N-8000 SERIES IP INTERCOM SYSTEM

Similar documents
VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

VX-2000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Solutions for Mass Notification Systems

Call stations and extensions

SECTION VIDEO SECURITY COMMUNICATION SYSTEM. Logo. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Microphones VIGIL VIGIL. Unitouch. combined data sheets LEADING THE WAY TO SAFETY

Public Address Project Combisound System

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

X-618 Digital Public Address and Voice Alarm System. Cherian George Product Manager PAVA systems

For Dealers / Integrators / Architects. IS Series. Video Intercom. Building Communication. Controlling Security.

16 Zone Voice Evacuation VA & PA Sound System

SMART. FLEXIBLE. RELIABLE.

5120_School_Intercom_Rack_Spec.doc 10/10/07

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

Jacques Technologies Pty Ltd. IP Commercial Communication System

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

Bosch Plena Public Address and Voice Alarm System The fast route to safety

_5120_School_Intercom_Rack_Spec.doc 09/21/04

Pre-Installation Requirements:

Comprehensive Solutions for School Communication Amplified Learning Public Address Emergency Notification Intercom Bell Schedule Clock

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

Total Unified Solution for Building Integration: Communications, Access Control, Video Surveillance and Fire

SMS GSM Alarm Messenger

IEC Electroacoustic EMERGENCY WARNING SYSTEM. for a maximum of system security 79

AVCOM System Installation Instructions

Networked Public Address and Voice Evacuation

School Paging. IP/SIP Intercom and Paging. Prepared by: John Vellone

EN ASTRO-PA/GA System. ASTRO-PAGA Digital IP Public Address & General Alarm SYSTEM for INDUSTRIAL SAFETY APPLICATIONS

Get all messages across, no matter what.

Greater flexibility, covering more applications.

DESCRIPTION INSTALLATION

OPERATING INSTRUCTIONS VOICE EVACUATION SYSTEM FS-7000 SERIES

VACIE REFERENCE GUIDE REVISION 1.2.6

Vocia VACIE. Reference Guide

Security Alarm Systems

Railways. Security & Operational Communications.

Networked Public Address and Voice Evacuation

GAI-Tronics Corporation. Serverless Page Party (SP2) Publication : SP2 Intelligent Intra-Plant Communication and Emergency Notification System

SIP Alerter. Each SIP Alerter also has an onboard relay, enabling centralized control of a classroom door lock for emergency lockdown scenarios.

SOLUTIONS FOR SENIOR CARE FACILITIES BUSINESS COMMUNICATION SERVERS

intercall innovative care systems

TX3 Series TELEPHONE ACCESS SYSTEMS. Programming Manual

Voice Alarm system integration

We supply sound, not equipment.

Alarm Tone Generator Model AG17

DTS MOBATime's Distributed Time System

Your benefits using DTS 4148.grandmaster: Features two completely separated LAN ports: provides NTP in two different networks

PROJ. NO SECTION PAGING, SPEAKERS AND HARD-WIRED CLOCK SYSTEMS

The Windcrest Remote Alarm for Passenger and Goods Lifts with Optional BS EN81-28 & BS EN81-70

Intelligent Security & Fire Ltd

The Leaders in Security and Life Safety Communications

"VOICE OF SECURITY: Trends In Intercom, Public Address, and Mass Notification Emergency Communications

Surface Mount Wall Speaker with InformaCast

GPS or DCF 77. DTS Masterclock

IP-based Building Management Control

Entero Voice Alarm system.

Bosch DECT6000 On-site paging. And cordless telephony...

i.net Engineered system solutions for

POPE FRANCIS HIGH SCHOOL SPRINGFIELD, MA BID SPECIFICATION PUBLIC ADDRESS AND INTERCOM SYSTEM

PRODUCT GUIDE. Patient/Staff Communications Solutions. COMMUNICATING WITH THE WORLD

ECC-50/100C. Emergency Command Center

TrueAlarm Fire Alarm Systems

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TECHNOLOGY TECHNOLOGY

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

TrueAlarm Fire Alarm Controls

Interfacing with the ADAM Module

SP40S-D. Kingfisher Company, inc. Features: Description:

Contents. 30 References

Smart Home & Office Automation

Access Professional Edition. The flexible access control system that grows with your business.

NeXT is a powerful stand-alone application running fully embedded in network cameras to perform an intelligent video surveillance for ATM devices.

Digital Door Entry System. Specification

PA/VA solutions for transport industry

EasyAlarm ELEVATOR LEITRONIC AG

- Basic information of Laser Scan detector

Informer100 Speaker Models I-IP100AC and I-IP100DC

Simplify. Secure. Your Home. Your Life. M1 Security & Automation Controls

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

LightSweep. Lighting Control System

AUDIO- AND ALARMMANAGEMENT

JM Series. 7-inch Touchscreen Intercom

SI120 Guarto Easy I. Alarm system. Fire & Security Products

3226 Trunk Port FXO Doorphone

GE Security Sound and Communications. Product Guide. Telligence. Voice-over-IP Patient-Staff Communication System. imagination at work

CRESTRON MEDIAMANAGER INTELLICLASS

University. NewVoice. San Francisco Paris Geneva Zurich Linz Mainz Shanghai Brisbane Hong Kong São Paulo Dubai

Intelligent Line Module

AlertWave. visiplex. From a Public Address System to an Emergency Communication System... The AlertWave system advantages:

SCORPION Z16040C, Z8040C and Z5120C

Safer Smarter More Livable Buildings. TX3 Voice Entry & Access Control Solutions. [TX3] Series.

Elemec3. Networked Public Address and General Alarm System (PA/GA)

SAFETY AT SCHOOLS. We supply sound, not equipment. the integration of intercom and voice alarm systems makes schools safe.

E3 Series Broadband System

telecommunication systems

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Building Technologies

sirens speakers and programmable controls

S.No. Description Unit (approx.) Unit price Total amount

Transcription:

N-8000 SERIES IP INTERCOM SYSTEM IP Network-Compatible Intercom System with Packet Audio Technology developed with cutting-edge TOA technological strengths for greater versatility and improved sound quality

Ultra-reliable communication systems developed experience in emergency broadcast systems, Designed to offer no-compromise reliability, the N-8000 is an IP network-compatible intercom system using packet audio technology. Monitoring can be real-time on an internet browser as the system is not server-based. System frequency response extends to 7 khz, allowing even PA-delivered announcements to be extremely clear and easily intelligible. The unique TOA intercom system achieves a high reliability system that guarantees "fast, accurate and reliable" communications. A communication selection can be made by users as needed -- the "Master-to-Master" system optimized for duplex conversation at venues such as factories and hospitals, or the "Master-to-Sub" system which is particularly suited for schools, prisons and similar locations. As the N-8000 has been designed for system flexibility with an open architecture, interfacing with other systems as well as surveillance cameras, telephones, access controls, and so forth is easy. System functions are numerous ranging from conversation, paging broadcasts, BGM broadcasts, and various security functions including emergency paging/ broadcasting and audio triggering. Designed for maximum expandability from simple systems to large, complex large systems. A single N-8000 system can connect up to a maximum of 3,072 stations and can assign up to 192 zones for paging. The TOA N-8000 Series is an ideal solution for applications that require a conventional communication system that can accommodate emergency communication needs as well. Performance comparison with IP telephone-based systems The N-8000 delivers outstanding audio quality that maintains perfect clarity and intelligibility even when interfacing with PA equipment for delivery. Operational system costs can stay low since network maintenance cost is the only requirement. Calls can be made instantly, enhancing system use for frequent business communications. Stations can also be used under special circumstances such as the use of models not compatible with IP phones.

with TOA's accumulated expertise and eady for any requirement. System Overview Up to 3,072 stations up to 16 sub-stations per Exchange up to 16 sub-stations per Exchange N-8500MS N-8600MS N-8000MS N-8010MS RS-150 RS-144 RS-450 RS-160 RS-143 RS-460 N-8510MS N-8020MS N-8011MS RS-170 RS-142 RS-470 N-8540DS N-8640DS N-8050DS N-8031MS RS-180 RS-140 RS-480 IP station Exchange () Exchange (N-8000RS) Exchange (N-8400RS) Up to 192 components Network N-8000MI N-8000CO N-8000AL N-8000AF N-8000DI PBX Up to 6,144 contact inputs and outputs Analog Telephone

N-8000 System Advantage Server-less System Since the N-8000 Series is a server-less system, it is particularly cost-effective when constructing a small-scale system as a costly server is not needed. Another advantage in not being server-reliant is being free from total system failure when a server goes down, providing users with more reliable operation. VPN Router VPN Router Switching Hub Switching Hub Exchange IP Master Station Substation Interface Unit Door Station Master Station Substation Exchange-less System The N-8000 Series allows an exchange-less system to be set up. This is a significant advantage for configuring a small-scale system with a limited number of terminals. As long as bandwidth is secured, communications can be instantly established simply by connecting the N-8000 to an existing network. VPN Router VPN Router Switching Hub Switching Hub IP Master Station IP Master Station IP Door Station

Integration with PA and CCTV system PA System Multi-Interface Unit/ Audio Interface Unit Exchange Switching Hub Switching Hub VPN Router VPN Router Switching Hub Switching Hub Multi-Interface Unit/ Audio Interface Unit/ Direct Select Unit Multi-Interface Unit/ Audio Interface Unit/ Direct Select Unit Substation Interface Unit Fire Alarm System Access Control CCTV System

Features & Functions System Features System configuration by intuitive software through "Master-to-Master" or "Master-to-Sub" station communication Selectable two wiring system: 2-core shielded type or 4-wire type connection Integration with such other system as access control, voice alarm system, CCTV system Ambient noise control Time correction function Operation and stream logs System diagnosis Basic Communication Features Handset / Hands-free conversation Recall Redial Camp on busy Mic-Off Remote response Single digit dialing Call transfer Comprehensive call forwarding features Three-party conference Expandable system The cost-effective N-8000 system can easily be configured to any scale to match the user s specific requirements. Up to 192 exchanges, IP stations and assorted interfaces can be connected for a maximum of 3,072 stations. No boundary limits The N-8000 is an IP network-compatible system, allowing local areas to be linked to cities in other countries. Under centralized PC control using TOA software, all exchanges, IP stations and interface units can be connected to s, s and fiber optic networks. Integrating communications and safety The N-8000 integrates several systems under efficient central control -- from duplex conversations between stations, paging broadcasts, scheduled broadcasts, to background music broadcasts and similar functions. The N-8000 also provides master control, connecting to pre-existing intercom, alarm, surveillance, door entry/departure authorization and similar other systems. Long-term cost-effectiveness All calls between N-8000 system stations are free of charges to reduce basic telephone bills. N-8000 system architecture lowers long-term total ownership costs as the system is openended and system scale can be configured as required. Excellent audio advantages The N-8000 delivers high-quality audio for background music, paging and recording applications. Full logging options A full menu of operation and stream logging options include verifying operation, voice communications and line supervision logs, all easily archived for instant recall. Security both in and out of the system The N-8000 system minimizes downtime with a 24/7 internal surveillance function. A packet audio protocol guards against wiretapping. Simple installation and maintenance N-8000 installation is simple and requires very little site work as existing wiring can be used and components plugged in. TOA s dedicated software includes a maintenance application for system status, troubleshooting, logging as well as system updating and remote control applications.

Key Functions Supporting Multi-Communications Paging Function Allows the master station as well as external input equipment to initiate paging to PA equipment or the speakers of each station. Use the setup software to configure up to 192 paging zones to which paging calls can be made as desired. Master Station or less or less Remote Microphone External Equipment N-8000MI or N-8000AF N-8000RS Analog Telephone N-8000AL Telephone Mobile phone N-8000CO N-8000MI N-8000AF Telephone PBX N-8000MI BGM Distribution Enables music from any of eight BGM sources connected to the N-8000MI to be distributed through speakers at the master and door stations. BGM Source 1 BGM Source 2 N-8000MI BGM 1 BGM Source 8 BGM 3 Time Signal Function Enables the built-in chime of the N-8000AF or an externally connected audio source to be broadcast to stations and PA equipment according to a preset schedule. Schedule or less N-8000AF Built-in Chime N-8000RS N-8000MI N-8000AF N-8000DI Lamp

Direct Select This creates an operation panel equipped with indicator lamps and control buttons for the master station. This panel is compatible with other stations, assigning each channel of the contact input and output to the master station and substations for identifying which substation is calling the programmed master station. No. 101 N-8000DI No. 105 Calling CCTV Interface When a CCTV monitor-equipped station receives and answers a call, the site of the station making the call is displayed on the monitor. Camera Calling N-8000DI CCTV Switcher Camera Scan Monitor Allows the master station, as well as analog telephones and external telephones to audio monitor two or more preprogrammed stations, making remote security monitoring possible. or less N-8000AL Analog Telephone N-8000RS N-8000CO Telephone Mobile phone Door Remote Control Makes it possible for when the master station engaged in ongoing conversation with the N-8540DS or the N-8050DS Door Station to easily execute door lock control through a contact output. Door Control Master Station Instruction Door Station Privacy The RS-140 Switch Panel offers a Privacy Mode that refuses paging calls from connected speakers and can prevent scan monitoring except for emergency calls. X RS-140

Security and Safety Emergency All-Group Paging A function that suspends ongoing conversations, paging and other operations to allow emergency all-group paging to all stations, PA equipment and lines. Master Station or less or less N-8000RS Analog Telephone N-8000AL N-8000MI N-8000AF N-8000AL Analog Telephone Message Paging Initiates emergency paging with prerecorded emergency messages on the IP Master Stations. N-8000RS N-8000MI N-8000AF Emergency call Pushing the call button twice quickly commands the door station and substation to make an emergency call to master stations and analog telephones. N-8000RS N-8000AL Analog Telephone Recording Any conversation between master station/telephones and during a three-party conference, paging messages, and scan monitored audio can be recorded on recording equipment connected to the N-8000AF. Connection or less N-8000AF Recording Device or less Audio Trigger If an auto input to a pre-programmed door station s microphone fulfills preset conditions (detection time or signal level), the door station initiates an alarm. An example would be making a call to the designated master station or generating a contact output of any other interface units. Door Station N-8000MI Contact output Revolving light N-8000DI

Station Selection Chart Desk-top with bracket Wall-mount Applicable Exchange / Interface Master / Door Stations RS Sub-stations IP Stations 2-core shielded type station 4-wire type station N-8000MS N-8010MS N-8011MS N-8020MS N-8600MS N-8500MS N-8050DS N-8050SB N-8031MS N-8031SB RS-150 RS-140 RS-450 RS-144 RS-143 N-8640DS Vandal-resistant type RS-160 RS-170 RS-180 RS-460 RS-470 RS-480 Outdoor type N-8010EX N-8000RS N-8010RS N-8400RS N-8540DS N-8510MS

Products Lineup IP Network Intercom Exchange Sixteen-station capacity Stations connect to exchange via twisted pair cable Speech links: 4 internal/8 external Two audio paging outputs Two relay outputs 420 (W) 44.3 (H) 349 (D)mm (16.54" 1.74" 13.75") 4.2kg (9.26 lb) N-8010EX IP Network Intercom Exchange Sixteen-station capacity Stations connect to exchange via twisted pair cable Speech links: 1 internal/2 external 420 (W) 44.3 (H) 349 (D)mm (16.54" 1.74" 13.75") 4.2kg (9.26 lb) N-8000MI Multi Interface Unit Audio Inputs for BGM, External Tone or Paging Two audio line inputs (0 dbv) with two trigger inputs Two audio line outputs (0 dbv) with two relay outputs Contact Bridge Sixteen contact inputs Sixteen relay outputs Telephone Interface (E&M type), two channels Function to diagnose system line and network statuses 420 (W) 44.3 (H) 239.5 (D)mm (16.54" 1.74" 9.43") 2.8kg (6.17 lb) N-8000AF Audio Interface Unit One MIC/LINE audio line input One audio line output Eight contact inputs Eight contact outputs Time synchronization input Built-in timer and chime 210 (W) 44.3 (H) 267 (D)mm (8.27" 1.74" 10.51") 1.7kg (3.75 lb) N-8000AL Telephone Interface Unit Single telephone line allowing an analog telephone to be connected 210 (W) 44.3 (H) 267 (D)mm (8.27" 1.74" 10.51") 1.7kg (3.75 lb) N-8000DI Direct Select Unit 32 contact inputs 32 contact outputs Function to diagnose system line and network statuses 420 (W) 44.3 (H) 267 (D)mm (16.54" 1.74" 10.54") 2.8kg (6.17 lb)

N-8000CO C/O Interface Unit Analog central office line circuit allowing the stations to make and receive calls to and from the telephone line 210 (W) 44.3 (H) 267 (D)mm (8.27" 1.74" 10.51") 1.7kg (3.75 lb) N-8000RS Sub Station Interface Unit Up to 16 substations connectable using two-core shielded cable Speech links: 2 420 (W) 44.3 (H) 349 (D)mm (16.54" 1.74" 13.75") 4.2kg (9.26 lb) N-8010RS Sub Station Interface Unit Up to 16 substations connectable using two-core shielded cable Speech links: 1 420 (W) 44.3 (H) 325.5 (D)mm (16.54" 1.74" 12.81") 3.8kg (8.38 lb) N-8400RS Sub Station Interface Unit Up to 16 substations connectable using two pairs of twisted pair cables Speech links: 2 420 (W) 44.3 (H) 325.5 (D)mm (16.54" 1.74" 12.81") 4kg (8.82 lb) N-8600MS IP Multifunctional Master Station Handset or hands-free duplex communication Connects directly to network (10/100Base TX) Power-over-Ethernet compatible or optional power supply, model AD-1215P Two RJ-45 network connectors (one for network, one for PC) Alphanumeric LCD display (32 character) Eight user-programmable speed dial keys Headset terminal External speaker terminal (0.5 W / 8 ohms) Optional wall-mount bracket, model YC-280 148 (W) 208 (H) 70.5 (D)mm (5.83 8.19 2.78 ) (excluding a curly cord section) 710g (1.7 lb) N-8500MS IP Multifunctional Master Station Handset or hands-free duplex communication Connects directly to network (10/100Base TX) Power-over-Ethernet compatible or optional power supply, model AD-1215P Two RJ-45 network connectors (one for network, one for PC) Alphanumeric LCD display (32 character) Eight user-programmable speed dial keys Headset terminal External speaker terminal (0.6 W / 8 ohms) Optional wall-mount bracket, model YC-280 148 (W) 208 (H) 70.5 (D)mm (5.83 8.19 2.78 ) (excluding a curly cord section) 810g (1.79 lb)

N-8510MS IP Standard Master Station Handset or hands-free duplex communication Connects directly to network (10/100Base TX) Power-over-Ethernet compatible or optional power supply, model AD-1215P Two RJ-45 network connectors (one for network, one for PC) Contact input terminal Optional wall-mount bracket, model YC-280 148 (W) 208 (H) 70.5 (D)mm (5.83 8.19 2.78 ) (excluding a curly cord section) 740 g (1.63 lb) N-8640DS IP Door Station Hands-free duplex communication Connects directly to network (10/100Base TX) Power-over-Ethernet compatible or optional power supply, model AD-1215P Hands-free duplex communication Separate mic. and speaker Control output (open collector) IP65 rated Optional flush-mount back-box, model YC-150 Optional surface-mount back-box, model YS-13A 115 (W) 162 (H) 58.5 (D)mm (4.53" 6.38" 2.3") 780g (1.72 lb) N-8540DS IP Door Station Hands-free duplex communication Connects directly to network (10/100Base TX) Power-over-Ethernet compatible or optional power supply, model AD-1215P Hands-free duplex communication Separate mic. and speaker Control output (open collector) IP54 rated Optional flush-mount back-box, model YC-150 Optional surface-mount back-box, model YS-13A 115 (W) 162 (H) 55.1 (D)mm (4.53" 6.38" 2.17") 700g (1.54 lb) N-8000MS Multifunctional Master Station Handset or hands-free duplex communication Two-wire connection to or N-8010EX Exchange Alphanumeric LCD display (32 character) Eight user-programmable speed dial keys Headset terminal External speaker terminal (0.6 W / 8 ohms) Optional wall-mount bracket, model YC-280 148 (W) 208 (H) 70.5 (D)mm (5.83" 8.19" 2.78") (excluding a curly cord section) 737 g (1.62 lb) N-8010MS Standard Master Station Handset or hands-free duplex communication Two-wire connection to or N-8010EX Exchange Optional wall-mount bracket, model YC-280 148 (W) 208 (H) 70.5 (D)mm (5.83 8.19 2.78 ) (excluding a curly cord section) 700 g (1.54 lb)

N-8011MS Standard Hands-Free Master Station Hands-free duplex communication Two-wire connection to or N-8010EX Exchange Headset terminal External speaker terminal (0.6 W / 8 ohms) Optional wall-mount bracket, model YC-290 92 (W) 195 (H) 56.1 (D)mm (3.62" 7.68" 2.21") 400g (0.44 lb) N-8020MS Industrial-Use Master Station Heavy duty dustproof and waterproof construction (IP54 rating) Two-wire connection to or N-8010EX Exchange Handset or hands-free duplex communication External speaker terminal (0.6 W / 8 ohms) Control output Optional wall-mount bracket, model YC-280 170 (W) 220 (H) 97.8 (D)mm (6.69" 8.66" 3.85") (excluding a curly cord section) 1kg (2.20 lb) N-8050DS Door Station Two-wire connection to or N-8010EX Exchange Hands-free duplex communication Separate mic and speaker Control output (open collector) IP54 rated Optional flush-mount back-box, model YC-150 Optional surface-mount back-box, model YS-13A Also available as PCB assy., model N-8050SB 115 (W) 162 (H) 54 (D)mm (4.53" 6.38" 2.13") 680g (1.50 lb) RS-191 N-8031MS Flush-Mount Hands-Free Master Station Two-wire connection to or N-8010EX Exchange Hands-free duplex communication External dial inputs (7, 8, 9 and C keys) Optional Handset, model RS-191 Optional flush-mount back-box, model YC-241 Optional surface-mount back-box, model YC-251 Also available as PCB assy., model N-8031SB 115 (W) 254 (H) 54.6 (D)mm (4.53" 10.0" 2.15") 850g (1.87 lb) N-8031SB Hands-Free Master Station Board Unit N-8031SB PCB for custom station applications Speaker and microphone included External dial inputs (7, 8, 9 and C keys) plus switch matrix connection LED Status Indicator output Optional Handset, model RS-191 70 (W) 185 (H) 20.6 (D)mm (2.76" 7.28" 0.81") 205g (0.45 lb) (including accessories) N-8050SB Hands-Free Substation Board Unit N-8050DS PCB for custom station applications Speaker and microphone included Control output (open collector) Call switch input LED Status Indicator output 67 (W) 128.3 (H) 26 (D)mm (2.64" 5.05" 1.02") 100g (0.22 lb) (including accessories)

RS-150 Substation Provides half-duplex communication Hairline brushed stainless steel faceplate Connects to N-8000RS/8010RS using two-core shielded cable 120 (W) 120 (H) 48.5 (D)mm (4.72" 4.72" 1.91") 410g (0.90 lb) RS-160 Substation Provides half-duplex communication Heavy-duty brushed stainless steel faceplate Vandal resistant call button Connects to N-8000RS/8010RS using two -core shielded cable 120 (W) 120 (H) 57.5 (D)mm (4.72" 4.72" 2.26 ) 540g (1.19 lb) RS-170 Substation Provides half-duplex communication. Heavy-duty brushed stainless steel faceplate Vandal resistant call button Weather resistant conformal printed circuit board coating Connects to N-8000RS/8010RS using two-core shielded cable 120 (W) 120 (H) 57.5 (D)mm (4.72" 4.72" 2.26") 540g (1.19 lb) RS-180 Substation Provides half-duplex communication Heavy-duty brushed stainless steel faceplate Red vandal resistant call button Control output - open collector type for external relay control Weather resistant conformal printed circuit board coating Connects to N-8000RS/8010RS using two-core shielded cable 120 (W) 120 (H) 58.5 (D)mm (4.72" 4.72" 2.30") 570g (1.26 lb) RS-140 Switch Panel Call button and privacy button Talk back conversation Prevents from in-coming call by pushing a privacy switch Handset conversation available by using with RS-141 Hands-free conversation with master station by connecting a high impedance speaker Connects to N-8000RS/8010RS using two-core shielded cable RS-450 Substation Provides half-duplex communication Hairline brushed stainless steel faceplate Built-in electret condenser microphone Connects to N-8400RS using two pairs of twisted pair cables 120 (W) 120 (H) 48.5 (D)mm (4.72" 4.72" 1.91") 410g (0.90 lb) RS-142 IP Intercom Switch Board For 2 momentary switches Handset conversation available by using with RS-141 Connects to N-8000RS/8010RS using two-core shielded cable RS-143 IP Intercom Switch Panel Call button Handset conversation available by using with RS-141 Hands-free conversation with master station by connecting a high impedance speaker Connects to N-8000RS/8010RS using two-core shielded cable RS-144 IP Intercom Switch Panel Emergency button and normal button Handset conversation available by using with RS-141 Hands-free conversation with master station by connecting a high impedance speaker Connects to N-8000RS/8010RS using two-core shielded cable RS-141 Option Handset Indoor handset used with RS-140 Switch Panel RS-460 Substation Provides half-duplex communication Heavy-duty brushed stainless steel faceplate Vandal resistant call button Built-in electret condenser microphone Connects to N-8400RS using two pairs of twisted pair cables 120 (W) 120 (H) 57.5 (D)mm (4.72" 4.72" 2.26 ) 540g (1.19 lb) RS-470 Substation Provides half-duplex communication. Dustproof and waterproof construction (IP54 rating) Heavy-duty brushed stainless steel faceplate Vandal resistant call button Weather resistant conformal printed circuit board coating Built-in electret condenser microphone Connects to N-8400RS using two pairs of twisted pair cables 120 (W) 120 (H) 57.5 (D)mm (4.72" 4.72" 2.26") 540g (1.19 lb) RS-480 Substation Provides half-duplex communication Dustproof and waterproof construction (IP54 rating) Heavy-duty brushed stainless steel faceplate Red vandal resistant call button Control output - open collector type for external relay control Weather resistant conformal printed circuit board coating Built-in electret condenser microphone Connects to N-8400RS using two pairs of twisted pair cables 120 (W) 120 (H) 58.5 (D)mm (4.72" 4.72" 2.30") 570g (1.26 lb) RS-481 Option Handset Indoor handset used with RS-480 Substation

YC-850 Wall Mount Bracket Designed to mount N-8000RS, N-8010RS, N-8400RS, N-8000DI, N-8000AF, N-8000AL and N-8000CO interface units on a wall. YC-280 Wall Mount Bracket Designed to mount N-8000MS, N-8010MS, N-8020MS, N-8500MS and N-8510MS on a wall. YC-290 Wall Mount Bracket Designed to mount N-8011MS on a wall. YC-251 Surface-Mount Back Box Designed to mount N-8031MS Flush-mount Hands-free Master Station on a wall. YC-241 Flush-Mount Back Box Designed to surface-mount N-8031MS Flush-mount Hands-free Master Station on a wall. YC-150 Flush-Mount Back Box Designed to flush-mount N-8050DS and N-8540DS Door Stations on a wall. YC-801 Flush-Mount Box Designed to flush-mount RS-140 Switch Panel on a wall. YS-13A Surface-Mount Back Box Designed to surface-mount N-8050DS and N-8540DS Door Stations on a wall. YC-802 Wall Mount Box Designed to mount RS-140 Switch Panel on a wall. YC-302 2-Gang Electrical Box The YC-302 is a 2-Gang electrical box (with cover) of wall flush mount type. AD-1215P AC Adapter The AD-1215P is an AC adapter to operate the IP Station on AC. Human Society with Sound & Communication TOA Corporation www.toa.jp Specifications are subject to change without notice. Printed in Japan (1111) 833-52-325-5C u