Memco Panachrome Universal Controller Installation Guide

Similar documents
End To End Optical Beam Smoke Detector. Additional Information

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

DCS2000 DEMENTIA CARE SYSTEM USER GUIDE. For Software Version 1.2 1

Memcom Emergency Telephone

SAFESMART Backup Controller SAFE-FSP. Installation & Operation Manual

LMA LINE MONITOR ALERT USER S MANUAL

GAS SUPRESSION CONTROL PANEL:

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Memcom + Emergency Telephone

WARNING FIRE DOOR CLOSING

Product Manual SZ1144

Digiplex LED Keypads User s Manual

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Long-Range Barrier Sensors

Product Manual SZ1145

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Application, Installation, Operation & Maintenance Manual

MTRA-FSP Level Control Relay. Installation & Operation Manual

Installation and application. Leakage detectors, CLS/FLS/FLS10/MiniCAS II

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

PTE0705 Electric Fence Monitor

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Digiplex LED Keypads. User s Manual

FIRERAY 5000 range USER GUIDE

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Reflective Optical Beam Smoke Detector User Guide

CommStat 4 Controller

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

CAUTIONS ON INSTALLATION

Motorised Infrared Optical Beam Smoke Detector. User Guide

Operation & Maintenance Manual

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

ELSEMA MD2010. Application Controls automatic doors or gates when a vehicle is present. Description

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

TRX MAINS CONNECTION DIAGRAM

I/O ZONE 560/583 AND OPERATION MANUAL

LS800S Intruder Alarm System. Engineering Manual

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

A Beginners Guide to Inner Range Systems

Motorised Infrared Optical Beam Smoke Detector. User Guide

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

General Purpose IO Technical Manual

Universal Sensor. Installation Guide. t: f: e: w: uk.tunstall.com Version: V2.97 (421V0R1.

MO144. Operators Guide. Universal Timer Module

D-TECT 2 IP. GJD230 IP Motion Detector

UPM I. Unit Protection Module. Installation and Operation Manual (2015/06)

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

External Wireless Sounder

English. Italiano. Português. Françias. Español

WM3000 WIRELESS MODULES

Installation instructions

"VIP 2" ADVANCED LUBRICATION CONTROLLER

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

Ethernet General Purpose

CPS-1 USER S MANUAL AIR INLET / CURTAIN CONTROL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

EXTINGUISHING AGENT RELEASE MODULE

Secure WANDERING INSTALLATION AND USAGE GUIDE

Installation, Operating and Maintenance Manual

SMARTWALK DEMENTIA WANDERING SYSTEM

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

LZR -I30. max. detection range of 30 ft x 30 ft LASER SCANNERS FOR INDUSTRIAL DOORS LZR-I Page 1 of 12

D-TECT 3 IP. GJD260 IP Motion Detector

Gasflag. Single Channel Control Panel Alarm Only Apparatus. Installation, operating and maintenance instructions, M07225.

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Intelligent Security & Fire Ltd

Control Panel User Guide

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

Interface Modules for SENTRI

Fire Control Panel FS4000

PAT E N T System 88. COMPLIES WITH Singapore Standard : SS CP10 : 2005 British Standard : BS EN54-2 : 1998 BS EN54-4 : 1998 REV.00

INSTALLATION AND MAINTENANCE INSTRUCTIONS 6500R AND 6500RS REFLECTIVE TYPE PROJECTED BEAM SMOKE DETECTOR

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

QA16 Addressable System

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

User manual and installation guide

Operating Instructions

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

CRITICAL REQUIREMENTS OF TODAY S ELEVATOR LIGHT SCREEN DOOR CONTROLS by Robert A. Warner, Tri-Tronics Co., Inc.

False Alarm Management

Pioneer-R16 Gas Monitor Operator s Manual

Smart Temp. ApolloP/n Installation Manual. Version 1.0

LZR -I100/ -I110. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Multi-Gas-Controller MGC2

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

C106 Coded Access Keypad

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

False Alarm Management

Ultrasonic Wall Switch Occupancy Sensor Single Circuit

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

CO2 Carbon Dioxide Sensor

v Model No: TIMER Multi-function Timer Module Please note: * eeee on the display indicates a non valid dip-switch setting.

Transcription:

Memco Panachrome Universal Controller Installation Guide Ref No. C850 856GB Version 3 The Panachrome 3D Controller C3850 is designed to operate with Panachrome 3D detectors, e.g. C3540, C3510. Check you have the correct items. Controller Installation Position the controller in a suitable place on the roof of the lift car, and fix using 4 off No.8 screws. + + Signals from lift required: + + Power supply - AC supply voltage between 85 to 240V AC. + + Alternatively, 18-25V DC. + + Relay 1 output - a changeover relay provides the signal to the lift controller to re-open the doors. North American nudging mode This special timeout mode is used where the detector (not the lift controller) controls the nudging operation. The second relay contacts are used to control the elevator door closing speed and any audible or visual warnings. To select this function set switch 5 number 1 to. VISUAL INDICATI There are 2 options available to initiate the visual indication of door movement: 1. Automatic (Factory-set default position) - As the doors move, the system detects the motion causing the LEDs to flash red on closure, or illuminate green on opening. No additional wiring to the lift controller is then required. Switching delays vary according to door movement speeds and if the visual delay is not practical, then the installer should consider the external signalling method [see b) below]. 2. Nudging (not applicable to North American nudging mode) - When the Panachrome is used in Automatic mode and the elevator controller provides a nudging facility, then the nudging control signal can be connected to the Panachrome CLOSING input. This will ensure that when the doors close under nudging control the Panachrome display remains RED, even if the detectors are triggered. The polarity of the nudging control signal can be changed by setting switch 6 number 3 (SW6/3). 3. External Signal - Signals are required from the door operator/lift controller to switch the LEDs to red or green. Voltages of between 12V and 230V AC/DC from the door open and door close contactors are connected to the input of the Panachrome controller. Refer to Table below for details. Note: The voltage on the inputs must never exceed 250V. Beware of voltage transients which may exceed this (e.g. from relay coils). If necessary, fit appropriate suppression or snubber device. For external signal activation, SW6/3&4 must be set according to whether the voltage will rise or fall when the signal from the controller is applied. If the voltage rises when the doors move, then set SW6/4 on (Opening) SW6/3 (Closing). If the voltage is normally present, and falls when the doors move, then set these switches. External signal activation provides the quickest response to indicate door movement. Patents Singapore 200506875 Turkey B66B 13/26, E05F 15/00 USA US7,771,080 B2 Europe EP1626924 Denmark DK/EP 1626924 Australia 0309310.1

Switch Settings 3D control is split between SW4 in tables 2 & 3 and SW5 in Table 1. SW5 3D Control Functions 7 Normal 3D Adaptive 3D 8 2D detector fitted (C2540/C2510) 3D detector fitted (C3540/3510) SW5 2nd Relay Functions 1 Function disabled Canadian timeout mode enabled 2 Function disabled 2nd relay operates on 3D trigger 3 Function disabled 2nd relay operates with main relay (RL1) 4 Function disabled 2nd relay operates on system fault 5 Function disabled 2nd relay operates on 2D trigger longer than timeout period 6 Function disabled 2nd relay operates as SW5/5 above plus timed out 2D beam SW6 Visible Display Functions 1 Visual display Visual display 2 Wired, external signal, LED activation Automatic visual LED activation 3 Closing, external signal FALLS Closing, external signal RISES 4 Opening, external signal FALLS Opening, external signal RISES 5 NORMAL display mode TEST/DEMO display mode 6 Unused 7 Unused 8 Unused Table 1: SW5 & SW6 Settings The label inside the lid has further details on positions and settings of the switches. Adaptive Software The Panachrome 3D controller can be configured to operate with special adaptive software. In certain environments, the amount of light scattered from surfaces (e.g. marble floors, mirrored walls or within the detectors), may cause false 3D triggers. The adaptive software option allows the system to automatically sense this background level and adjust the trigger threshold appropriately. This is done by setting SW5/7. In environments where the amount of scattered light is low, then superior 3D performance can be obtained by turning the adaptive software off. This is done by setting SW5/7. Janus recommends the following settings:- C3510 Adaptive control off SW5/7 SW5/7 C3540 from 2007 on Adaptive control off SW5/7 C3540 pre 2007 Adaptive control on SW5/7

3D INSTALLATI NOTES 3D Configuration Instructions Introduction The Panachrome detectors have an infra-red light curtain and an independent proximity detection system which provides landing door protection. The 3D proximity detection projects half the separation width of the lift doors into the landing. The controllers door operator relay will de-energise on either a 3D or light curtain trigger and so cause the doors to re-open. In all 3D operation modes the 3D proximity detection will continue to remain active while the lift doors close up to a separation of 8, at which stage the 3D proximity detection is switched off. The 3D operating modes and sensitvity are set up using SW4 & SW5/7+8. When installing a Panachrome 3D system, the following precautions must be observed for trouble-free operation:- + + The landing doors must not lead the car doors by more than the suggested permissible amount as shown in Fig 1 and Fig 2. Note: The maximum permissible landing door lead is further reduced if the detectors are set back from the leading edge of the car doors. + + Always mount the detectors as close to the door edge as possible. + + For opening exceeding 4, it is recommended that As Doors Close mode is used. + + The detectors must be set no more than 3/8 apart when the doors are fully closed. The detector must be aligned to within ± 5/16 of the detector centreline. LANDING DOOR Fig 1: 3D detector position DETECTOR CAR DOOR 4 Door spacing a (inches) 3 2 0 1 / 2 2 4 Landing door lead b (inches) Note: this graph is indicative only and relies on the accuracy of installation and the reflective properties of the landing doors and the lift entrance Fig 2: Maximum permissible landing door lead b versus door spacing distance a 3D OPERATING MODES (SW4) The 3D proximity detection system can be set up to operate in a number of ways as described below: 1) As doors close - Switches 1 & 2 both 3D proximity detection will be activated as the doors begin to close. The system will allow up to three consecutive triggers on the 3D. After this, the 3D will be turned off leaving only the light curtain detection. If the light curtain is broken then three further 3D triggers are enabled. *Note: If the 3D is triggered there is a 2 second delay before the 3D is re-enabled to allow the doors to reopen.

2) 3D Timeout (20 seconds) - Switch 1 and Switch 2 In this mode of operation the 3D proximity detection is activated when the doors have reached their fully opened position. As long as the 3D detection zone is clear the doors will be closed normally by the door operator. However, if someone is inside the 3D detection zone then the doors will be held open i.e. the door operator relay is deenergised and a timer is started. If the timer expires the doors are allowed to close with an intermittent beep sounding as a warning. This beep will occur regardless of the TE switch position. If the 3D zone becomes clear then the timer is reset and the door operator relay is re-energised allowing the doors to close. If the light curtain is broken at any time, the timer will then be reset and the door operator relay is deenergised which allows the doors to re-open. The 3D timer is set at 20 seconds internally. 3) At 2 8 - Switch 1 & Switch 2 This mode of 3D operation is similar to As Doors Close but the 3D will only become active when the doors are closing and have reached a separation of 2 8. This mode is usually for wider doors to restrict the range of 3D detection into the landing. Note: If the 3D is triggered there is a 2 second delay before the 3D is re-enabled to allow the doors to reopen. 4) 3D Timeout (10 seconds) - Switch 1 & 2 The operation is the same as in Section above. However, the 3D is set at 10 seconds internally. 3D CTROLLER SWITCH SETTINGS (SW4) 3D Operating Mode Switch 1 Switch 2 As Doors Close At 2 8 3D Timeout - 20 seconds 3D Timeout - 10 seconds Table 2-3D Operation Mode 3D Sensitivity Switch 3 Switch 4 Highest Intermediate Normal 3D detection off Table 3-3D Sensitivity 3D Sensitivity Adjustment: (SW4) In most cases the 3D s sensitivity will not require adjustment. However, it may need to be adjusted to overcome spurious reflections which cause erratic 3D triggering. The sensitivity should be first be set to the highest level i.e. level 1. If erratic 3D triggers are experienced then select the next lower level of sensitivity. Continue lowering the sensitivity until the unit operates without any erratic 3D triggers. Level 1 - Highest Sensitivity Level 2 - Intermediate Sensitivity Level 3 - Normal Sensitivity Level 4-3D Detection Off 3 4

Troubleshooting: No 3D detection when the 3D is supposed to be active Check that 3D detectors are fitted i.e. Model C3540 or Model C3510 Check that TX is on the left and RX on the right when viewed from the landing Check that switches SW4/3 & 4 are not in the position Check that switches SW4/1 & 2 are correctly set to the desired mode Unit false triggers as doors are closing Make sure that the 3D detectors are mounted as far forward as possible Reduce the sensitivity using switches 3 & 4 if necessary OPTIAL INPUTS DOC - Door Open Contactor DCC - Door Close Contactor Fig 3: Panachrome Installation Diagram FROM LIFT CTROLLER DOOR OPERATOR MAINS N/C L (Live) DCC DOC N/O COM N (Neutral) G (Ground/Earth) 2nd RELAY CTACTS L N G SW6 VISUAL LED DISPLAY SWITCHES J1 SW4 3D SWITCHES TE SWITCH SW5 3D 7 2ND RELAY SWITCHES TX OUTPUT RX OUTPUT J11 TEST SWITCH TIMEOUT SWITCH 415 Oser Avenue, Suite Q Hauppauge, NY 11788 Phone: 631 864-3699 800 527-9156 Website: www.januselevator.com E-mail: sales.us@avire-global.com PANACHROME TX PANACHROME RX PAC IG Janus V03 (GB)_PA/26.02.2015