Reference F-IAB-012 Page Page 1 of 6 Revision 2. Please complete all sections and submit electronically to

Similar documents
Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

Energy Rating Report

Guidance Note No 19/1. CE Marking windows and doorsets

Contents EN :2006+A2:2016 (E)

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

CEN/TC 33 - Doors, windows, shutters, building hardware and curtain walling. EN 107:1980 Methods of testing windows - Mechanical test 89/106/EEC

Annex of the certificate (Page 1/7) Accreditation Scope

EN CE instead of approval Opportunities for manufacturers and trading to enter new markets in Europe

Construction Products Directive

Construction Products Directive

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TTOWNHOUSE SASH WINDOW SASH WINDOW

CE marking of fire-resistant doors the right way!

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

This document is a preview generated by EVS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

FLAMEBREAK. Rev.D Mechanical Performances - General: TM

NF MARK THERMOPLASTIC MATERIAL DRAIN OR SEWER SYSTEM OPERATING WITHOUT PRESSURE

Guidance on Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

GASTEC QA. Approval Requirements 31-1

Declaration of Performance and CE marking of windows and external pedestrian doorsets according to the CPR

ACCREDITATIONS. MEMBERSHIPS & AWARDS. Quality counts, don t settle for anything less... BSI Kitemark for energy rated windows

GASTEC QA. Approval Requirements 31-2

PERFORMANCE & TESTING

Title: The Air Leakage Performance of Timber Doorsets fitted with NOR710 Smoke Seals in Accordance with BS 476: Part 31, Section 31.

Loss Prevention Standard

F O C U S D O O R C L O S E R S

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

7.3 Design and Development Design and development planning Design and development inputs Design and development outputs 7.3.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

Conformity assessment procedures for the Alarm Components Scheme

NF MARK RIGID NON-PLASTICISED PVC PIPES AND FITTINGS TECHNICAL DOCUMENT 5: BIAXIALLY-ORIENTED PRESSURE PIPE GROUP

PPA Michaël GROSSI - FSCE PR electronics

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

FUNCTIONAL SAFETY CERTIFICATE

The WWA Standard for manufacturing wood windows and window performance

The Passive Fire Protection Handbook

PROCEDURES FOR APPROVAL OF LIFE-SAVING APPLIANCES AND FIRE SAFETY SYSTEMS, EQUIPMENT AND PRODUCTS

Technical Bulletin CE marking: from 1st July 2013

GASTEC QA. Approval Requirements 15. for the GASTEC QA product certificate for Steel pipes and sockets for the transport of gas. KE 15 January 2012

Aon Sprinkler Certification Technical Note

Strebord 35 FD30 Strebord 44 FD30 Strebord 54 FD60

Dear Customer. Section Old F8 February 2014 Amendments to F8. Replace with new title page and document history pages 1 2B

This document is a preview generated by EVS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

YOUR GUIDE TO UNDERSTANDING CPR

Practice Guidee No.1. of the

Cylinder Mortice Dead lock Lockcase(mm) A=87 Backset (mm) B=55. Follower (mm) 8 Latch Bolt

Specifying Security Hardware for Doors

Standards and Standardisation. An Overview

Contents. EN :2012 (E) Issue 5 ( ) Page

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Mechanically operated locks and locking plates

This is a preview - click here to buy the full publication ICS ISBN

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Controlled Door Closing Devices

EXTERNAL SCREEN CLASSIC NATTÉ 4503 COLLECTION INTELLIGENT FABRICS FOR SOLAR PROTECTION. Width: 250 cm

NES. What s New June Contents: Detailed Technical guidance. Work section updates. (key points)

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Recent Topics in IEC TC 62 (Electrical Equipment in Medical Practice) and its Subcommittees

INTERNATIONAL STANDARD

SOUTH AFRICAN NATIONAL STANDARD

Sýnishorn Glass in building - Insulating glass units - Part 5: Evaluation of conformity

The Passive Fire Protection Handbook

SCREEN DESIGN M-SCREEN 8501 COLLECTION INTELLIGENT FABRICS FOR SOLAR PROTECTION. Widths: Up to 320 cm

L411:P43 D11:X421. CI/SfB. (31 5) Xh4

ISO/TS TECHNICAL SPECIFICATION

INTERNATIONAL STANDARD

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

Test on extruded rigid PVC profile for concrete formwork at 50 kw/m² irradiance in

Loss Prevention Standard

Panic and Emergency Exit Devices

This document is a preview generated by EVS

Abrasion Resistance of Fluoropolymer and polyester Coatings

CPVC solvent cements for CPVC pipes and fittings

A Guide to the Selection of Smoke Seals for Doorsets. Information Sheet No. 5. Intumescent Fire Seals Association

CE MARKING OF WOOD-BASED PANELS

CE Marking and Technical Standardisation

PQS performance specification

FAKRO Roof Window Systems

Rose. Specifiers Brochure. Authentic sash windows loaded with modern features

Schueco Fire and Smoke Protection Systems

Product Guide Specification

Best practice guide. Door coordinator devices to BS EN in association with. Association of Building Hardware Manufacturers

TOPAZE CONTEMPORARY WINDOW. Architect: Opera Architecte Photography: J.C. Ballot

Electromagnetic Locking Devices Performance Requirements

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

DIVISION C ADMINISTRATIVE PROVISIONS

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

C-01 FIRE DECKS AND BULKHEADS

SilverScreen. The innovation in solar heat and light control

Gas Emergency Response

BRE & LPCB Ruth Tucker -Passive Fire Protection

CE marking of industrial doors under the CPR Michael Skelding, Secretary and General Manager Door and Hardware Federation

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

Transcription:

Agrément Form Title WINDOW ENERGY PERFORMANCE (WEP) APPLICATION FORM Reference F-IAB-012 Page Page 1 of 6 Revision 2 Please complete all sections and submit electronically to anne.clarke@nsai.ie Section 1.0 - Company Details Company Name Address Telephone Fax Trading Name (if different from above) Company Contact Job Title Personal E-mail 2 nd Contact Name E-Mail Website Indicate your company s Quality Management System (QMS); ISO 9001 or I.S. EN 14351-1:2006 Factory Production Control (FPC) or similar documented system. Give details of the QMS Section 2.0 Window Assembly Details complete for each window arrangement. WEP Certificate Number. (Office Only) Frame Material (aluminium, PVC-U, steel, timber or a combination of materials). Window Description, Technical Summary. Gas/Glass thickness/ emissivity etc. Glazing unit (Double/Triple) Window Type Product/assembly Name Certified Simulator Address WEP Index 3DP Casement Fixed Light/Side Hung 1480 High x 1230 Wide Casement Fixed Light/Tilt & Turn 1480 High x 1230 Wide Vertical Sliding Sash - 1480 High x 1230 Wide Thermal Transmittance U window (W/m 2.K) 2DP Effective Air Leakage L factor (W/m 2.K) 2DP Solar Factor g window Solar Energy Transmittance (g ) 2DP 2DP Thermal Transmittance Window U window (W/m 2.K) 2DP Air Leakage Report Report number and testing agency. Confirm window arrangement achieves a L 600 Class 4 classification to I.S. EN 12207:1999 11 L 600 = L 50 = Telephone WEP Rating (A1,A2,A3,B etc) Applicant Name: Date: wep rev 8 1

Application Form Guidance Notes. Guidance notes for completion of WEP Application process. 1. Prior to applying for a WEP rating, manufactures are advised to engage the services of a Certified Simulator, to carry out an initial assessment of their window assembly. This should give a good indication as to your likely WEP rating. In addition, the initial assessment, will allow you the opportunity to make amendments to the product specification to improve the final WEP rating. 2. Manufactures must install a recognised Quality Management system (ISO 9001 or similar documented system). Details of your management system and procedures should accompany your WEP application. If no such quality management system exists, manufactures must implement one and this system should have a minimum of 3 months operating history prior to the date of audit. 3. Once satisfied with your Certified Simulator s rating, you should submit all documentation to NSAI Agrément. This should include completed application form, test reports, along with your full assessors report, your quality management documentation and application fees. 4. The NSAI Agrément fee structure is associated with each label that you register and is charged on an annual basis. See www.nsai.ie for the current fee structure. The Certified Simulator fees are separate and should be paid directly to them. If independent testing is required then these costs are separate and should be paid directly to the independent testing agency. 5. Upon receipt of the appropriate fee, the NSAI will carry out an audit of your manufacturing facility and assess your Certified Simulator s report. Sample WEP Certificate 6. Once successful completion of stage 5, your company will be registered with the NSAI and each successful window assembly will be issued with a unique registration number. The registration number must be displayed on the reveal of the fixed sash jamb or fixed sash head (F10 or F8 or F6 see Fig. 1.0). Each window type will be issued with a WEP Certificate number and permits the manufacturer to affix the Energy rating identification mark to their product. 7. The WEP rating is calculated by combining the Thermal transmittance (U w ), Solar factor (g-value) and Window air leakage (L 50 ) factors using the following formula WEP Rating = 218.6 x g-value - 68.5 (U w +L 50 ) wep rev 8 2

Guidance notes for Certified Simulator s assessment. 1 Analysis Method Simulators must state the analysis method s used. This including all software packages used and copies of all independent test report from which data has been incorporated into the Simulator s report. 2 Validation of Program The analysis software used in assessing the thermal performance of any window assembly must be validated against the proofs in Annex D (D1 to D10) of IS EN ISO 10077-2:2003 2 Thermal Perform of Windows, Doors and Shutters - Calculation of Thermal Transmittance- Part 2: numerical Method for Frames. A statement to this effect must be contained within the Simulator s report. 3 Standard Window assembly. The standard window assembly used to calculate the WEP ratings shall be a single opening casement type 1480 high x 1230 wide as shown in figure 1.0. Window assemblies must comply with the requirements of TGD to Part D of the building regulations. All window assemblies must be I.S. EN 1279 14-19 compliant. 4 Thermal transmittance Window U window (U w ). The thermal transmittance of the standardised window assembly shall be calculated by combining the thermal transmittance of the glazing (U g ) with the thermal transmittance of the frame (U f ) and the linear thermal transmittance due to the combined thermal effects of the glazing, spacer and frame (Ψ g ). Frame thermal transmittance (U f ) shall be determined by using: I.S. EN ISO 10077-1:2006 1 Thermal Perform of Win Doors and Shutters Cal of Thermal Transmittance Part 1: General, Table F.1 or by calculation using: I.S. EN ISO 10077-1:2006 1 or I.S. EN ISO 10077-1:2006 1 and I.S. EN ISO 10077-2 2 Thermal Perform of Win Doors and Shutters Cal of Thermal Transmittance Part 2: Numerical Method for Frames or by hot box method using: I.S.EN12412-2-2003 4 Thermal Performance of windows, Doors and Shutters - Determination of Thermal Transmittance by Hot Box Method - Part 2: Frames as appropriate. The thermal transmittance of the glazing (U g ) shall be determined by calculations using I.S EN 673 6 Glass in building - Determination of thermal Transmittance (U-Value) - Calculation Method; or measured according to I.S.EN674-1998 7 Glass in building - Determination of Thermal Transmittance - Hot Plate Method or I.S.EN675-1998 8 Glass in Building - Determination of Thermal Transmittance - Heat Flow Meter Method; Linear thermal transmittance (ψ g ) due to the combined thermal effects of the glazing, spacer and frame must be assessed following the principles of I.S. EN ISO10077-2 2 or wep rev 8 3

Determination of complete thermal transmittance (U w ) by the hot-box method in accordance with I.S. EN ISO 12567-1:2001 5 Thermal Performance of windows DOORS - Determination of Thermal Transmittance by Hot Box Method -Part 1: Complete Windows and Doors 5 Effective Air Leakage (L 50 or L factor ) Determine the Effective Air Leakage per unit length of opening length at both 600Pa and 50Pa in accordance with: BS 6375-1:2009 9 Performance of windows and doors Part 1: Classification for weather tightness and guidance on selection and specification or I.S. EN 12207:1999 11 Windows and doors - Air permeability - Classification and I.S. EN 1026 10, Windows and doors Air permeability Test method. It shall not be necessary to carry out the sequence of tests as outlined in Clause 5 of BS 6375-1:2009 9 namely parts b, c, d and e. The specimen shall be tested in accordance with Clause 6 of BS 6375-1:2009 9 and/or I.S. EN 1026 10 and the test shall be conducted with both positive and negative pressures. The test pressure shall be applied in steps of 50 Pa up to 300 Pa and from 300 Pa in steps of 150 Pa up to 600 Pa maximum. The test result, defined as the numerical average of the positive and negative air permeability values (m 3 /h) at each pressure step, shall be expressed and classified in accordance with I.S. EN 12207:1999 11. While the L 50 value is used in calculating the WEP rating all window assemblies must achieve a L 600 Class 4 classification to I.S. EN 12207:1999 11. Calculate the total air leakage as a fraction of the total area and convert the L 50 factor to Heat Energy loss by multiplying by the conversion factor 0.0165 Wh/Km 3. 6 Total solar energy transmittance (g-value). Determine the solar energy transmittance (g ) in accordance with I.S. EN 410 12, Glass in building Determination of luminous and solar characteristics of glazing. The solar energy transmittance g should be converted to the time-averaged transmittance as per I.S. EN 832:1998 13 Thermal Performance of Buildings - calculation of Energy use for Heating - Residential Buildings. When using Manufacturers values you must provide reports from the manufacture confirmation the values used I.S. EN 410 12 7 Summary of Results Reports must contain a summary of results. All information required to verify the analysis must be submitted in electronic format (i.e. CD). Simulation reports must list out all materials used and their thermal conductivity used. Reports must list the frame thermal transmittance (U f ) for the fixed frame, the sash and the Mullion in W/(m 2.K). Reports must list the Liniar thermal transmittance (ψ) for the fixed frame, the sash and the Mullion in W/(m.K). AutoCAD drawings of the overall window assembly at a scale not greater that 1:10 with sectional details of all frame and glazing section (scale 1:2) must be provided. The drawings must label all component parts and their thermal conductance used. wep rev 8 4

Figure 1.0 Normative references Classification standards, Test and calculation standards. 1. I.S. EN ISO 10077-1:2006 Thermal Perform of Win Doors and Shutters Cal of Thermal Transmittance Part 1: General 2. I.S. EN ISO 10077-2:2003 Thermal Perform of Win Doors and Shutters Cal of Thermal Transmittance Part 2: Numerical Method for Frames 3. I.S. EN 14351-1:2006 Windows and Doors - Product Standard, Performance Characteristics - Part 1: Windows and External Pedestrian Doorsets without Resistance to fire and/or smoke Leakage Characteristics. 4. I.S. EN 12412-2:2003 Thermal Performance of windows, Doors and Shutters - Determination of Thermal Transmittance by Hot Box Method - Part 2: Frames 5. I.S. EN ISO 12567-1:2001 Thermal Performance of windows DOORS - Determination of Thermal Transmittance by Hot Box Method -Part 1: Complete Windows and Doors 6. I.S EN 673:1998 Glass in building - Determination of thermal Transmittance (U- Value) - Calculation Method 7. I.S. EN 674:1998 Glass in building - Determination of Thermal Transmittance - Hot Plate Method 8. I.S. EN 675:1998 Glass in Building - Determination of Thermal Transmittance - Heat Flow Meter Method 9. BS 6375-1:2009 Performance of windows and doors Part 1: Classification for weather tightness and guidance on selection and specification 10. I.S. EN 1026:2000 Windows and doors Air permeability Test method. 11. I.S. EN 12207:1999 Windows and doors - Air permeability - Classification 12. I.S. EN 410 Glass in building Determination of luminous and solar characteristics of glazing 13. I.S. EN 832:1998 Thermal Performance of Buildings - calculation of Energy use for Heating - Residential Buildings wep rev 8 5

14. I.S. EN 1279-1:2004 Glass in Building - Insulating glass units - Part 1: Generalities, Dimensional Tolerances and Rules for the system description 15. I.S. EN 1279-2:2002 Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration. 16. I.S. EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances 17. I.S. EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Method of test for the physical attributes of edge seal 18. I.S. EN 1279-5:2005 Glass in building - Insulating glass units - Part 5: Evaluation of conformity 19. I.S. EN 1279-6:2002 Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests 20. I.S. EN 10088-1:2005 Stainless steels - Part 1: List of stainless steels 21. I.S. EN 514:2000 Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors - Determination of the strength of welded corners and T-joints 22. I.S. EN 14220:2006 Timber and wood-based materials in external windows, external door leaves and external door frames - Requirements and specifications 23. BS 644:2009 Timber windows Fully finished factory-assembled windows of various types Specification 24. I.S. EN 12608:2003 Unplasticized polyvinylchloride (PVC-U) profiles for the fabrication of windows and doors - Classification, requirements and test methods. 25. BS 7412:2007 Specification for windows and doorsets made from unplasticized polyvinyl chloride (PVC-U) extruded hollow profiles wep rev 8 6