User Manual. Single Diaphragm Dosing Pump SP-177. We set standards. Industriestrasse 56 FAX: FL-9491 Ruggell

Similar documents
PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

Rycroft Supapac Plate Heat Exchangers

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Oil burners fuel unit with solenoid valve

Dosing system. Commissioning and maintenance manual eco-pen300

Code (300ml)

Vacuum Pump V-100 Technical data sheet

Oil burners fuel unit with solenoid valve

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

OLF-5-TAK Tank connection kit 2.0

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

UV - flame detector dual fuel burners for intermittent burner operations

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Karlsruher Glastechnisches Werk KGW-ISOTHERM

Installation instructions Air drying unit for Bubble Sensor OTT CBS. English

AUC Cell Washer. User Manual

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

CP-200 Push Button. CP Warewash Pump Instruction & Operation Manual Push Button , Rev1.0,

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

The Safest Connections...

Operating Instructions. PowerFill. Automatic Granulate Conveyor for perfectmelt SE

PLATE HEAT EXCHANGERS. Operation and Maintenance Manual

3.5 GALLON PARTS WASHER

SOLENOID VALVES FOR REFRIGERATING SYSTEMS

Models Series Series

INCREASE YOUR LAB EFFICIENCY

Models Series Series

Symphony Plus Pressurized Water Sanitizing Kit P/N

SKJ. Specifications. Stroke Range Options 250 inches (6.4 m), 400 inches (10.2 m)

86BSD Digital Output

DURANGO 12V Heater HF

GASS Module. User Manual. Gas Analysis Sampling System PERMA PURE

transport handle gas ballast valve robust design for long life easy to clean integrated oil level window quiet running, minimized vibrations

Roofing Adhesive SARNACOL 2172 Spray

GLUE PUMPS. for Labelling Machines NEW MODEL ADVANTAGES: hoseproof IP66 programmable NFC-enabled

CalMag Filter Installation Instructions

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Vacuum Pumps and Accessories

Air Eliminator

Dissolved Oxygen Sensors

CP-200 S&T. CP Warewash Pump Instruction & Operation Manual Speed & Time , Rev1.0, , Page 1 of 8

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

ASPIRE Laboratory Aspirator

High Output Vacuum/Pressure Pump

AD SP. Air Dryer Maintenance Manual. Innovation with Integrity. Version 001 NMR

Operation and Maintenance Manual Sondex All-Welded Heat Exchangers (SAW)

Operation Manual. Equipment. Operation Manual. Loctite EQ PU20 Digital Peristaltic Dispenser. Part Number:

Please do not hesitate to contact us with any enquiries.

VRA2000 Series Port size: Rc1/4, Rc3/8, G1/4, G3/4, 1/4NPT, 3/8NPT

Adsorption dryers PDAD

AUTOMATIC FILM APPLICATOR MICROPROCESSOR CONTROLLED. Operating Instructions for the

NEOTeCHA Reactor Sampling Type PV

Product overview Suction Guns, suction machines, Vac-Blast Cleaners

PINNACLE WAREWASH CONTROL By DEMA DP-812-DL-1T DP-813-DLL-1T DP-812-LL-1T DP-813-LLL-1T Introduction

Air. Pressure. Motion. nnnnnnnn

The best solution for the control and the transfer of liquids and fluids Larius Industrial Technology Solutions

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Here is your conveying solution: Product group D.

Technology for Vacuum Systems. Instructions for use

Reliability in Laboratory Centrifuges Since Operator s Manual. Models 614B, 614L, 614U/UL and 614V/VL Laboratory Centrifuge. Rev. 5.

OWNER S MANUAL (English)

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Chemical resistant Vacuum Pumps

SMK 22 SMK SMK SMK 22-82

Adsorption dryer PDAD. (en) Operating instructions g [ ]

MVG. Modular Vacuum Grippers. US5

KRAL Screw Pumps. L Series.

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Condensate drains WA/PWEA

ECOPlus SERIES OF HIGH-PRESSURE METERING MACHINES

Retro Fit Rinse Pump Rev B

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar absolute) Press (bar g) (kg)

The Experts in Vacuum Solutions

Cooker Hood User Manual

Snifter ATEX22 VERSION. User Manual. Distributor

89BSD Digital Output

Product Specification RobExtractSpray 2400/4400

Operation Manual. Mobile Dustfree Pressure Air Blasting System HSP-20

Vacuum generators VADM/VADMI

MAKE CLEANING SAFER NEW TECHNOMELT. Your Machine Cleaning Guide & Hotmelt Cleaner Range

Vacuum Saving Valve. ZP2V Series. With One-touch fitting type available!

Air Filter. Filter for Removing Dust and Drain in Compressed Air. Filter for Drain and Dust (Filtering Accuracy: 5µm)

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

External and internal circulation with powerful pumping capability

Reducing Valve Direct Mount Type with Pressure Gauge. Direct Mount Type (Compact size) Pressure Gauge is selectable.

86BSD Digital Output

TECHNICAL CATALOGUE SILO VENTING DUST COLLECTORS. Manual No. FIL T.EN Issue: A Latest Update: January 2017 ORIGINAL INSTRUCTIONS IN ENGLISH

92831 TEL: (714) FAX:

HEB Series. Thermoelectric Bath

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

Oilless Refrigerant Recovery System. OWNER S MANUAL (English) TO BE OPERATED BY QUALIFIED PERSONNEL ONLY

Vacuum generators VADM/VADMI

VACUUM HEATING AND DRYING OVENS Gentle and safe

COMPRESSOR SERVICE REPLACEMENT KIT P/N (WCC 500A, 115/60, AIR COOLED)

Operating Instructions and Spare Parts List. ZR Monocyclone. Issued 09/01. ZR Monocyclone 9

barwell Rubber Deflashing Machinery ...a lifetime of reliability and support

AD XT. Air Dryer Service Manual. Innovation with Integrity. Version 003 NMR

Transcription:

We set standards User Manual Single Diaphragm Dosing Pump SP-177 MA-SP-177 en SAWATEC AG Tel: +423 37717 90 Industriestrasse 56 FAX:+423 37717 91 Postfach 514 info@sawatec.com FL-9491 Ruggell www.sawatec.com

Title Single Diaphragm Dosing Pump User Manual Manual MA-SP-177 en History v3.0: Cleaning procedure added v2.0: New page layout, no technical changes (2009-11) v1.0: First issue of manual (1999-06) Date of print 2010-07-06 Products Single Diaphragm Dosing Pump Copyright Disclaimer Trademarks 1999-2010 SAWATEC AG, FL-9491 Ruggell This manual contains proprietary information. All rights are reserved. No part of this document may be reproduced in any form or by any means for any purpose without prior consent in writing from SAWATEC AG, FL-9491 Ruggell. Whilst every endeavour was made to provide accurate and correct information, SAWATEC AG, FL-9491 Ruggell will not be liable for any damages whatsoever arising out of the use or the inability to use this product even if SAWATEC AG, FL-9491 Ruggell has been advised of the possibility of such damages. Trademarks appearing in this document are acknowledged as the trademarks of their respective owners. Audience This description of the Single Diaphragm Dosing Pump is intended for end-users. Manufacturer SAWATEC AG Industriestrasse 56 FL-9491 Ruggell Phone: +423 377 17 90 Fax: +423 377 17 91 E-mail: info@sawatec.com Web www.sawatec.com Customer service information Write down the contact details (phone, fax, etc.) for your System integrator or local distributor www.sawatec.com 2 MA-SP-177 en v3.0 2010-07-06

Application Features Orientation of the pump Safety issues The Single Diaphragm Dosing Pump is designed for Edge cleaning with solvents for CD-R, CDR-DVD-R and DVD-RW production. Application of protective coating for CD and DVD. Bonding DVD Application of photo resist coating for semiconductor production. To serve the application the pump has the following features: The pump handles a wide range of media viscosity. Very compact assembly saving space. Pressure-time controlled dispensing. Suck back valve at the outlet. All parts in contact with the medium are made of highly resistant materials. The pump can easily be disconnected for cleaning. The outlet of the pump must be on top. The pump must not be set up upside-down. Caution Injuries by medium splashing into your face When the pump is opened or tubing removed the fluid may still be under pressure. Always wear protective goggles when removing tubing from the pump or opening it for cleaning. Injuries from pumped mediums and solvents Pumped mediums used for cleaning the pump may harm the skin. Always wear protective gloves when opening and / or cleaning the pump. www.sawatec.com 3 MA-SP-177 en v3.0 2010-07-06

Technical data Media and pump properties Materials in contact with the medium Physical properties and environment General note on viscosity Property Nominal value Tolerance / Specification Dosing amount 0.1 12 ml ±0.1 ml depending o the timer setting Viscosity 10 800 cps Temperature +4 +60 C Maximum flow of medium 12 ml/sec depending on tube length and viscosity Part Material Pump membrane PTFE-IIR compound Bucar O-rings for tightening EPDM Optional: FFPM Metal parts Stainless steel SU 316 (ISO 1.4435) Pneumatic part Aluminum anodized Property Nominal value Specification Length / width / height 120 / 60 / 120mm Weight 3.8 kg Ambient temperature for drive +4 +60 C Compressed air and vacuum for pump functions Average lifetime 0.5 4.5bar -0.4-0.8 bar 30 10 6 pumping cycles regulated regulated Viscosity is resistance to flow. Viscous samples require special consideration. There are several separate issues, and these apply whether one desires to measure interfacial tension or contact angles. Viscosity is measured in milli Pascal seconds (mpa s) which is numerical identical to centi Poise (cp). Water has a nominal viscosity of 1cp or 1mPa s. Viscosity is a strong function of temperature, dropping rapidly as temperature rises. A good source of reference values for viscosity is the CRC Handbook of Chemistry and Physics (www.crcpress.com). Standards The Single Diaphragm Dosing Pump uses only DIN-CE certified elements. All elements specifically machined for the product are made of DIN-CE certified materials. www.sawatec.com 4 MA-SP-177 en v3.0 2010-07-06

Dimensions and connectors Optional arrangement of suck-back valve 1 2 C B Ø 120 M6, 6mm deep A 60 A (B) 17 60 C A Intake of the medium R 3 / 8 B Outlet of the medium R 1 / 4. C Air/vacuum for pump control, R 1 / 8. Optional arrangement of suck-back valve 1 Suck-back valve directly mounted on the pump. 2 Tubing exits the fitting at the pump and connects to the suckback valve, which is located about 10cm before the effective outlet. Orientation of the pump Intake (A) must always be at the bottom, outlet (B) must always be on top. www.sawatec.com 5 MA-SP-177 en v3.0 2010-07-06

Controlling the pump Vacuum -0.4-0.8 bar Regulator Compressed air 0.5 4.5 bar Regulator Throttle valve 3/2-way solenoid valve 24 V DC Liquid out Check valve Out (top) Membrane drive Timer In (bottom) Timer resolution Control diagram To be able to control the delivery according to the capabilities of the pump, the timer must have a resulation of 0.01 seconds (10 ms). Pressure 1 bar Pump vented Vacuum -0.4-0.8 bar 1.5 sec 3 sec dosing suction Suction time must be larger than dosing time. The values displayed are just examples. www.sawatec.com 6 MA-SP-177 en v3.0 2010-07-06

Cleaning Rinsing Rinsing of the pump is required in the following cases: The laquer (or other medium) to be pumped is changed. The pump will not be used for a shorter time. Rinsing the pump 1 Disconnect the pump from the ordinary supply. 2 Provide sufficient amount of solvent at the intake. The type of solvent depends on the pumped medium. 3 Purge the pump with large volume and large intervalls. Note: The solvent can be left in the pump, if it is unused for longer time. However, the solvent must be removed with the first cycles of again usage. Cleaning and drying The pump must be disassembled, cleaned an dried in the following cases: The pump is not used for a longer time. The pump shall be stored away. Cleaning 1 Disassemble the pump according to the diagram. 2 Wash alll parts with appropriate solvent. The type of solvent depends on the pumped medium. 3 Dry the parts with compressed air. 4 Assemble the pump again. C A Outer diameter: 4 screws M5 to open the housing of the pu B Inner diameter: 4 screws M4 holding t diaphragm ring (C). SP-177 B A www.sawatec.com 7 MA-SP-177 en v3.0 2010-07-06

www.sawatec.com 8 MA-SP-177 en v3.0 2010-07-06