Operations Manual GMA 313 CO 2. Gas Monitor for one detection point

Similar documents
GMA4100-DP. Control Panel. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Transmitter for O 2 ZD21. Operation Manual

Operations Manual DS 220. Docking Station for Micro IV

Operations Manual TS400. Test Station for G450/G460 Gas Detector

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Stand Alone DYNAGARD SP Operation Manual

Key-Operated Switch GMA 41 / GMA 44 SW. Operation Manual

Micro III (Models G203, G203S, and G213) Operation Manual

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

G450. Multi-gas Detector. Field Operation Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

G460. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

GMA200-MW16. Operation Manual. Gas detection controller for wall mounting

Monitores Personales. Personal Monitor

G450. Multi-gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

GMA200-MT. Operation Manual. Gas detection controller for mounting rail assembly

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

MICRO III (G202 / G202s / G212) Single Gas Detector

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Buzzer Unit. TAN-5000 Series. Operating Manual

GMA 36 Pro. Operation Manual. Stand Alone Monitor

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

GMA 36 Pro. Operation Manual. Stand Alone Monitor

FUNCTIONAL SAFETY MANUAL

Instruction Manual. Electronic gas and smoke detector GRM

VMX DEMAND CONTROLLED VENTILATION FOR NON RESIDENTIAL BUILDINGS

RAM 50 Series Operation Manual

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

Controllers. Instruction Manual WARNING

KANE-ALERT-CO 2 Monitor with Temperature

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

Instruction Manual WARNING

SIMRAD GD10 IR GAS DETECTOR

GL-CO-RFG Channel Gas Leak Alarm System

10yr O2NE & Safe-Ox. User Manual

Micro IV Operation Manual

User Manual R1.0 CO2Meter, Inc. Personal CO2 Monitor SAN-10

GMA200-MW4. User Manual. Gas detection controller for wall mounting

Danfoss gas detection units

CO2 Gas Warning System Assembly and Operating Instructions

testo 316-EX gas leak detector Instruction manual

English US User s Manual

User s Manual. MkVII CO 2 Safety System

Products and performance

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

BX444-Mc Gas Detector

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Oil Burner Controls LMO24... LMO44...

GMA 104 Operation Manual

Pioneer-R16 Gas Monitor Operator s Manual

Flame Monitor for Multiple Burner Furnaces D-LE 603 D-UG 660

Safe T Net 210. Instruction Manual Part Number Mar2010

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

SIMRAD GD10PE IR GAS DETECTOR

SAFETY MANUAL. Multispectrum IR Flame Detector X3301

Dräger Flame 2500 Flame Detection

MR3CCUHV Temperature/Defrost Control

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

RS Pro Infrared Temperature Sensor

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

1 measurement signal input 4-20 ma for connection to an external gas sensor 5 freely programmable alarm switching points per measuring point

Installation, Operating and Maintenance Manual

SMART EVO 2 - User Manual ELECTRICAL PANEL FOR 2 MOTORS

Microtector II G460. Operation Manual. 1 to 7-Gas Detector

PräsenzLight PräsenzLight PräsenzLight A.. PräsenzLight A..

Oil Burner Controls LMO24... LMO44...

Microtector G333. Operation Manual. Worldwide Supplier of Gas Detection Solutions -1-

Multi-Gas-Controller MGC2

AUR300C. Advanced Ultraviolet Burner Controller

MK10 CO Safety System Connected to Central Unit

Snifter ATEX22 VERSION. User Manual. Distributor

PERSONAL COMBUSTIBLE GAS DETECTOR

Sintrol Snifter A1+ Manual. Version 1.2.2

Warranty Registration

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

Forced draught gas burner

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

Dräger Flame 2100 Flame Detection

Instruction Sheet. Press & Hold: Item, to view settings, to test. 24 V ±10% 50/60 Hz 3 VA 120 V (ac) 5 A 1/6 hp pilot 240 VA 20 to 260 V (ac) 2 VA

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Table of Contents. 1. Mounting Tips... 2

Danfoss gas detection units

CC28. Operation Manual. Transmitter for flammable gases and vapours

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

Advanced Ultraviolet Burner Controller

C Note! LGI16... Burner Controls. Building Technologies

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

Dixell Installing and Operating Instructions release 7.0

Power Supply Display Module PSDM. Installation and Operation Manual

GMA101. Operation Manual. Worldwide Supplier of Gas Detection Solutions

Model OEM-2 INSTRUCTIONS FOR USE

2-Channel Smoke Detector SD - 110

Transcription:

GMA 313 CO 2 Gas Monitor for one detection point Operations Manual 1194 Oak Valley Dr, Ste 20, Ann Arbor MI 48108 USA (800) 959-0329 (734) 769-0573 www.gfg-inc.com

GfG Products for Increased Safety Congratulations on your purchase of a high technology product from GfG you have made an excellent choice! Our detectors are characterized by reliability, safety, peak performance and economic efficiency. They comply with national and international directives. This manual will help you operate the detector quickly and safely. Please take note of these instructions before putting the device into operation! If you have any questions, please feel free to contact us. GfG Instrumentation, Inc. 1194 Oak Valley Drive, Ste 20 Ann Arbor, MI 48108 USA Phone: (800) 959-0329 or (734) 769-0573 Fax: (734) 769-1888 E-mail: info@gfg-inc.com Website: www.gfg-inc.com

Table of Contents Introduction 1 For Your Safety 1 Application and Purpose 1 Detection Principle - Infra-red 2 Operation Notes 3 Turning On 3 Function Test 3 Detection Mode 3 Display and Operation Elements 3 Alarm for Gas Hazards 4 Remote Reset 4 Quick Adjustment - Yellow LED 4 Fault - Red and Yellow LED s 4 Service 5 Checking and Adjusting Alarm Thresholds 5 Maintenance and Inspection 6 Mounting 6 Accessories 6 Notes for Technical Safety 7 Contact Protection 7 Technical Data 7 Connection Diagram GMA 313 8

Introduction For Your Safety Like any piece of complex equipment, the GMA 313 will do the job it is designed to do only if it is used and serviced in accordance with the manufacturer s instructions. CAUTION: For safety reasons, this equipment must be operated and serviced by qualified personnel only. Read and understand the instruction manual completely before operating or servicing this device. The warranties made by GfG with respect to the product are voided if the product is not used and serviced in accordance with the instructions in this manual. Please protect yourself and your employees by following them. The above does not alter statements regarding GfG s warranties and conditions of sale and delivery. Application and Purpose The GMA 313 is a compact gas monitor for continuous monitoring of ambient air against carbon dioxide (CO 2 ) hazards. Sensor and controller are integrated in one casing. Should the CO 2 concentration exceed a threshold, the GMA 313 gives an audible and visual warning. In addition to this, a relay is activated. 1

Detection principle - Infra-red The GMA 313 uses the infra-red detection principle (NDIR) for accurate and reliable measurement of carbon dioxide (CO 2 ). Infra-red light is lead through the sensor chamber. The gas from the ambient air enters the sensor chamber by means of diffusion. Carbon dioxide absorbs a part of the light in a narrow spectral region. The light remaining in this spectrum is measured by the detector. The difference between the light emitted and received is proportional to the gas concentration. Water vapor and other gases, which might be in the sensor chamber, do not affect the absorption of light in this spectral region. A special thermostat control eliminates temperature effects. IR - Source Diffusion inlet Sensor signal IR - Light Sensor chamber Optical filter 2

Operational Notes Turning ON Once you have connected the GMA 313 to 110 V main voltage, the detector is turned on. Allow 30 minutes warm-up time. During this time, the yellow LED F and the red LED A are lit. During the warm-up period the GMA 313 cannot detect an increased CO 2 concentration. Once the warm-up time is completed, the GMA 313 turns to the detection and warning mode automatically. Function test Press button T for a short self-test of the gas monitor. Operational and fault LED as well as the buzzer and the alarm relay are shortly activated and checked for their function. Detection mode After the warm-up time the yellow and the red LED ( F and A ) go out. The GMA 313 turns to the detection mode automatically. The green LED ON lights and indicates, that the GMA 313 now monitors the ambient air continuously for hazards caused by carbon dioxide (CO 2 ). Display and operation elements Sensor inlet Reset button Test button Acoustic alarm LED Alarm - red LED Fault - yellow LED ON - green 3

Alarm for gas hazards The GMA 313 provides two alarm thresholds: Alarm 1 (low alarm) and Alarm 2 (high alarm). These thresholds are set to standard values. Should the carbon dioxide (CO 2 ) concentration exceed a threshold, the GMA 313 gives a warning by means of the red alarm-led and the buzzer. In addition to this, a relay is activated. The difference between alarm 1 and alarm 2 is indicated by pulsed or permanent alarm signals. Alarm Threshold Signal Alarm Storing 1 1.5% Vol. CO2 Pulsed alarm Non-latchingl 2 3.0% Vol. CO2 Permanent alarm Latching Alarm 1 is non-latching and goes out automatically, when the gas concentration has fallen below the threshold, i.e. if there are less than 1.5% Vol. CO 2. Alarm 2 is latching. Once it is triggered, it remains stored, even if the gas concentration has fallen below the setpoint. Alarm 2 must be reset by pressing the reset button Q. The buzzer in the GMA 313 can be reset at any time by pressing the reset button Q. The alarm relay is activated according to alarm 1 and alarm 2. Remote Reset with GMA 313 EQ (optional) The GMA 313 EQ is a remote alarm and reset unit. For connection of the remote reset GMA 313 EQ the gas monitor must include the component External Reset. Quick adjustment - when the yellow LED is lit If the yellow LED is lit, press the button Q for approx. 10 seconds to re-adjust the GMA 313. In case the yellow LED should not go out during this time, call for GfG service. Fault - when the red and yellow LEDs are lit In case of a fault, the yellow LED F and the red LED A at the GMA 313 and the alarm lamp at the remote reset GMA 313 EQ will be lit. A fault message is indicated: During the warm-up period. If the yellow LED F does not go out after this period, the microprocessor or the memory module may be faulty. In case of overrange. If the IR source is faulty. In case of a fault, disconnect the GMA 313 from the main voltage for a few seconds. Then re-connect and allow another warm-up period of approx. 30 minutes. Should the unit still indicate a fault, call for GfG service. 4

Service Checking and adjusting the alarm thresholds For checking or adjusting the alarm thresholds, use the calibration adapter to supply a test gas concentration (1.5 Vol. or 3% Vol.) of carbon dioxide (CO 2 ) to the sensor. Adjustment is done by means of the buttons T and Q. Before you do any adjustment, make sure that the GMA 313 has been turned on for at least 4 hours and is operating in the detection mode without any fault indications. Adhere to the following procedure to adjust the alarm thresholds: 1. Fix the calibration adapter into the sensor inlet. 2. Press button Q and keep it pressed, then press button T and keep both buttons pressed for approx. 3 seconds. Now the GMA 313 turns to service mode. The yellow LED F blinks in short intervals. In this mode the alarm signal from the relay is blocked. The GMA 313 returns automatically to detection mode after approx. 30 minutes, even if you do not do any adjustment. 3. Use the calibration adapter to supply a carbon dioxide (CO 2 ) concentration of 3% Vol. for adjustment of alarm threshold 2. Make sure that the flow rate is approx. 0.6 l/minute. 4. Purge the sensor with the gas for at least 2 minutes. A permanent acoustic sound indicates that the sensor has adapted to the gas concentration. 5. Once the sensor has adapted to the gas concentration, press button Q to accept the supplied concentration for alarm 2. Should the GMA 313 note a calibration error, the yellow F will light for approx. 5 seconds. In this case you should repeat the calibration from point 3. If you do not want to accept the supplied gas concentration, press button T. 6. The yellow LED F blinks slowly, and you may - for a very accurate adjustment - set the alarm 1 threshold (points 7 to 9). Pressing button T again overrides the second adjustment, and the GMA 313 returns to detection mode. 7. For adjusting the alarm 1 threshold use the calibration adapter and supply a concentration of 1.5% Vol. carbon dioxide (CO 2 ) to the sensor. Make sure that the flow rate is approx. 0.6 l/minute. 8. Purge the sensor with the gas for approx. 2 minutes. A permanent acoustic sound indicates that the sensor has adapted to the gas concentration. 9. Once the sensor has adapted to the gas concentration, press button Q to accept the supplied concentration for alarm 1. Should the GMA 313 note a calibration error, the yellow F will light for approx. 5 seconds. In this case you should repeat the calibration from point 7. If you do not want to accept the supplied gas concentration, press button T. The GMA 313 returns to detection mode. 5

Maintenance and inspection Maintenance and inspection are measures, which maintain the nominal status of the gas monitor and include regular checks and adjustments of the alarm setpoints. In addition to this, the functions of the gas monitor must be checked. Both maintenance and inspection may be done by an expert. The maintenance interval should not exceed 1 year according to BGI 836. In case of repair make sure that only the manufacturer s genuine spare parts are being used. Mounting For deciding on the mounting position you have to know and to consider the ambient conditions, e.g. ventilation, exactly. Do not forget, furthermore, that carbon dioxide is heavier than air. Mount the GMA 313, therefore, approx. 12 inches from the floor. Make sure that the gases reach the sensor even in case of bad ventilation. The sensor inlet must be accessible and free from any obstacles after the installation. The GMA 313 is protected against water and dust (IP54). Additional safety against mechanical damage is provided by the impact protection (optional). The mounting lugs (optional) allow quick and easy wall mounting without having to open the top of the GMA 313. Accessories Part Number GMA 313 EQ External additl alarm/reset for complete sets 2313201-1 GMA 313 Calibration adapter with tubing 2313203-1 Mounting brackets for wall mounting 2313207-1 Protective housing includes installation material 2313206-1 6

Notes for technical safety Contact protection The main supply and relay contacts of the GMA 313 provide insulation distances of 3 mm, i.e. they are designed for 110V operational insulation. In case a contact is operated on a contact-critical potential, the contacts closest to it are also considered as contact-critical. According to contact protection the contacts are not considered to be separated safely. The insulation of the secondary circuit from the primary circuit and the relay contacts complies to the requirements for contact protection. Distances of 6.5 mm ensure a safe separation. The secondary circuit operates on extralow safety voltage. Technical Data Gas Monitor Type: Detection range: Alarm thresholds: Casing Dimensions: Protection class: Gas supply Climate conditions Operation: Storing: Power supply Operational voltage: Power consumption: Fuse: Outputs Relay output: Testing Type approval: Low voltage regulation: Electromagnetic compability: GMA 313 0.0... 5.0 Vol.-% CO2 1.5 and 3.0 Vol.- % CO2 Height: 100 mm, Width: 100 mm, Depth: 57 mm IP 54 Diffusion -5... +45 C, 0... 99 % r.h., 700... 1300 hpa -25... +55 C, 20... 80 % r.h. 110 V 5.0% Vol. 3.0% Vol. 13 W 230 V / 50-60 Hz max. 6.5 W at 230 V G-Fuse T Fuse 0.032.064 A according A to DIN41662 max. switch voltage 250 V AC 5 A 50/60 Hz According to TRSK 313 by TÜV Rheinland According to EN61010 High voltage category II and soiling degree 1 as per EN50270 Radio shielding and interference resistance type class 1 7

Connection Diagram GMA 313 One detection point, main connection by plug, connection of GMA 313 EQ optional. Cable of 0.5 to 1.5 mm 2, cable gland (PG11) may be adapted to cable diameter by means of a reducer. 8

GfG Instrumentation, Inc. 1194 Oak Valley Dr. Suite 20 Ann Arbor, MI 48108 USA US/Canada: (800) 959-0329 US/Canada Fax: (734) 769-1888 International: +1 734 769 0573 International Fax: +1 734 769 1888 Website: www.gfg-inc.com Worldwide Manufacturer of Gas Detection Solutions 2013 Rev 2 (06/06/13)