CSH24CH. Colored Light Strobe/Horn Series High Candela. Description. Features. Ceiling/Wall Mount Patent Pending. Ordering Information

Similar documents
SELECT-A-HORN/STROBE SERIES

Potter Wall Mount Select-A-Strobe

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

MEA. SpectrAlert Series Horns, Strobes, and Horn/Strobes GENERAL

L-Series, Emergency Communication Devices

L-Series, Indoor Strobes and Horn Strobes

SpectrAlert Advance. Field-Selectable Mass Notification Devices. Description. An ISO Company SIGNALING. MEA Approved E

L-Series, Indoor Strobes and Horn Strobes

s Notification Appliances

Wheelock RSS & RSSP Series

TrueAlert Multi-Candela Notification Appliances

TrueAlert Notification Appliances

08 Series Notification Appliances AS / AH & AS Audible Strobe Appliances and AH Audibles Application: Indoor / Outdoor

TrueAlert Multi-Candela Notification Appliances

Selectable Output Chimes and Chime/Strobes

'08 Series Notification A liances

TrueAlert Addressable Notification Appliances

Field Configurable Horns and Strobes

Field Configurable Horns and Strobes

Dimensions of the Optional Mounting Box (BB-400R/W)

Signature Series Auto-Sync Output Module (CC1S)

The Advance You ve Been Looking For

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

TrueAlert Addressable Notification Appliances

Speakers and Speaker Strobes

11:00 to 12:00 Secrets to achieving code-compliant strobe installations. Ralph Coco, Potter Canada Paul Jewett, Mircom Group of Companies

advancedsolutions Advanced Design. We have engineered all SpectrAlert products to meet or exceed code today and tomorrow. We ve worked to standardize

ELECTRONIC SOUNDER STROBE Model : AVD-C407

AL602ULADA AL802ULADA AL1002ULADA

TrueAlert Addressable Notification Appliances

Life safety notification

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

AL800ULADA. NAC Power Extender. Installation Guide

LifeAlarm Fire Alarm Controls

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Addressable Fire Alarm Control Panel

TrueAlert ES Addressable Notification Appliances

*15cd models are Listed at 15cd and meet 75cd on axis

Installation Instructions Model ABHW-4S

Genesis LED G1 Series

L-Series Audible Visible Notification PRODUCTS. Accessories Chimes Chime Strobes ECS and MNS Horns Horn Strobes Speakers Speakers Strobes Strobes

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

1. POWERPATH Operation

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Agent Release Control Panel

AL600ULADA. NAC Power Extender. Installation Guide

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

Signaling Devices. Acoustic Signaling Devices 298. Optical Signaling Devices 309. Bosch Security Systems B.V.

Table 1: dba Ratings for AMT Multitone Signal Typical Anechoic dba at 10 Feet per CAN/ULC S525-07

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

INSTRUCTION & SERVICE MANUAL

Fire Safety. Installation Instructions. Model ADBX-11. Audible Base INTRODUCTION. Model ADBX-11

FIRE ALARM Submittal DR. PECK FHM DAYTONA 4TH FL 125 MEMORIAL MEDICAL PARKWAY DAYTONA BEACH, FL 32117

Addressable Detectors & Bases

Autonomous control unit

SAFEPATH Mass Notification System (SPMNS)

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Analog fire panels FPA-1000 Family

LifeAlarm Fire Alarm Control Panels

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

Conventional Audible Visual Range

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

TrueAlert Addressable Notification Appliances

Fire Safety Products Conventional Detection Audible/Visible Notification HVAC Systems Monitoring Sprinkler Systems Monitoring

OPERATING AND INSTALLATION

Hazardous Location Supervised Warning Light

31566 Railroad Canyon Road STE 2 Canyon Lake, CA Office Fax

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Electric Release Panel Wiring Tips

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

DETCON MODEL AV1/AV2-C1D2M Hazardous Duty Class I. Div 2, Multitone Alarm Station

SP40S-D. Kingfisher Company, inc. Features: Description:

MODEL AV2-C1D1M Hazardous Duty Class I. Div 1, Multitone Alarm Station

GEC Low-frequency Horn Strobes

MODEL Distributed Power Module. Installation and Operations Manual. Part Number Rev L

Fire Alarm Devices. Drexel Thrash Laborers Training Center. Supplier: Tri S Controls

TECHNICAL DATA OBSOLETE

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Specification/ Data Sheet

X10 Mini, Midi & Maxi

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Honeywell Power Products

STI-1229-HAZ STI-1229HTR-HAZ STI-1229HTR240-HAZ

MODEL Intelligent Power Module. Installation and Operations Manual. Document /12/10 Rev: E1 P/N :E1 ECN:

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

"SS90" SERIES CONTROLS MODEL C INSTALLATION MANUAL

SECTION FIRE ALARM SYSTEMS

FA-1000 SERIES. Microprocessor-Based Fire Alarm Control Panel. Installation and Operation Manual

LIFESAVER MODEL SL240 REMOTE VISUAL SIGNALLING DEVICE (STROBE LIGHT)

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

INSTRUCTION & SERVICE MANUAL

Conventional Fire Detection

Transcription:

OF FIRE CS24C Colored Light Strobe/orn Series igh Candela Ceiling/Wall Mount Patent Pending Description AMSECO's UL listed Colored Light Strobe CS24C series is designed to provide audible and visual signals for Fire Alarm Protection Systems and notification signals for the purpose of life safety and property protection. They meet or exceed NFPA/ANSI standards and UL 464/UL638. The CS24C is a Select-A-orn with the highest strobe light output (non-selectable candela). The colored light is available in,, and. The light output candela ratings vary depending on the lens color. In those instances where two or more AMSECO horns and/or strobes are connected and requires a synchronized code 3 temporal pattern and/or a synchronized strobe flash, all models can be synchronized when used in conjunction with AMSECO UL listed Sync module SMD-3A to meet the latest code. Features Available colored lights: amber, blue, green, red NFPA/ANSI compliant UL listed for Ceiling/Wall Mounting under UL 638 Designed for use in non-sleeping areas Screw terminal capacity up to 2 AWG Polarized strobes with wide operating voltage range using filtered DC or unfiltered FWR input voltage orn field selectable tones: 3z interrupted or mechanical Temporal or Non-temporal igh or Low dba output Minimum one flash per second (z) All models mount to 4" X 4" X -fi" back box Synchronization requires an AMSECO SMD-3A Sync Module RBX- back box skirt for surface mount (optional) The SPC- retrofit plate allows mounting to a variety of back boxes Available in red or white housing C US L I S T I NG S E R V CALIFORNIA MARSALL I C E Ordering Information Model Number Colored Light ousing Color Input Voltage Strobe Candela Mounting Type Light Output Flash Rate (Times/min) Sync Module Temperature Range CS24C-AW CS24C-BW CS24C-GW CS24C-RW CS24C-WW CS24C-AR CS24C-BR CS24C-GR CS24C-RR CS24C-WR 24V DC/FWR 38 38 38 38 Wall or Ceiling Mount Non- Selectable 6 SMD-3A 32 F ~ 2 F ( C ~ C)

Engineering Specifications The audible and colored visual alarm indicating appliance shall be AMSECO model CS24C or equivalent device. The orn/strobe shall be listed under UL 97 and UL 638 Standard for signaling devices and shall be approved for fire protective and emergency services. The reflective mirror shall be of the same color as the lens of amber, blue, green, or red. The candela output shall have a single setting of igh intensity output. The orn shall provide two different field selectable tones and a igh and Low field sound output setting. The signaling orn/strobe shall operate on 24VDC from a non-coded regulated DC supply or full-wave rectified, unfiltered supply. The signaling strobe shall be designed to produce a signal flash of one flash per second with continuously applied minimum voltage. The orn/strobe shall be capable of CEILG and WALL mounting to a variety of back boxes using the AMSECO SPC- retrofit back plate. When strobe synchronization is required, the orn/strobe shall be compatible with the AMSECO SMD-3A (daisy chain) or other source of AMSECO sync protocol. Strobe Selectable Candela Output Select-A-Switch Select either Low, Mid or igh and replace cap on front of unit. Dimensions: Inches (mm) 4" Square outlet box /2" Deep 3-3/8 (85.7) 6-7/8 () -3/32 (35) 2-25/32 (7) 3-3/8 (85.7) Top View Side View Back View Wiring Diagrams Example : Colored light WIRG WIRG 2 Signal Operates Independently Refer to Fig. Control Panel To Next Device or End-of-Line Resistor STROBE ORN To Next Device or End-of-Line Resistor WIRG 3 Wiring Diagram for Audble Strobe Class "B" with Audible Silence Feature. (CS24W) Refer to Fig. 2 Strobe Signal orn Signal SYNC MODULE SMD-3A PUT PUT Fig. orn/strobe WIRG 4 Wiring Diagram for Audble Strobe Class "B" without Audible Silence Feature. Signal SYNC MODULE SMD-3A PUT PUT Refer to Fig. 2 Fig.2 STROBE ORN orn/strobe Factory setting jumper wire STROBE ORN WARNG The Strobe/orn must be used only on circuits with continuously operating voltage. DO NOT use strobe on coded or interrupted circuits in which the applied voltage is interrupted ON and OFF as the strobe may fail to flash. The applied voltage must be within its rated input voltage range. Fuse ratingson signaling circuits must handle peak currents from all devices connected to those circuits.

orn Selectable Jumper Setting Fig. A TONE SELECT JUMPER Factory setting PC3PC2PC Fig. B PC3 JUMPER PATTERN PC2 PC TONE VOLUME NON ELECTRO TEMPORAL MECANICAL TEMPORAL 3z Specifications Strobe/orn Current Draw Table orn & Strobe orn ONLY Non-Temp. Temporal Non-Temp. Temporal 3 z 3 z 3 z 3 z PC3: Pattern PC2: Tone PC: Volume PC3 PC2 PC Max. RMS Current (marms) 42 42 42 42 24V FWR 5 5 5 5 Min. Sound Output (dba @ ft per UL464) 86 76 87 77 8 73 82 86 76 87 77 8 73 82 Strobe Light ONLY Max. RMS Current (marms) Light Output Dispersion 24V FWR 359 2 Sound Output Dispersion DEGREES +9 +6 +3-3 -6 orizontal db db db -3dB Light Output on Axis (cd) 38 38 Vertical -5dB -db db -db -9-6dB -5dB Installation and Mounting Options SPC- Universal Retrofit Plate: designed for mounting to a variety of back boxes. RBX- Skirt: for surface mount installations. Single Gang Double Gang Octagon 4 Square SPC- SPC- SPC- 4 Square RBX- Back Box Skirt RBX- RBX- RBX- CS24C

OF FIRE SMD-3A Sync Module L I S T I NG CALIFORNIA S E R V MARSALL I C E Description The Sync Module is designed to provide a synchronized temporal pattern (code 3) tone, and synchronize the strobe flashes when used with AMSECOs Select-A- Strobe, Select-A-orn, and Select-A-orn/Strobe series as well as the ability to silence the horn while maintaining the strobe flashes. The SMD-3A has the capability of connecting two style Y (Class B) circuits or one style Z (Class A) circuit and is rated for 3 Amperes per circuit. Features Polarized with wide operating voltage range using filtered DC or unfiltered FWR input voltage Mounts onto 4-inch square back box Daisy chain up to 2 modules maximum Screw terminal capacity up to AWG#2 metal plate The SMD-3A can be interconnected so that more than 2 alarm zones can be synchronized by connecting the SYNC terminals (daisy chain connection). The maximum number of interconnected modules is twenty. All inputs are polarized for compatibility with standard reverse polarity supervision of circuit wiring by Compatible AMSECO products S24W-5375 SL24W-5375 SB24-75 SAD24-5375 RSD24-5375 SCM24W-375 S24W-75 SL24W-75 SLB24-75 SAD24-75 RSD24-75 SCM24W-77 24W SA24 Series SB24 Series Colored Light Strobe Series Specification Input Voltage Voltage Range Maximum Load on Loop Max. RMS Current DC FWR Mounting Temperature Range 24V DC/FWR 6 ~ 33V DC/FWR 3A Average Max. 5A Peak ma 68mA 4 x 4 x -/2 32 F ~ 2 F ( C ~ C) Dimensions: inches(mm) 4.33 () 3.3 (85.7) 4.33 () 3.3 (85.7).2 (5) Daisy Chain Modules No. No.2 No.2 (max.) SMD-3A +PUT +PUT - GND +PUT2 +PUT2 + - SMD-3A +PUT +PUT - GND +PUT2 +PUT2 + - SMD-3A +PUT +PUT - GND +PUT2 + - +PUT2 *Due to continuous development of our product line, specifications are subject to change without notice. CS24C /24