HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

Similar documents
HE420A Steam Power Humidifier

HE360A,B Powered Flow-Through Humidifier

HE360 Powered Flow-Through Humidifier

HE365A,B Powered Flow-Through Humidifier with

HE365A,B Powered Flow-ThroughHumidifier with

HE365A,B Powered Flow-ThroughHumidifier with JI

T8011F Flush Mount Programmable Heat PumpThermostat OWNER S GUIDE

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

T4700 Chronotherm Electronic Programmable Line Voltage Thermostat OWNER S GUIDE

CT500 Electronic Thermostat

UV100E Ultraviolet Air Treatment System

Heating/Cooling Thermostat and Subbase Package T8196A/Q682A

CT2700 An Electronic Round Programmable Thermostat

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

HE120, HE160 Humidifier Installation Kit

HE360 Humidifier Installation Kit

Heat Recovery Ventilation Systems OWNER S GUIDE

Home and Building Control Home and Building Control Helping You Control Your World

Programmable Load Management Thermostat

1 PREPARATION 2 THERMOSTAT MOUNTING DIMENSIONS. CT70A Heat Pump Thermostat. Your Honeywell Thermostat. Recycling Notice. Do-It-Yourself Models

IMPORTANT INSTRUCTIONS FOR FAN-FORCED HEATER USE

Operating Manual. PRO 1000 Series EFS-01. Non-Programmable Thermostat

Electrode Steam Homeowner s Manual HOMEOWNER S OPERATING MANUAL EFS-01

HE365A,B Powered Flow-Through Humidifier

Must be installed by a trained, experienced technician

HE220, HE260 Humidifier Installation Kit

F112A,C; F113A,C Portable Air Cleaners

UV100A Ultraviolet System

CT2800 Programmable Thermostat

T8131C Programmable Thermostat OWNER S GUIDE

MagicStat CT3300 Programmable Thermostat

UVIOOAUltravioletSystem

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

Honeywell CT3550 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

CT1500, CT1501, CT1502, CT1503

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

Comfort, Energy & Health Solutions

Electronic Thermostat

Honeywell/36. Programmable Thermostat OWNER S GUIDE

Honeywell CT3611 PROGRAMMABLE THERMOSTAT. Table of Contents OWNER S GUIDE

F58F ELECTRONIC AIR CLEANER

H1008A,D Automatic Humidity Controls

Owner s Manual For Models 400, 500, 600 & 700

Owner s Manual. Humidifiers. For Models 350, 360, 400, 400M, 500, 500M, 600, 600M, 700 & 700M

Portable Air Cleaner. Owner s Manual. The Science of Clean Air READ AND SAVE THESE INSTRUCTIONS. For Model 1606X Series Air Cleaner JULY

T6 Pro Hydronic. User Guide. Thermostat controls. Customer assistance. Programmable Thermostat

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER'S MANUAL Read and save these instructions before use.

Continue to next pages for Template instructions, Owners Guide, Humidistat Instructions.

Safety, Installation, and Operation Manual

Owner s Manual. For Models 350, 360, 400A, 500A, 500M, 600A, 600M, 700A & 700M. Includes Safety & Operating Instructions and Warranty Information

T8602C Chronotherm IV Deluxe Programmable Thermostats

READ AND SAVE THESE INSTRUCTIONS AUTOMATIC HUMIDIFIER. The Best Cure For Dryness OWNER S MANUAL FOR MODELS 448, 558, 568, 600, & 700

Model 1870F Dehumidifier Installation and Operating Manual

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

Installation Guide. Dehumidification. Fresh Air Ventilation. Compact Size. Energy Efficient. DH90 Whole House Dehumidifier

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8600D Chronotherm IV Deluxe Programmable Thermostats

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

OWNER S MANUAL READ AND SAVE THESE INSTRUCTIONS MODELS 4000, 5000, 6000 & 7000 HUMIDIFIERS. Includes Safety, Operating and Maintenance Instructions

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

Model 1850F Dehumidifier Installation and Operating Manual

ELECTRIC STOVE MODEL CGESS SAFETY INFORMATION AND OPERATION MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCS. Voltage rating: 115V~60Hz Power rating : 1400W

T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

breeze easytm model # F100-1W

GL-DEH Series Portable Dehumidifier Operating Instructions

DEHUMIDIFIER. User Manual 50BT, 70BT

Portable Dehumidifier with Internal Pump

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

C554A Cadmium Sulfide Flame Detector

SLIDER CASEMENT AIR CONDITIONER

T8611M Deluxe Programmable Heat Pump Thermostats

ELECTRIC FIREPLACE OWNER S MANUAL

OWNER S GUIDE F52F ELECTRONIC AIR CLEANER. Copyright 1998 Honeywell Inc. All Rights Reserved

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Portable Dehumidifier

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS. The Best Cure For Dryness OWNER S MANUAL

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

BASEBOARD MICATHERMIC HEATER

MODEL HUM HUMIDIFIERS

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

OWNER S MANUAL. 4 GALLON OUTPUT PER DAY COOL MOISTURE HUMIDIFIER Model HCM-2051 Series. * Output dependent on room temperature and humidity.

Deluxe Programmable Thermostats

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

CAUTION CAUTION HCWB2 & HCWP2 SERIES IAQ HUMIDIFIERS USER S MANUAL FOR HCWB2 AND HCWP2 HUMIDIFIERS. Table Of Contents

ROTARY CONTROL AIR CONDITIONER

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

AIR CONDITIONER ELECTRONIC CONTROL

T7100D Microelectronic Conventional Thermostat

PLEASE READ BEFORE USE AND SAVE. Ultrasonic. with Ionization. INSTRUCTION MANUAL MODEL HUNi

Preface. Overview. The above illustration shows a typical three zone Aprilaire Zoned Comfort Control system.

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Air Purifier. User s Guide. Important! Oreck Air Purifier with HEPA Filtration. Read this manual carefully, and keep for future reference.

T6984F,G Electronic Floating Control Thermostats

T4398A,B Precision Electric Heating Thermostat

Transcription:

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE U.S. Registered Trademark Copyright 1998 Honeywell Inc. All Rights Reserved 69-1112-1

WELCOME... to the comfortable world of humidified air. With your Honeywell humidifier you will notice a decrease in dry skin, scratchy throats and irritated nasal passages that aggravate allergies and asthma. You ve also taken the first step to stopping the zapping created by walking on your carpet and touching your TV, computer, metal door knob or your pet. You can even put away your glue bottle because your furniture and woodwork will stop drying out. Congratulations! You have just made a great investment in your home comfort. 69-1112 1 2

TABLE OF CONTENTS Operating Your Humidifier... 4 How Your Humidifier Works... 5 Maintaining Your Humidifier... 5 Checking Your Humidifier Operation... 7 Troubleshooting Your Humidifier... 8 Adding Perfect Climate for Comfort and Convenience... 9 Warranty... 10 3 69-1112 1

OPERATING YOUR HUMIDIFIER Your Honeywell HE420A and HE460A Humidifiers are controlled by the H908A Convertible Humidity Control that is installed either on the interior wall in the living area or return air duct. Choose the humidity control setting using the combination relative humidity/outdoor temperature setting scale on your humidity control. Match the dial setting to the outdoor temperature for optimizing the humidity level while reducing the moisture condensation on your windows. The table below can also be used to adjust the humidity control to the recommended setting. H908A M13155 At Outside Temperature Recommended Setting At Outside Temperature Recommended Setting -20 F (-29 C) 15 +10 F (-12 C) 30-10 F (-23 C) 20 +20 F (-7 C) 35 0 F (-18 C) 25 Above 20 (-7 C) 40 NOTE: As the outside temperature drops, the recommended setting is lowered to accommodate the effects of dewpoint. These settings should reduce the accumulation of moisture and ice on your windows and in other areas of your home. Some indoor activities such as cooking, showering and clothes drying can cause excessive levels of humidity and start the accumulation of moisture on your windows. NOTE: If this condition persists for more than a few hours, set the humidity control to the lowest setting to turn off the humidifier. If the condition does not improve, ventilate your home to remove the moisture. Your Honeywell HE220B and HE260B Humidifiers are controlled by the Honeywell H1008 Automatic Humidity Control with HumidiCalc+ Software. The H1008A automatic humidity control is mounted in the return air duct where it can be exposed to the air stream of the return air. The HumidiCalc+ M12817 Software inside your automatic humidity control is designed to automatically adjust the humidity level based on indoor temperature and humidity, inferred or measured outdoor temperature, and the setting of the frost factor dial. The frost factor allows for variations in furnace size, window insulation and average daily climate temperature. The Automatic Humidity Control with HumidiCalc+ Software requires an initial adjustment period. Set the frost factor dial on 5 and use the following table to adjust the frost factor only one setting at a time increasing the dial setting if you feel you need more humidity, or reducing the setting if you see moisture on the inside of your windows. For more precise humidity adjustment, set the frost factor between dial settings. Allow two days for the humidity level to subside before making further adjustments. Once you have tuned in the proper setting, you should never have to adjust it again. HumidiCalc+ Software takes over and makes any future adjustments caused by varying outdoor temperatures, thus reducing moisture buildup on windows while maintaining the optimal humidity level. 69-1112 1 4

R 240 Volts, 1 Phase, 60 Hz, 1500 Watts Danger: Possible electric shock and burn. Disconnect electrical supply and let water cool before servicing or cleaning. Listed 42U8 Listed 42U8 Honeywell, Inc. 1885 Douglas Drive. Minneapolis, MN 55422-3992 R HE420A,B AND HE460A,B STEAM POWER HUMIDIFIERS Humidity Level Insufficient humidity Condensation on windows Recommended Adjustment Increase the frost factor dial by one setting. Decrease the frost factor dial by one setting. HOW YOUR HUMIDIFIER WORKS Your Honeywell humidifier uses the principle that hot water creates moist air and as the moist air circulates, the relative humidity rises. Your humidity control monitors the relative humidity and activates the humidifier accordingly. When the humidity control calls for humidity, the humidifier underwater heater starts heating the water in the humidifier reservoir. When the water is warm enough, the humidifier activates a relay that turns on the furnace fan. The warm dry air from the furnace picks up the moist air and circulates it through the home. The fan continues to circulate the air until the water cools down and then turns off the fan. Humidified air feels warmer and more comfortable so you may be able to lower your thermostat heating setpoint and save money on your heating fuel bills. The end result is that your humidifier gives you a comfortable environment that is also energy efficient. MAINTAINING YOUR HUMIDIFIER A regular maintenance program prolongs the life of your humidifier and provides a more comfortable home. Frequency of cleaning depends on the condition of your water. You can use either hard or soft water in your humidifier, but hard water mineral deposits are more difficult to clean than soft water deposits. HEATER FAN CONTROL SAFETY FLOATSWITCH Honeywell Humidifier Model HE460 For Residential Use Only FLOAT H1008A HUMIDITY CONTROLS VALVE ARM RESERVOIR OVERFLOW WATER FEED TUBING INLET DRAIN H908A M13154 5 69-1112 1

Every 1 to 4 Months (Depending on Water Quality) WARNING Voltage Hazard. Can cause electrical shock and equipment damage. Disconnect power and shut off water supply before installing or servicing. IMPORTANT Never oil any part of the humidifier. Use the following procedure to clean your Honeywell humidifier: 1. Unplug the humidifier and fan control. 2. Disconnect the wires from the humidity control external screw terminals. 3. Turn off the water supply. 4. Disconnect the water feed tubing at the float valve. 5. Disconnect the overflow at the humidifier. IMPORTANT Allow water to cool before continuing. 6. Use a quarter and very slowly turn the automatic flushing timer indicator clockwise. This will activate the drain valve and allow water to flow from the humidifier reservoir to the drain. SLOT FOR COIN COIN TURN CLOCKWISE VERY SLOWLY M10552 7. Remove the humidifier from the mounting. 8. Use running tap water to flush loose minerals from the reservoir. 9. Carefully rub minerals off of the float, heater and safety float switch. NOTE: Steel wool or other scouring pads can be used on the reservoir walls and other parts. 10. Remove the valve arm by pulling out the cotter pin attachment. Inspect the arm for mineral buildup and deterioration. NOTES: Replace the float valve when it shows any signs of deterioration. 11. Reset the water level: The float valve should shut off the water at 2-3/8 in. (60 mm). CAUTION Flooding Hazard. Inadequate support of the float arm can lead to valve seat damage resulting in water leakage. Support the float arm during adjustment. a. Set the humidifier reservoir on a level surface. b. Attach the water feed line and allow the unit to fill until the float valve shuts off the incoming flow of water. The water level should be between 2-1/4 in. (57 mm) and 2-1/2 in. (64 mm) deep. If water level is correct, skip to step 12. c. Adjust the water level in small increments. Raise the water level by pushing down on the center of the float arm. Lower the water level by pressing the float down with one hand and pulling up on the center of the float arm with the other hand. 69-1112 1 6

TO RAISE WATER LEVEL TO LOWER WATER LEVEL PUSH DOWN HOLD DOWN PUSH UP d. Verify the water level by removing enough water to allow the float valve to automatically fill and shut off the water. 12. Remount the humidifier. 13. Reconnect all plumbing connections. 14. Reconnect all electrical connections. 15. Verify the humidifier operation by following the steps in the Checking Your Humidifier Operation section. End of Humidification Season Clean and shut off the humidifier at the end of the heating season. Use the Every 1 to 4 Months section, steps 1 through 10 and step 12, to shut down for the season. IMPORTANT Be sure the humidifier power is off and there is no water in the humidifier when you are done. Vacation When you leave on vacation, turn off the humidifier water supply and your humidity control. Turn on the humidifier water supply and reset your humidity control when you return. CHECKING YOUR HUMIDIFIER OPERATION After winter startup or maintenance, use the following steps to check the humidifier operation: 1. Turn on the humidifier water supply. 2. Be sure the humidifier has power, and plug in the humdifier. 3. Turn the H908A Convertible Humidity Control to the highest setting or the H1008A Automatic Humidity Control to the Test position. The underwater heater starts to heat the reservoir water. NOTE: M10581 The H1008A Automatic Humidity control stays in the test mode for thirty minutes. After thirty minutes, the control automatically resets to the maximum frost factor setting. If system checkout has not been completed in thirty minutes, the test mode can be extended by turning the dial back to one of the dial settings and then returning it to the test mode. 4. Check that the furnace blower turns on to circulate the moist air. The blower may take as long as fifteen minutes before it turns on. 5. Reset the H908A Convertible Humidity Control to a comfortable setting, or return the H1008A Automatic Humidity Control to the desired frost factor setting, for automatic operation. 7 69-1112 1

TROUBLESHOOTING Problem What To Look For What To Do Low humidity High humidity Furnace blower not operating. Rapid air changes. Drafts (cold air is dry and is an added load for the humidifier). Condensation on walls. Heavy condensation on windows. Reset circuit breaker or check for blown fuse. Check that the furnace power is on. Check all external wiring connections. Check the humidity control setting. Call a professional heating contractor. Keep doors and windows closed. Close fireplace damper when not in use. Keep exhaust fan running time to a minimum. Seal around doors and windows. Turn off the humidity control and water until condensation is completely evaporated. Turn humidity control down low enough to eliminate condensation caused by moisture from bathing, mopping, cooking, etc. If moisture persists, more ventilation is needed. 69-1112 1 8

Adding Perfect Climate CONTROLS FOR COMFORT AND CONVENIENCE How it works... THE HONEYWELL HUMIDIFIER IS ONE PART OF A PERFECT CLIMATE INDOOR ENVIRONMENT THAT PROVIDES TOTAL INDOOR COMFORT. IT MAKES YOU FEEL BETTER, AND ALLOWS YOU TO LIVE AND WORK IN A MORE COMFORTABLE ENVIRONMENT. HOME VENTILATION SYSTEM HONEYWELL FRESH AIR HUMIDISTAT CONTROL HONEYWELL CHRONOTHERM lv PROGRAMMABLE THERMOSTAT CONDITIONED AIR RETURN AIR CONDITIONED REGISTER AIR SUPPLY AIR REGISTER OPTIMAL EFFICIENCY AIR CONDITIONER OR HEAT PUMP HUMIDIFIER OPTIMAL EFFICIENCY FORCED AIR FURNACE COLD AIR RETURN STALE AIR FROM BATHS HONEYWELL FRESH HOME AIR TO VENTILATION HOME SYSTEM HONEYWELL ELECTRONIC AIR CLEANER STALE AIR EXHAUST FRESH AIR INTAKE M12302 1. Honeywell Perfect Climate Comfort Center controls or Chronotherm IV Programmable Thermostats. 2. Honeywell F35 media air cleaner or F50 electronic air cleaners. 3. Honeywell humidity controls. 4. Honeywell humidifiers. 5. Honeywell home ventilation systems. Describing Perfection The most convenient, most energy efficient, cleanest, healthiest and most comfortable indoor environment possible today! Perfect climate is achieved when the five core components of a home s climate system work together: Optimal efficiency heating and cooling equipment, Precise, programmable temperature control, Effective indoor air quality control, Controlled humidity, Proper ventilation and air distribution. Contact your local Perfect Climate dealer for an evaluation of your home. 9 69-1112 1

WARRANTY Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is defective or malfunctions, Honeywell shall repair or replace it (at Honeywell s option) within a reasonable period of time. If the product is defective, (i) return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or (ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage prepaid, to the following address: Honeywell Return Goods Dock 4 MN10-3860 1885 Douglas Drive Golden Valley, MN 55422 This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer. Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this limitation may not apply to you. THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRAN- TIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. If you have any questions concerning this warranty, please write to Home and Building Control Customer Relations, Honeywell, 1985 Douglas Drive North, Minneapolis, MN 55422. In Canada, write Retail Products ON15-02H, Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9. 69-1112 1 10

11 69-1112 1

Home and Building Control Honeywell Inc. Honeywell Plaza P.O. Box 524 Minneapolis, MN 55408-0524 69-1112 1 J.S. Rev. 5-98 Home and Building Control Honeywell Limited-Honeywell Limitée 155 Gordon Baker Road North York, Ontario M2H 3N7 Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. 69-1112 1 12 www.honeywell.com/yourhome