ACNF Series Ceiling-Mount Air Handlers 1½ to 2½ Tons

Similar documents
ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

ASUF Series. Multi-Position, Multi-Speed ECM-Based Air Handler 1½ to 5 Tons. Contents. Product Features

ARPT Series. Multi-Position. 1½ to 5 Tons. Internal TXV, Multi-Speed PSC Motor

AVPTC. Air Handlers 1½ to 5 Tons

AEPF. 1½ to 5 Tons. Contents Nomenclature... 2 Product Specifications... 3 Dimensions... 4 Wiring Diagram... 6 Accessories... 7

AVPTC Multi-Position, Internal Txv

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

AVPTC Multi-Position, Internal Txv

ARPT Series. Multi-Position. 2 to 5 Tons. Internal TXV, Multi-Speed PSC Motor

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

DVPVC. Multi-Position, Variable-Speed Air Handler. Comfortnet - Compatible ECM-based Inverter-tuned Internal TXV

MBR. Multi-Position. Modular Blower

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor 1½ to 5 TONS. Contents. Product Features

AVPTC Multi-Position, Internal Txv

AVPTC. Multi-Position, Variable-Speed ECM Based Air Handler with Internal TXV ComfortNet Compatible 1½ to 5 Tons. Contents.

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible 1½ to 5 Tons. Contents. Product Features

GME8. Two-Stage Convertible, Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

ARPT Series. Multi-Position, Multi-speed Air Handler with Internal TXV and PSC Motor 2 to 5 Tons. Contents. Product Features

AVPTC. Air Handler 1½ to 5 Tons

ASPT Series. Multi-Position, Multi-Speed, ECM-Based Air Handler with Internal TXV 1½ to 5 Tons. Contents. Product Features

DVPEC. Multi-Position, Variable-Speed air handler. Comfortnet Compatible ECM-based Internal EEV, Inverter-tuned 2 to 5 Tons

MBVC. Multi-Position, Variable-Speed ECM-Based, Modular Blower ComfortNet Compatible. Contents. Product Features

ASUF Series. Multi-Position. Air Handler 1½ to 5 Tons

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

PRODUCT SPECIFICATIONS

ComfortNet -Compatible

MBVC. Variable-Speed, ComfortNet - Compatible Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

MBR. Multi-Position, Multi-Speed Modular Blower With PSC Motor. Contents. Product Features

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GCVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS92 / GCSS92. Single-Stage, Multi-Speed Gas Furnace Up to 92% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96. Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMVC96 (B) Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GMSS96 / GCSS96 Single-Stage Multi-Speed Gas Furnace

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position, Variable-Speed High-Efficiency Air Handler. 2 and 5 Ton

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

80% AFUE. Multi-Position, Dual$aver. Heating Input: 70, ,000 BTU/h

AEPT SERIES PRODUCT SPECIFICATIONS. Multi-Position Air Handler. 2 to 5 Ton

GMH95/GCH9 MULTI-POSITION, DUAL$AVER CONVERTIBLE, MULTI-SPEED GAS FURNACE

INSTALLATION AND MAINTENANCE INSTRUCTIONS. MCE4 Series. Electric Cooling Package Unit. Save these instructions for future reference

AMVM97 (B) / ACVM97 (B)

TECHNICAL MANUAL. ARPT**14**, ARUF**14**, ASPT**14**, ASUF**14** Air Handlers

Bosch BVA Series Air Handler

ADSH8. Two-Stage Convertible. Heating Input: 40, ,000 BTU/h

TECHNICAL SPECIFICATIONS

DM80HE. Two-Stage Convertible Multi-Speed ECM Gas Furnace 80% AFUE. Heating Input: 60, ,000 BTU/h

TECHNICAL SPECIFICATIONS

PRODUCT SPECIFICATIONS

PRODUCT SPECIFICATIONS

13 GEP A L P - 1 A

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

CONDENSING UNIT INSTALLATION INSTRUCTIONS. AIR CONDITIONING INSTALLATION & SERVICE REFERENCE Important Safety Instructions. Shipping Inspection

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

MERIT Series R-410A - Upflow / Horizontal

GME8 80% AFUE. Multi-Position, TwinComfort. Heating Input: 60, ,000 BTU/h

Wiring Diagrams. 9AB4-12 Air-Cooled Remote Condenser INDEX OPERATING SEQUENCE ACCESSORIES LEGEND AND NOTES FOR FIG. 1-6

TPLP PRE-ASSEMBLED LOW PROFILE EVAPORATORS

Bosch BVA Series Air Handler

MERIT Series R-410A - Upflow / Horizontal

TPLP Pre-Assembled. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION. Air & Electric Defrost

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

RGE 13 A T - 1 A

MERIT SERIES Up Flow / Horizontal

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: F6FP DESCRIPTION FEATURES UTG-B-0409

Product Data. 38AUQ Heat Pump Outdoor Unit Split System with Puronr Refrigerant 60 Hz FEATURES/BENEFITS

GMS95 GAS $AVER PRODUCT SPECIFICATIONS 95% AFUE. Multi-Position, Single-Stage/Multi-Speed Gas Furnace. Heating Capacity: 46, ,000 BTUH

TECHNICAL SPECIFICATIONS B6VMMX

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

Ruud Standard Efficiency Air Handler

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

TECHNICAL GUIDE. Acclimate MODELS: FL9S GAS-FIRED CONDENSING / HIGH EFFICIENCY UPFLOW SINGLE STAGE FURNACES 92% AFUE

AHP SERIES INSTALLATION INSTRUCTIONS ELECTRIC FURNACES / AIR HANDLERS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS DESCRIPTION FEATURES FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

Product Data PF1MNC DIRECT EXPANSION FAN COIL SIZES 018 THRU 061 FEATURES/BENEFITS AVAILABLE SIZES: 18,000 to 61,000 BTU unit ELECTRICAL RANGE:

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

The Premium Quality Fan Coil Units for Vertical, Horizontal (Left or Right) Application with Direct Expansion, Hydronic or Electric Heat

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Commercial High-Efficiency Condensing Units

INSTALLATION MANUAL SINGLE PACKAGE HEAT PUMP/ELECTRIC

Commercial High-Efficiency Condensing Units

FEM4X. Product Specifications FAN COILS /14/15

MBR. Modular Blowers. Cooling Capacity: 18,000-60,000 BTU/h

GMVC96. Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE. Heating Input: 40, ,000 BTU/h

GKS9 40" 90% Gas Furnaces

Condensing Units & Air Handlers

INSTALLATION MANUAL SINGLE PIECE AIR HANDLERS MODELS: F6FP018** - 060** TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES SAFETY UIM-B-0409

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

AIR HANDLERS AIR HANDLERS

TECHNICAL MANUAL. GMH95 40" 95% Gas Furnace

LOW VOLTAGE CONTROL CIRCUIT WIRING

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

Transcription:

ANF Series eiling-mount Air Handlers 1½ to 2½ Tons Standard Features Suitable for use with refrigerants R-410A and R-22 heck flowrater for heat pump and cooling-only applications All-Aluminum tube/aluminum fin coil Direct-drive, resilient-mount, multi-speed motor Sequence-controlled and rust-resistant nickel chromium heating elements of 5, 6, 8 and 10 kw High-efficiency evaporator coil Quiet operation Available with and without heat AHRI ertified ETL Listed Primary/secondary drain connection in a high-temperature plastic drain pan Suitable for free-return installation (non-ducted return air) Galvanized-steel construction Factory-installed pull-type disconnect Easy service access ontents Nomenclature...2 Heat Kit Data...2 Product Specifications...3 Dimensions...5 Airflow Data...6 Wiring Diagram...7 Accessories...8 * omplete warranty details available from your local dealer or at www. goodmanmfg.com. To receive the 10-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration is not required in alifornia or Québec. SS-GANF www.goodmanmfg.com 7/14 Supersedes 5/14

Nomenclature A N F 24 05 1 6 AA 1 2 3 4 5,6 7,8 9 10 11,12 Brand Engineering * A - Single- Piece Air Handler Major/ Minor Revisions Unit Application - eiling Mount PS Motor abinet Finish N - Uncased Expansion Device F - Flowrater Nominal apacity Range 18 = 2 Tons 24 = 2 Tons 30 = 2½ Tons *Not used for inventory management Refrigerant 6 = R- 410A or R- 22 Electrical 1-208/230 V, 1 Phase, 60 Hz 00 = No Heat 05 = 5 kw Heater Kit 06 = 6 kw 08 = 8 kw 10 = 10 kw 2 www.goodmanmfg.com SS-GANF

Specifications ANF18 0016 ANF18 0516 ANF18 0616 ANF18 0816 0016 0516 0616 Performance Ratings ooling (BTU/h) 18,000 18,000 18,000 18,000 24,000 24,000 24,000 Airflow Rate FM (High/ Low) ¹ 660/595 660/595 660/595 660/595 880/840 880/840 880/840 Piston Size ² 0.051 0.051 0.051 0.051 0.057 0.057 0.057 Blower Diameter 5.75 5.75 5.75 5.75 6.31 6.31 6.31 Width 6.75 6.75 6.75 6.75 8.25 8.25 8.25 oil connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" oil Drain onnect (FPT) 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum ircuit Ampacity 230V 0.9 27 33.5 40.6 1.68 27.8 34.3 Minimum ircuit Ampacity 208V 0.9 23.5 29.2 35.3 1.68 24.3 29.9 Max. Overcurrent Device (230V) 15 30 35 45 15 30 35 Max. Overcurrent Device (208V) 15 25 30 40 15 25 30 Minimum Voltage VA 197 197 197 197 197 197 197 Maximum Voltage VA 253 253 253 253 253 253 253 Blower Motor Full Load Amps (FLA) 0.72 0.72 0.72 0.72 1.34 1.34 1.34 Horsepower (HP) 1/8 1/8 1/8 1/8 1/4 1/4 1/4 Electric Heat kw @ 230 Volts 0.0 4.8 6.0 7.3 0.0 4.8 6.0 BTU/h @ 230 Volts 0 16,400 20,500 24,900 0 16,400 20,500 Ship Weight (lbs) 59 59 59 59 69 69 69 ¹ FM @.3 static ² Shipped with oil Notes For a properly matched system and piston sizing information, refer to Amana piston kit chart of the corresponding Amana outdoor unit. When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the A unit that has electric heat with a heat pump, order HEAT PUMP SHUT OFF KIT HPSK-01. The AXX-00 units do not require this kit. SS-GANF www.goodmanmfg.com 3

Specifications (cont.) 0816 1016 0016 0516 0616 0816 1016 Performance Ratings ooling (BTU/h) 24,000 24,000 30,000 30,000 30,000 30,000 30,000 Airflow Rate FM (High/ Low)¹ 880/840 880/840 1005/890 1005/890 1005/890 1005/890 1005/890 Piston Size 0.057 0.057 0.061 0.061 0.061 0.061 0.061 Blower Diameter 6.31 6.31 6.75 6.75 6.75 6.75 6.75 Width 8.25 8.25 8.25 8.25 8.25 8.25 8.25 oil connections Liquid ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" ⅜" Suction ¾" ¾" ¾" ¾" ¾" ¾" ¾" oil Drain onnect FPT 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" Electrical Data Voltage 208/230 208/230 208/230 208/230 208/230 208/230 208/230 Minimum ircuit Ampacity 230V 41.3 54.9 1.68 27.8 34.3 41.3 54.9 Minimum ircuit Ampacity 208V 36.1 47.8 1.68 24.3 29.9 36.1 47.8 Max. Overcurrent Device (230V) 45 60 15 30 35 45 60 Max. Overcurrent Device (208V) 40 50 15 25 30 40 50 Minimum Voltage VA 197 197 197 197 197 197 197 Maximum Voltage VA 253 253 253 253 253 253 253 Blower Motor Full Load Amps (FLA) 1.34 1.34 1.34 1.34 1.34 1.34 1.34 Horsepower (HP) 1/4 1/4 1/4 1/4 1/4 1/4 1/4 Electric Heat kw @ 230 Volts 7.3 9.8 0.0 4.8 6.0 7.3 9.8 BTU/h @ 230 Volts 24,900 33,500 0 16,400 20,500 24,900 33,500 Ship Weight (lbs) 69 69 79 79 79 79 79 ¹ FM @.2 static Notes:s When the room thermostat calls for second stage heat, the first stage (heat pump) operation must be locked out. When matching the A unit that has electric heat with a heat pump, order HEAT PUMP SHUT OFF KIT HPSK-01. The AXX-00 units do not require this kit. 4 www.goodmanmfg.com SS-GANF

Dimensions LIQUID LINE 21 ELET. HEATER LOATION 3/4 10 D 1 SUTION LINE ONTROL BOX THIS END: SUPPLY VOLTAGE WIRING OPPOSITE END: LOW VOLTAGE WIRING A B FRONT VIEW 4.375 TOP VIEW 11.197 4.699 SEONDARY DRAIN 3/4" FEMALE NPT PLASTI DRIN PAN 2.388 PRIMARY DRAIN 3/4" FEMALE NPT Model A B D ANF18 37¼" 34¾" 30" 6½" 43¼" 40¾" 36" 6½" 49¼" 46¾" 42" 6½" SS-GANF www.goodmanmfg.com 5

Airflow Data Model Motor Speed FM delivered against External Static Pressure 0.1 0.2 0.3 0.4 0.5 ANF180*** 0*** 0*** High 710 660 590 515 435 Low 650 595 540 480 390 High 955 880 820 740 675 Low 885 840 775 725 620 High 1,075 1,005 920 820 730 Low 945 890 835 760 650 Note: Airflow data for 240 Vac with dry coil and no filter in place. 6 www.goodmanmfg.com SS-GANF

ANF Wiring Diagram L1 POWER SUPPLY L2 DIS DIS 208/240 VOLTS * FL HTR2 PU FL HTR1 * TL TL * DIS DIS FL HTR2 TL H * * T1 L1 FL HTR1 TL H T 2 L 2 EBTDR EM PU SEE NOTE 1 N NO F LO L1 L2 WH BR T1 T2 BL BL GR XFMR-R R XFMR- G SU EBTDR N NO OM PU F SEE NOTE 4 BL BL YL BR SEE NOTE 1 TR 208V 240V 24V 24V GR WH BR BL GR SEE NOTE 5 SEE NOTE 2 EBTDR OLOR ODE WH WHITE GR GREEN BLAK PU PURPLE RED BR BROWN YL BL R TR YELLOW BLUE 208V 24V HI 240V SEE NOTE 5 WIRE ODE HIGH VOLTAGE FATORY WIRING LOW VOLTAGE HIGH VOLTAGE FIELD WIRING EBTDR LOW VOLTAGE NOTE 2 OMPONENT ODE DIS DISONNET SWITH ONTATOR EM EVAPORATOR MOTOR F FAN APAITOR EBTDR ELETRONI BLOWER TIME TL THERMAL LIMIT DELAY RELAY TR TRANSFORMER FL FUSIBLE LINK HTR HEATER ELEMENT BR SEE NOTE 2 H WH BL OM G GR EM NOTES: 1) TO PLAE UNIT IN LOW SPEED, REMOVE BLAK MOTOR LEAD FROM ELETRONI BLOWER TIME DELAY RELAY (EBTDR) OM TERMINAL AND REPLAE WITH RED MOTOR LEAD 2) SEE OMPOSITE WIRING DIAGRAMS IN INSTALLATION INSTRUTIONS FOR PROPER LOW VOLTAGE WIRING ONNETIONS. USE N.E.. LASS 2 WIRE. 3) ASTERISK (*) INDIATES THAT HEATING ELEMENT, THERMAL LIMIT, ONTATOR, & INTERONNETING WIRES OF HEATER #2 ARE DELETED WITH SINGLE HEATING ELEMENT UNITS. 4) EBTDR HAS A 7 SEOND ON DELAY WHEN "G" IS ENERGIZED AND A 65 SEOND OFF DELAY WHEN "G" IS DE-ENERGIZED. 5) FOR 208VA APPLIATIONS MOVE BOTH RED WIRES TO ENTER TAP 0140A00125-A Wiring is subject to change. Always refer to the wiring diagram on the Warning unit for the most up-to-date wiring. High Voltage: Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury, or death. * SS-GANF www.goodmanmfg.com 7

Accessories Model Description HPSK-01 Heat Pump Shut-off Relay Kit Louvered eiling Access Panels AP-1/ 1L AP-2/ 2L AP-3/ 3L Fits ANF18 Fits Fits Goodman Manufacturing ompany, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. 2014 Goodman Manufacturing ompany, L.P. Houston, Texas Printed in the USA. 8 www.goodmanmfg.com SS-GANF