RAINSHOWER SMARTCONTROL DESIGN + ENGINEERING GROHE GERMANY

Similar documents
RAINSHOWER SYSTEM SMARTCONTROL 360 DUO MODEL # Product Specifications. Product description

Grohtherm Grohtherm 1000

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /06.12

GROHTHERM 3000 COSMOPOLITAN DESIGN + ENGINEERING GROHE GERMANY /ÄM / GB

Grohtherm Grohtherm 1000

Grohtherm 1000 Cosmopolitan. Grohtherm 1000 Cosmopolitan. Design + Engineering GROHE Germany /ÄM /01.14

Eurodisc SE. Eurodisc SE

Eurosmart Cosmopolitan. Eurosmart Cosmopolitan. Design & Quality Engineering GROHE Germany /ÄM /10.11

Eurosmart FIN EST SLO RUS UAE Eurosmart Design & Quality Engineering GROHE Germany

Grohtherm Wireless! Installation Instructions Pumped High Pressure

Grohtherm Wireless! Installation Instructions Pumped

Linear FIN EST SLO RUS UAE Lineare Design & Quality Engineering GROHE Germany

Vitalio System. Design + Engineering GROHE Germany /ÄM /04.14

EUROSMART DESIGN + ENGINEERING GROHE GERMANY /ÄM /

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Pressure Balanced Thermostatic Mixers

FM Mattsson. Pressure Balancing Thermostatic Mixing Valves FEATURES. - Different on the inside

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Installation, Operating and Maintenance Guide

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

book : T95548.FM Seite 1 Montag, Oktober 11, :01 AM

Deluge Shower Mixing Valve 10045CP

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Telo Shower Mixing Valve TL10016CP

Kiko Bath Shower Mixing Valve KK90015CP

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

Mio Concealed Shower Mixing Valve MI40010CP

Avensys Avensys FIN EST SLO RUS UAE

Plus Bath Shower Mixing Valve CP and PL30020CP

Inta City Concealed Shower Mixing Valve CT80010CP

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

20mm Thermostatic Mixing Valve for use in Australia and New Zealand

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Intatherm Safe Touch Basin Tap IT1008CP

Inta City Shower Mixing Valve CT20010CP

Avensys Avensys FIN EST SLO RUS UAE

s y ens Av Avensys FIN EST RUS SLO RUS UAE

The New Caroma TMV20

Enzo Concealed Shower Mixing Valve

Deluge Concealed Shower Mixing Valve DL40010CP

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Kiko Concealed Shower Mixing Valve KK80010CP

Rada Thermostatic Mixing Valves

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

100% ENJOYMENT. GUARANTEED.

Puro Mini Dual Control Shower Mixer PU90010CP

methven SHOWERS & TAPWARE

FOR INSTALLING AND USING

grohe New TempesTa out of 10 prefer NEW 3 DESIGN STYLES UP TO 4 SPRAY PATTERNS NEW TEMPESTA Cosmopolitan NEW TEMPESTA NEW TEMPESTA Rustic

ELINA concentric exposed thermostatic mixer valve

Herz York Direct Heat Interface Unit

ENERGY SA ERS ELECTRIC AND DIGITAL CONTROLLED WATER HEATERS. The most advanced way to make hot water

These instructions are to be left with the user

Thermostatic mixing valves with replaceable cartridge for centralized systems

CROMO manual mixer shower

Nostracernium detore. Health and Care

THAMES mini exposed sequential thermostatic mixer shower Installation and operating instructions

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

Installation plan. Washer disinfector. en AU, NZ PG 8583 CD. M. Nr

These instructions are to be left with the user

Empty unit Cover Water Total weight 15 kg 8 kg 10 kg 33 kg

Enzo Safe Touch Thermostatic Shower EZ20011CP & EZ20012CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP

AQUAFIT - the innovative single-lever mixer for safety and hygiene

Hand Held Welding Guns

PREMIUM KITCHEN MIXER TAP. PREMIUM KITCHEN MIXER TAP Assembly, operating and safety instructions IAN

EXPOSED VALVES Apollo 139 Kubic 163 Neptune 169. Medium Pressure 0.5 BAR Thermostatic Control

Friwa Compact. Operating instructions EN

Cube Triplel Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

GROHE Affordable Luxury. With superior quality, design and technology

The Safety Valve Specialist Thermostatic Shower Controls

EXPOSED VALVES Apollo 139 Kubic 163 Neptune 169. Medium Pressure 0.5 BAR Thermostatic Control.

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

Francis Pegler Memento Single Sequential Exposed Thermostatic Shower

VALONA Thermostatic mixer shower with diverter

GROHE.CO.IN NEW GROHE EUROSMART FOR BATHROOM, KITCHEN AND COMMERCIAL

EcoStyle Dual Concealed Thermostatic Shower. Telephone Product Specification. Cleaning

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

aquablend thermostatic mixing valves

Infra Red Thermostatic Wall Mixer

SENATA thermostatic bar mixer shower Installation and operating instructions

GROHTHERM 1000 COSMO UNIVERSAL PRESSURE PRODUCT LAUNCH UPDATE

INSTALLATION INSTRUCTIONS

Shower Panels with a Thermostatic Sequential Control

FREQUENTLY ASKED QUESTIONS

Airfield Industrial Estate Hixon Staffordshire ST18 0PF

Technical Specifications: Your product has a high quality finish and should be treated with care to preserve the visible surfaces.

Alpha CombiMax 350 and 600

Rada Thermostatic Mixing Valves

Automatic Temperature Controller (ATC)

Thermostatic Bar Valve

PRODUCT SPECIFICATION GUIDE

RAISING THE BAR PROUDLY AUSTRALIAN MADE CUTTING EDGE INNOVATION DESIGNED WITH EXCELLENT SCALD PROTECTION BUILT IN SAFETY FEATURES.

Air Cooler Industry OK-ELC 0-7

INSTALLATION MANUAL. Ecoline Geo RI HP PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION

THAMES Thermostatic vertical mixer shower Installation and operating instructions

Thermostatic mixing valves with interchangeable cartridges

All Valve Industries. General Product Overview. Distributed by All Valve Industries. Ph: Fax:

Transcription:

RANSHOWER SMARTCONTROL DESGN + ENGNEERNG GROHE GERMANY 99.1029.031/ÄM 242625/018 www.grohe.com 26 537

*19 001 *49 059

1 2 90 36mm 37-42 min. 1200 150 5x 5x 3 41mm

4 5 4mm 6 7 Ø10 *48 349-150mm *48 350 +150mm 970 970 8a 8b 9 *26 385 (+8) 9-12 17-20 *26 385 *48 349-150mm T25 T25 *48 350 +150mm 20mm

10 11 *48 349 X-150mm *48 350 X+150mm 5. 4. 4. 12 13 1750 90

14a 14b 35 ~ 14c 35 1 2 38 C

1 *19 001 38 C 36mm *49 059

1 2

4. 5. 4mm 6. 7. 17mm 17mm 90 48 348

Safety notes Protection against scalding t is recommended that near points of discharge with particular sensitivity to the outlet temperature (hospitals, schools, nursing and retirement homes) thermostatic devices should be installed which can limit the water temperature to 43 C. This product is limited at 43 C. t is generally recommended that the temperature of showersystems should not exceed 38 C in nurseries and specific areas of care centres. Use Grohtherm Special thermostats with special handle to facilitate thermal disinfection and appropriate safety end stop. Applicable standards (e. g. EN 806-2) and technical regulations for drinking water must be observed. Application Thermostat mixers are designed for hot water supply via pressurised storage heaters and, utilised in this way, provide the best temperature accuracy. With sufficient power output (from 18 kw or 250 kcal/min), electric or gas instantaneous heaters are also suitable. Thermostats cannot be used in conjunction with non-pressurised storage heaters (displacement water heaters). All thermostats are adjusted in the factory at a flow pressure of 300 kpa on both sides. Should temperature deviations occur on account of special installation conditions, the thermostat must be adapted to local conditions (see Adjusting). Specifications Flow pressure min. 50 kpa - recommended 100-500 kpa Operating pressure max. 1000 kpa Test pressure 1600 kpa f static pressure is greater than 500 kpa, fit pressure reducer. Avoid major pressure differences between hot and cold water supply. Flow rate at 300 kpa flow pressure (cold water): head shower approx. 11 L/min hand shower approx. 8,5 L/min Flow rate at 300 kpa flow pressure (mixed water): head shower approx. 14 L/min hand shower approx. 9 L/min This product is has been tested and certified in accordance AS 4034 Thermostatic Mixing Valve Standard, and the AS/NZS 3662 standard for shower products. Note: Due to different pressure and flow capabilities at some properties, the flow rate of this product may fluctuate between the hot and cold positions. The maximum dynamic hot and cold flow ratio of this product is 1:5. E.g. f the cold water pressure is 500 kpa, the hot water pressure must be no less than 100 kpa. Temperature: Hot water inlet (maximum) 70 C Recommended (energy saving) 60 C Thermal disinfection possible Safety stop 38 C Hot water temperature at supply connection min. 2 C higher than mixed water temperature Minimum flow rate = 5 L/min nstallation Flush piping system prior and after installation of fitting thoroughly (Consider EN 806)! This product must be installed in conformance with local codes e.g. AS/NZS 3500 series of standard! nstallation of the shower rail When installing e.g. on plasterboard walls (not solid walls) it must be assured that an appropriate reinforcement is in place to ensure sufficient strength. Reversed connection (hot on right - cold on left). Replace thermostatic compact cartridge, see Replacement parts, Prod. no.: 47 175 (1/2 ). Operation The safety stop limits the temperature range to 38 C. The 38 C limit can be overridden by pressing the button, see Fig. [1]. Shut-off valves, see Fig. [2]. Adjusting Temperature adjustment Prevention of frost damage When the domestic water system is drained, thermostat mixers must be drained separately, since non-return valves are installed in the hot and cold water connections. For this purpose, the mixer must be removed from the wall. Maintenance nspect and clean all parts, replace if necessary and lubricate with special valve grease. Shut off the hot and cold water supply. Thermostatic compact cartridge Readjustment is necessary after every maintenance operation on the thermostatic compact cartridge (see Adjusting). Shut-off valves Readjustment is necessary after every maintenance operation on the shut-off valves, see Fig. [2]. Showers The function of the SpeedClean nozzles is guaranteed for a period of five years. Thanks to the SpeedClean nozzles, which must be regularly cleaned, limescale deposits on the rose can be removed by simply rubbing with the fingers. Replacement parts ( * = special accessories). Care For directions on care, refer to the accompanying Care nstructions. AUS Reece Australia Pty Ltd 118 Burwood Hwy Burwood VC 3125 Tel.: +61 3 9274 0000 Email: admin@reece.com.au NZ Robertson 25 Vestey Drive Mt Wellington, Auckland Tel.: +64 9 5730490 Email: sales@robertson.co.nz