ACL 4 ANATOMY. COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LED lifespan. 1.87

Similar documents
light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

FULL BLEED APPLICATION SHOT RENDERING

l i g h t A B S O R B H

Grüv Flare Regressed. Recessed Linear LED

Grüv Flare Regressed. Recessed Linear LED

LUX PENDANT DIRECT/INDIRECT

M100 My White LED Direct Tunable White

Evolution EXWW RECESSED LINEAR WALL WASH LUMINAIRE

RECESSED Spec Guide. up to 111 lm/w performance

M60 LED Recessed Wet Location

SURFACE Spec Guide. up to 105 lm/w performance

Fino Healthcare. Asymmetric Wall Mount Indirect LED

BAS SDL8' LED Strip Diffused Lens

*REPRESENTS 3500K/80CRI 2 FT 4 FT 6 FT 8 FT 2 FT 4 FT 6 FT 8 FT *REPRESENTS 3500K/80CRI LINEAR

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

2200TD-3000TD Dim to Warm* 2700T-6500T Tunable White* *Must be ordered with D05 or DS5 Driver options; excludes 2' and 3' lengths

M100 LED Direct/Indirect

MEDLEY A. RoHS COMPLIANT INTERIOR - INTEGRAL POWER SUPPLY WHITE LIGHT & STATIC COLORS SHAPING THE EXPERIENCE OF LIGHT

Recessed LED Wall/Slot SAE 202

SDL4 LED Strip Diffused Lens

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

LHBXD LED Linear High Bay

Dimensions (111mm) (111mm) 3 (76mm)

RECESSED T-Bar & Drywall

RECESSED - WITH StepLens OPTION

Fino. Asymmetric Wall Mount Indirect LED

VESICA LINEAR SUSPENDED VES L

Fino Healthcare. Asymmetric Wall Mount Indirect LED

SOL CROSS SECTION. PENDANT Spec Guide. Page 2 of Rev. JUNE18-1

Etch 2' x 2' Recessed LED

M36 My White LED Direct

M-LED for 4 Technical Ceilings Recessed Linear LED for 4 Technical Ceiling Systems

Max 4 Flush Lens RECESSED

Catalog # Project. Comments. Prepared by. Warranty Five year warranty

Linea 1.5. Linear Direct Wall Wash LED

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

Claude Indirect Wall WALL

Alliance 4 - ALI4 LED 4 Linear High Bay

LIVMODERN LIVMODERN RPT. Elegant linear LED fixture PART NUMBER BUILDER 10VDIM 0-10VDIMMABLE 3000K 4000K 24IN 36IN 48IN 1800LM* 3000LM** 3500LM***

ZipTwo LED 707. Micro-profile interior direct lighting for open office, wall wash and wall graze applications. Spec Guide

PRELIMINARY PRODUCT CODE TYPE LOCATION DRIVER OPTICS LENGTH WATTAGE COLOR TEMP CABLE 3 + MOUNTING. Wall Grazer. Flood 32ºx85º K E End

HBEAM 1.25 PRE-DESIGNED HB1.25 PRE-DESIGNED STRAIGHT SECTIONS (2FT - 8FT)

VIENTO MEDIUM AREA & SITE LED LUMINAIRE OPTICS

Performance Chart Electrical Data

Truss Surface SURFACE

Performance Chart Electrical Data

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

DIMMING 0-10V Continuous

DHL-LP-LED Low Profile LED Linear High/Low Bay

FPLHB - Fidelux Premier Linear Highbay

WARRANTY LED ECO PANEL.

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

BeveLED Cylinder LBRP6 Surface

NOVENTA NV3.5 Suspended, Surface, Wall, Recessed LED

Hornet HP. Round Glass Downlight

Performance Chart Electrical Data

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

Evolve LED Garage Light

LED ECO PANEL.

Performance Chart Electrical Data

Qty: L lm/12.6W K. DC3 Lutron 3-Wire. DMD eldoled DALI. DC2 5 Lutron 2-Wire

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

BAS SFP22 Edge-lit LED Panel

Catalog Number. Notes

PRODUCT DATA SHEET LIGHTING PRODUCTS

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

New Linear Series DISCONTINUED

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

LED RETROFIT SOLUTIONS

D O M E S T I C LED. Lighting C O M M E R C I A L

Classix 6" 6" Round Lens Wall Wash

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

Ordering Information: 4-ASI5-LED-WDM-35K-18K-4000L-MVOLT ASI5-LED

LED FLAT PANEL EDGE LIT MLFP SERIES G2

Hornet HP. Square Glass Downlight

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

CPPG ENERGY EFFICIENT CANOPY LIGHTS FOR PARKING AREAS

Vaya Linear LP, White & Mono

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

OLS-DI-LED LED ARCHITECTURAL LINEAR SYSTEM. Warm Dim with Smart Dim Technology LED ARCHITECTURAL SUSPENDED LINEAR DIRECT/INDIRECT SYSTEM

Linea 2.5. Linear Indirect LED

ArtLED Gallery and Museum Spotlights

The only lighting product that is designed, approved, and patented to replace the cross members in a suspended grid ceiling system.

PRODUCT CODE DRIVER FACEPLATE FINISH WATTAGE COLOR TEMP VOLTAGE

LED RETROFIT CONVERSION KITS

SPECIFICATIONS HYLYTR. with DOUBLE SLOT OPTICS

Product Specifications MaxLumen MRI LED Diffused Lighting

LED HIGH BAY LINEAR ECO SERIES

FLEX. Innovative lighting engineered for seamless integration into the DESIGNFlex ceiling system by

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

Excellence in LED Lighting. e-solis Edge Lit LED Panels.

Murro HP. 3.5" Round Surface Canopy Wall Wash

Altman Lighting Spectra Cyc UV 50 Specification

Performance Chart Electrical Data

LED Lighting Product Guide. Spring A portfolio of industry-leading solutions that are changing the way we look at light.

lumenalpha downlight Specification Sheet

Ivalo Lumaris LED Linear Lighting

Transcription:

ANATOMY COVER UP Partially diffuse dust cover enhances indirect lighting performance and preserves LE lifespan. 1.87 MULTIFACETE ISTRIBUTION Versatile design application is achieved through selection of available symmetric wide, symmetric narrow, and asymmetric light distribution. POWERFUL PERFORMANCE High performance Nichia 80+ CRI LEs provide an optimal light source for tailored lighting design. SURFACE STYLE irect to surface and mullion mounting options enable sophisticated architecturally integrated illumination. SLEEK & STRONG A perfectly square aluminum extrusion made of 60% recycled material provides durable functionality in an elegant compact form. CORE CAPACITY Integral 0-10V dimming driver down to 10% or 1% standard. Additional options include Lutron, MX, and ALI control protocols. Integral IOTA slim 12W emergency battery pack provides an easy solution for egress compliance. ELEMENTS Elements is a simplified product line comprised of 4, 8, and 12 nominal length fixtures that can be joined to create continuous rows. INTEGRATIONS Integrations is a comprehensive product line comprised of exact length fixtures, continuous rows, and patterns comprised of 90 illuminated corners. 4 8 12 R For rows over 12 (R) fixtures will be shipped in sections. Joining hardware for field installation is provided. INTERGRATIONS+ Integrations+ is a completely custom ordering process allowing unique modifications and non-90 transitions through collaboration with esign Assist.

PHOTOMETRY LIGHT OUTPUT ISTRIBUTION Indirect Asymmetric Indirect Symmetric Narrow PHOTOMETRIC ATA OUTPUT LH: High output -10 W/ft LS: Standard output - 5 W/ft C: Custom tuned output - Specify Wattage LIGHT LOSS FACTORS LH: Baseline LS: 50% 4000K: Baseline 3500K: 97% 3000K: 93% 80+CRI: Baseline 90+CRI: 80% INIRECT ASYMMETRIC 4000K - UST COVER Lumens: 596 lm/ft Input watts: 9.6 W/ft Efficacy: 62 lm/w ILH ILS INIRECT SYMMETRIC NARROW 4000K - UST COVER Lumens: 794 lm/ft Input watts: 9.5 W/ft Efficacy: 84 lm/w ILH ILS SAMPLE INSTALLATION - CORRIOR ASYMMETRIC - LH UP / 4000K Corridor height: 10 ft Reflectance: 80% / 50% / 20% Mounting height: 7 ft A.F.F. (on wall) Fixture length: 12 ft Calculation grid: 2 ft x 2 ft Calculation plane (horizontal): On floor Average Illuminance: 11 fc Uniformity: 1.4:1 (avg/min) 10 11 12 12 12 11 10 11 13 14 14 14 13 11 11 12 13 14 13 12 11 10 11 12 12 12 11 10 8 9 10 10 10 10 8 TOP VIEW 13 fc 12 fc 11 fc

MOUNTING MOUNTING OPTIONS 1.00 1.00 (R) irect wall mount (F) Bottom mount (M) Mullion blocks (J) Span (JS) Partial Span STANAR PATTERNS CORNER ETAIL 2 2 2 3 3 1 1 1 4 Welded corner (PL) (PU) (PR) Joining pins

ELEMENTS Ordering Code ACL4 Project Info ate Type Quantity Series: ACL4 Length: Nominal 4 Nominal 8 Nominal 12 Nominal length 16 and over Specify length in 4 increments Output: 4 8 12 R Emergency: Emergency - battery (1) ILB-SL-CP12 (1200lm for 90min) Options: New York City code E1 N LE standard output (5 W/ft) LE high output (10 W/ft) LS LH LE CCT: 3000K 3500K 4000K 30 35 40 Voltage: Universal 120V - 277V 347V U 3 Indirect istribution: Symmetric narrow Asymmetric G N Indirect Optics: Rigid diffuse dust cover Mounting: irect wall mount Bottom/Surface mount Mullion blocks M1=1 M5=1/2 R F M Finish: a lightanium Satin white Satin black T W B imming: Standard 0-10 dimming imming to 1%, see technical section Lutron Eco H series (LE1) 1 amp Location Rated Wet Location Rated

INTEGRATIONS Ordering Code ACL4 Project Info ate Type Quantity Series: ACL4 Finish: Length or Pattern Type: Exact Length Specify in inches to the nearest 1/8th e.g. M180.00 M a lightanium Satin white Satin black Other Specify RAL# T W B O Pattern options: Specify in inches to the nearest 1/8th See Pattern Guide for details. L Shape left e.g. PL103.125 x 134.00 U Shape e.g. PU103.125 x 134.00 x 103.125 Rectangle / Square e.g. PR103.125 x 134.00 Output: LE standard output (5 W/ft) LE high output (10 W/ft) LE custom output PL PU PR LS LH C imming: Standard 0-10 dimming imming to 1%, see technical section Lutron Eco H series (LE1) Other dimming specify model/series Emergency: Emergency - circuited Emergency - battery ILB-SL-CP12 (1200lm for 90min) Specify desired quantity of battery s Not available on fixtures < 4 length 1 3 EC E LE CCT: 3000K 3500K 4000K Voltage: 30 35 40 Sensors: Occupancy Sensor Wattstopper FS-205 (Ø1 ) Photocell/aylight Sensor Wattstopper F-301 wired for daylight harvesting. Requires 0-10V dimming Occupancy & aylight Sensor O P OP Universal 120V - 277V 347V Indirect istribution: Symmetric narrow Asymmetric Indirect Optics: Rigid diffuse dust cover U 3 G N Options: Multi-circuit Submit multi-circuiting requirements Right endcap feed Left endcap feed New York City code Wet location Contact esign Assist 90+ CRI M R L N Q CRI Mounting: irect wall mount Bottom/Surface mount Mullion blocks M1=1 M5=1/2 Full span Partial span R F M J JS amp Location Rated Wet Location Rated

TECHNICAL ATA LINEAR IMENSIONS Elements - 4, 8, and 12 nominal length individual fixtures that can be joined to create continuous row lengths. Integrations - Exact lengths to the nearest 1/8th of an inch available as individual fixtures or joined to create continuous row lengths, minimum fixture length is 12 inches. Patterns comprised of 90 degree precisely welded fully illuminated corners provide a multitude of geometric options and architectural transitions. Integrations+ - Contact esign Assist for modifications to product not detailed within Elements or Integrations specification sheets. OPTICS A rigid partially diffuse extruded dust cover lens optimized for indirect LE performance delivers 92% transmittance. LE LIGHT SOURCE Custom manufactured linear board array uses high performance Nichia LE in combination with a performance driven heat sink technology. Tested in accordance with LM79 and LM-80; L70>60,0000hr; operated at reduced output for high efficacy and lumen maintenance. 3000K, 3500K, and 4000K with 80+ CRI standard; other color temperatures and 90+ CRI available upon request, contact factory. LE color variation maintained at a 3-step MacAdam ellipse (SCM 3x). LEs are available in Low, Standard, and High outputs. Refer to photometry for delivered lumens. Custom output available in the range of 25% - 125% of high output, contact factory. LE RIVER Factory tuned constant current electronic 0-10V control dimming driver is standard. Specification grade dimming down to 10% or 1%. Specify if 1% dimming is required. Constant lumen maintenance ensures LE s will maintain required lumen output to end of life to increase energy savings and enhance reliability. river life of 50,000 hrs with ambient operating temperature range of -30 C to 50 C, maximum case temperature of 75 C. Electrical specifications at maximum driver load: PF >0.9, TH <20%, >85% Efficiency. Other available drivers include Lutron Eco-system H-series (LE1): Hi-lume 1% LE dimming driver with Soft On, Fade to Black; and MX and ALI protocol drivers. Other Lutron and specialty drivers available, contact factory. EMERGENCY Factory installed integrated fixture LE emergency battery pack for both normal and emergency operation. Unit contains long-life Ni-Cad recyclable battery, 24 hour charger, and converter circuit. Test switch and charge indicator provided. Test button to be remote located by others in accordance with local code. Emergency mode provides constant power to a nominal 12W LE load for a period of 90 minutes, delivering 1200 lumens of unwavering illumination throughout the full 90 minute emergency duration. Unless otherwise specified, the emergency battery pack will illuminate one 2 foot end of the fixture in the direct portion of the fixture. Emergency circuiting provided as a separate circuit from normal power circuit according to NEC requirements, specify circuit length and location. CONTROLS Low-profile integral occupancy and daylight sensors are available to deliver high performance control in an architecturally pleasing package. Integral occupancy sensor - the sleek Wattstopper FS-205 modular plug-in system utilizes a RJ45 connector, low voltage cord, and power pack. Automatic on/off passive infrared (PIR) occupancy sensing control covers a range of 200 square feet for a specified 30 second to 30 minute time delay with an optional ambient daylight sensing function to hold lights off when specified adequate daylight level is sensed. Factory default time delay of 30 minutes and 120fc light level. Settings can be adjusted at the factory or easily in the field. Integral daylight sensor - the sophisticated Wattstopper F-301 is a low voltage controller using 0-10VC input to automatically dim the electric lighting system based on daylight contribution in a 70 field of view to achieve a target illuminance using a sliding setpoint algorithm. This single zone closed loop daylight harvesting control system utilizes a RJ45 connector, low voltage cord, and power pack. One (1) LSR-301-S setup remote control to adjust target let levels and prevent tampering for maximum energy saving performance is provided per order. Combined occupancy and daylight sensing is achieved using both the FS-205 and F-301 for more versatile control functionality including automatic on/off occupancy and daylight dimming response. Other manufacturer controls may be available for product integration, contact factory. MOUNTING Bottom and irect Wall mounting is AA compliant. Fixture mounts directly to surface requiring field drilled mounting and power feed holes. Factory pre-drilled holes can be drilled and tapped for ½ chase nipple, submit dimension requirements when ordering. Mullion Blocks are used to mount fixture to a horizontal or vertical window mullion and can also be used to offset fixture from wall. ½ or 1 deep milled aluminum blocks are available standard, 3/8 and 2 deep blocks also available upon request. (2) blocks provided for fixtures 8ft or less, fixtures larger than 8ft provided with (3) blocks every 12ft. Quantity of power feed and non power feed blocks provided as required. Fixture mounting requires field drilled mounting and power feed holes. Factory pre-drilled holes can be drilled and tapped for ½ chase nipple, submit dimension requirements when ordering. Partial /Full Span mounting conditions utilize special expansion joint end caps to mount fixture to wall (blocking required) and feed power through the end cap, specify end feed location. Additional attachment hardware provided as required depending on partial span condition. Provide architectural details at time of ordering for inclusion in factory shop drawings; field verified dimensions required for full span mounting.

TECHNICAL ATA STRUCTURE Robust, high quality 60% recycled aluminum extruded housing. 0.040 thick aluminum internal gear trays. iecast 3/8 thick aluminum end caps. Aluminum joiner brackets. 5 lbs/ft approximate fixture weight. FINISH Electrostatically applied powder coat finish. Standard finish options include alightanium, satin white, and satin black. Other colors and custom finish options available, specify RAL# or contact factory regarding custom finish requirement. LISTING UL/CUL rated for amp Locations. Tested in accordance with UL 1598 and certified to CEC/CSA C22.1, NEC, ANSI/NFPA 70, and NOM-001-SEE. UL Wet location label available. Complies with UL definition of wet locations to prevent accumulation of water on live parts, electrical components, or conductor not identified for use in contact with water through the provision of weep holes. Neoprene gaskets provided at end caps to prevent ingress of liquids. For continuous fixture runs, wet location joiner blocks are provided. Waterproof connector to be provided by others. Installing contractor responsible for properly sealing and waterproofing all field drilled and power feed locations. WARRANTY Limited defect-free manufactured equipment warranty provided under normal use and proper storage for a period of one (1) year. LE products (LE boards and drivers) will be covered for a period of five (5) years. Wet location fixtures are not recommended for extreme wet weather conditions and must be installed according to factory drawings; there is a modified warranty for LE components installed in applications not in accordance with factory recommendations/drawings. Please refer to full terms and conditions on our website.