TECOM SYSTEMS NETWORK MASTER

Similar documents
IEI NETWORK INTERFACE MODEL TS2040

Fratech Multipath-IP

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

Challenger Version 8 Programming Relays.

CC408. Quick Reference Guide Solution 880

PERMACONN PM1030 Includes DI300. Installation Manual

Multiple Battery Cabinets Dual-Lite TRN. External Maintenance Switch Configuration Options. External Maintenance Switch Options

T4000 Security Communicator

CC488. Quick Reference Guide Solution Ultima 880

Contact ID as of 2/2/2015

Alarm Control Panel WIC-16Z4P WIC-5Z2P. Installation & Operation User Manual

SOFTWARE VERSION 2.20 CONTROL PANEL RESET:

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

User Manual Doc.Ref : EVO-KNX-UM. EVO-KNX Paradox KNX Interface ELAUSYS EVO-KNX. KNX Interface for Paradox alarm system. User Manual.

SOFTWARE VERSION 2.20 CONTROL PANEL RESET: Installer lock must be unlocked. (Address 255: enter any value other than 147)

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Summit 3208GLD USER MANUAL. Electronics Line

System Manual W A R N I N G. PC6O1O Software Version 2.1

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

IGD.CO.UK

See the table on the following Page for full descriptions of each Pin Type.

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

DS7400Xi Addressable Control/ Communicator

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

Fire control panels FC726 FC726-XA

CA60Plus. Installation manual

APPLICATION DATA SHEET

Challenger10 Administrators Manual

Network Display Unit Installation Instructions

User manual for CPR32-NET network controller

FCD-wire Contents. List of Figures

V1.0. Smart Home Alarm System. User Manual. APP download via QR Code scanning. Please read the manual carefully before using.

HEXA PROGRAMMING: STREAMLINED SECTION PROGRAMMING

Contact ID as of 11/28/2018

Control/Communicator

Section PERIMETER SECURITY SYSTEMS

ADEMCO CONTACT ID REPORTING (revised )


Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Each reader connected to the Challenger LAN system is programmed as an Arming Station.

The Challenger Version 8 User Guide

VAP304 PRO INSTALLATION & OPERATION MANUAL

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Fire control panel detect 3004 plus and accessories

Aritech. Fault Finding Guide. Addressable Fire. FFG2000 Revision 1.6, March

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

VISTA-128FBP/ V128FBP-24 Commercial Fire and Partitioned Burglary Alarm Control Panel

Kwêbeam GSM/Interface/Repeater Module

FieldServer Driver - Serial FS Grinnell TFX Minerva

OVEN INDUSTRIES, INC.

(31/03/05) Version p1. INNER RANGE IQ. Programmer s Manual. Programmer s Manual Inner Range Pty. Ltd. Part Number:

2000 Series. Program Entry Guide. Control Panels

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Networked Access Control Panel. Installation Guide

Flair 500 Series Annunciators

USER CODES. User Codes (1-6 digits) Access Levels + Access Levels. Time Control Address Address Address Address User 1 (Master)

Programming Manual. PC6O1O Software Version 2.1

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

FC700A Fire detection control unit

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

PERMACONN PM1048 v3 3G Install Manual Australia

P2267 NETWORK INTERFACE

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

DiaLog Elite. Quick Reference Guide. Remote Monitoring, Control and. Alarm Notification System. # Enter. 1 Prog. 2 Run. 5 SpkrPh. Ack. Arm.

User manual. KNXgal. version

CONTACT ID REPORT CODES

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Added password for IP setup page : Password must be in IP format!

CC880/LP880, SC8016. Operators Guide Solution-16, Solution-16 Safecom

VISTA-100 Commercial Fire & Burglary Partitioned System

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Quick Programmer s Manual

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Version 1.03 January-2002 USER S MANUAL

MG5000 V2.4 MG5050 V2.4 SP5500 V2.4 SP6000 V2.4 SP7000 V2.4. Programming Guide

BURGLAR ALARM PANEL BS-468

SUPREMATouch. Modular Fire & Gas Detection System

FIRE BRIGADE RESPONSE GUIDE. LoopSense. Fire Alarm Control Panel (AS4428 & AS & 4) Operation & Onsite Programming MAN

HRX Technical Manual. Version 1.2

PROGRAMMING GUIDE SPECTRA CONTROL PANELS V , 1725EX, 1728 AND 1728EX 1755, 1755EX, 1758, AND 1758EX

Components Brochure DX CONNEXION

APPLICATION DATA SHEET

EP364 USER MANUAL ALARM AND MANAGEMENT SYSTEM

SUPREMATouch. Modular Fire & Gas Detection System

Solution-16/ Solution-16 Safecom Installation Manual ISSUE 2.10

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Fire control panels FC360

EC-P Zone Intruder Alarm System

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

DXc Control Panels. DXc1. DXc2. DXc4. Single Loop Control Panel, 230Vac, 2 sounder circuits. Dims 260 x 390 x 147mm (H x W x D)

M2M Services Ltd. RControl Alarm - Installer Manual V 1.0

Transcription:

TECOM SYSTEMS NETWORK MASTER The Tecom Network Master is a cost effective, Dialler Receiver and Direct Line Network Master combined in a single modular unit. HARDWARE The unit consists of a 3RU, 19 inch Rack-mount panel with provision for 13 Eurocard modules. The Eurocard modules are 1 Network Master CPU card and up to 12 Network Master Line Cards. The rack is powered from a separate 12V power supply @ 150mA per Card. (i.e. 2A max.) Connections for Telecom lines and all external equipment are provided on the Backplane. CPU CARD The CPU card is the central controller which processes Line card information and provides RS232 interface ports for Host Computer, VDU terminal and Printer. CARDS The Line cards can be programmed to communicate in either Dialler or Direct Line mode. A maximum of 8 cards can be configured for Direct Line mode. The Line cards support the following formats: TECOM dial up TECOM direct line (with Encryption) ADEMCO High Speed ADEMCO High Speed Checksummed ADEMCO High Speed Extended ADEMCO High Speed Extended Checksummed ADEMCO 4 + 2 Checksummed ADEMCO Contact Point ID Checksummed SYSTEM CONFIGURATION System options, Time and date and Line card options can all be programmed by the operator using the "System Configuration" function. A password must be used to gain access to the System Configuration menu. March 1995 Page 1

TECOM SYSTEMS NETWORK MASTER DIRECT MODE In Direct Line mode each Line card functions as a Multi-drop Network and can therefore accomodate up to 10 Alarm panels or Network Concentrator Links. The Direct Line communications link between the Network Master and the Alarm Panels is fully encrypted using Computational algorithms for added security. The operator can recall the status of a Challenger Alarm panel by selecting any one of 8 Panel recall options:- Summary Status - Provides summary of Alarm, Tamper, Isolated and Unsealed inputs. Area Status - Areas armed or disarmed. Alarm Inputs Unsealed Inputs Tamper Inputs RAS Status (on/off line) Isolated Inputs DGP Status (on/off line) The operator can also use the following Network commands to perform functions on the Challenger Alarm panel:- Access Area Isolate Input Secure Area De-isolate Input Reset Input Other system commands available to the operator are:- Activate Panel - to bring panel on-line. Loop Line - to enable testing of line. Program Key - for encryption key. Dial Number - for dialler back up when Direct line fails. DIALLER MODE In Dialler mode the Line card is automatically able to sense the data format being received. Therefore, any Dialler Line card in the system is able to receive on the Tecom format or any of the Ademco formats available. Data received in any of the formats is processed and converted to Contact ID messages for the Host Computer. The Line cards are able to test the lines that they are monitoring. FRONT PANEL INDICATIONS Front panel indication via LEDs on the cards is provided to indicate system and line status. System LEDs on the CPU card indicate:-power OK -Computer OK -Printer OK -Buffer OK LEDs on the Line cards indicate: -Ring/On line -Data Received -Line Enabled -Line OK March 1995 Page 2

HOST COMPUTER TECOM SYSTEMS NETWORK MASTER Interfacing to the Host computer is via an RS232 port on the rear of the Network Master, using Contact ID format. The baud rate for comms between the Network Master and computer is selectable. VDU A VDU terminal can be connected to the Network Master via an RS232 port on the rear of the unit also. The VDU port is enabled if the computer is off-line, or is not connected, in order to action alarms if required. PRINTER A local printer can be connected to another RS232 port on the rear of the unit to log events. The printer port can be enabled and disabled from the Host Computer or VDU terminal. NETWORK LINK The Network Concentrator Link is a fully self contained unit providing 4 lines for expansion of the Direct Line Network. The link communicates with the Line Cards in Direct Line mode via the "Uplink" socket, or in Dialler mode via the "Phone" socket. i.e. In the event of a Direct Line failure between the Network Master and the Concentrator Link, a Dialler backup can be provided. A Concentrator link provides 4 Direct Lines which can each support 10 more Concentrator Links or Direct Line Challenger panels. Hardware: The unit is supplied in a metal enclosure 520x260x82mm with space provided for a 6.5AH Sealed Lead Acid battery. Front and rear tamper switches are fitted to the enclosure. Power Supply: The unit is powered by the AC Plug pack supplied. The on-board power supply has provision connection of the battery. Alarm Inputs: Two alarm inputs are provided on the board for connection to the tamper switches and PIRs as required at the installation. A third alarm input is provided for a keyswitch input for arming and disarming of the alarms. DDS Uplink: An RS232 port is provided for connection to a Data Digital Service uplink which can be used in place of the normal "Uplink" or "Phone" socket. Comms: An RS485 Comms port is provided for local connection to Network Concentrator sub-links, avoiding the need for a line connection. March 1995 Page 3

TECOM SYSTEMS NETWORK MASTER MINIMUM SYSTEM FEATURES The Network Master has the minimum features of: Max 100 Max 100 Direct Line Panels (10 units per Line card, expandable to 4000 panels with Network Concentrator Links. See System diagrams) Network Concentrator Links (10 units per Line card, expandable with Network Concentrator sub-links. See System diagrams) Max 10 Dialler Receiver Exchange Line Inputs Note: Total of 10 Line cards maximum per system. EQUIPMENT LIST TS2000 TS2010 TS2020 TS2030 TS2050 TS0073 Tecom Network Master Rack Network Master CPU Card Network Master Line Card Network Concentrator (4 Line) Parallel Interface - Tecom Direct Line 2A Power Supply and Battery Box Features and specifications subject to change without notice March 1995 Page 4

NETWORK MASTER SYSTEM BLOCK DIAGRAM TECOM NETWORK MASTER PRINTER VDU TERMINAL HOST COMPUTER CARD DIRECT MODE. CARD DIALLER MODE. OTHER CARDS MAX. 12 PER UNIT. CPU CARD DIALLER EXCHANGE Formats: Tecom dial-up Ademco High Speed formats Ademco 4+2 Checksummed Ademco Contact Point ID Checksummed LINK. 4 S CHALLENGER PANEL Direct Line Uplink Dialler Exchange Line Uplink LINK. 4 S Direct Line Uplink TECOM DIRECT PARALLEL INTERFACE Dialler Exchange Line Uplink CHALLENGER PANEL OTHER PANELS & INTERFACES. MAX. 10 UNITS PER. OTHER LINKS & PANELS. MAX. 10 UNITS PER. March 1995 Page 5

NETWORK LINK BLOCK DIAGRAM 16VAC PLUG PACK AC BATT AUX PWR O/P Network Concentrator Link 6.5 AH BATT. AUX RELAY LOCK ALARM INPUTS LOCK KEY INPUT DDS UPLINK Direct Line Uplink to Network Master via Data digital service. COMMS OTHER LINKS. UP TO 9 UNITS. D/LNK D/LNK D/LNK D/LNK U/LINK PHONE 4 3 2 1 Dialler Exchange Line Uplink to Network Master. FOUR DOWNLINK S TO CHALLENGER PANELS AND/OR LINKS. Direct Line Uplink to Network Master. CHALLENGER PANEL TECOM DIRECT PARALLEL INTERFACE OTHER PANELS & INTERFACES. MAX. 10 UNITS PER. March 1995 Page 6