in filter cleaning operation only. Off while in air-conditioning operation and filter cleaning operation. * Factory settings.... Cool Set to Cool 8 C Service Settings Indoor Unit Status Outdoor Unit Status Forced Fan ON Switch Main Sub Controller Filter Indicator OFF Test Filter Auto Clean Return Setting / Press and hold Cancel button for seconds or longer during backlight lit. Press Menu/Enter button. 0. Test operation Perform the test operation of the Self Cleaning decoration panel after the test operation of the indoor unit is finished. The test operation of the Self Cleaning decoration panel is not possible while the indoor unit is in operation. Perform the test operation of the product after referring to "a. Test items on completion of work". 0- Check that the EL. COMPO. BOX lids of the indoor unit, outdoor unit, and self-clean panel, respectively, are closed 0- Turn the indoor unit power on The panel will go into initialization operation after the power is turned on. 0- Conduct the test operation of the panel two minutes after the power is turned on Confirm the cleaning operation of the filter with the remote controller. Test operation method with remote controller. Stop the operation of the panel if the panel is in air-conditioning operation.. Continue pressing the Cancel button at least seconds while the backlight is lit. The service settings menu will appear.. Select Test Filter Auto Clean from the service settings menu, and press the Menu/Enter button.. " " will appear on the basic screen. The display will disappear when the test operation is finished. The required test operation time is approximately 0 minutes (in the case of setting the standard quantity of dust). Cool Collect dust Set to Cool 8 C Backlight for LCD Press any button and the backlight will be lit for approximately 0 seconds. Perform the operation of buttons while the backlight is lit (except the On/Off button). Test items on test operation Test items Is the filter rotating? Are the flaps fixed horizontally? Is " " displayed on the screen of the remote controller? Remedy Check the connector connections. Check result * The remote controller will display "AH" if the self-clean panel has an error. After the test operation of the product is finished, refer to "b. Test items before delivery" in the installation manual. Installation manual BYCQ0D7GW + BYCQ0D7GFW P0-B 05.05

Copyright 0 Daikin P0-B 05.05