Wireless thermostat SI-3 Installation and user guide

Similar documents
Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

EB-Therm 300 E / SSTL MONTERINGSANVISNING / INSTALLATION INSTRUCTIONS LEGGEANVISNING / ASSENNUSOHJEET

C-Stat 17-ZW User Instructions

KYROS INSTRUCTIONS MANUAL MOUNTING, INSTALLATION, STARTING AND OPERATION TOWEL RAIL

GB-DAS. Installation and user manual DEVIreg 850 controller

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

DOL 31 Speed Controller Technical User Guide

User Manual THR842DUK Wireless Digital Thermostat

CS027 User Instructions

Installation and operation manual

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

MC 31 Speed Controller Technical User Guide Code no GB

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Floor sensor (NTC) Temp (C o ) Value (kohm) 10 o C 19,9 kohm 15 o C 15,7 kohm 20 o C 12,5 kohm 25 o C 10,0 kohm 30 o C 8,0 kohm

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

SMART THERMOSTAT WITH HOT WATER CONTROL

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

GEYSERWISE INSTRUCTION MANUAL

Portable Refrigerator

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Installation Instructions

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

SEMTIC HEATING

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

status AW1 WiFi Alarm System Printed in China PA : AW1-UM-EN-V1.0 User Manual 2016 Chuango. All Rights Reserved.

Instruction FH-CWP Thermostat

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Sensor Control Panel

Settings and Maintenance of the CombinAir

ROBERTS. FM / MW dual alarm clock radio with instant time set. Please read this manual before use

1 For All Programmable Digital Thermostat. Meets Residential California Title 24

MENU. Steamist Digital Sauna Control Models: S170-1 and S Steamist Digital Sauna Control. Contents. 1. Steamist Digital Sauna Control

USER MANUAL Comfort System4 TM

GSM RFID VOICE Alarm System

System. For a better understanding of this product, please read this user manual thoroughly before using it.

1 For All Programmable or Non-Programmable. Digital Thermostat. Meets Residential California Title 24

AUS. Devireg TM 535 Installation and user manual

System Installation. multi-zone heating

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

Fire / CO Alarm Interface

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

Climapro 2. Installation. wireless room thermostat without receiver.

Manual & Technical Documentation V1.1

Table 1. Serie of Digital Room Thermostats.

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

MENU. Steamist Xenio Sauna Control, Product: 0941 and 0942 Model: S170-1 and S Steamist Xenio Sauna Control. Contents

Easy-Stat. Wireless Programmable Room Thermostat Pt No

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

RF Programmable Room Thermostat User Instructions

Clock Radio AJ100. User manual

Instruction Manual Contact Sensor

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Тел: Моб: Skype: Discoverytelecom Mail: EWK2 EWK2A WIRELESS KEYFOB

2018 thesimple, Inc.

7-Day. Digital Thermostat. residential. & 2-cool

Installation and operating instructions. Temperature difference controller 6 inputs, 3 outputs, integrated data logger for SD card

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

DELTA Ultimate technology

Alarm System SECURE AS 302

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

Schluter -DITRA-HEAT-E-WiFi Thermostat - Troubleshooting Guide External Use and for Inclusion in User Manual and/or Website

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

Varenummer: Version:

Mira Platinum Wireless Controller

GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

Mira Platinum Wireless Controller

AC500T, AC1000T, AC1500T, AC2000T

Operating Manual PU-27 Control Panel

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Battery Powered Electronic Programmable Room Thermostat

MONOBLOCK NG SERIES GAS BURNERS INSTALLATION, OPERATING AND MAINTENANCE MANUAL

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

USER S MANUAL HOME ENERGY SAVINGS REMOTE CAMERA INTERNET USER INTERFACE TEMPERATURE ALARMS BURGLARY PROTECTION DOOR SECURITY FIRE SAFETY

MODEL TSTATBBPB101 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Dolphin Bio Suction. Dolphin Bio Suction. User Manual Instructions.

Carrier NON-PROGRAMMABLE DIGITAL THERMOSTAT. Dual Setpoint Thermoglow Backlight No Batteries Required Auto Changeover Locking Keypad

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Model: Touch-RS. 1 Touch-RS

Thermostat Installation Best Practices

INITIALIZATION / INSTALLATION

User Manual THR872CUK Wireless Programmable Thermostat

EW 40 Wireless Fan Control

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Transcription:

Wireless thermostat SI-3 Installation and user guide SI-3 is delivered as single pole 16A version and dual pole 10A version. This manual applies to both versions. The connections are the same. Technical specifications Manufacturer: Sikom AS, Norway Type/Model: Wireless thermostat SI-3 300-8063V10/300-8064V10 Compatible with: Comfort and ECO system Operating voltage: 230VAC Max load: Single pole version 16A. Dual pole version 10A. Regulation: P-Regulator. 0-100% Measurement range: 0 C to +45 C ±2 C Regulation range: 5 C to +40 C Operating temp.: 0 C to +45 C Color: White (polar white, similar to RAL 9010) Radio Frequency: 433.9 MHz Sealing: IP20 Complies with the European R&TTE directive. Designed for indoor use only. Package contents Wireless thermostat Front cover and frame. Temperature sensor with 3m cable. Called sensor in the following. Do not expose the sensor cable to the sun or UV lighting. NB: This thermostat does not offer galvanic separation between high and low voltages. The sensor must therefore be regarded as a high voltage cable.

Installation Sensor: The standard sensor on the thermostat is a floor sensor from Sikom. A room sensor and/or floor sensor can be used. The room sensor is integrated in the thermostat. To activate this sensor, see the programming instructions. The wire from thermostat to sensor should be as short as possible. Room sensor: If the room sensor is used, the temperature will be measured at the thermostat. Do not place the thermostat in direct sunlight or close to other heat sources. Do not place it on an external wall or in zones exposed to draughts from windows or doors. Floor sensor: If the sensor is to be placed under the floor, it must be right in the middle of two heating cable segments, and as close to the surface as possible. The sensor wire should not be laid out near high current cables. The sensor should be placed inside a pipe that is grounded or covered with a grounded net. The pipe should also be closed at the sensor extremity. The installation shall be equipped with an earth leakage circuit breaker. All standard installation regulations must be followed. Installation: Connect 230V wires and floor sensor (if required) as shown in the figure below. Place the plastic frame on top of the thermostat (bottom part) before connecting the gray 10-lead cable to the front cover. Snap the front cover in place in the frame. L N Load 230VAC N L LOUT%%%LIN%%%NOUT%NIN%%%G Floor sensor Thermostat SI-3 (Front view of bottom part)

Registration with the central unit Registration ECO system: On the central unit, select the Setup screen, then Register new device (follow these icons): Activate the registration procedure on the thermostat by menu P7 Registration OK and a number will now be shown in the display of the central unit. Take note of this number for the end user; this number will be used for remote control of the thermostat. Registration Comfort system: Select menu 8 on the central unit. Select submenu 1 and press OK. Activate the registration procedure on the thermostat by menu P7 Registration OK and a number will now be shown in the display of the central unit. Take note of this number for the end user; this number will be used for remote control of the thermostat. 20 P! SIKOM AS SI-2 Display and LEDs Element on/off: Lights when the heating element receives current. Comfort: Comfort mode active. Eco: Eco mode active. On/Off switch: On mode or standby mode. Programming: P Programming switch.

Possible errors E0: Floor sensor faulty. E1: Faulty radio. No communication with the central unit. E2: Overheating inside the thermostat. Check the load. E3: Faulty overheating measurement. Contact dealer. E4: Faulty room sensor. Contact dealer. Errors will be shown in the display if there is something wrong with the functionality. If the thermostat is overheated, it will turn off the output relay until the temperature inside the unit is normal again. If there is something wrong with the sensor, the thermostat will shut down. An error will be shown in the display. Operation The thermostat can be configured and operated either remotely (e.g. by SMS messaging) or locally from the central unit, or finally directly via the thermostat buttons. Please refer to the manual of the central unit for further information. The thermostat will automatically dim the display after a while. Before the thermostat can be operated manually you must press any button to reactivate the display. Switching between eco and comfort modes: Press the up button to set comfort mode -> Green led will light. Press the down button to set eco mode -> Red led will light. Adjusting the target temperature: First, follow the above instructions to set the thermostat into the mode (eco or comfort) to be adjusted. Press the «P» button. Dots will start blinking in the display, and the set temperature will be shown for that mode. Use the up and down buttons to adjust the target temperature. Press the «P» button to store the temperature setting. Advanced operation: The thermostat has an advanced menu for registration and settings. This menu is activated as follows: Turn off the thermostat by using the power button. Press the «on/off» switch simultaneously with the «up» switch and release both after 5 seconds. The thermostat will display «P1» Menu Explanation MIN MAX Standard P1: Floor sensor type. 1 6 6 P2: Max temp in floor. 25 30 27 P3: Temperature compensation. -5 5 0 P4: Dimming. 0 45 30 P5: Thermostat type. 1 3 1 P6: Cycle time. 10 50 10 P7: Registration. To navigate between the menus, press the «P» button repeatedly. «P1 to P7» will be shown on the display. When you have reached the desired menu, wait until the setting for that menu is displayed. Adjust the setting with the up and down buttons. When settings are adjusted, press the «on/off» button to exit the advanced menu.

P1: Floor sensor type: 6 temperature sensors are supported. Choose the correct one according to the sensor type used. The default value is the Sikom sensor. Note: If room sensor is chosen in P5, this menu has no effect. 1. Microsafe 2. Microtemp 3. Devi 4. Elko 5. Ebeco 6. Sikom P2: Max temp in floor: If the maximum temperature in floor function is activated, the temperature limit can be adjusted here. As soon as the floor sensor measures this temperature, the heat element will be turned off even though the room sensor measures lower temperature. P3: Adjusting temperature compensation: The thermostat can be compensated if the displayed temperature is too high/low. The need for compensation is more frequent when the sensor is located under the floor. The compensation can be from -5ºC to +5ºC. This means that if the sensor measures 30ºC degrees and the compensation is set to -5ºC degrees, this will be reflected by the display, which will then show 25ºC degrees instead of 30ºC. P4: Adjusting dimming value: After a couple of minutes, the lights on the thermostat will dim. The dimming can be adjusted by this menu. The range is 0-45, where 0 is the weakest brightness. P5: Thermostat type: The thermostat can operate in 3 different ways: 1. Floor sensor. The thermostat measures temperature by the floor sensor. 2. Room sensor. The thermostat measures temperature by built in room sensor. 3. Maxtemp. The thermostat measures temperature by the room sensor, but limits the actual temperature in the floor by limit set in «P2». This temperature is measured by the floor sensor. P6: Cycle time: The heating element will be turned on and off 0-100% with a cycle time which can be adjusted in this menu. The interval can be from 10 to 50 minutes. The heating element will be switched on/off about once in this time interval based on the regulation calculation. P7: Registration: Use this menu to register the thermostat with the central unit. Activate the registration procedure on the central, and press «up» button when «--» is shown in the display. Wait until the registration completes successfully.

Compliance with international regulations This equipment complies with the European R&TTE directive. Further information may be obtained by contacting either www.ecostarter.com or the manufacturer: Sikom AS (www.sikom.no) WARRANTY Sikom A.S. products are covered by a two years warranty against any faults due to material flaws or manufacturing errors, which limit or render useless certain functions described for the product. The warranty requires the customer to present the original bill, with date of purchase and type of equipment clearly readable. What is covered by the warranty? During the warranty period, Sikom A.S. reserves the right to repair the product or to replace defective parts with functionally equivalent parts. If, after several attempts, Sikom A.S. is unable to correct the problem, and the product does not work as described in the manual, Sikom may elect to refund the purchase price or to replace the product with a functionally equivalent one. All replaced parts and products become the property of Sikom A.S. What is not covered by the warranty? Indirect damage to life, health, property, revenue and environment caused by circuits and appliances connected to the units (install and use this product responsibly). Costs related to (re)installing, transporting and dismantling units; recycling may be governed by special rules (see the relevant chapter). Damages caused by use outside of the operating conditions specified in the manual. Malfunctions caused by transport damages. Any unauthorized repair, modification or disassembly. Use of non-original parts. External factors, such as lightning, power supply issues, mobile network issues, flood damage or fire. Units with modified, removed or unreadable serial number. Sikom assumes no responsibility for any errors that may appear in this manual. Information contained herein is subject to change without notice. RECYCLING INFORMATION The WEEE (Waste Electrical and Electronic Equipment) symbol indicates that this product must not be disposed of along with other household waste. It is the customer's responsibility to dispose of the product properly by taking it to a designated site for recycling. To locate a recycling/disposal site near you, contact your local city recycling program, your regular waste disposal service or the agent from whom you purchased this product. For Switzerland, this product includes in its purchase price a contribution (the advanced recycling fee) to the SWICO Recycling Warranty, which means that used equipment can be handed in free of charge for recycling. Collection sites are listed at www.swicorecycling.ch.