Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

Similar documents
Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

HEATING. Anticondensation Heaters

VA G 052 S

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

Multi Inverter Air Conditioning Condensing Units - Summary

Control THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL INDOOR/OUTDOOR

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

VERAK KRIO. Industrial cabinets with integrated air-conditioning unit.

SYSTEMS GENERAL CATALOGUE

ROTARY SCREW COMPRESSOR CSM MAXI 7, HP

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

G /6000 BTU/Hr. 1172/1758 Watt

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

GENESIS Indoor Air Conditioners

Manual For Panel Air Conditioner. Table of Contents

Refrigerant Cycle. Performance Data 1) Electric. Acoustic Pressure Level. Compressor. Connections, Dimensions

G /6000 BTU/Hr. 1172/1758 Watt

N Volt 1800 BTU/Hr. 527 Watt

We optimize performance.

N Volt 1800 BTU/Hr. 527 Watt

Fan heater Panther Powerful fan heater for large premises

Blue Box Epsilon Echos +

design consulting distribution Compressors 2013 range pneutechgroup.com

Top-Mount Air Conditioners

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

Excellent performance with low operating costs, Energy saving and environmentally friendly

Inverter Ducted Air Conditioners

NEMO A Split-system liquid chillers for indoor installation. Cooling Capacity: 5 26 kw

Quality Enclosures. Service Excellence.

Comfort Air Curtains with in-built dynamic advertising

SCREW COMPRESSORS - ELECTRIC

D E F E N D E R Datacom Cabinets

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

Rapid. Suspended Warm Air Heater. Caring for the environment!

Table of Content

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

ROTARY SCREW COMPRESSOR MSM MAXI 5,5-7, kw

Molex Premise Networks Corporate Headquarters Harvard, MA Tel: Tel: Fax:

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

AVC085 AVC / AVC / AVC / AVC / AVC / AVC085.21

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

ACCESSOIRES ELECTRICAL ACCESSORIES

DESIGN & TECHNICAL MANUAL

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

GRF Series Non-Cycling Refrigeration Dryers ANDARD ELECTRONIC DRAIN STANDARD ELEC SS EXPANSION VALVE F PRESSURE DEWPOINT

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

Colorado SCR. Electric Towel Radiator Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

DESIGN & TECHNICAL MANUAL

Mobile climate solutions

Technical Information HXV - HRV Ventilation

ST Wiring diagram. Product description. Four-stage controller. Order number

Technology that works fast. Inverter Ducted Systems

Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8

USE AND MAINTENANCE MANUAL

Technology that works fast. Inverter Ducted Systems

Technology that works fast. Inverter Ducted Systems

Issue5 07/13 USERS MANUAL IN-LINE MIXED FLOW

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

Rotary Screw Compressors. SK Series With the world-renowned SIGMA PROFILE Flow rate 0.53 to 2.70 m³/min, Pressure 5.5 to 15 bar

DESIGN & TECHNICAL MANUAL

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

INSTALLATION AND OPERATING INSTRUCTIONS General operating instructions for sample gas conditioner Model: MAK 6

NEXT EVO DXR410A NEXT EVO DX NEW SOFTWARE. rcgroupairconditioning

Mobile Type Air Conditioner

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Condensing Units CUS 15-60

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Advance Split

ASTRALPOOL HEAT PUMP CATALOGUE

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Heaters, Thermostats and Hygrostats

Cabinet Cooler Systems

Room thermostat with 24-hour time switch and large LCD

DUCTED. SYSTEMS Enhanced for superior comfort and smart energy management by AirTouch 3. fordanddoonan.com.au 1800 AIR CON

8000 Series Programmable & Non-Programmable Thermostats for Heat/Cool Applications

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

DESIGN & TECHNICAL MANUAL

Mobile climate solutions

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

LAF 50 / 100 / 150. Condensing dehumidifiers for professional use. Accessories. Design. Approvals LAF

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

nemo a hp rcgroupairconditioning R410A

Table 1. Serie of Digital Room Thermostats.

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Transcription:

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

AIR CONDITIONING Air Conditioning Models and power The range of air conditioners ALFA ELECTRIC includes several productions depending on voltages and different type of thermostat mounted. The code varies about voltage and control instrumentation. Low maintenance ALFA ELECTRIC air conditioners require little maintenance on all models through the adoption of heat exchanger with a pitch between the ns is not less than mm. The ns are treated to reduce the adhesion of dirt. Rotary Compressor ALFA ELECTRIC air conditioners are distinguished by the adoption on most models of rotary compressors. This type of compressors, unlike the more common alternative compressors allowed to contain the clutter in favour of a greater distance between inlet hot air from the context and delivery of fresh air into the framework. The greater distance allows the reduction of the phenomenon of by-pass, using a greater amount of fresh air produced. Outdoor version These units have a special cover designed to protect internal components, a condenser fan controller in according to the condensation pressure and pressure controller for the safety of compressor. On request is available a heater band to protect compressor in low ambient temperature. CODE COMPOSITION AVC 0. 00 1 _ SERIES POWER SUPPLY COOLING CAPACITY Power AVC Wall mount indoor installation ARC Roof mount AVE Wall mount outdoor installation ARK Rack 19" mount INSTALLATION _ Standard as in data sheet (external) B Internal built in S semi-reccess CONTROL SYSTEM 0 mechanic thermostat 1 digital thermostat 00 2VAC/1ph/50-60Hz 01 115VAC/1ph/50-60Hz 02 VAC/2ph/50-60Hz 41 VAC/3ph/50Hz 42 VAC/3ph/60Hz 43 VAC/3ph/50Hz - 460VAC/3ph/60Hz Digital thermostat digital thermostat allows to implement various control operations: 1. setting ignition temperature compressor 2. setting temperature compressor shutdown 3. Set delay on / off the compressor in terms of temperature 4. Setting the standard period of the compressor to avoid the phenomenon of intermittent on/off. This phenomenon is very detrimental to the proper operation of the air conditioner. 5. Setting the maximum value allowed for the overcoming of the maximum temperature in the cabinet, after which the thermostat emits an alarm 6. Setting the delay time of the alarm switch Less weight and less vibrations The rotary compressor also reduces the weight of the unit with obvious bene ts in the transport, handling and installation of the machine. The lower vibrations due to a lower inertia of the moving parts make this component quiet and durable. The rotary compressor has considerable advantages over the alternative compressor: among them being a bigger isentropic ef ciency mainly due to different internal cooling which favors compression. The absence of valves in suction and dead volumes, typical of alternative systems, reduces the loss of gas pressure. AIR CONDITIONER SELECTION WITH WATT-A-CALCULATOR Watt-a-Calculator is a selection software that machtes the best model to the speci c customer application. Watt-a-Calculator is available on Alfaelctric web site. Please visit it and follow the easy instructions to nd the solutions for you. www.alfalectric.com/wattcalc 4

Air Conditioning 0 W AVC 0 WALL MOUNT AIR CONDITIONER 500 0 0 0 250 0 150 100 25 50 10 275 160 112 Features Unit AVC0.000 AVC0.001 AVC0.010 AVC0.011 AVC0.0 AVC0.021 Power supply V/Hz 2V/1ph/50-60 115V/1ph/50-60 V/2ph/50-60 Dimensions HxWxD mm 4x280x170 Cooling capacity AA W 0/370 Cooling capacity AA50 W 0/2 Max current A 1.5/1.6 3/3.2 0.9/1 Delayed fuse A 4 6 4 Absorbed electric power AA W 290/3 Absorbed electric power AA50 W 3/0 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+69/+113) Noise level db(a) 60 Weight (with packaging) kg 15(16) 17(18) 17(18) Package Dimension H x W x D mm 470 x 3 x 280 Colour - RAL 70 Versions Outdoor AVE0.000 AVE0.010 AVE0.0 Flow diverter* FD0 4 175 219 134 172 394 426 280 170 4xØ9 105 5

Air Conditioning 850 W AVC 085 WALL MOUNT AIR CONDITIONER 1100 1000 900 700 600 500 0 25 50 Features Unit AVC085.000 AVC085.001 AVC085.010 AVC085.011 AVC085.0 AVC085.021 Power supply V/Hz 2V/1ph/50-60 115V/1ph/50-60 V/2ph/50-60 Dimensions HxWxD mm 6x5x210 Cooling capacity AA W 850/900 Cooling capacity AA50 W 625/650 Max current A 2.65/2.75 5.3/5.4 1.65/1.75 Delayed fuse A 6 10 4 Absorbed electric power AA W 490/5 Absorbed electric power AA50 W 600/6 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 62 Weight (with packaging) kg 23(24) (31) (31) Package Dimension H x W x D mm 690 x 3 x 250 Colour - RAL 70 Versions Outdoor AVE085.000 AVE085.010 AVE085.0 Flow diverter* FD085 0 2 170 6 190 138 285 6 285 100 3 5 210 6xØ8 285 6

Air Conditioning 10 W AVC 1 WALL MOUNT AIR CONDITIONER 1700 1600 1500 1 10 10 1100 1000 900 25 50 Features Unit AVC1.000 AVC1.001 AVC1.010 AVC1.011 AVC1.0 AVC1.021 Power supply V/Hz 2V/1ph/50-60 115V/1ph/50-60 V/2ph/50-60 Dimensions HxWxD mm xx2 Cooling capacity AA W 10/1500 Cooling capacity AA50 W 1150/10 Max current A 3.7/4.2 7.4/8.4 1./2.1 Delayed fuse A 6 10 4 Absorbed electric power AA W 600/6 Absorbed electric power AA50 W 710/760 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 65 Weight (with packaging) kg 37(38) 49(50) 49(50) Package Dimension H x W x D mm 875 x 5 x 280 Colour - RAL 70 Versions Outdoor AVE1.000 AVE1.010 AVE1.0 Flow diverter* FD1 395 3 180 126 796 498 0 6xØ10 2.5 2 141 0 292.5 7

Air Conditioning 00 W AVC 0 WALL MOUNT AIR CONDITIONER 2 20 00 1 1600 1 10 1000 25 50 3 141 180 Features Unit AVC0.000 AVC0.001 AVC0.010 AVC0.011 AVC0.0 AVC0.021 Power supply V/Hz 2V/1ph/50-60 115V/1ph/50-60 V/2ph/50-60 Dimensions HxWxD mm 1000xx2 Cooling capacity AA W 00/2100 Cooling capacity AA50 W 10/1250 Max current A 6.6/6.9 13/13.8 3.3/3.5 Delayed fuse A 10 16 6 Absorbed electric power AA W 1060/1100 Absorbed electric power AA50 W 12/10 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 70 Weight (with packaging) kg 49(50) 57(58) 57(58) Package Dimension H x W x D mm 1070 x 460 x 265 Colour - RAL 70 Versions Outdoor AVE0.000 AVE0.010 AVE0.0 Flow diverter* FD0 1000 473 225 180 344 477 460 1000 6XØ8 2 8

Air Conditioning 2 W AVC 0 WALL MOUNT AIR CONDITIONER 00 0 00 00 2500 00 1500 1000 500 25 50 286 7 1500 180 2 680 1498 7 170 580 385 Features Unit AVC0.431 Power supply V/Hz V/3ph/50-460V/3ph/60 Dimensions HxWxD mm 1500xx255 Cooling capacity AA W 2/2950 Cooling capacity AA50 W 2150/23 Max current A 2.2 Inrush current A 11/11.8 Absorbed electric power AA W 1550/1790 Absorbed electric power AA50 W 1780/50 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 70 Weight (with packaging) kg 65(67) Package Dimension H x W x D mm 1610 x 4 x 290 Colour - RAL 70 6XØ8 255 290 9

Air Conditioning 3 W AVC WALL MOUNT AIR CONDITIONER 6500 6000 5500 5000 00 0 00 00 2500 25 50 Features Unit AVC.431 Power supply V/Hz V/3ph/50-460V/3ph/60 Dimensions HxWxD mm 1500xx255 Cooling capacity AA W 3/3980 Cooling capacity AA50 W 2880/3160 Max current A 2.7 Inrush current A 14.5/15.1 Absorbed electric power AA W 80/24 Absorbed electric power AA50 W 2410/2 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 70 Weight (with packaging) kg 65(67) Package Dimension H x W x D mm 1610 x 4 x 290 Colour - RAL 70 286 7 1500 180 2 680 580 385 1498 7 6XØ8 170 255 290 10

Air Conditioning 500 W ARC 050 ROOF MOUNT AIR CONDITIONER 900 700 600 500 0 0 100 25 50 Features Unit ARC050.000 Power supply V/Hz 2V/1ph/50-60 Dimensions HxWxD mm 250x0x500 Cooling capacity AA W 500/5 Cooling capacity AA50 W 360/380 Max current A 2/2.2 Inrush current A 6.9/7 Absorbed electric power AA W 360/4 Absorbed electric power AA50 W 4/5 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 67 Weight (with packaging) kg 22(23) Package Dimension H x W x D mm 495 x 6 x 3 Colour - RAL 70 385 55 4xØ9 Ø143 Ø 50 250 0 228 125 17 50 250 500 0 85 187 68 1 11

Air Conditioning 1000-1500 W ARC 100/150 ROOF MOUNT AIR CONDITIONER 00 00 2700 1 2 1600 2100 1 1 10 1500 1000 10 900 600 600 0 0 ARC150 ARC100 25 50 Features Unit ARC100.000 ARC150.000 Power supply V/Hz 2V/1ph/50-60 2V/1ph/50-60 Dimensions HxWxD mm 0xx600 0xx600 Cooling capacity AA W 1000/1060 1460/15 Cooling capacity AA50 W 760/790 1090/11 Max current A 2.8/3.4 4/4.8 Inrush current A 11.5/12.6 16.3/13.5 Absorbed electric power AA W 580/670 790/9 Absorbed electric power AA50 W 7/8 970/1150 R134a Operating temperature (ambient) C ( F) +/+55 (+68/+131) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) +/+ (+68/+113) Noise level db(a) 70 70 Three-pole connector IP54 IP34 Weight (with packaging) kg 37(39) 37(39) Package Dimension H x W x D mm 5 x 755 x 510 5 x 755 x 510 Colour - RAL 70 RAL 70 CE.5 336.5 600.5 2 18.5 7xØ9 60 0 134 110 387.5 7.5 557.5 Ø22 255 600 137.5 104 412.5 156 18.5 12

Air Conditioning 00 W ARC 0 ROOF MOUNT AIR CONDITIONER 30 2900 2600 00 1700 1 1100 25 50 Features Unit ARC0.000 Power supply V/Hz 2V/1ph/50-60 Dimensions HxWxD mm xx Cooling capacity AA W 00/2110 Cooling capacity AA50 W 1500/1570 Max current A 5.1/6.2 Inrush current A 23.6/24.1 Absorbed electric power AA W 10/1250 Absorbed electric power AA50 W 1290/15 Operating temperature (ambient) C ( F) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) Noise level db(a) 65 Weight (with packaging) kg 54(57) Package Dimension H x W x D mm 480 x 865 x 4 Colour - RAL 70 107 186 107 80 3 2 92 6xØ9 Ø22 248 72 80 27 60 60 27 13

Air Conditioning 2-3 W ARC 0/ ROOF MOUNT AIR CONDITIONER 5500 0 5000 3700 00 3 3100 0 2 00 2500 00 20 2500 1900 00 1600 10 ARC ARC0 25 50 Features Unit ARC0.410 ARC.410 Power supply V/Hz V/3ph/50 V/3ph/50 Dimensions HxWxD mm xx xx Cooling capacity AA W 2 3 Cooling capacity AA50 W 2110 28 Max current A 2.2 2.7 Inrush current A 11 14.5 Absorbed electric power AA W 11 1 Absorbed electric power AA50 W 1380 17 R134a Operating temperature (ambient) C ( F) +/+55 (+68/+131) +/+55 (+68/+131) Operating temperature (enclosure) C ( F) +/+ (+68/+113) +/+ (+68/+113) Noise level db(a) 65 65 Three-pole connector IP54 IP34 Weight (with packaging) kg 60(62) 63(65) Package Dimension H x W x D mm 480 x 865 x 4 480 x 865 x 4 Colour - RAL 70 RAL 70 CE 107 186 107 80 3 2 92 6xØ9 Ø22 248 72 80 27 60 60 27 0 Roundhill Dr. Rockaway, NJ 07866 Tel: 973-586-2500 www.norstat.com