External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Similar documents
Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Chromatographic Air circulated Refrigerator, two-door TC 603

Laboratory Refrigerator/Deep Freezer TC 802

Chromatographic Air circulated Refrigerator, two-door TC 603

DOUBLE DOOR FREEZER.

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

ULTRA.GUARD ultra low temperature freezer

REFRIGERATOR M E D I C A L.

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Multi-Lab REFRIGERATORS Frigidere medicale

Constant climate chambers

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Constant climate chambers

Constant climate chambers

Fri.med. Srl Via Riva, 26/ Buttigliera d Asti (AT) Italy Tel Fax

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Internet. Climate rating definitions. Customer service.

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

Pharmaceutical Refrigerators* and Freezers. *according to DIN 58345

Constant climate chamber with humidity

Constant climate chamber with ICH-compliant illumination

PR / MP I Laboratory / Medicine

Laboratory Refrigerators and Freezers. Also with explosion-proof interior

XSD Dry Cabinet. Outstanding performance. The XSD series has an outstanding performance for drying moisture sensitive components and pcb s.

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Refrigerators and freezers Research and laboratory 2018

Laboratory Refrigerators and Freezers. Also with explosion-proof interior intrinsically safe, independently tested as well as certified.

Laboratory Refrigerators and Freezers

MEDICAL REFRIGERATORS

BIOMEDICAL REFRIGERATORS

MSD Cabinets. Modular Dry Cabinet. Outstanding performance

ICH260C. Climate Chamber. Product specification

ICH110. Climate Chamber. Product specification

Long Term Storage Cabinet

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

ICH750L. Climate Chamber. Product specification

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

Laboratory refrigerators

Laboratory refrigerators and freezers

Cold chain monitoring technologies. Facility monitoring

Stability Chambers & Rooms

Thermo Scientific Revco UxF -80C Series Upright ULT Freezers

ICP450. Compressor-cooled incubator. Product specification

CLIMATIC TEST CHAMBER CTC / TEMPERATURE TEST CHAMBER TTC 100 % AtmoSAFE: In Memmert environmental

NEW GENERATION. Efficient use of valuable space INCUBATORS

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

Platelet bags constant shaking for long periods of time.

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

STABILITY ICH. ICH Stability Tests

Walk in Freezer. Comfortable work environment

ATSTORM v2. The sensor with FCES technology is connected to the interface with a communication cable.

Model KBF 240 Constant climate chambers with large temperature / humidity range

Monitoring Solutions

Blood Bank Refrigerators

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Upright Freezers. Laboratory Plasma. TrueBlue. Reliability & Support. i.series Horizon Series

Medical Refrigerators

Laboratory thermostatic chambers

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Measuring Recording Online Monitoring Regulation Alarming

Laboratory Refrigerators

FITOCLIMA 600 & 1200 STABILITY

Refrigerators and freezers Pharmacy and laboratory 2016

SCAN200E USER S MANUAL

Model KBWF 240 Growth chambers with light and humidity

Air & Water Heat Pump R832

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Laboratory Refrigerators and Freezers

Refrigerated Incubators / Environmental Testing Chambers

Heated and Refrigerated Incubators

Plant growth chambers

Model CB 220 CO 2 incubators with hot air sterilization and heat sterilizable CO 2 sensor

Environmental simulation chamber for complex alternating climate profiles

Laboratory Pharmacy Blood Bank. Upright Refrigerators and Freezers

Protection, safety, reliability. And more.

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Blood bank refrigerators and freezers. BBR & Mini - Platinum & Iridium - Plasmafrost Series

Constant climate chambers

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

LR range (solid door) LR 750 G / GG

smallest detail Laboratory refrigerators with analogue controls and spark-free interior

Mobeye CM2410 GSM fire alarm communicator

FITOCLIMA 600 & 1200 STABILITY

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Dew point set DS 400

EL-USB-TC Thermocouple Data Logger with USB Interface

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Transcription:

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm Capacity: 600 l Temperaturerange: 2 C to 20 C Housing galvanized sheet steel with high quality white coating. With 4 feet, height adjustable. Optional: of stainless steel (Backplane, as well as top and bottom side of the cabinet of galvanised sheet steel) Set of 4 castors, 2 lockable Interior space Inner case of galvanized sheet steel with high quality white coating. Cleaning friendly by rounded corners, slippery surface in the interior, meets highest hygiene requirements Optional: of stainless steel Insulation high density foamed-in-place polyurethane, with a thickness of 75 mm. CFC-free Circulaton air cooling for rapid and uniform temperature control, reducing temperature gradients to a minimum. When the door is "open" the circulating fan is switched off automatically by a micro switch in order to prevent warmer ambient air being drawn in. Air circulated fan inside the cabinet. Atex-marking: II 3G Ex na IIA T4 Gc (-30 TA +35 )X, ITS14ATEX47658X Optional: Air circulation fan outside the inner case. Door Solid door, supplied as standard with right hand hinge, also available with left hand hinge at no extra cost.. Grease resistant magnetic seal. Optional: with glass door with door lock Interior fittings 4 pcs. Grating-type shelves (dim.: 530x550 mm), white coated (max.13 shelves possible) Optional: Stainless Steel shelves or Stainless Steel drawer compartments, with 3 lengthwise dividers (max. 13 drawers possible) with telescopic-type guides on rollers with stops, Drawer dimensions: 500x475x77 mm (BxDxH) Usable width between the lengthwise dividers: 108,5 mm (lengthwise dividers easily removable) technische Änderungen vorbehalten Seite 1 von 7

Control system located above the door Touchscreen temperature controller, TC 2015 Working range from 2 C to 20 C (provided that the ambient temperature is around 4 C above the set point) Temperature accuracy +/- 1,8 C after stabilising (with 50% filling) Language in German / English adjustable Touchscreen Display, size 12,5 cm (5 ) PT1000 temperature sensor for better temperature control accuracy Digital temperature setting and display with an accuracy of 0.1 C Power supply of 100-240V, 50-60Hz Password protected to prevent manipulations Data import/export via USB or Ethernet Alarm - Noticeable optical alarm signaling by red / blue flashing screen - Audible alarm Mute the audible alarms, with continuous warning indication on the display and automatic return after 3 minutes when the alarm situation still exists - Alarm acknowledgment with password protection Acoustic and optical alarm indication when - High and low temperature (variably adjustable) - Door open - alarm, (adjustable) - Power failure - Temperature sensor failure - Defrost-time transgression (variable adjustable) - Optional: cooling machine monitoring with overheat protection Alarm memory (not deleted) for the last 100 alarm conditions, with the possibility of review on the display and archiving the data via USB or Ethernet. Memory can not be deleted. Event memory In the event log all the operations of the controller are saved, such as: - Doorways - Parameter changes - Cooling equipment function, etc - Storage for approximately 4 weeks, with the possibility of review on the display and archiving the data via USB or Ethernet. Graphical display of the temperature profile in the display Illustration of the actual value and if requested of the product sensor on the display and archiving via USB or Ethernet. View period freely selectable. technische Änderungen vorbehalten Seite 2 von 7

Network Connection 2 Ethernet ports 10/100 Mbps available. This interface can be accessed directly on the log data of the controller to import in the software. NO/NC contact Alarm signal time delayed (adjustable) Language: English / German, other languages on request Maintenance message: Notification that maintenance should be carried out. Test facilities for Alarm limits and battery charge status In the housing of the temperature regulator there are all relevant components for using the cabinet. Plug-in connectors of the electrical supply pipes enables a service friendly exchange. Optional - Battery Module In case of power failure self-contained supply of the temperature controller with a powerful battery. All control functions are saved for about 72 hours. - 0..20 ma Output - WLAN-Module - Interface, RS 485 (galvanically isolated) - Software This software enables you to check at a glance several cooling units. It was designed to be user friendly and enables you to process your data in an intuitive manner. - Alarm system - Independent product sensor for reference measurement - Product protection against low temperatures. By dropping below the setpoint value, the cooling machine will switched off - Battery module as a standard feature Security barrier (EN 50014 and EN 50020) for temperature sensor (according to ATEX directive) Refrigerating unit fully hermetically sealed, forced ventilation, fitted on vibration - absorbing mounts (ambient temperature max. 32 C), low noise (50 dba/1m), energy saving compressor with high quality vaporisation system. Refrigerant: R 404a Defrost Automatic, with time monitoring. Dew water collector tank for manual emptying, located below refrigerator floor. Electrical Data Power supply 230 V/50 Hz /single phase Optional: 60 Hz Power input 110 W Energy consumption 2,6 KW (24 hours.) Fuse 16 A Power cable: 1,5 m with schuko plug Packing details (palletized) Dimensions: approx. 85x98x224 cm Net weight: 155 kg Gross weight: 175 kg Country of Origin: European Community Customs clearance code: 8418 5090 technische Änderungen vorbehalten Seite 3 von 7

Technical indication: This refrigerator is classified as internally spark resistant and have no electrical components in the interior, reducing the risk of fire or explosion. (The class of explosion protection provided by this equipment meets Federal German safety regulations for laboratory equipment DGUV Information 213-850. The appropriate regulations must be observed in other countries). Special Equipment and Accessories: GSM Modul Connecting to the potential-free output. In case of an alarm either a message or a call will be sent automatically. Archiving of 1000 phone numbers is possible. The GSM module is equipped with a rechargeable battery. Automatic alert via SMS when the credit has been used on the SIM card. 6 units can be connected per module. The SIM card is not included Round Chart recorder to record temperature, permanently installed in control panel. Comes as standard with battery back-up power supply for continuous operation (mains independent).the replaceable recording discs are suitable for 24 hours or 7 day periods. The actual temperature is plotted with a black felt tip pen on the chart. Internal temperature measurement. Measurement range: -10 C to 40 C The unit comes with 100 round charts (day or week) Door lock including 2 keys Optional: electronic door lock, via temperature controller TC 2015 Cable port with cover (approx. 40 mm ). Cable port with PG-gland for example to create access for operator measurement lines, etc. Optional: with separate sensor kind and version as desired by the customer technische Änderungen vorbehalten Seite 4 von 7

Wireless data logger, complete consisting of: Wireless data logger, SPY RF U1-ex 1-channel for Pt100, 4-20mA / 0-1V / contact on-off, with display Measurement accuracy at 23 C: +/- 0,3 C Resolution 0,1 C Battery: Lithium Battery Recording interval: 1 sec. to 90 minutes Internal memory: 10.000 measurements Usable range: 1km LOS Communication: via radio 868 Mhz Power: 25 mw incl.1 pcs. Sensor Cable Resistance sensor with ATEX Exi certification Pt100 class A, 3-wire circuit with the cable connected TFDT L 4 4x0, 22 mm ² Protective tube D 4mm x 30 mm length, 1.4571 Measurement area: -200 C +200 C Length: 3 meter Optional: 8 meter Delivery contents: wall mounting holder and plug protection Software - Basic Version for single user - Maintenance of multiple Wireless data logger - collect the recorded data of the Wireless data logger - Back up data (tamper-proof) - Prepare the data in terms of graphics or charts - Excel exportable - Maintenace of alarms via potential free contact at the Modem or Alarmsystem (SMS, phone call, blinking light, buzzer) SPY RF USB-Modem for data transfer to the PC via USB-connector - Communication with infinete numbers of Wireless data logger - Remote alarm via integrated potential contact - including wall mounting holder technische Änderungen vorbehalten Seite 5 von 7

Optional: Cable Resistance Sensor with ATEX Exi certification Pt100 class A, 3-wire circuit with the cable connected TFDT L 4 4x0, 22 mm ² Protective tube D 4mm x 30 mm length, 1.4571 Measurement area: -200 C +200 C Length: 8 Meter SPY RF Relay (Repeater) - Allows the data transfer of the data logger about bigger distances - Can transfer dates of one or several SPY RF data logger - Electricity supply about power supply unit and battery in case of power failure - with 2 output ranges: 25mW to communicate with the data logger and 500mW to communicate with the modem. - Delivered with wall mounting fixture - Ambient temperature: from -10 C to +70 C SPY RF Alarm - realtime alerting - i.e. by limit exceeded or power failure - Local warning - Integrated acoustical and optical Alarm - Power supply via external power adapter and spare battery in case of power failure - Button for local alarm quitt - Relais output for remote alarm (GSM-Modem, telephone dialer) - including wall mounting holder SPY RF Telephone dialer - In the speech modus it called up to 6 different subscriber and informed them about the kind of failure - This ergonomically linguistic aid provides high operational ease. - requires an analogue phone line - Individual adjustment of identification, alarms and alarm quitt - requires an external power supply (included) GSM-Modem I for switch contact For use with: Software - Basic Version and SPY RF USB-Modem, or SPY RF Alarm - Enables to send SMS messages - Modem registered also power failure and send SMS immediately. technische Änderungen vorbehalten Seite 6 von 7

Qualifications DQ (Design Qualification) Definition: Documented proof that the quality-related, GMP-related requirements has been adequately addressed in the design of equipment, including buildings, premises and auxiliary equipment The user-requirement profiles (specifications) are documented and confirmed by us. On request, a specification can be created by us. IQ (Installation Qualification) Definition: Documented proof that critical equipment and systems have been delivered and installed in accordance with the set requirements and government regulations. The IQ documentation is worked out by us especially for the delivered machine and is made available to you. The IQ documentation has to be carried out by the customer itself. OQ (Operational Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole operating range are working as intended in accordance with predetermined limits. The OQ documentation is worked out by us especially for the delivered machine and is made available to you. The OQ documentation has to be carried out by the customer itself. CQ (Calibration Qualification) Definition: Documented proof that critical measuring equipment in the intended range in accordance with predetermined tolerances operate reliably under current operating conditions Checking the temperature in the cabinet 1 Temperature on 3 different measuring points (measured with calibrated PT 100 sensor) evenly located on the shelves. Inspection time 6 hours, open door after that of 30 seconds. The inside temperature of the cabinet must have been stabilized itself within 1 hour on the set point temperature. The measurements are carried out in the empty state. The temperature measures are carried out in our company, represented graphically and provided to you. The values may not dropping below or above the tolerances given by us. (Additional measuring points on request) PQ (Performance-Qualification) Definition: Documented proof that critical equipment and systems in accordance with the set requirements in the whole workspace under current working conditions (with product) provide the requested services The calibration described above is carried out under real conditions on site. The values may not dropping below or above the tolerances given by us. technische Änderungen vorbehalten Seite 7 von 7