Installation manual. Tumble dryers T4250, T4350. Selecta Control

Similar documents
Installation manual. Tumble dryers T4290, T4530, T4650. Selecta Control

Installation manual. Tumble dryers T4130. Compass Control

Installation manual Tumble dryer

Installation and converting instructions to another gas type T4530, T4650

Installation manual Tumble dryer

Installation manual. Tumble dryer T5675. Type N /AU Installation manual in original language

Programming manual. Selecta II Control

Installation manual Washer extractor

Programming manual Tumble dryers Compass Control

Installation manual Washer extractor

Service manual. Tumble dryers T4190. Compass Control

INSTRUCTIONS FOR USE - TUMBLE DRYER AWG 367

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE PROGRAMME CHART BOOKLET

INSTRUCTIONS FOR USE TUMBLE DRYER

INSTRUCTIONS FOR USE

How to get the most from your Integrated Tumble Dryer HJA 8800

INSTRUCTIONS FOR USE TUMBLE DRYERS

Installation manual W365H, W375H, W3105H, W3130H, W3180H, W3240H, W3300H Exacta & Clarus Control

CONTENTS QUICK REFERENCE GUIDE PROGRAMME CHART

SERVICE MANUAL. T4300S, TD30x30 WARNING

INSTRUCTIONS FOR USE TUMBLE DRYER

INSTRUCTIONS FOR USE TUMBLE DRYER

CONTENTS QUICK REFERENCE GUIDE INSTRUCTIONS FOR USE BOOKLET PROGRAMME CHART

User Manual. Tumble Dryer ZDC8202P

4KG Tumble Dryer / GVA4KG. Instruction Manual

Service manual Tumble dryers T4900, T41200 TD100, TD135

IMPORTANT: PLEASE READ THESE INSTRUCTIONS THOROUGHLY BEFORE USING THIS APPLIANCE. KEEP THEM IN A SAFE PLACE FOR FUTURE REFERENCE.

OFF. 20 min. 60 min. 30 min. 60 min OFF. 100 min Start. 200 min 150 min

INSTRUCTIONS FOR USE 8kg CONDENSER TUMBLE DRYER B96M8WR

CONTENTS READ INSTRUCTIONS FOR USE! INSTRUCTIONS FOR USE

TK 806 Z. Bedienungs- und Wartungshandbuch. Livret d instructions et d entretien. Manuale uso e manutenzione. User instructions and maintenance

Caution, risk of fire - this is a safety symbol. Failure to follow the warnings outlined in these user instructions can cause a fire hazard.

CI921 Integrated Tumble Dryer Installation, Use and Maintenance

WARNING FOR YOUR SAFETY FOR YOUR SAFETY. Outback Patio Heaters. Patio Heaters

Installation and Operating Manual Drying Cabinet

FLAME HEATER PYRAMID CLFH-10SS OPERATION INSTRUCTIONS

CI560 Freestanding Condenser Dryer Installation, Use and Maintenance

GETTING STARTED? EASY.

GETTING STARTED? EASY.

GETTING STARTED? EASY.

SERVICE MANUAL T3900/T31200 TD100/TD135

HOW TO USE YOUR 4500 RANGE L.P.G. COOKER OR HOB UNIT


MODEL T-30, T-50, & T-80 ON-PREMISE For GB & IE B-SERIES CONTROL, NATURAL GAS/LP HEATED

INSTRUCTION MANUAL GAS HOB. Model:GH600

SERVICE MANUAL T3300S TD Gas heated dryer WARNING

Drying Cabinet Installation and Operating Manual

CDC266 Reverse Action

U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

SAGV x 1/1 GN 7-12 x 20 COMBI STEAMER FOR GASTRONOMY

BWTD1 Fully integrated air-vented tumble dryer

Fast drying with low energy consumption

EDH3786GDW. EN Tumble Dryer User Manual

FOR YOUR SAFETY THIS MACHINE IS FOR DRYING ONLY FABRICS WASHED IN WATER.

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

User Manual HEAT PUMP DRYER

Gas Only Space Heater Mk II SH2201 / SH2211B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

Installation Plan Commercial Rotary Iron PM 1210 PM 1214 PM 1217

INSTRUCTION MANUAL GAS HOB

Portable Dryer 2.6 Cubic Feet

Grohtherm Wireless! Installation Instructions Pumped

EDH3887GDE. EN Tumble Dryer User Manual

ECOLINE. ECOLINE PATIO HEATER Infrared outdoor heater Assembly and instruction manual. Expand your life

MHG201 Gas Hob Manual for Installation, Use and Maintenance

TUMBLE DRYER MODEL: ED-F7160(WH) Owner s Manual Please read this manual carefully before operating your set. Retain it for future reference.

INSTALLATION INSTRUCTIONS TD75. Vented tumble dryer DOMESTIC. Carefully read the instructions for use before using the dryer.

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

User Manual Tumble Dryer LAVATHERM 65170AV

OPERATION MANUAL. SENSOR TUMBLE DRYER Model:SDRY60

User Manual Tumble Dryer LAVATHERM 61275AC

Installation and operation manual

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Operating Instructions. Tumble dryer ASKO T754HP. Dear Customer, Thank you for choosing this quality product from ASKO.

METOS M DV-60Q1K

s y ens Av Avensys FIN EST RUS SLO RUS UAE

Avensys Avensys FIN EST SLO RUS UAE

NAGV x 2/1 GN - 20 x 1/1 GN x 26 / x 20 DEVICE FOR GASTRONOMY

RECTANGULAR BUILT-IN GAS FIRE BURNER KIT ASSEMBLY INSTRUCTIONS AND SAFETY GUIDE

HG 675 CX 60 HG 675 CN 60 HG 675 CW 60

Contents. Dryer description, 4 The front The back Control panel

Grohtherm Wireless! Installation Instructions Pumped High Pressure

Drying Cabinet Installation and Operating Manual

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Avensys Avensys FIN EST SLO RUS UAE

Light oil / kerosene burner

INSTALLATION INSTRUCTIONS USER GUIDE

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

LAVATHERM 65270AC. EN User manual

Merloni Elettrodomestici. Technical Fitting Manual OVENS. Language Issue/Edition Page GB /

Tumble Dryer OWNER S MANUAL DRV7KGWH

5YK60XXX Series Fan. Owner s Guide and Installation Manual. CUL Model NO. : 5YK60XXX

INSTALLATION INSTRUCTIONS USER GUIDE. MIDEA 7kg Vented Dryer

WXHAP Washington Street Melrose, MA Phone Toll Free Visit us at

Please contact the machine's owner for proper service and repairs if the product appears damaged or defective.

51AKB / 51 AKC OWNER S MANUAL

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

Gas and Electric 4kW Space Heater SH4312B/ SI4312B INSTALLATION & USER INSTRUCTIONS. Thank you for purchasing this Whale product.

User Manual Tumble Dryer LAVATHERM 75380AH2

Ventilation Fan Model VFB24ACTH VFB24ADTH VFB24AXTH

INSTALLATION AND MANINTENANCE INSTRUCTIONS

Transcription:

Installation manual Tumble dryers T4250, T4350 Type N2... Selecta Control Installation manual in original language 487 05 43 61/EN 2010.06.09

Contents 3 Contents The front of the dryer... 4 Safety precautions... 5 Technical data... 7 Setup... 11 Unpacking... 11 Installation... 13 Mechanical installation... 13 Reversing door... 14 Installation on board a ship... 18 Evacuation system... 19 Air principle... 19 Fresh-air... 19 Exhaust duct... 20 Outlet dimensioning... 22 Adjusting the dryer... 24 Steam installation... 25 Gas installation... 29 Converting instructions to another gas type... 30 Electric installation... 35 Function check... 39 Dimenstion sketch Adapter for direct fresh-air intake... 41 The manufacturer reserves the right to make changes to design and com ponent specifications.

4 The front of the dryer The front of the dryer Affix the enclosed sign on the front of the dryer CAUTION! Remove clothes from dryer as soon as it stops. This keeps wrinkles from setting in and reduces the possibility of spontaneous combustion 487 01 29 00.01 487 01 29 00 W00083

Safety Precautions 5 Safety Precautions Do not dry unwashed items in the machine The machine is not to be used if industrial chemicals have been used for cleaning. Do not allow minors to use the machine. Do not hose down the machine with water. The machine's door lock must under no circumstances be bypassed. Items that have been soiled with substances such as cooking oil, acetone, alcohol, petrol, kerosene, spot removers, turpentine, waxes and wax removers should be washed in hot water with an extra amount of detergent before being dried in the machine. Items such as foam rubber (latex foam), shower caps, waterproof textiles, rubber backed articles and clothes or pillows fitted with foam rubber pads should not be dried in the machine. Fabric softeners or similar products should be used as specified by the fabric softener instructions. The machine may not be used to dry floor mops that contain polypropylene. The final part of a drying cycle occurs without heat (cool down cycle) to ensure that the items are left at a temperature that ensures that the items will not be damaged. WARNING. Never stop the machine before the end of the drying cycle unless all items are quickly removed and spread out so that the heat is dissipiated. Remove garments from the machine as soon as they are dried. This prevents them from becoming creased and reduces the risk of spontaneous ignition. If the machine develops a fault, this must be reported to the person in charge as soon as possible. This is important both for your safety and that of others. The machine must not be located where a door, sliding door, etc., can block the machine's door The machine is not intended to be used by people (including minors) with reduced physical or mental capacity or lack of experience and knowledge. Such people must be instructed in the use of the machine by a person who has responsibility for their safety. Minors must be supervised to ensure that they do not play with the machine. Adequate ventilation has to be provided to avoid the back flow of gases into the room for appliances burning other fuels, including open fires. Gas heated tumble dryer: The machine is not to be installed in rooms containing cleaning machines with perchloroethylene, TRICHLOROETHYLENE or CHLOROFLUOROCONTAINING HYDROCARBONS as cleaning agents. If you can smell gas, Do not switch on any equipment Do not use electrical switches Do not use telephones in the building Evacuate the room, building or area Contact the person responsible for the machine In order to prevent damage to the electronics (and other parts) that may occur as the result of condensation, the machine should be placed in room temperature for 24 hours before being used for the first time.

Technical data 7 (a) Electric and gas heating (b) Steam heating 1 Door opening = Ø 580 2 Operating panel 3 Electric connection 4 Gas connection 5 Steam: in 6 Steam: out 7 Pipe connection, evacuation A B (a) B (b) C D E F G H J K L M N O T4250 790 900 1100 1720 860 790 155 170 1505 100 1565 80 395 755 585 T4350 790 1120 1320 1720 860 790 155 170 1505 100 1565 80 395 755 585 P (a) P (b) Q T4250 1620 1820 740 T4350 1860 2040 740 A 2 B (b) B (a) J (a) 4 L (b) M 3 3 1 5 5 C 6 D E H O 6 K 7 7 N G F W00053 P (b) P (a) Q

8 Technical data Technical data T4250 Electric Gas Steam Drum volume Weight net Drum diameter depth revolutions per minute Capacity, max Heat effect litres kg mm mm rpm kg kw Air consumption Heat effect 9 kw m 3 /h Heat effect 13.5 kw m 3 /h Steam heating m 3 /h Piping evacuation Piping steam Steam in Steam out Max. counter-pressure Heat effect 9 kw Heat effect 13.5 kw Steam heating Gas piping Gas pressure Sound pressure level Ø Pa Pa Pa db (A) 250 250 250 161 161 176 760 760 760 550 550 550 45 45 45 12.5 12.5 12.5 9/13.5 13.5 * 360 - - 600 600 - - - 1000 200 200 200 - - ISO 7/1-R1 - - ISO 7/1-R1 650 - - 520 520 - - - 270 - ISO 7/1-R1/2 - - ** - < 70 < 70 < 70 * Depending on steam pressure ** See page regarding pressure

Technical data 9 Technical data T4350 Electric Gas Steam Drum volume Weight net Drum diameter depth revolutions per minute Capacity, max Heat effect litres kg mm mm rpm kg kw Air consumption Heat effect 13.5 kw m 3 /h Heat effect 18 kw m 3 /h Heat effect 21 kw m 3 /h Steam heating m 3 /h Piping evacuation Piping steam Steam in Steam out Max. counter-pressure Heat effect 13.5 kw Heat effect 18 kw Heat effect 21 kw Steam heating Gas piping Gas pressure Sound pressure level Ø Pa Pa Pa Pa db (A) 349 349 349 169 169 184 760 760 760 770 770 770 45 45 45 17.5 17.5 17.5 13.5/18 21 * 600 - - 1000 - - - 1000 - - - 1000 200 200 200 - - ISO 7/1-R1 - - ISO 7/1-R1 520 - - 270 - - - 270 - - - 270 - ISO 7/1-R1/2 - - ** - < 70 < 70 < 70 * Depending on steam pressure ** See page regarding pressure

10 Technical data Motor specifications T4250, T4350 Dryer with reversal Blower motor 3-phase Effect Revolutions per minute 50 Hz Revolutions per minute 60 Hz Drum motor 3-phase Effect Revolutions per minute 50 Hz Revolutions per minute 60 Hz kw rpm rpm kw rpm rpm 0.75 2700 3200 0.52 2700 3300 Dryer without reversal Drum / blower motor 1-phase Effect Revolutions per minute 50 Hz Revolutions per minute 60 Hz Drum / blower motor 3-phase Effect Revolutions per minute 50 Hz Revolutions per minute 60 Hz kw rpm rpm kw rpm rpm 1.0 2700 3200 0.75 2700 3200

Setup 11 Setup 1 Unpacking When unpacking the machine, handle it with care. The drum has no transport clamps. 500 mm A Fastened to the pallet The dryer is fastened to the pallet by two bolts. Open the filter drawer and then remove the front bolt. A Remove the back plate and then remove the back bolt. Tumbler type 4250 Max. 50 mm 1 From factory the dryer is equipped with 4 supporting feet (a). Min.150 mm Dryer type 4250 must be installed with all 6 supporting feet mounted (a+b). The last 2 feet (b) are temporarely mounted at the bottom on the back of the back cover. Unscrew the feet and carefully tilt the dryer forward and then demount the 2 feet (b). The last 2 feet are monted in order to stabilize the machine. Tumbler type 4350 B A - A A W00054 1 From factory the dryer is equipped with 4 supporting feet (a). Positioning 1 Place the tumble dryer in such a way that work can be done as easily as possible by the user and the service technician alike. The distance to the wall or other equipment behind the dryer should be min. 500 mm. Apart from the minimum distances shown on fig. 1 there are no further requirements to the distance around the dryer. However, there should be free access to the back of the dryer for the purpose of servicing it. The door hanging can be changed.

Installation 13 Installation 1 Mechanical installation Dryer type 4250 1 Adjust the dryer to ensure that it is horizontal and stands firmly on all six feet. The maximum height adjustment of the feet is 15 mm. A Dryer type 4350 Adjust the dryer to ensure that it is horizontal and stands firmly on all 4 feet. The maximum height adjustment of the feet is 15 mm. A A A A A A A W00055 The feet must be locked Bearing in mind the stability of the feet, it is important to lock the tumble dryer s feet with nuts A. After adjusting, reinstall the panels.

14 Installation Up to machine No. T4250 4250/101239 T4350 4350/100824 2 Reversing door 2 The loading door is reversible if it does not open to the desired side. Reversing 1. Disconnect the power supply to the dryer. 3 2. Open the operating panel. 3. Demount the filter door. 4. Unscrew the door and the front panel. 5. Unscrew the cover plate. 6. Demount the micro switch with fittings. 7. Squeeze out the black strip which is mounted in the back plate of the component unit 8. Run the cables including the black strip behind the back plate and across the drum. 9. The black strip must be mounted in the hole on the opposite side. 10. Unscrew the micro switch holder. Un - screw the micro switch from the holder, reverse it and mount it in the holder in the same order as before. 11. Move dummy plugs B in the side panel to the opposite side. 12. Mount holder with micro switch on the opposite side, use holes C. 13. Move speed nuts to the opposite side. 14. Mount the cover plate. 15. Check that all 4 terminal strips are mounted on the casing. 16. Reverse the front panel and the door and then mount them. Check that the felt joint is in good condition. 17. Close the operating panel and mount the filter door. 18. Unscrew the door pin and move it to position A. 3 Micro switch right C B W00056 C Micro switch left B W00057, W00058

Installation 15 Test the door 4 1. Connect the power supply. 2. Start the tumble dryer. 3. If the dryer does not start when the door is closed, adjust the door pin A. 4. Check that the micro switch on the door works correctly: The drum, ventilator and heat should stop when the front door is opened max. 40 mm. 4 A W00059

16 Installation From machine No. T4250 4250/101240 T4350 4350/100825 5 Reversing door 5 The loading door is reversible if it does not open to the desired side. Reversing 1. Disconnect the power supply to the dryer. 2. Open the operating panel. 3. Demount the filter door. 4. Unscrew the door and the front panel. 5. Unscrew the cover plate. 6. Demount the magnetic switch with fittings. 7. Squeeze out the black strip which is mounted in the back plate of the component unit 8. Run the cables including the black strip behind the back plate and across the drum. 9. The black strip must be mounted in the hole on the opposite side. 10. Unscrew the magnetic switch holder. 11. Move dummy plugs B in the side panel to the opposite side. 12. Mount holder with magnetic switch on the opposite side, use holes C. Note! When turning the bracket the wires are facing downwards. Lead them upwards towards the operating panel and fasten them with cable strips. 13. Move speed nuts to the opposite side. 14. Mount the cover plate. 15. Check that all 4 terminal strips are mounted on the casing. 16. Reverse the front panel and the door and then mount them. Check that the felt joint is in good condition. 17. Close the operating panel and mount the filter door. B B W00056A

Installation 17 Test run 4 Check for proper operation of the door switch, as follows: 1. Re-connect the power supply to the dryer 2. Attempt to start the dryer with the door open. It must not start. 3. Close the door and start the machine. Open the door. The dryer must stop. If the dryer starts with the door open, or fails to stop when the door is opened during operation, repair or replace the door switch, as necessary.

557 900 44 1120 44 777 18 Installation Installation on board a ship 6 The four accompanying fittings are fastened to the foundation by means of 4 x M10 set screws. 6 Drilling plan T4250 A A FRONT 14 753 782 T4350 M10 A A -A A FRONT 14 753 782 W00059

Installation 19 Evacuation system 7 Air principle 7 The ventilator creates low pressure in the dryer, drawing air into the drum via the heating unit. The heated air passes through the garments and the drum vents. Then the air flows out through a lint filter positioned immediately in front of the ventilator. After this, the air is evacuated through the ventilator and evacuation system. It is very important that the dryer gets enough fresh air, see next section. Fresh-air 8 For maximum efficiency and the shortest possible drying time, it is important to ensure that fresh air is able to enter the room from the outside in the same volume as that blown out of the room. 8 W00063 9 To avoid a draught in the room, it is advisable to place the air inlet behind the dryer. The area* of the air inlet opening must be 5 times the size of the vent pipe area. A The resistance in the grating/slats on the air inlet cover plate should not exceed 10 Pa (0.1 mbar). 5 x A *The area of the inlet opening is the area through which the air can flow without resistance from grating/slatted cover. Note that gratings/slatted covers often block half of the total fresh air vent area. Remember to take this into account. W00051 9 5 x A W00048

20 Installation Exhaust duct 10 The exhaust duct must be smooth on the inside (low air resistance). The exhaust duct must lead to the outdoors. The exhaust duct must lead clear of the building as condensation may cause frost damage to the building. The exhaust duct must be protected against rain and foreign objects. The exhaust duct must have gentle bends. The exhaust duct must not be a shared duct between dryers and appliances using gas or other fuels as their energy source. When several dryers share an exhaust duct 11 The exhaust duct diameter must increase after each dryer. The table below shows the exhaust duct diameter and the necessary fresh-air inlet area. Note! It is recommended that each dryer is connected to a separate exhaust duct. The evacuation pipe diameter must not be reduced. No. of dryers 1 2 3 4 5 6 7 8 9 10 Air outlet pipe diameter in mm 200 280 315 355 400 450 475 500 535 560 Required area of fresh-air inlet m 2 0.15 0.30 0.45 0.60 0.75 0.90 1.05 1.20 1.35 1.50 Each dryer requires a 400 x 400 mm fresh-air inlet opening.

Installation 21 Gentle bends 10 W00049 Several dryers share an exhaust duct 11 W00052

22 Installation Outlet dimensioning It is important that the dryer has the correct air volume compared to each dryer s effect. If the air volume is smaller or larger this will result in a longer drying period. Table with air volume and dryer effect Minimum air volume If the outlet air volume gets below the minimum air volume the microprocessor will report an error and error code E15 will be displayed. Type Effect Minimum Optimum kw air volume m 3 /h air volume m 3 /h 4250 6/9 260 360 4250 13.5 260 600 4350 13.5 260 600 4350 18 620 1000 4350 21 620 1000 4250/4350 ** - 1000 ** Steam heated Air volume control Example: A dryer type 4350 with a 13.5 kw effect must have an optimum air volume of 600 m 3 /h. 1. The specified air volume of 600 m 3 /h from column 2 is marked on the x-axis in the diagram on the following page. 2. Draw a vertical line from this point on the x-axis till it intersects the pressure drop curve. 3. From this point draw a horizontal line till it intersects the y-axis. 4. On the y-axis read the corresponding counter-pressure measured in Pa. By means of this pressure and the specified air volume the vent pipe can now be dimensioned.

Installation 23 Diagram with pressure drop curve type T4250 / T4350 12 Y = Pa 700 600 500 400 300 50Hz 200 100 0 0 200 400 600 800 1000 1200 X = Air consumption Y = Counter-pressure x = m3/h W00064 Service organisation/dealer If you have questions relating to the design of the exhaust system, please contact your local dealer or service organisation.

24 Installation Adjusting the dryer The dryer is adjusted by dismounting the back plate and measuring the static pressure behind the fan. 13 13 Drill a ø3.3mm hole A if there is not already one. The measuring is done on a no-heat program, without clothes in the dryer and with the back plate being dismounted. 120 By opening / closing the damper B the static pressure at A is either lowered or raised. Table with static pressure A 30 B The optimum air volume is achieved if the pressure is adjusted according to the table below. After the measuring is done screw the screw into the hole. W00065 Type Effect Static kw pressure Pa 4250 6/9 760* 4250 13.5 660 4350 13.5 660 4350 18 435 4350 21 435 4250/4350 ** 435 ** Steam heated * It can be difficult to obtain a static pressure of 760 Pa if the vent pipes are very short. In these cases the damper must be closed as much as possible. Note! The static pressures in this table are not to be mistaken for the counter-pressure from the pressure drop curve.

Installation 25 Steam installation 14 Before start The steam pipe must be cut off and must not be under pressure. a Steam Steam 3-10 bar absolute pressure (130-180 C). 5 b Steam forward 14 1. The branch pipe s branch must be located at the top of the main steam pipe to prevent condensation in the steam. 2. The branch pipe must have a descending gradient and must end at a height above the inlet connecting branch (5). For measurements M, N and O, please see dimension sketch page 7. 3. Mount a plug valve (a) and a dirt collector (b) in the branch pipe. 6 M b c O a N W00066 Condensation return 14 1. It is important that the branch pipe for condensed water on return to the main condensate pipe has a descending gradient and is lower than the outlet connecting branch (6). 2. Mount a dirt collector (b) in the return pipe. 3. Mount a mechanical water discharger behind the dirt collector (c). 4. Then mount a plug valve (a). 5. Mount pressure hoses between branch pipes and dryer (hoses are not supplied).

26 Installation Steam-heated dryer Mounting steam calorifier on dryer Dryer type 4250: The steam calorifier is on the pallet. Dryer type 4350: The steam calorifier is in the drum. 15 16 1. Unpack the calorifier. 2. Demount top back plate on the dryer. 3. Demount supporting rail on the dryer, see arrow (note which way the supporting rail turns as it has to be remounted the same way, see step 5). 4. Hang the calorifier on the bottom supporting rail on the dryer. 5. Hold the calorifier towards the dryer and remount the supporting rail as before making sure that it grasps the calorifier. 6. Screw the screws into the supporting rail. During the tightening process it is important to keep the dryer and the calorifier together. Note! After mounting the calorifier there must be no space between the dryer and the calorifier. 7. Mount back plate. 8. Attatch the pressure hoses to the dryer s inlet and outlet connecting branches. It is important to support the inlet and the outlet connecting brances in order to prevent deformation. The pressure hoses must not hang down. 15 16 W00067 W00068

Installation 27 Leak test 1. Leak test the system. 2. Clean the dirt collectors (b), see the previous page. Function check The function check is described in the back of this manual. Pipe insulation All pipes must be insulated in order to reduce risk of burning. Insulation also reduces loss of heat to the surroundings.

Installation 29 Gas installation To be carried out by qualified personnel Mount a shut-off valve upstream from the dryer. The gas connection to the dryer should be dimensioned to an output of 13.5 kw / 21 kw dependent upon the kw-rating of the dryer. The factory nozzle pressure setting corresponds to the fuel value given on the name plate. Check that the nozzle pressure and fuel value agree with the values given in the table. If not, contact the supplier. Bleed the pipe system before connecting the dryer. After connection, test all joints for leaks.

GB, IE Read the technical instructions before installing the appliance. Read the user instructions before lighting the appliance. This appliance may only be installed in a room if the room meets the appropriate ventilation requirements specified in the national installation regulations. 487229348.00. GB, IE Read the technical instructions before installing the appliance. Read the user instructions before lighting the appliance. This appliance may only be installed in a room if the room meets the appropriate ventilation requirements specified in the national installation regulations. 487229348.00. 30 Installation Converting instructions to another gas type Before installing the dryer affix the label "Read the user instructions" to the inside of the door, see pictures below. The label must have the correct country code - choose the correct label from the kit. GB, IE Read the technical instructions before installing the appliance. Read the user instructions before lighting the appliance. This appliance may only be installed in a room if the room meets the appropriate ventilation requirements specified in the national installation regulations. 487229348.00. W00069, W00070

Installation 31 Table of pressure and adjustment This gas appliance has been build to run on natural gas group I2H and I2E(LL), commonly identified by GNH. The data label shows the injector size and the injector pressure and the countries that use this gas quality: DK, NO, SE, FI, CH, CZ, EE, LT, SL, TR, BG, RO, GB, ES, GR, IE, IT, PT, AT, LV, HU, IS, SK, DE, PL, LU and non-european countries. Before connecting the appliance please make sure that the supplied gas type is correct. Following gas conversions are possible: 1. Appliances to be installed to run on GNH or GNL in FR, BE: I2E+ 2. Appliances to be installed in NL, parts of DE and Non-European countries: I2L. 3. Appliances to be installed to run on LPG in: DK, NO, SE, FI, EE, LT, SL, TR, DE, NL, CH, CZ, HU, GR, MT, CY, LV, SK, LU, BG and Non-European countries: I3B/P. 4. Appliances to be installed to run on LPG in: GB, ES, GR, IE, IT, PT, CH, CZ, BE, FR, CY, EE, LV, LT, LU, RO: I3+. 5. Appliances to be installed to run on LPG in: AT: I3B/P (50 mbar) inlet pressure. 6. Appliances to be installed to run on LPG in: PL: I3B/P (36 mbar) inlet pressure. 1 T4250 Gas group Injector size Ø mm (1) Air reducing plate Inlet pressure (mbar) Injector pressure (mbar) Label no. (fig. 7 ) I2H, I2E(LL) 3.1 NONE 20 10 DEFAULT I2E+ 2.6 NONE 20/25 20/25 487266713 I2L (LL) 3.1 NONE 20 OR 25 15 487266713 I3B/P, I3+ 1.8 NONE 30, 28/37 30, 28/37 487266711 I3B/P (37) 1.75 NONE 37 37 487266712 I3B/P (50) 1.8 NONE 50 30 487266712 2 T4350 Gas group Injector size Ø mm (1) Air reducing plate (fig. 6) Inlet pressure (mbar) Injector pressure (mbar) Label no. (fig. 7) I2H, I2E(LL) 3.8 A 20 10.5 DEFAULT I2E+ 3.3 A + C 20/25 20/25 487266718 I2L (LL) 3.8 A + D 20 OR 25 15.5 487266718 I3B/P, I3+ 2.3 B 30, 28/37 30, 28/37 487266716 I3B/P (37) 2.1 B 37 37 487266717 I3B/P (50) 2.3 B 50 30 487266717

32 Installation Conversion instructions - T4250 only: 1. Disconnect the power to the dryer. 2. Remove the back plate. 3. Remove nozzle. 4. Mount the enclosed nozzle (1), see Fig. 3. 5. Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch (2), see Fig. 3. 6. Connect the power and select a programme with heat. 7. Start the dryer. 8. See nozzle pressure in table on the previous page Fig. 1 - set the nozzle pressure on setting screw (4) under cover screw (3), see Fig. 3. 9. Check that the gas flame burns evenly and has a bluish colour. 10. Mount the cover screw (3), see Fig. 3. 11. Mount the back plate. NOTE: After the conversion has been carried out, the enclosed sign with the new gas type printed on it must be affixed to the dryer data plate, see instructions on the last page. 3 4+3 1 2 W00071

Installation 33 Conversion instructions - T4350 only: 1. Disconnect the power to the dryer. 2. Remove the back plate. 3. Remove the screw on the side of the locking plate x, see Fig. 5. 4. Pull out the locking plate x, this releases the gas pipe, see Fig. 5. 5. Remove the nozzle. 6. Turn the pipe a little and mount the supplied gas nozzle, see Fig. 2. 7. Push pipe with new nozzle back into its place. 8. Push locking plate all the way in and tighten the screw. 9. Replace/mount air reducing plate according to table, see Fig. 2. All air reducing plate types are shown in Fig. 6. 10. Loosen the measuring branch screw (2) 1/4 turn; connect a manometer to the measuring branch (2), see Fig. 4. 11. Connect the power and select a programme with heat. 12. Start the dryer. 13. See nozzle pressure in table Fig. 2 - set the nozzle pressure on setting screw (4) under cover screw (3), see Fig. 4. 14. Check that the gas flame burns evenly and has a bluish colour. 15. Mount the cover screw (3), see Fig. 4. 16. Mount the back plate. NOTE: After the conversion has been carried out, the enclosed sign with the new gas type printed on it must be affixed to the dryer data plate, see instructions on the last page. 4 4+3 5 1 x 2 W00071 W00072

34 Installation When the dryer is to be converted to another gas type, the data label on the rear of the dryer must be updated in order for the data to be correct. Place the data label enclosed in the conversion kit on top of the data label as shown below, see Fig. 7. For data label no. see Fig. 1 - T4250 or Fig. 2 - T4350. 6 C A B D W00073, 74, 75, 76 7

Installation 35 Electric installation - electric/gas/ steamheated 1 To be carried out by qualified personnel L1 L2 L3 N The tumble dryer must be connected to its own fuse group and pulti-pole main switch according to IEC 60947. Connecting the cable Demount the cover plate from the supply unit. 2 W00077 1 The cable is led through the cable gland to the terminal block and connected as illustrated. If there is a neutral conductor in the power supply line this must be connected to terminal N: Electrical heated with supply disconnector L1 L2 L3 N 2 Electrical heated 3 4 Gas and steam heated Gas and steam heated with supply disconnector 3 W00078 Cable dimension For calculation of the connection cable dimension, please refer to local guidelines. Fuse group and effect The sizes of the fuse group and the effect are shown on the following page. Function check The function check is described in the back of this manual. NB: Correct direction of rotation is important! 4 W00079 The tumble dryer must be equipped with supplementary protection in accordance with heavy current regulations. W00080

36 Installation Heat effect: Type 4250 = 6 k W / 9 kw / 13.5 kw Heat effect: Type 4350 = 13.5 kw / 18 kw Heating Voltage Heat effect Motor effect Max. effect Fuse alternative alternative kw kw kw A El heating 230V 1AC 50Hz 6 1.0 6.6 30 400-480V 3AC 60Hz 9 1.0 10.3 16 400-415V 3AC 50Hz 9 1.0 10.3 16 200-240V 3AC 50/60 Hz 9 1.0 10.3 35 440-480V 3AC 60Hz 13.5 1.0 14.5 20 400-415V 3AC 50Hz 13.5 1.0 14.5 25 400-415V 3AC 60Hz 13.5 1.0 14.5 25 200-240V 3AC 50/60 Hz 13.5 1.0 14.5 50 440-480V 3AC 60Hz 18 1.0 19.3 25 400-415V 3AC 50Hz 18 1.0 19.3 35 400-415V 3AC 60Hz 18 1.0 19.3 35 230-240V 3AC 50/60Hz 18 1.0 19.3 50 200V 3AC 50/60Hz 18 1.0 19.3 63 Gas heating Steam heating 200-240V 3AC 50/60Hz 1.0 1.1 10 400-415V 3AC 50Hz 1.0 1.1 10 400-480V 3AC 60Hz 1.0 1.1 10 230-240V 1AC 50Hz 1.0 1.1 10

Installation 37 5 To be carried out by qualified personnel External connection - 100 ma 5 A special connection terminal is located on the connection console. The terminal for external control is equipped with 110V/max.100mA and is intended solely for the operation of a contactor (external control of a fan). Max. connection 100mA. Gnd. must not be used for earthing of external board. External connection - 1.25 A 6 If the dryer, from factory, is equipped with an external control with a max. 230V/1.25A connection this connection (1.25A) can be used as connection of an external fan. Mount cable for external connection on contactor K7 in K7-2 and K7-4. Connect earth conductor to earth terminal in terminal for external connection. Max. connection 1.25A. 6 X1 X2 Gnd. Ext. connection Max. 100mA/110V AC X1 X2 Gnd. W00081, 84 Ext. connection Max. 100mA/110V AC N K7-2 230V K7-4 K7 K7-6 K7-14 External connection Max. 1.25A 487 19 69 48.01 W00082

Function check 39 Function check 1 To be carried out by qualified personnel Check whether the drum is empty and the door has been closed. Start the machine Check whether the door lock is working: The drum must stop if the front door is opened. Correct direction of rotation 1 Correct direction of rotation on fan wheel: clockwise. For dryers with a 3-phase motor the direction of rotation must be checked. If the direction of rotation is not correct, swop two phases on the connection terminal. W00050 Final test Let the dryer work for 5 minutes on a program that requires heat. Then check whether the heating is working by opening the front door and feel the heat. If the above tests-points are in order, the dryer is ready for use. Service organisation / dealer If deficiencies or errors are detected, please contact your local service organisation / dealer.

Dimension sketch - Adapter for direct fresh-air intake 41 Dimension sketch - Adapter for direct fresh-air intake 1 Adapter kit no. 988 800 442 - Gas- and electric heated dryer 2 Diameter Ø200 T4250 = 1130 T4350 = 1350 2 115 280 370 1 1

Electrolux Laundry Systems Sweden AB 341 80 Ljungby, Sweden www.electrolux.com/laundrysystems Share more of our thinking at www.electrolux.com