Burner control unit PFU 780

Similar documents
Burner control units BCU 480

Burner control units BCU 480

Burner control units BCU 460, BCU 465

Industrial & Commercial Thermal BCU 580

Burner control unit BCU 370

Burner control unit BCU 370

Burner control units BCU 560, 565

Burner control units BCU 560, 565

Protective system controls, automatic burner control units, burner control units. Industrial & Commercial Thermal. 6 Edition 06.

Control valve S11T. Pilot burner ZT. Control valve S11T

Boiler module and operator-control unit KM 921 with CUI 9xx for heating boilers

Heating controller Lago

Self-recuperative burner for gas

Safety. Operating instructions UV sensor UVS 5 DANGER. Contents WARNING CAUTION Elster GmbH Edition Please read and keep in a safe place

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

LFL Series Burner Flame Safeguard Control

Safety. Operating instructions Ionization pilot burners ZAI, ZMI, ZKIH DANGER. Contents WARNING CAUTION Edition 12.11

Increased efficiency for drying, firing and glazing. Edition GB. Heat treatment in the ceramics industry

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

LAE10 LFE10. Use. Series 02

System Overview F300K Compact Flame Scanner. Sensors and systems for combustion engineering.

SERIES VAC Microprocessor-Based Direct Spark Ignition Control with Inducer Blower Relay FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

DATASHEET. Burner control unit FDA 601x

UV - flame detector dual fuel burners for intermittent burner operations

Manual MPA 41xx. Edition: Nr GB. Printed in Germany Edition Nr

Old documentation - Only for your information! Product is not available anymore!

DKG 972. Gas Burner Safety Control. For 2-stage atmospheric gas burners

Manual MPA 4112 PF. Edition: No GB. Printed in Germany Edition Nr

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

Energy management with a system. Edition GB. Control engineering and combustion technology for comfortable heating

EUROFLAT SERIES TYPES C... S... M...

Flame Monitors BROCHURE

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

System controller for cascade control, heating boilers with solar, buffer and pel et control

OPERATION MANUAL RK-2006LPP AUGER FITTED SOLID FUEL BOILER TEMPERATURE CONTROLLER. Version DC19

DMG 970. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

COMPACT FLAME CONTROLLER CFC 2000

Flame Safeguards LFE10. Building Technologies HVAC Products

1 - High-velocity gas burners

Eclipse Trilogy Flame Safeguards

EUROBOX SERIES TYPES CM... SM... MM...

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Advanced Ultraviolet Burner Controller

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

Increased efficiency for melting, heating and heat treatment. Edition GB. Gas-fired processes in the metalworking industry

Flame Safeguards LFE10. Building Technologies HVAC Products

DIRECTIVE NO: D-B

RIELLO 40 GS/M SERIES

Model 60200FR Gas Primary Control Data Sheet

Use. Burner controls for use with forced draught gas or gas / oil burners of small to medium capacity in intermittent operation.

Old documentation - Only for your information! Product is not available anymore!

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

SERIES 35-63J APPLICATIONS FEATURES SPECIFICATIONS AGENCY CERTIFICATIONS

AUTOMATIC BURNER CONTROL SYSTEM SAFETY INFORMATION CONFORMITY

On the job around the clock 24/7: Fire detection systems

AO Annunciator Module

25 Years IBS GmbH. Innovative and taylormade burner systems

Burner Management System

7800 SERIES RM7888A Relay Module

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

UV Flame Supervision System

IQ-Sense. 2/2 Introduction. 2/3 IQ-Sense photoelectric sensors. 2/5 IQ-Sense ultrasonic sensors. 2/6 4 IQ-Sense sensor module for ET 200S

SUPREMATouch. Modular Fire & Gas Detection System

Burner Management and Combustion Control. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

EUROBOX SERIES TYPES CM...N SM...N MM...N

Engineering Guideline. pac- Carriers Type Universal

Oil Burner Controls LMO24... LMO44...

SUPREMATouch. Modular Fire & Gas Detection System

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

FLAME AMPLIFIER MODULE 3001

7800 SERIES RM7840E,G,L,M Relay Module

Forced draught gas burner

7800 SERIES RM7840E,G,L,M; EC7840L Relay Module

Use. The burner controls are certified to EN 230 and EN 298.

Burner Management System

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DKO 974/976 DKO 974 N/976 N. Oil Burner Safety Control

COMPACT FLAME CONTROLLER CFC 100

Speed and Frequency Seite 1 von 7

COMPACT FLAME CONTROLLER CFC 1000

Power Flame Incorporated

Forced draught gas burner

D-GF 150. Burner Control for Gas and Oil Burners Flame Sensor D-GF 150 D-LE 103

7800 SERIES RM7888A Relay Module

Flame detector FD 2011 / FD 2012

STEAMPAK Series BurnerPAK BMS Burner Management Systems

7800 SERIES EC7885A/RM7885A Relay Module

Safety. Operating instructions Pilot burners ZAI, ZKIH DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 09.

Oil Burner Controls LMO24... LMO44...

MICROFLAT SERIES TYPES C.../U T X

MBCE-110/230UV Flame Sensor Module

Sola Hydronic Control. An Eco-Friendly Solution.

Operating Manual MS220KA and MSR220KA

MMI (40-34) Gas burner safty control

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

Transcription:

Burner control unit FU 780 roduct brochure GB 6 Edition 0. AGA For pilot and main burners of unlimited capacity in thermoprocessing equipment pursuant to EN 746- lug-in function unit for mounting in 9 module subracks Separate flame control for pilot burner and main burner by UV, ionisation or a further option of using the furnace chamber temperature Display of the program status, unit parameters and flame signal; Manual mode for burner adjustment and for diagnostic purposes Visualisation and adaptation to the specific application via the C programming and diagnostic software BCSoft to simplify logistics management Air valve control relieves the furnace control Certified for systems up to SIL 3 and compliant with L e

FU 780 Edition 0. FU 780 Module subrack BGT for instance serves to accommodate several function units. It is provided with a backplane with screw terminals for simple, reliable wiring. Application The burner control units FU 780 control, ignite and monitor gas burners for intermittent or continuous operation. As a result of their fully electronic design they react quickly to various process requirements and are therefore also suitable for frequent cycling operation. The FU 780 can be used for industrial burners of unlimited capacity which are ignited by pilot burners. ilot and main burners are controlled and monitored independently. This reduces the main burner start-up time. The pilot burner can burn permanently or be switched off. The main burners may be modulating or stage-controlled. On industrial furnaces, the FU 780 reduces the load on the central furnace control by taking over tasks that only relate to the burner, for example it ensures that the burner always ignites in a safe condition after it has been restarted. The burner control unit is used for burners with mechanical combustion air supply where the fan is controlled by a separate logic and for atmospheric burners. The air valve control on the FU 780L assists the furnace control for cooling, purging and capacity control tasks. The program status, the unit parameters and the level of the flame signal can be read directly from the unit. ilot and main burners can be controlled manually for commissioning and diagnostic purposes. If the local requirements on the burner control units change, the C software BCSoft can be adjusted to the unit parameters of the application by using the optical interface. To support service personnel, BCSoft offers a convenient visualisation system of the input and output signals and the error history. Bogie hearth forging furnace in the metallurgical industry Intermittent shuttle kiln in the ceramics industry Walking beam furnace with overhead firing

FU 780 Edition 0. 3 Examples of application FU 780 e 8e a 0c 6c 6e L, N, E 30e SS LC CE A 8c 0a ϑ ϑ 0e 4a 8a e 4e c 4c 6a 6e Stage-controlled main burner with alternating pilot burner Control: Main burner ON/OFF. The main burner can be started with reduced capacity after the operating signal from the pilot burner has been detected. The pilot burner is switched off automatically after the main burner has started up. When the main burner is switched off, the pilot burner automatically switches on again. A UV sensor monitors the flame signal from pilot and main burners. UV sensor UVD is used for continuous operation, UV sensor UVS for intermittent operation. TZI VBY VAG UV VR..L 0 04 06 08 0 04 06 08 ϑ ϑ t

4 FU 780 Edition 0. Stage-controlled main burner with permanent pilot burner Control: Main burner ON/OFF. L, N, E SS LC CE A ϑ ϑ The main burner can be started with reduced capacity after the operating signal from the pilot burner has been detected. ilot and main burners can be operated simultaneously. Both are ionisation-controlled independently. FU 780 a 0c 6e 30e 0a 0e 4a e 4e c 4c e 8e 6c 8c 6a 8a 6a 6e VBY TZI VAG VR..R 0 04 06 08 04 06 08 04 ϑ ϑ t

FU 780 Edition 0. 5 Modulating-controlled burner Control: Main burner continuous FU 780 a 0c 6e L, N, E ma SS LC CE ϑ 0e ϑ 4a e 4e The butterfly valve for air BV is moved to ignition position in order to start the main burner. The main burner can be started at low-fire rate after the operating signal from the pilot burner has been detected. The control system controls the burner capacity via the butterfly valve for air BV after the operating state has been signalled. ilot and main burners can be operated simultaneously. c 4c 8e 6c 8c 6a 8a 6a 6e VBY TZI VAG M BV+IC

6 FU 780 Edition 0. FU 780..D: High temperature equipment The flame is controlled indirectly on the basis of the temperature. During the start-up process, as long as the wall temperature is below auto ignition temperature the flame must be controlled by conventional methods. When the working temperature has exceeded 750 C, the safety temperature monitor (STW) takes over the indirect flame control. FU 780..D STW >750 C L FU 780..D 6a 6a 8a 8a a a

FU 780 Edition 0. 7 Technical data Mains voltage: 0/40 V AC, -5/+0%, 50/60 Hz or 0/0 V AC, -5/+0%, 50/60 Hz, for grounded and ungrounded mains. ower consumption: < 8 VA. Control inputs: Input voltage/current: ilot burner, main burner, air valve, multiflame control and remote reset: 4 V DC, ± 0%, < 7 ma per input. Input voltage for safety interlocks, digital input and purge = mains voltage. Input voltage of signal inputs: Rated value 0/0 V AC 0/40 V AC Signal 80 3 V 60 64 V Signal 0 0 0 V 0 40 V Frequency 50/60 Hz 50/60 Hz Rated value 4 V DC Signal 4 V, ±0% Signal 0 < V Inherent current: Signal typ. 5 ma Output voltage for voltage-related outputs = mains voltage. Contact rating Gas valve V, V Max. A resistive Max. A cos ϕ 0.3 Air valve Max. A resistive Max. A cos ϕ 0.3 Ignition Max. A resistive Max. A cos ϕ 0.3 Number of operating cycles Max.,000,000, typically 400,000 Max. 50,000, typically 00,000 Output current: max. A per output, but total current for valves and ignition transformer max..5 A. Operation and fault signalling contacts: dry contact (floating), max. A, 4 V, not fused internally. Number of operating cycles: Mains switch: 000, Reset/Information button: 000. Flame control: Sensor voltage: approx. 30 V AC. Sensor current: > µa, Length of sensor cable: max. 00 m. Fuse in unit: F: 3.5 A, slow-acting, H pursuant to IEC 7-/5, F: 3.5 A, slow-acting, H pursuant to IEC 7-/5. Ambient temperature: -0 to +60 C (-4 to +60.00 C), Climate: no condensation permitted. Enclosure: I 00 pursuant to IEC 59, after installing in a 9 module subrack according to the instructions, e.g. type BGT, the front corresponds to I 0. Input/Output safety circuit: All the inputs and outputs marked (see connection diagrams) may be used for safety tasks. Weight: approx. 650 g (3 oz.).

8 FU 780 Edition 0. Type code Code Description L Air valve control Mains voltage T 0 40 V~, -5/+0 %, 50/60 Hz N 0 0 V~, -5/+0 %, 50/60 Hz D* Digital input to interrupt fl ame control U* reparation for UV sensor for continuous operation UVD K* Compatible with FU 798 * If none, this specifi cation is omitted. Detailed information on this product Contact www.kromschroeder.com Sales Elster GmbH ostfach 809 4908 Osnabrück Strotheweg 49504 Lotte (Büren) Germany T +49 54 4-0 F +49 54 4-370 info@kromschroeder.com www.kromschroeder.com http://docuthek.kromschroeder.com/doclib/main.php?language=&folderid=0640&by_class=6 We reserve the right to make technical modifications in the interests of progress. Copyright 04 Elster GmbH All rights reserved. 0350648