PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

Similar documents
USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

80 Watts FLANGE FINISH

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

1" Regress Trim DELIVERED PERFORMANCE - Downlight

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION FLANGE FINISH

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED 2.1 PROJECT INFORMATION

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

PROJECT INFORMATION PROJECT DATE TYPE

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

OPTIONAL LENS 2 FLANGE FINISH

True Zero Conceal - Z3SA-C 3 Square Adjustable

PROJECT INFORMATION PROJECT

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

DATE TYPE 40 DELIVERED PERFORMANCE

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

SliverLED Round Downlight, 1 Regress SR11

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

NanoLED NXT Cylinder LNRP3 Surface

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

SliverLED Round Adjustable, Wet Location SR21W

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

BeveLED Cylinder LBRP6 Surface

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

Field changeable between Trimmed / Trimless / Millwork

Field changeable between Trimmed / Trimless / Millwork

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

BeveLED Cylinder LBRP6 Pendant

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini Trimless Acoustical - B3RDP

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

BeveLED Mini - B3RD 3 Round Downlight

BeveLED Mini - B3SD 3 Square Downlight

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

PROJECT DATE FLANGE FINISH

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

BeveLED Mini - B3RA 3 Round Adjustable

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Grüv Flare Regressed. Recessed Linear LED

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Micro Wall Wash Trimless - MWL

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Square Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Round Adjustable C3

Evoke Square Adjustable HP

Grüv Flare Regressed. Recessed Linear LED

Essenza. Square Downlights

Evoke Square Downlight

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

Essenza. Round Downlights

Classix 6" 6" Round Adjustable C3M

IHOL-6DR / IRD600 6 Gravity LED Downlight

Evoke Square Adjustable HP

Evoke Square Adjustable C3M

Classix 6" 6" Round Adjustable C3

IHOL-4DR / IRD400 4 Gravity LED Downlight

Evoke Round Downlight

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Classix 6" 6" Round Lens Wall Wash

Hornet HP. Semi-Recessed 4-Light Square Multiple

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Hornet HP. Round Glass Downlight

Velato. Recessed Slot Adjustable Multiples

Performance Chart Electrical Data

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Transcription:

DOWNLIGHT Beve2.1 Trimless 3311 PROJECT INFORMATION PROJECT DATE TYPE 1" Regress Beve 2.1 Recessed Downlight - Beve 2.1 is the most complete recessed downlight product family available from, now with more Beve trim finishes, classic white color temperatures, innovative housing styles, and dimming driver options than before. With industry-leading performance, Beve 2.1 can provide a solution for any project - commercial, corporate and residential installations. DELIVE PERFORMANCE Beve 2.1 1 REGRESS DOWNLIGHT Color Rendering Index Lumens per Watt Source Lumens Delivered Lumens Color Consistency 9 Watts 90+ 80+ HIGH 100 74 1150 900 850 675 12 Watts 80+ 93 1300 1125 16 Watts 90+ HIGH 73 1025 875 24 Watts 33 Watts 90+ 90+ 80+ HIGH 80+ HIGH 93 72 86 67 1725 1350 2400 1875 1475 1150 2050 1600 2-Step MacAdam Ellipse 36 Watts 1" Regress 90+ 90+ 80+ HIGH 80+ HIGH 77 62 100 78 3025 2350 4150 3250 2600 2025 3450 2700 1" Regress Bevel Finish Performance based on 3000K CCT MULTIPLIER 2200K Color Rendering Index Multiplier for Lumen Output 2700K 3000K 80+ 80+ 90+ HIGH 0.72 0.94 0.78 3500K 4000K 80+ 90+ HIGH 80+ 80+ 1.00.78 1.00 1.06 31 2" x 31 2" 41 2" x 41 2" 90+ is not available for 2200K, 3500K, or 4000K HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 3311W - B1- S - 10 - LSLD4-9012 - C3-27KS - 50 - NC - 277V - DIML2 - CB27 TRIM ORDERING INFORMATION TRIM 3311 3311 Square Trimless Downlight 1 Regress BEVEL STYLE OPTION Wet location 1 Integral Emergency Test Switch 2 W EML LENS B1 BEVEL FINISH B1 1" Regress Bevel, Painted Die Cast S Solite (provided standard) F Frosted 10 13 21 28 RAL S Solite (provided standard) F Frosted (Leave blank for AB1 and AC1 Bevel Styles) 1 Wet location, use with B1 trims only. 2 AB1 1" Regress Bevel, Black Anodized Finish AC1 1" Regress Bevel, Clear Matte Anodized Finish See table on page 2 HOUSING ORDERING INFORMATION HOUSING CODE WATTAGE ENGINE CODE LSLD4 LSLD4 9009 9012 9016 9024 9033 9036 9W 12W 16W 24W 33W 36W COLOR REFLECTOR C3 E1 22KS 27KS 30KS 35KS 40KS 27KH 30KH 2200K, 80+ 3 2700K, 80+ 3000K, 80+ 3500K, 80+ 4000K, 80+ 2700K, 90+ 3000K, 90+ HOUSING TYPE 120V 277V 120V See emergency solutions chart for EM options with these housings 347V 3 Not available with E1 light engine 4 Not available with E1 light engine DIMMING OPTIONS FT Flat Housing New Construction FTIC Flat Housing IC-Rated/Airtight (up to 16W maximum) NCSM1 New Construction Narrow Width 5/8 to 1-1/4 ceiling max NCSM2 New Construction Narrow Width 1-1/4 to 2-1/4 ceiling max NC New Construction, all in one CP Chicago Plenum IC Insulation-Contact Rated / Airtight 4 25 25 beam 50 50 beam 90 90 beam See performance chart for precise lumen information. 2 Step MacAdam ellipse is standard for all SELECT ONE VOLTAGE White Statuary Bronze Black Metalized Grey Custom Color (specify RAL #) 5 6 7 8 ACCESSORIES For use with 120V or 277V CB27 27" C-Channel Bars DIML2 0-10V dim, 10% CB52 52" C-Channel Bars (provided standard) EML Emergency battery 9 DIML4 A 3-wire/ECO, 1% EMLW Emergency battery, DIML4E 5 ECO, 5% 5 wet location 9 DIML4H H ECO, 1% Fade 5 ML Millwork housing 10 =Specify Color DIML6A Eldo 0-10V, 0.1%, (10, 13, 21, 28, RAL) logarithmic / controls Millwork not wet DIML6B Eldo 0-10V Linear, 0.1%, listed linear controls DIML6E Eldo 0-10V, 1%, logarithmic/ controls DIML6F Eldo 0-10V, 1%, linear controls DIML7 Eldo DALI, 0.1% DIML8 Eldo DM, 0.1% 6, 7 For use with 120V only DIML3 A 2-wire, 1% 120V only DIML19 Phase 2-wire dimming, 1% 120V only 5, 6, 8 For use with 347V only 9 See emergency solutions chart DIML15 0-10V dim, 1%, 347 only for more details on EM options. N/A with 9W N/A with 33W N/A with FT or FTIC housing N/A with E1 light engine Not available with 347V 10 ML not for use with NCSM1 housings 2015., LLC. Revised 12/19/2017

DOWNLIGHT Beve2.1 Trimless 3311 TRIM INFORMATION 3311 Emergency Solutions EM Integral Remote Inverter Housing SERVICE Test Switch Test Switch By Others FT, FTIC N/A NCSM* Above ceiling access required NC Through aperture NC Wet Location Through aperture CP N/A IC N/A 1" Regress EM fixtures that are provided with an integral test switch are shipped with a hole in the glass lens for access. Refer to EMERGENCY SOLUTIONS chart to find out which fixtures have an integral test switch. 31 2" x 31 2" 41 2" x 41 2" * NCSM + DIML8 cannot be offered with EM. 347V cannot be offered with EM. HOUSING INFORMATION New Construction Universal Style Housing - NC New Construction Flat Housing - FT New Construction Flat Housing IC-Rated /Airtight- FTIC (up to 16W maximum) 33/8-3" 73/8" 33/8-3" /8-1" 5 /8-1" 5 Always 4" /8"-1" 5 7" Always 4" 71/4 71/4 13" 81/4 81/4 185/8" (Plan View) 16" (Plan View) 16" (Plan View) 221/8" (Plan View) 19" (Plan View) 19" (Plan View) 83/8" 83/8" New Construction - Narrow Width - NCSM 53/4" 43/4" Shown with EM option 81/4" " NCSM1: 5/8" - 11/4" NCSM2:11/4" - 21/4" Chicago Plenum (24W and less) - CP IC / Airtight (24W and less) - IC 19" (Plan View) 19" (Plan View) 22(Plan View) 22(Plan View) Chicago Plenum (33W and 36W) - CP IC / Airtight (33W) - IC (Not available with E1 light engine) 73/8" 81/2" /8"-1" 5 7" 5 7" 13" 13" 185/8" (Plan View) 185/8" (Plan View) 221/8" (Plan View) 221/8" (Plan View) /8"-1" 2015., LLC. Revised 12/19/2017

DOWNLIGHT Beve2.1 Trimless 3311 SPECIFICATIONS TRIM: 4-1/2" square aperture with a 1" regressed bevel, retained by four mounting clips. Die cast aluminum bevel is self-flanged and is available in white, statuary bronze, black, and metalized grey finishes. Also available in black anodized or clear matte anodized bevel. Custom colors available (provide RAL#). TRIM LENS: Trim is shipped with integral solite lens standard; frosted lens available as an option. REFLECTOR: Interchangeable precision injection molded specular polycarbonate reflector optimized for 25, 50 or 90 beam distribution. FIELD REPLACEABLE LIGHT ENGINE: Available in 6 lumen packages. Engine is field replaceable through the aperture without tools. See performance chart for precise lumen output information. COLOR: Beve 2.1 is available in 5 color temperatures (2200K, 2700K, 3000K, 3500K, 4000K). All color options are tightly binned for fixture-to-fixture color consistency within a 2-Step MacAdam Ellipse. 80+ color rendering index provided standard. 90+ available for 2700K and 3000K CCTs. 2200K is not available with E1 light engine. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum life. Ambient temperatures at fixture location should not exceed 40 C during normal operation. DIMMING OPTIONS: Multiple dimming drivers available. See compatibility chart attached. Some on-time delay may be experienced depending on control system used. Note: DIML6A and 6E logarithmic control are intended for use with control systems; DIML6B and DIML6F linear control are intended for use with non- controls. DIML15 and DIML6 dimming drivers source 2mA. EMERGENCY: Fixtures provided with an integral test switch are provided with a hole in the glass lens as per the drawing above. Fixtures provided with a remote test switch are provided with a 24 lead length for location of the test switch. Fixtures that have no EM option may be connected to an inverter (by others) for emergency lighting. SPECIAL NOTE FOR NCSM HOUSING: DIML8 cannot be combined with EM options in NCSM housing See emergency solutions chart for more information on EM test switches and servicing. with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. FTIC housing is ICrated up to 16W maximum. IC-rated housings for use with 9W, 12W, and 16W light engines only are rated for direct contact with spray foam insulation of R-42 or less. IC-rated housing is not available with E1 light engine. When using DIML8, NCSM housing can NOT be used with thru-branch circuit wiring. LISTINGS: Dry/Damp. Wet location option available with B1 trim only. Millwork Dry/Damp only. NRTL/ CSA-US tested to UL standards. IBEW union made. Energy Star Qualified under Luminaires Specification V2.0. See Energy Star website for exact model #s included in the listing. The following options are not Energy Star qualified: 22KS, 27KH, and 30KH light engines; E1 light engines; B-13, B-21, and AB trim styles; Frosted lens and EM options. MOUNTING: Butterfly brackets and adjustable nailer bars CEC/Title 24 Compliant up to 16W maximum. See with integral nails provided. Nailer bars are extendible from CEC website for exact models included. 14" to 24" centers. C-channel bars are optionally available. MAIMUM CEILING THICKNESS: As per drawings above. Millwork option is for 2-1/4 max. thickness wood with NCSM2 housing and for 1 max thickness wood with all other housings. Millwork option is not available with NCSM1 housing. CEILING CUT OUT: Millwork: 4-13/16 x 4-13/16 All others: 5-1/2 x 5-1/2 WARRANTY: 5 years Not for use in corrosive environment. Use of pressure washer voids warranty. For interior use only. Not for use with acoustical ceilings. Trimless for drywall installation only. Millwork option for non-spackle installations. HOUSING: All-Ways Square (covered by US Pat. No: US FIELD REPLACEABLE : 0-10V, 100%-10% solid state 7,832,889) housing allows alignment of square aperture (up PHOTOMETRICS: Consult factory or website for IES electronic constant current driver with a high power factor to 20 rotation) after housing installation and prior to finish files. Tested in accordance with IESNA LM79-2008. provided standard and sources 2mA. Specify 120V or 277V. ceiling installation. Fabricated of 20 ga. galvanized steel Driver complies with IEEE C62.41 surge protection. 2015., LLC. Revised 12/19/2017

DOWNLIGHT Beve2.1 Trimless 3311 DELIVE PERFORMANCE 3110 / 3311 16W 30KS 25 3110 / 3311 33W 30KS 25 2015., LLC. Revised 12/19/2017

DOWNLIGHT Beve2.1 Trimless 3311 DELIVE PERFORMANCE 3110 / 3311 16W 30KS 50 3110 / 3311 33W 30KS 50 2015., LLC. Revised 12/19/2017

DOWNLIGHT Beve2.1 Trimless 3311 DELIVE PERFORMANCE 3110 / 3311 16W 30KS 90 3110 / 3311 33W 30KS 90 2015., LLC. Revised 12/19/2017

DIMMING COMPATIBILITY D2 / DIML2 DIMMING WIRING SCHEMES: D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) 120V / 277V Leviton Lightolier (Philips) D2 / DIML2 Dimmer Compatibility Chart Part Number ilux dimmer expansion module DIN Rail dimmer DIN Rail analog output module 8 Channel dimmer module 8 Channel dimmer module IllumaTech dimmer Vega Diva CLS-EP-DIMFLV DIN-4DIMFLV4 DIN-A08 GL-DIMFLV8 GLP-DIMFLV8 IP710-DL V2000FAMU DVT Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) GRAY 0-10V (+) NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING COMPATIBILITY D3 / DIML3 DIMMING WIRING SCHEMES: D3 / DIML3 : Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart 120V Only ETC ETC Part Number Sensor+ Cabinet Unison DRd Cabinet Maestro Wireless 600W dimmer Maestro Wireless 1000W dimmer HomeWorks QS adaptive dimmer HomeWorks QS 600W dimmer HomeWorks QS 1000 W dimmer Caseta Wireless Pro 1000W dimmer Stanza dimmer RadioRA 2 adaptive dimmer RadioRA 2 1000 W dimmer myroom DIN power module HomeWorks QS wallbox power module Homeworks DIN power module HomeWorks wallbox power module GRAFIK Eye QS control unit GRAFIK Eye 3000 control unit RPM-4U module RPM-4A module GP dimming panels Ariadni CL 250W dimmer Diva CL 250W dimmer Grafik T CL or RF CL dimmer Nova T CL 250W dimmer ELV10 ELV10 MRF2-6ND-120MRF2-10ND-120HQRD-6NAHQRD-6NDHQRD-10NDPD-10NDSZ-6NDRRD-6NARRD-10NDMQSE-4A1-D HQRJ-WPM-6D-120LQSE-4A1-D HWI-WPM-6D-120 QSGR-, QSGRJGR-3100-, GR-3500HW-RPM-4U-120, LP-RPM-4U-120 HW-RPM-4A-120, LP-RPM-4A-120 Various AYCL-253PDVCL-253P-, DVSCCL-253PGT-250M-, GTJ-250MNTCL-250-100%-1% 100%-1% 100%-1% 100%-1% Qty Fixtures Per Dimmer* Fixture Wattage 39W and Less 40W - 80W 1 26 1 26 18 14 16 18 14 18 14 16 16 18 14 18 14 16 13 16 13 1 26 16 13 1 26 1 26 1 26 1 26 1 26 1 26 18 14 18 14 18 14 1 10 15 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE GROUND ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING COMPATIBILITY D4 / DIML4 DIMMING WIRING SCHEMES: D4 / DIML4 : Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) 120V Only ETC ETC 277V Only ETC ETC D4 / DIML4 3-Wire Dimmer Compatibility Chart Part Number Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Vareo Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10NTF-103PNF-10NF-103PVF-10SF-10P-, SF-103PDVF-103P-, DVSCF-103PAYF-103PVTF-6AMAF-6AM-, MSCF-6AMMRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-120, PHPM-3F-DV Various Sensor+ Cabinet Unison DRd Cabinet Nova T Nova T Nova Nova Skylark Diva Ariadni Vierti Maestro Maestro Wireless RadioRA 2 HomeWorks QS Interfaces GP Dimming Panels D20 Dimming module D20F Dimming module NTF-10-277NTF-103P-277NF-10-277NF-103P-277SF-12P-277-, SF-12P-277-3 DVF-103P-277-, DVSCF-103P-277AYF-103P-277VTF-6AMAF-6AM-277-, MSCF-6AM-277MRF2-F6AN-DVRRD-F6AN-DVHQRD-F6AN-DV PHPM-3F-DV Various Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 153 126 153 126 141 1 20 120 1 10 141 1 20 120 1 10 120 1 10 120 1 10 120 1 10 120 1 10 115 17 115 17 115 17 115 17 115 17 141 1 20 141 1 20 40W and Less 41W - 80W 153 126 153 126 144 1 22 133 144 1 22 133 133 133 144 1 22 133 120 1 10 133 133 133 188 1 44 188 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING COMPATIBILITY D4 / DIML4 Continued DIMMING WIRING SCHEMES: D4 / DIML4 : Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3 WIRE PHASE DIMMING DIMMER: 3 WIRE PHASE CAP UNUSED ECOSYS WIRES DIMMED HOT GRAY ORANGE GROUND D4 / DIML4 : Hi-Lume A-Series Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to 120V / 277V D4 / DIML4 EcoSystem Dimmer Compatibility Chart Part Number PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DB QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 132 164 1 32 164 1 32 164 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 E1 WALL CONTROL CAP UN-USED ORANGE WIRE GRAY ORANGE 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING COMPATIBILITY D4E / DIML4E and D4H /DIML4H DIMMING WIRING SCHEMES: D4E / DIML4E : 5 Series EcoSystem Driver / Dimming Driver Wiring (Dims down to 5%) 120V / 277V D4E / DIML4E EcoSystem Dimmer Compatibility Chart Part Number PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DB QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various 100%5% 100%5% 100%5% 100%5% Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 132 164 1 32 164 1 32 164 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4H / DIML4H : H Series EcoSystem Driver with Fade to Black (dims down to 1%) 120V / 277V D4H / DIML4H EcoSystem Dimmer Compatibility Chart Part Number PowPak dimming module Energi Savr Node GRAFIK Eye QS (120V ONLY) Quantum RMJ-ECO32-DB QSN-1ECO-S, QSN-2ECO-S QSGRJ-_E, QSGR-_E Various Qty Fixtures Per Control* Fixture Wattage 39W and Less 40W - 80W 132 164 1 32 164 1 32 164 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D4E / DIML4E and D4H / DIML 4H EcoSystem CONTROLS ECOSYS BUS E2 E1 E2 E1 WALL CONTROL GRAY 2016., LLC. I2-264-4EH Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart 120V & 277V Sensor Switch enlighted Part Number Diva Nova T Energi Savr Node GP Dimming Panels Interfaces nio Control Unit DVTV/NFTV with PP-20 NTFTV with PP-20 QSN-4T16-S TVM2 Module GR-TVI w/ GR3503 nio EZ CU-3E-1R DIML6A 6E 99% - 0.1% 1% 99% - 0.1% 1% 99% - 0.1% 1% Qty Fixtures Per Dimmer* Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g.,, non- and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart 120V & 277V Bush-Jaeger Jung Leviton Lightolier (Philips) Merten Pass & Seymour Watt Stopper Synergy ABB enlighted Part Number Electronic potentiometer Electronic potentiometer Iluma Tech dimmer Momentum (120V ONLY) Electronic potentiometer Titan Miro Wallbox Dimmers i-bus Modules Green Light Green Light Power Pack DIN Rail Analog Output Module DIN Rail 0-10V Fluorescent Dimmer ilux 0-10V Dimmer Expansion Module Control Unit 2112U-101 240-10 IP710-DL ZP600FAM120 5729 CD4FB-W DCLV1 ISD BC SD/S 2.16.1 GL-DIMFLV8, GLP-DIMFLV8 GLPAC-DIMFLV4-, GLPAC-DIMFLV8GLPP-DIMFLVE-PM, GLPP-1DIMFLV2E-PM, GLPP-1DIMFLV3E-PM DIN-A08 DIN-4DIMFLV4 CLS-EP-DIMFLV CU-3E-1R DIML6B 6F Qty Fixtures Per Dimmer* Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER D6 / DIML6 0-10V DIMMING (NO RELAY) DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) GROUND CLASS 2 CONTROL WIRES DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) GRAY 0-10V (+) RELAY DIML6A, 6B 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING COMPATIBILITY D7 / DIML7 and D7E DIMMING WIRING SCHEMES: D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING COMPATIBILITY D8 / DIML8 and D8E DIMMING WIRING SCHEMES: D8 / DIML8 and D8E Dimming Driver Wiring D8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = Eldo POWERdrive DM control dims from 100% to 0.1% D8E = Eldo POWERdrive DM control dims from 100% to 1% DM BUS - LR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DM512 data reliably over long distances. NOTE: DM link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. D8 / DIML8 / D8E DM CONTROLS DM BUS - LR CABLE OR SHIELDED DATA CABLE SHIELD DM (-) DM (+) 5 PIN LR JACKS STANDARD 8 BIT DM 512 CONTROLLER BARE 2016., LLC. I2-264-8 Revised 08/14/2017

DIMMING COMPATIBILITY D15 / DIML15 DIMMING WIRING SCHEMES: D15 / DIML15 : 0-10V, 347V Dimming Driver Wiring (Dims down to 1%) 347V Only 347 Acuity Douglas Hubbell Leviton Leviton D15 / DIML15 Dimmer Compatibility Chart Synergy ISD-BC WPN-5721, WPN-5822 Light Hawk2 LHD-IRS3-N347-xx Illumatech IP710-DLZ with 347V relay Centura Fluorescent Control System Nova NFT* dimmer plus 347V relay Diva DVT* dimmer plus 347V relay Qty Fixtures Per Dimmer* Use source current per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D15 / DIML15 0-10V DIMMING W/RELAY TO SWITCH POWER DIMMER: 0-10V 0-10V (-) GRAY 0-10V (+) NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIML2 0-10V DIMMING (NO RELAY) DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) GRAY 0-10V (+) GROUND NOTE: Quickship fixtures are shipped prewired for 0-10V dimming controls. If switched, nondimming operation is desired, cap off purple and gray wires separately at installation. Do NOT cap purple and gray wires together. 2016., LLC. I2-264-15 Revised 03/22/2017

DIMMING COMPATIBILITY D19 / DIML19 DIMMING WIRING SCHEMES: D19 / DIML19 : Hatch TC series or equivalent - Forward and Reverse Phase Dimming Driver. Dims down to 1% contingent upon dimmer specification and load. 120V only. D19 / DIML19 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE GROUND ONLY FOR SWITCHES WITH D19 / DIML19 Dimmer Compatibility Chart 120V ONLY Forward Phase / TRIAC Dimming Qty Fixtures Per Dimmer Leviton IPL06-10Z Use fixture wattage per 6613-xxx fixture specification S-600P sheet to determine S-603P number of fixtures D600P per dimmer. Max number D603P of fixtures is limited by DVSC-603P dimmer load rating. CT-600P CT-603P 120V ONLY Reverse Phase / ELV Dimming Leviton 6615 IPE04-xxx NTEL300 NTEL600 SEL300P SEL303P DVEL300P DVEL303P Qty Fixtures Per Dimmer Use fixture wattage per fixture specification sheet to determine number of fixtures per dimmer. Max number of fixtures is limited by dimmer load rating. 2016., LLC. I2-264-19 Revised 03/22/2017