V. Aa. Gram A/S

Similar documents
V. Aa. Gram A/S

V. Aa. Gram A/S FAN TEST. Erp 2013 and 2015 (EU-regulation no. 327/2011) 1. Overall efficiency. 2. Measurement category used

Capture at Source FILTERMAX FILTER MODULES WITH AUTOMATIC CLEANING

INDUSTRIAL VACUUM CLEANING INNOVATION. Industrial vacuum cleaners

CE Unit is suitable for material transport. The transported gas may be up to 80 C.

MJC Cartridge Filter Unit Operation & Maintenance

Fume Extraction Solutions. We care for your working environment.

Heavy Vac. Industrial vacuum cleaners powerful, versatile and easy to manage. nuove aspirazioni new vacuums, new ambitions

Part No KEMPER Filter-Master XL

INDUSTRIAL CENTRAL VACUUM CLEANING

Oil Mist Separator Unit LGA 600 FUW

Weller. Zero-Smog Filter Systems. Tip Extraction. Volume Extraction

Control unit PPT/RS,, Controls the functions of the conveyor. Fully pneumatic. The maximum recommended distance between the conveyor and contr

Oil Mist Separator Unit LGA 600 FUW

ingle phase three phase hoppers central systems single phase three phase hoppers central syste CONVEYING

MJC Mini. Cartridge Filter. Features. Principal specification and options

User s Manual MATRIX A MATRIX S MATRIX A. Filtro de aspiración Movil Matrix Tel.

ALUMINUM REPAIR CERTIFICATION EQUIPMENT. Eliminate hazardous aluminum dust with a Eurovac system. BODY REPAIR CERTIFICATION EII Wet Mix Dust Collector

CONVEYING. Central conveying systems for granulate METRO G

WHY CHOOSE AN EXTREME DUTY MULTI VAC INDUSTRIAL VACUUM SYSTEM?

Nederman Norclean Line Product Catalogue. Vacuum transportation systems Vacuum cleaning systems Vacuum Solutions

PRODUCT FULL NAME. dust control featuring tool & vacuum system

Transport material Venturi Feeder Single Phase Hopper Loaders 3-Phase Hopper Loaders Centralised feeding systems Supervision

Industrial Dust Aspiration Solutions. For optimal protection of plant and environment.

FILTERCUBE 2N We set air in motion

VARIO eco Dust Collector. For the highly effective, energy efficient collection of dust from industrial processes. Standard for clean air

FMC(Z) cartridge filter

Operating instructions

ADSORPTION DRYING: WHY?

Dust Collectors. Unique Design & Engineering Approaches for Dust Collection and Pneumatic Conveying

471A configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distance

Phone: Fax :

Filtering Division. Dust collectors. MIX S.r.l. MIXING SYSTEMS AND COMPONENTS FOR PLANTS ATEX-RATED PRODUCTS AVAILABLE CF/162

Strong Central Vacuum Cleaning System

System Components. Vacuum stations, Central filter systems, Vacuum receivers & Piping systems

piflow Conveyor Customer Code

TURBO AND HIGH PRESSURE REGENERATIVE BLOWERS

MJC cartridge dust collector

(Container with bottom unload) AV high vacuum. Description. COMPACT 30 kw. COMPACT 37 kw. COMPACT 37 kw high vacuum. COMPACT 45 kw high vacuum

Commercial. Central. Vacuum Systems. ... an unique range of possibilities!

minibrs Toll Free: Compact, powerful system is comfortable, easy to use and requires no containment

Dilute Phase Pressure Pneumatic Conveying Blower

INDUSTRIAL VACUUM CLEANING INNOVATION. Industrial vacuum cleaners

Safety vacuum drying oven for flammable solvents

CREATING A CLEANER ENVIRONMENT EAZIFLO FUME CAPTURE SYSTEM

AIRWASH Abrasive Recycling System

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

TECHNICAL CATALOGUE SILO VENTING DUST COLLECTORS. Manual No. FIL T.EN Issue: A Latest Update: January 2017 ORIGINAL INSTRUCTIONS IN ENGLISH

TECHNICAL DATA SHEET. InJet 388 CRD. STENCIL cleaning PUMPRINT cleaning CHAMBER.

PRODUCT GUIDE QUALITY EXTRACTION SOLUTIONS. Made in Norway

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

Excellent performance with low operating costs, Energy saving and environmentally friendly

Keller USA, Inc. Filtration of emissions. Capturing & extraction of process emissions. Return of clean air

RONDA 200. RONDA 200 when life is too short for hobby vacuum cleaners OTHER MACHINES FOR SIMILAR PURPOSES RONDA 20 RONDA 400

Mobile Dust Extractors

Blast system for PCB-restoration

HEROLIFT wear-resistant vacuum conveying technics

Hand Held Welding Guns

Safety vacuum cleaner with automatic filter cleaning system, 42 l, class L

VULKAN. Stationary Powder-Filling Machines

APPLICATIONS > KORUND

Adsorption Air Dryers

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

Instruction manual ASPIMAX 16

CLEACOM Engineered System Solutions. Established 24/7 technology for the separation of dust and fume during compounding processes

PolyRex polymer make-up unit, vacuum conveyor support Technical specification

Use. Worth noting. Key figures. Installation. linx industries chilled beams. the beam is mounted on a standard T-support.

WOLF VENTILATION SYSTEM PRICE LIST

Safety vacuum cleaner with automatic filter cleaning system, 30 l, class L

TECHNICAL DATA SHEET. InJet 388 CRD. STENCIL cleaning PUMPRINT cleaning CHAMBER.

Adsorption Dryers. AD 7 to 1300

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

BINDER Scientific Product Catalog

Halton Rex 600 Basic R6B - Active chilled beam

600A, Configurable. A powerful dust collector, for suction over long horizontal and vertical distance

BRAHM. Working together for a crystal-clean production line COLLECTOR SERIES

570A, Configurable. A powerful dust collector, excellent high vacuum for suction over long horizontal and vertical distances

Adsorption Dryers. AD 7 to 1300

REVO JOB INSTALLATION AREA. REVO Job SELECTION TABLE MAIN FEATURES OF THE PRODUCT PROFESSIONAL. CE marking. Automatic filter cleaning

DUST COLLECTORS DC 200 DC 230 E DC 250 CF DC 300 DC 350 CF DC 400 DC 450 CF DC 500 E DC 550 CF DC 600

Operating Instructions and Spare Parts List. ZR Monocyclone. Issued 09/01. ZR Monocyclone 9

Micro/Ultra Filtration System StamoClean CAT 430

FlexFilter EX A state of the art filter system to meet your current and future needs

Industrial vacuum cleaners powerful, versatile and easy to manage. Industrial Vacuum Cleaners

Industrial vacuum cleaner accessories. Heavy duty industrial machines

DESICCANT AIR DRYERS. BD + CD + CD series

Supplementary Operating Manual for Cutting mill combination

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Cartridge. SORB-AC Cartridge Pumps MK5 Series. Pump Body. Heater. Thermocouple. Flange. Electrical Connector

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

PERFORMANCE DATA Type Delivery Vacuum atm. Pressure Weight (l/min) (mbar abs) Press. (bar g) (kg)

PROCELL LABSYSTEM. direct pelletization. Glatt. Integrated Process Solutions.

2.2. Type 90. Safety cabinets for active storage of drums

TECHNICAL DATA SHEET NEW UPGRADED. InJet 888 CRD. FILTERS OF REFLOW OVENS, SOLDERING FRAMES cleaning PCBs cleaning CHAMBER.

Bedienungsanleitung. Ideas for dental technology. Made in Germany C

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

DUST AND FUME COLLECTOR FOR THERMAL CUTTING AND WELDING APPLICATIONS

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

COMBIFAB F Fan The flexible fan for dust extraction systems in all industries

Transcription:

Compact high vacuum unit that can be used as central vacuum cleaner for cleaning or hand tool connection. Compressed-air cleaned filter unit with timer control built together with side channel blower in sound enclosed cabinet and mounted on strong transport platform. Plug & Play model HFU-F is with built-in frequency converter and motor with thermal fuse. HFU/HFU-F: Air volume: Up to 1,100m³/h Vacuum: Up to 38,000Pa Filter area: 13m² Photo: High vacuum unit type HFU Photo: High vacuum unit type HFU-F Description filter unit type CJF Polluted air is led into unit through tangential inlet in raw air chamber top. Hereby downflow and preseparation by cyclone effect are ensured, which contributes to load reduction on the filter media itself. Air is filtered through vertical-placed filter cartridge with internal filter core, which optimizes cleaning effect. Timer-controlled filter cleaning by integrated compressed-air system with pressure tank and jet valve. The clean air is led out through ø125mm-connection (muff measurement) in cabinet top. Sound is damped by channel silencers on outlet integrated in unit. Dust is collected in dust container in unit bottom. Quicklock-adjustable dust container system suspended in ø400mm system flange. Description side channel blower type VBH Side channel blower is placed on vibration absorbers in sound enclosed cabinet. Vacuum limiter mounted on inlet. Guided cooling air by cooling ribs in cabinet. Optimized moveable vacuum cleaner solution with long operation times Side channel blower as vacuum pump and automatic filter cleaning by compressed-air enable continually operation. The compact construction on strong transport platform ensures that the vacuum cleaner unit can be moved from one production place to another and do not occupy much space. Moveable unit Built on a strong transport platform. Easy to move by hand pallet truck or fork lift by fork pockets. Easy connection 230V-electrical cable with plug and ø8mmcompressed-air hose are located on unit front. Plug & Play-unit HFU-F CEE-plug as well as start/stop-switch for side channel operation by frequency converter are placed on unit front (except HFU-F 20000). Frequency converter is read through front door window. All maintenance done through front door Maintenance incl. dust container emptying is done from unit front. Quicklock-adjustable dust container on 4 wheels ensures userfriendly dust container service. 4.HFU1

Filters: Filter cartridge ø325mm. Length: 660mm Filter control: Type Tec 33-timer control without automatic after-cleaning. 230V AC (constant) Should be connected with delayed disconnection in relation to fan stop to obtain after-cleaning Compressed-air: 5.5-6.0 bar dry compressed-air. Unit equipped with ø8mm pneumatic hose Differential pressure displayed in integrated manometer 1 -jet valve connected to central compressed-air tank in clean air chamber Filter change: Standard from clean air chamber top Filter material: Standard Material Used for G102 Polyester flake Dry not-static loaded or hygroscopic dust particles > 0.2µm Alternative G105 Cellulose/Polyester Welding/soldering G113 Polyester flake with PFPTcoating, Static-loaded or hygroscopic particles antistatic G115A Polyester flake with teflon membrane Finer dust sorts, e.g. cutting smoke from plasma, flame and laser cutting G116A Polyester flake with teflon membrane, antistatic Finer static-loaded dust sorts The filters meet demands for extraction degree for dust class M according to DIN EN 60335-2-69 Appendix AA (extraction degree > 99.9%). 4.HFU2

HIGH VACUUM UNIT Principle sketch for flow through high vacuum unit type HFU/HFU-F: Deflector for optimal air flow and filter life optimization. Internal filter core optimizes filter cartridge cleaning. Sound enclosed cabinet and integrated channel silencer on outlet reduce air noise. Matr.: V.Å. GRAM A/S Trumpf: Buk: Tegnet af: DM Godkendt af: Construction/surface: Skala: Dato f. godkendelse: High vacuum unit type HFU/HFU-F is constructed according to: Machine directive 2006/42/EU A4 EMC-directive 2004/108/EU Directive 97/23/EU about pressure equipment Low voltage directive 2006/95/EU Harmonized standards: EN 349, EN 4414, EN 12100, EN 60204-1, EN ISO 13857 Further standards: ISO 3746 Filter cabinet is made in 2mm black steel plate Surface powder enamelled RAL 5007/7011 structure HFU flow-tegning Dato: Tegn. nr.: 04.510 15 C C 4.HFU3

Further is available: Version in hot-galvanized, enamelled steel plates for outdoor mounting Filter replacement from unit side Filter control type BA, differential pressure control automatic after-cleaning Sack holder for 72L dust container ½ -water separator with manometer and pressure reducing valve Various high-pressure piping, fittings and coupling for fixed unit assembly Various sliding dampers and flap valves that possibly can be equipped with micro-switch for extraction start Various controls and system surveillances Various pin-point extractions, hoods, slot nozzles, plastic adapters for valves, hoses and cleaning equipment Explosion-protected/-reliefed version for installation in ATEX-zones (see ATEX data sheet) Various high-vacuum components and ABB-frequency converters are available. Flap valve type KV (left) and slot nozzle type VSPL with magnet - see product group 6. High vacuum unit type HFU/HFU-F is available in the sizes as stated in the forms below. Please, contact us for assistance in selecting the optimal unit taking into consideration air volume, dust type and volume, operation times etc. High vacuum unit type HFU: Type Order no. P start/end 2) [Pa] At 50Hz [kw / Amp] 3) Number filter cartridge G102 G105 Compressed air [L/min.] Dust container [L] HFU 5500 04 510 000 200/2000 5.5 / 12.0 1 1) 13 21 30 72 360 HFU 7500 04 511 000 200/2000 7.5 / 15.6 1 1) 13 21 30 72 370 HFU 9000 04 512 000 200/2000 9.0 / 20.8 1 1) 13 21 30 72 375 HFU 13000 04 513 000 200/2000 13.0 / 27.0 1 1) 13 21 30 72 380 HFU 20000 04 514 000 200/2000 20.0 / 38.6 1 1) 13 21 30 72 395 Weight [kg] High vacuum unit type HFU-F with built-in frequency converter: Type Order no. P start/end 2) [Pa] At 60Hz [kw / Amp] 3) Frequency converter [kw] G102 G105 1) Filter cartridge ø325 x 660mm/ø13.5mm, 13m², G102 (08 128 100) as well as delivered with 1 piece jet valve 2) Pressure drop stated over filter cartridge 3) Motor voltage: 3 x 400/690V Number filter cartridge Compressed air [L/min.] Dust container [L] HFU-F 5500 04 510 300 200/2000 6.3 / 15.3 7.5 1 1) 13 21 30 72 380 HFU-F 7500 04 511 300 200/2000 8.6 / 19.6 11.0 1 1) 13 21 30 72 390 HFU-F 9000 04 512 300 200/2000 11.0 / 21.4 11.0 1 1) 13 21 30 72 395 HFU-F 13000 04 513 300 200/2000 15.0 / 30.0 15.0 1 1) 13 21 30 72 400 HFU-F 20000 04 514 300 200/2000 23.0 / 44.0 30.0 1 1) 13 21 30 72 415 Weight [kg] 4.HFU4

Side channel blower for high vacuum unit type HFU (50Hz): 2000 534 5 4000 Ringkammerblæser Side channel blower (vakuum) (vacuum)- - 50Hz 510 5 6000 m³/h 480 5 1200 8000 462 5,5 kw 5 1000 9,0 kw 7,5 kw 0000 435 5 2000 800 20,0 kw 13,0 kw 408 5 4000 600 20,0 kw 384 5 6000 400 354 4 8000 200 318 4 00000 285 4 2000 0 4000 8000 12000 16000 20000 24000 28000 32000 246 Pa 4 Side channel blower for high vacuum unit type HFU-F (60Hz): 32000 34000 Ringkammerblæser Side channel blower (vakuum) (vacuum) - 60Hz - 36000 m³/h 38000 1600 1400 11,0 kw 1200 15,0 kw 1000 23,0 kw 800 600 400 200 0 0 4000 8000 12000 16000 20000 24000 28000 32000 36000 Pa 6,3 kw 8,6 kw 23,0 kw 4.HFU5