Lo-Carbon Quadra Centrifugal Fan

Similar documents
Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon Quadra SELV

Silhouette Installation and Wiring Instructions

Centrif Duo & Centrif Duo Plus

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

HR200WK Through the wall Heat Recovery Ventilator

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon SELV Tempra

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Lo-Carbon PoziDry Pro

Lo-Carbon T-series Window & Roof Models

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

SUPER T WALL FANS. Installation and Wiring Instructions

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

Installation and Wiring Instructions

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

Sentinel. Kinetic Advance MVHR. Installation & Commissioning. Stock Ref. N Advance S Advance SX

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

Sentinel Kinetic MVHR RANGE

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Installation & Operating Instructions

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

G Installation manual Solitude - dmev unit

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

100 FLUEBOOST

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Simply Silent Contour 4 (100mm) Axial Extraction Fan

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

Model: Kair Whole House Ventilator Model Number: KHRVWH2000

Warnings, Safety Information and Guidance

FLUEBOOST. flueboost 350 gas fire model

Centrifugal extract and condensation control fans

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Installation manual Mori HR

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

Xpelair Simply Silent TM Contour Fan

KADO LUX LED EXHAUST FAN 200

KUDOS. Instruction leaflet

Stainless Steel Chimney Extractor

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

Installation & Operating Instructions

Xpelair Simply Silent DX150

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

CI/SfB (57.7) 2nd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

Stainless Steel Chimney Extractor

Lo-Carbon Sentinel Kinetic Horizontal

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

INSTALLATION INSTRUCTIONS USER GUIDE

Xpelair Simply Silent TM DX100 Fan

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

WHHR Midi & Midi Lite

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

MEV SPIDER INSTALLATION GUIDE FOR ENGINEER / INSTALLER

HOTLINE:

White - Non Illuminated Art no White - Cool White LED Art no.32600

aura-t TP536/GBR ventilation systems

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

ELTA FANS IN-LINE MIXED FLOW FAN IMF100 / 125 / 150 / 200 INCLUDING MODELS WITH BUILT-IN-RUN-ON TIMERS T

Xpelair Simply Silent DX100

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

AXIAL FANS USER S MANUAL

MODEL: BV400 Part No:

Stainless Steel T-Box Extractor

Installation and Maintenance

User and maintenance manual

Turbo Inline Fan, White - Non Illuminated Art no.33500

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

"Microbox" Continuous Mechanical Extract Ventilation Units. Installation, Operating and Maintenance Instructions

Green Line CMX. Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions. Model: CMX

Installation and Maintenance

Decentralised Mechanical Extract Ventilation 2 Speed Axial Extract Fan Installation Guide. Fig. 2 Fan components.

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition.

Sentinel. Kinetic MVHR Range. Installation & Commissioning. Stock Ref. N PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Centair CMEV.4 / CMEV.4e / CMEV.4eHT Mechanical Extract Ventilation (MEV) System Installation Instructions

Domestic & Commercial Fans

l i nda b we si mpl i f y c onstr u ction Conforms ErP Ecodesign Lot 6 Residential and non-residential air handling units

Thank you for choosing EnviroVent

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

Transcription:

Lo-Carbon Quadra Centrifugal Fan Installation and Wiring Instructions Stock Ref. N Quadra TP Quadra TM Quadra HTP 439251A 439253A 439181A 220-240V~50Hz IPX4 PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Technical Specifications (Tested at 240 VAC @ 50Hz): Air Performance: 6, 9, 12, 15, 30 or 60 l/s (22, 32, 43, 54, 108 or 216 m³/h). Power consumption: 3-45W. Exhaust spigot diameter: Ø100mm. Installed size: 260 x 230 x 112 mm (when surface mounted) Features: Surface mountable. Can be flush mounted with optional accessory kit (439256). Optional Filter available as an accessory (439927). Option to boost from constant trickle or from off. Three trickle speed options available, selectable during installation (6, 9 or 12 l/s). Three boost speed options available, selectable during installation (15, 30 or 60 l/s). LS connection (remote switch can switch the fan from the off or trickle state to boost). Adjustable timer overrun (1-30 minutes approximately). Variable speed boost for humidity models. Model Specific Methods to Select Boost Speed: TP TM HTP Pullcord Movement sensor (P.I.R) Adjustable relative humidity sensor

INSTALLATION AND WIRING INSTRUCTIONS IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures higher than 40 C or less than 5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. It is recommended that the connection to the fan connector terminals is made with flexible cable. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. J. Children should be supervised to ensure that they do not play with the appliance. DESCRIPTION As standard, the Quadra is suitable for panel/ceiling or wall installations and surface mounting either in a horizontal or vertical plane. A Flush Mount Kit (439256) is available as an accessory. Ø100mm ducting (flexible or rigid) can be attached providing rear exit as standard or side exit with the Flush Mount Kit. Adaptors for rectangular ducting can be used. For wall installations a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. Please see our catalogue or web site (www.ventaxia.com) for more information on alternative ducting and termination options. A Filter (439927) is available as an accessory.

A. INSTALLATION A Backdraught Shutter Assembly is supplied. It is packed inside the product during transport. It is designed to block the duct when the fan is off in order to prevent cold draughts from outside entering the building. If you are going to set the fan up to extract air continuously (constant trickle), you do not necessarily need it. To use it, push it on to the end of the exhaust Spigot with the hinges on the flaps vertical (fig.1). IMPORTANT: Be careful to avoid joists and hidden pipes or cables when cutting or drilling holes. SURFACE MOUNTING (PANEL/CEILING) 1. Remove the Front Cover Assembly by slackening the 2 Cover Screws by 2 turns (fig.2.) Lift the Cover Assembly away from the bottom edge then the top edge. 2. Cut a 105mm hole and suitable screw holes in the panel, ensuring that there is sufficient space for the product to be installed and that the optional Filter (fig.3) could be removed for cleaning. The cardboard fitment in the packaging can be used as a template. 3. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 4. Remove the small Internal Cover that covers the Terminal Block in the top right corner (fig.3). 5. Attach the ducting to the Spigot and locate the Fan into the hole in the panel. Feed wiring through the hole in the Chassis next to the Terminal Block as you do so. (fig. 4) 6. Secure into position using appropriate screws and rawl plugs. 7. Select and follow the appropriate wiring diagram in Section C WIRING. 8. Replace the Internal Cover over the Terminal Block. 9. Ensure the Impeller rotates freely. 10. Replace the Front Cover Assembly and tighten the two screws. 11. Switch the mains power supply on and check the fan is operating correctly. SURFACE MOUNTING (WALL) For through-the-wall installations, a Wall Kit (25 41 02 White / 25 41 00 Brown) can be used. 1. Remove the Front Cover Assembly by slackening the 2 Cover Screws by 2 turns (fig.2.) Lift the front assembly away from the bottom edge then the top edge. 2. Cut a 117mm hole through the wall, ensuring that there is sufficient space for the product to be installed and that the optional Filter (fig.3) can be removed for maintenance. The cardboard fitment inside the packaging can be used as a template. 3. Insert the wall sleeve with the larger diameter sleeve on the room-side and cement the ends into position flush with the wall faces. The wall sleeve should be angled downwards, away from the Fan, to allow any condensation to drain to outside. 4. Outside Grille (available separately): Using the Grille s Back Plate as a template, mark the fixing hole centres on the wall. Drill and plug the wall and fix the Grille into position. Ensure the louvres are pointing downwards. 5. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 6. Remove the small Internal Cover that covers the Terminal Block in the top right corner (fig 3). 7. Using the Fan Chassis as a template, carefully sliding the spigot into the Wall Liner, mark the fixing hole centres on the wall. 8. Drill and plug the wall using the fixings provided. 9. Feed the wiring through the hole near the Terminal Block (fig.4) and secure the Fan into position using the screws provided. 10. Select and follow the appropriate wiring diagram in Section C WIRING. 11. Replace the Internal Cover over the Terminal Block. 12. Ensure the Impeller (fig.3) rotates freely. 13. Replace the Front Cover Assembly and tighten the two screws. 14. Switch the mains power supply on and check the fan is operating correctly

FLUSH MOUNTING (PANEL/CEILING) A Flush Mount Kit (439256) is required. 1. Remove the Front Assembly by slackening 2 Cover Screws by 2 turns (fig.2). Lift the front assembly away from the bottom edge then the top edge. 2. Mark and cut a rectangular hole 225mm (w) x 255mm (h) through the panel ensuring that there is sufficient space for the product to be installed and that the optional Filter (fig.3) can be removed for maintenance. 3. Remove the Back Box by removing the 4 screws. Replace it with the Frame from the Accessory Kit 439256. (Fig 5). 4. Slide each Panel Clip in to the Chassis then pass each of the long Panel Clip Screws (supplied in the kit) fully through the flange of the Chassis and screw in to the Panel Clips (fig.6.) allowing enough space between the Panel Clip and the flange for the thickness of the panel (so that the clips can spring open behind the panel). 5. Set-up the appropriate speed selection and other features as outlined in Section B SETUP. 6. Remove the Internal Terminal Block Cover that covers the Terminal Block in the top right corner (fig 3 & 4). 7. Attach the ducting to the Spigot and locate into the hole in the panel, ensuring the cable is fed into the Fan Chassis (fig.4) and the Panel Clips spring out behind the panel. 8. Secure into position by carefully tightening the 4 Panel Clip Screws. IMPORTANT: If power tools are used, set them to the minimum torque setting or preferably use a manual screwdriver. Do not over tighten. 9. Select and follow the appropriate wiring diagram in Section C WIRING. 10. Replace the Internal Cover over the Terminal Block. 11. Ensure the Impeller rotates freely (fig.3). 12. Replace the Front Cover Assembly and tighten the two screws. 13. Switch the mains power supply on and check the fan is operating correctly. B. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE. IMPORTANT On first power up, the fan will run through its initialization routine. On TP, HTP & TM models the fan will switch on and off during this routine (Including the LED) Once complete after approximately 2 minutes, the fan will run as normal. With the Cover removed the humidity adjustment, overrun timer adjustment, speed selection switches and installation type switches are accessible in the bottom right corner of the product (figs.4 & 7). 1. SELECTING THE CONSTANT TRICKLE SPEED (0, 6, 9 or 12 l/s) This will determine the speed at which the fan will run most of the time except when boost is activated by either the Pullcord, PIR, LS, or Relative Humidity Sensor. i. Slide one of the three switches marked as Normal/Trickle Speed in fig.7 to the right (on position) to select that flow rate for trickle speed. ii. Setting all of those 3 switches to the left (off positions) will switch off the constant trickle option (i.e the fan will normally be off and will switch to boost when the Pullcord, PIR, LS or Humidity Sensor are activated).

2. SELECTING THE BOOST SPEED (15, 30 or 60 l/s) This will determine the speed at which the fan will run when activated by either the Pullcord, PIR, LS, or Relative Humidity Sensor (note: the %RH boost speed is 50% of the set boost flow rate see Relative Humidity Adjustment section below). i. Slide one of the three switches marked as Boost Speed in fig.7 to the right (on position) to select that flow rate for boost speed. 3. TIMER ADJUSTMENT The overrun time period is the length of time that the fan will continue to run at boost for after the LS connection is switched off or the PIR (Quadra TM only) stops sensing movement. It is factory set to approximately 15 minutes. The overrun time period may be adjusted from approximately 1-30 mins by altering the adjuster on the control PCB. (figs.4 & 7). i. To REDUCE the operating time, turn the adjuster ANTI-CLOCKWISE. ii. To INCREASE the operating time, turn the adjuster CLOCKWISE. 4. RELATIVE HUMIDITY ADJUSTMENT (HTP model only) The fan s Relative Humidity (RH) Set-Point is factory set to switch the fan on at about 72%RH. The fan will increase the flow rate proportionally with %RH to 50% of the set boost speed. If constant trickle is selected, the fan will increase the flow rate from the set trickle rate to 50% of the boost rate. To Boost the fan to 100% of the boost rate use the integral pullcord or remote switch via the LS connection. i. To LOWER the Set-Point, turn the Humidity Adjuster (figs.4 & 7) ANTI-CLOCKWISE. This makes the fan more sensitive to RH%, i.e. the fan will come on at a lower RH%. ii. To RAISE the Set-Point, turn the Humidity Adjuster (figs.4 & 7) CLOCKWISE. This makes the fan less sensitive to RH%, i.e. the fan will come on at a higher RH%. C. WIRING. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING INSTALLATION OR MAINTENANCE. Use 0.75mm 2 cable 1. Select and follow the appropriate wiring diagram (figs. 9 & 10). 2. Additional controls, such as room mounted humidistats, pullcords, PIR sensors and normal/boost switches, can be connected to the LS connection instead of the room lighting circuit in fig 10 in order to make the fan boost. These accessories must switch a 240V 50Hz live connection on when boost is wanted. 3. Use the Cable Clamp provided. 4. Check all connections have been made correctly and ensure all terminal connections are securely fastened. D. SERVICING AND MAINTENANCE. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING SERVICING OR MAINTENANCE. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits. 2. If you have a Filter (fig.3), remove it by using a small, flat bladed screwdriver to lift the bottom edge over the retaining edge (fig.2) and then slide the filter out.

3. Remove the Cover assembly by slackening the two cover screws (fig.2) by two turns and pull it away. 4. Remove the Impeller (fig.3) by pressing the two clips together in the middle and pulling it off the Motor. 5. Wipe the outside of the fan with a damp (not dripping wet) cloth until clean. 6. Wash the Filter, Cover Assembly and Impeller in warm, soapy water if they are dirty. Do not use abrasive cleaners. Dry the parts before replacing them. 7. Turn the power to the Fan back on. The fan has sealed for life bearings, which do not require lubrication. Fig.1. Backdraught shutter assembly. Flaps vertical. Spigot. Fig.2. Cover Assembly. Cover Screws. Retaining edge for optional Filter. Insert flat bladed screwdriver in here to remove Filter.

Fig.3. Internal Terminal Block Cover. Spigot. Cover Assembly. Chassis Assembly. Impeller. Optional Filter. Fig.4. Internal Terminal Block Cover. Cable Clamp. Terminal Block. Timer and Humidity Adjustment. Speed and Installation Type Switches.

Fig.5. Frame from optional Flush Mount Kit. Back Box. Fig.6. Panel Clip Screw (4 off). Panel Clip (4 off).

Fig.7. Timer adjustment. Turn clockwise to increase overrun timer. Humidity Setpoint Adjustment. Turn clockwise to raise set point. Off On 60 30 15 12 9 6 Boost Speed (l/s) Normal/Trickle Speed (l/s) Speed Selection Switches. (Factory setting shown is boost speed of 15 l/s and normal/trickle speed of 6 l/s.) Installation Type Selection Switches: Through the wall installation. 1.5m Ø100mm ducting with one 90 bend and a wall grille. (Factory setting) 3m Ø100mm ducting with two 90 bends and a wall grille.

Fig 8. Siting of the fan. Fig 9. Wiring diagram without LS connection. 1 Phase Supply (220-240V 50 Hz) L ~ N 3A Fuse L N Fan 2 Pole Isolator Switch Pull Cord (if applicable) Fig 10. Wiring diagram with LS connection. 1 Phase Supply (220-240V 50 Hz) 3A Fuse Pull Cord Ceiling Junction Lamp 3 Pole Isolator Switch Fan N L Ls Pull Cord (if applicable)

PRODUCT FICHE For Residential Ventilation Units (Complying Commission Delegated Regulation (EU) No 1254/2014) Name: Vent-Axia Vent-Axia Vent-Axia Model ID (Stock Ref.) : Lo-Carbon Quadra TP - 439251 Lo-Carbon Quadra HTP - 439181 SEC Class D D D SEC Value ('Average') 26.23 26.23 26.23 SEC Value ('Warm') 11.86 11.86 11.86 SEC Value ('Cold') 51.31 51.31 51.31 Label Required? (Yes/No=Out of scope) Yes Yes Yes Declared as: RVU or NRVU/UVU or BVU RVU-UVU RVU-UVU RVU-UVU Speed Drive 2-Speed 2-Speed 2-Speed Type HRS (Recuperative, Regenerative, None) None None None Thermal Eff: [ (%), NA(if none)] N/A N/A N/A Max. Flow Rate (m3/h) 226.80 226.80 226.80 Max. Power Input (W): (@Max.Flow Rate) 38.00 38.00 38.00 LWA: Sound Power Level (db) 37.52 37.52 37.52 Ref. Flow Rate (m3/s) 0.04 0.04 0.04 Ref. Pressure Diff. (Pa) 120.00 120.00 120.00 SPI [W/(m3/h)] 0.24 0.24 0.24 Control Factor & Control Typology: (CTRL/ Typology) Control Factor; CTRL 0.65 0.65 0.65 Lo-Carbon Quadra TM - 439253 Control Typology Clock Control Local Demand Control Local Demand Control Declared: -Max Internal & External Leakage Rates(%) for BVUs or carry over (for regenerative heat exchangers only), -&Ext. Leakage Rates (%) for Ducted UVUs; N/A N/A N/A Mixing Rate of Non-Ducted BVUs not intended to be equipped with one duct connection on either supply or extract air side; Position and description of visual filter warning for RVUs intended for use with filters, including text pointing out the importance of regular filter changes for performance and energy efficiency of the unit N/A N/A N/A N/A N/A N/A For UVUs (Instructions Install Regulated Supply/Extract Grilles Façade) In F&W In F&W In F&W Internet Address (for Disassembly Instructions) www.vent-axia.com www.vent-axia.com www.vent-axia.com Sensitivity p. Variation@+20/-20 Pa: (for Non-Ducted Vus) N/A N/A N/A Air Tightness-ID/OD-(m3/h) (for Non-Ducted Vus) N/A N/A N/A Annual Electricity Consumption: AEC (kwh/a) 1.97 1.97 1.97 Annual Heating Saved: AHS (kwh/a) AHS: Average 26.23 26.23 26.23 AHS: Warm 11.86 11.86 11.86 AHS: Cold 51.31 51.31 51.31

The Guarantee Applicable only to products installed and used in the United Kingdom. For details of guarantee outside the United Kingdom contact your local supplier. Vent-Axia guarantees its products for two years from date of purchase against faulty material or workmanship. In the event of any part being found to be defective, the product will be repaired, or at the Company s option replaced, without charge, provided that the product:- Has been installed and used in accordance with the instructions given with each unit. Has not been connected to an unsuitable electricity supply. (The correct electricity supply voltage is shown on the product rating label attached to the unit). Has not been subjected to misuse, neglect or damage. Has not been modified or repaired by any person not authorised by the company. IF CLAIMING UNDER TERMS OF GUARANTEE Please return the complete product, carriage paid to your original supplier or nearest Vent-Axia Centre, by post or personal visit. Please ensure that it is adequately packed and accompanied by a letter clearly marked Guarantee Claim stating the nature of the fault and providing evidence of date and source of purchase. The guarantee is offered to you as an extra benefit, and does not effect your legal rights Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 856 0590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0344 856 0594 Fax: 01293 532814 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 403585B 0916