OKM 801INFANT INCUBATOR

Similar documents
BiliCare INTENSIVE PHOTOTHERAPY

BT-500. Infant Incubator. BT-500 Infant Incubator

SPECIFICATION FOR MULTIPARAMETER MONITOR

CLEO VERSATILITY IN VITAL SIGNS

Vitalmax 4000 CL Product Specifications

OMNI Express VS VERSATILITY IN VITAL SIGNS

İndex SUCTION UNIT... PATIENT MONITOR HOLTER SYSTEM... 7

EC 160 CO 2. Incubator

ENVAIR lab CO2 Tri-Gas Incubator

Nellcor with OxiMax Technology Product Ordering Guide A Full Line of Oximetry Sensors and Monitors

1 Appendix - Product Specifications

Ohio Care Plus Series 1000/2000 Incubator. Operation and Maintenance Manual

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

OMNI TOUCH SCREEN PATIENT MONITOR

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Controlled Environment Equipment Solutions for the Lab

108A OTP1800. Grid Support. General Description

ila ACTIVVE SYSTEM PLATFORM

THERMOMETERS Dataloggers/Refrigerator

Incubators THE BENCHTOP EQUIPMENT HYGIENE SOLUTION

Platelet bags constant shaking for long periods of time.

Professional Design Project

Incubators. with BioCote antimicrobial protection

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

intuitive, intelligent, interactive

Benchtop CO 2 Incubator. the Oasis 6400 series

Simple and Versatile

VWR symphony CO 2 INCUBATORS

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

Omni (K) PATIENT MONITOR

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Igloo. Ultra low temperature freezers -45 o C & -86 o C Upright & Chest 370 to 830 liter

laboratory & sterilization technology

BLOOD BANK REFRIGERATOR - BR Series

The Professional Choice

Technology, Quality, Reliability and Repeatability. ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. 1

LEAKSTOPPER 1 Single zone water leak detection system

User Manual. Digi-Sense TC9500 Advanced Multiparameter Temperature Controller with Thermocouple, Thermistor, and RTD Inputs

OGB PolyTrend (8070) Intensive Care Incubator User Manual

T-32-TS Touchscreen Thermostat. Installation Manual

LMV52 Control. Specifications. Document No. LV February 3, Product Description. Sample Specification

The No.1 choice for Veterinary care and animal recovery.

www. szcomen. com COMEN - SHARE WITH THE WORLD

Undercounter Refrigerator Operation Manual i.series and Horizon Series

Warranty Registration

OPERATING INSTRUCTIONS FOR LEEC AUTOMATIC CO2 INCUBATORS. MODELS GA2000 and GA2010 MODELS GA3000 and GA3010 With Infrared CO2 detectors CONTENTS

incubator, the best in its class

MICROCAPSTAR End-Tidal CO 2 Analyzer Instruction Manual

Techne Dri-Block range. Premium products at affordable prices. Adjustable safety cut-out. 230V and 115V variants. New 5-digit LED display

Analox 1000 Series. User Manual. Analox Sensor Technology Ltd. 15 Ellerbeck Court, Stokesley Business Park North Yorkshire, TS9 5PT, UK

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

CO2 INCUBATOR CO2 INCUBATORS

BIOMEDICAL REFRIGERATORS

A Safe, Stable Environment for Culturing Cells. Easy Set-Up Control and Monitoring. Sophisticated Alarm, Security and Back-Up Systems

Dry Block Heaters. Dry Block Heaters. 2 Block Dry Block Heaters with Lid.

Model gffoz Process Ozone Sensor (In-Line)

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

COA-2010-F Electronic CO 2

FROILABO offers a full range of incubators with natural convection, air forced or forced cooling to cover most laboratory applications.

The Professional Choice

Reach-In. PLanT GROWTh. Reach-In

Dual-Mode Infrared Thermometer Instruction Manual

Feature : SEKARGUNA MEDIKA

VHP ARD BIODECONTAMINATION SYSTEM

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

Biomedical Freezer 37 38

portable gas analyser

PATIENT MONITORING SYSTEMS

CO2 INCUBATORS. The Safer Choice for Your Laboratory. NuAire, Inc Fernbrook Lane Plymouth, MN U.S.A. nuaire.com

Rad-87. Pulse CO-Oximeter OPERATOR S MANUAL

CA5000 Liquid CO 2 Freezer Backup System

THERMAX Efficiency Monitor

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Multi-Parameter Patient Monitor

intuitive intelligent interactive New! Thermo Scientific Heracell 150i and 240i CO 2 Incubators

BlueSpin Magnetic Hotplate Stirrer

Airflow Sensors Line Guide

Dry Block Heaters. Dry Block Heaters 2 Block Dry Block Heaters with Lid.

ConchaTherm Neptune Heated Humidifier User s Manual /07 English (EN)

Safe Operation Manual. Honeywell IQ Force Gas Detector

TOOLS AND INSTRUMENTS

QAS SERIES PLUG-IN CONTROLLERS c/w SOLID STATE SENSOR

ABSOLUTE Temperature Control System

Atlas Monitor Outline Train the Trainer

NEW GENERATION. Efficient use of valuable space INCUBATORS

Blood bank refrigerators

Warner Instruments, Inc Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

REFRIGERATOR M E D I C A L.

portable gas analyser

Advance Blood Storage system from Meditech

LEAKSTOPPER RANGE Multizone water leak detection systems

s ter k Hea y Bloc Dr

HAMILTON-H900. Intelligent humidification for all patient groups

DWYER INSTRUMENTS, INC. P.O. BOX 373 MICHIGAN CITY, INDIANA 46360, U.S.A. Series 670 Hood Monitor. Bulletin AV-670

APPLICATION DATA SHEET

Refrigerated Incubator Model and Operating Instructions

P/N: Release Date: January 2012 Copyright EDAN INSTRUMENTS, INC All rights reserved.

Operation & Maintenance Manual

Transcription:

OKM 801INFANT INCUBATOR

OKM 801 INFANT INCUBATOR 02 OKM 801 Infant Incubator Premature and / or infants which might have serious health problems after delivery they need close caring of the physician and the nurses because they are not capable to keep their body temperature at the required level and stability by their own. Besides the medical cure, in order to improve health conditions; patients need a fresh air in a steril environment with constant temperature and appropriate humidity as well as silence which do not interrupt their sleep. Also have optional Haemodynamic monitoring features alongwith additional external display. Simple viewing of all modes and applicable set values of the parameters. OKM 801 Infant Incubator is specially designed with high technology to meet all necessary requirements and makes difference in NICU.

Stable With ambient temperature probe OKM 801 infant incubator is able to compare the difference between ambient and setting temperature, and changing heating power output accordingly in order to provide more stable inside hood air temperature. The micro processor controlled unit has automatic Self test function. Skin temperature monitoring through Reusable & Disposable sensor Air circuit temperature monitoring More accurate temperature control and safer system Temperature 1 Connector Temperature 2 Connector Minimize Temperature Uniformity OKM 801 incubator s air circuit system is designed based on massive experimentation. With plenty aerodynamics knowledge the temperature uniformity is improved as much as possible in order to give infant the safest micro-environment. Allows the temperature to be monitored on two different (T1 and T2) points of the body for more accuracy to maintain targeted temperature level. Super Quiet Design It is approved that in addition to the direct auditory effects of noise, noise also influences the cardiovascular system, the respiratory system, sleep patterns, and stress levels of neonates. OKM 801 provides newborn a super quiet environment, hood sound is reduced to 45dB. Detachable Sensor Module Sensor module is connected with incubator main body 20 pin connector. During maintenance and service it can be removed easily. Three Channel Temperature Sensors There are three channel of temperature sensors in the module box. One channel is for reading hood temperature to remain the temperature at setting value. Another temperature sensor is used to compare the reading with other two sensors. If the reading of three sensors differ from 0.8 C, alarm is triggered. OKM 801 with External Screen/ Haemodynamic Monitor Humidity Sensors Humidity sensor is for reading humidity level in incubator. When the water level is low in the autoclavable water reservoir, an audible and visual Low Humidity alarm occurs. Oxygen Sensors (Optional) The oxygen control system adjusts the flow of oxygen within the incubator hood with a valve and an oxygen sensor module. The sensor module has two independent oxygen fuel cells. When the sensor module is outside of the hood during Oxygen Control mode, audible and visual alarms are enabled, and the flow of oxygen is interrupted. Temperature and Humidity Sensor Oxygen Sensor (Optional) 03 Backup Battery OKM 801 is equipped with backup battery, once power supply is off, the backup battery supports the air circuit and alarm system to keep working at least 30 minutes. Also external monitor with haemodynamic parameters will have a separate power backup.

8 Color LCD Touchscreen display provides all incubator parameter users to operate soft buttons as well as touchscreen Touchscreen OKM 801 Infant Incubator 04 Can be operated from both side of hood Ergonomic designed handle with perfect height 1,5 liter water reservoir enables OKM 801 to keep running for 36 hours. Big storage drawers Detachable water reservoir, easy to clean and sterilize Three auxiliary power output Optional Height Adjustment Haemodynamic Monitor with essential Incubators parameters. Tente castor with lock

Other Features / Air Curtain While the front or back access panels open, the air circuit motor rotation rate is accelerated automatically. Therefore more warm air is delivered to the hood. It effectively prevent heat lose and provide infant stable micro-environment. Haemodynamic Monitor Double Wall Design Air Curtain Alarm Audio & Visual Display Temperature Monitoring and Protection Alarms OKM 801 infant incubator monitor and control temperature on various points on heating system to ensure accuracy and safety. The alarms will be actived if any unmoral phenomenon is monitored. High Skin Temperature Low Skin Temperature High Skin 1 Temperature High Skin 2 Temperature Skin Probe Disconnect High Air Temperature Low Air Temperature Electronic circuit fault as High Temperature Cut Out Sensor Monitoring Alarms OKM 801 incubator monitors the condition of air, humidity, oxygen sensors, air flow probes and sensor box to ensure all the data collected are true and accurate. Alarms are triggered when any errors related to the operation of the sensors are detected. Humidity Heater Failed Add water Low Humidity (moisture) Reservoir Out Of Position Oxygen Cell Difference Low Oxygen Ratio High Oxygen Ratio Check O2 Supply Servo O2 System Fail Change Oxygen Cells High Spo2 alarm Low Spo2 alarm External display failure alarm Separate Haemodynamic parameters failure alarms Working Condition Monitoring Alarms In order to keep proper running and provide the best user ecperience, OKM 801 infant incubator monitors the working condition of each aspect. 05 Motor Failed Power Failure Stuck Key Sensor Module Failure Sensor Disconnect Low Air Flow Air Flow Probe Failed Battery Disconnect Sensor Out of Position Access Panel Open Heater Failed Air Probe Failed Skin1 Probe Fail Alarm SpO2 sensor Fail Alarm Watchdog Failed

GENERAL SPECIFICATIONS Height 126.1cm to 146.1cm Tubing Access Ports 10 Width 99.7 cm Access Door Size 18x13 cm (Max. 6 doors) Depth 57.7cm Mattress to Hood Height 48.0 mm Weight 80 kg Soft Bed Mattress Size (Bed safety mechanism Package Dimensions 107*68*155 cm active when pulled outside) X-Ray Tray 41 x 38.9 cm Trendelenburg ±12 3100 cm2 standard (upto 77 x 40cm/ 3080cm2 on request) 06 TEMPERATURE CONTROL MODES OKM 801 Infant Incubator External Display for Incubator & Haemodynamic parameters (Optional) Power Supply and Frequency Temperature Control Modes Air Mode Control Temperature Range Air Mode Control Override Temperature Range Air Mode Control Accuracy Skin Mode Control Temperature Range Heat Cut of Temperature 8, 10 or 12 inches colour TFT 100-240 VAC and 50/60 Hz Hood cover opening Display of Parameters Trend Display Air Filter (Replacable) Skin and Air Temperature Control Modes 20 C-37 C 39 C-40 C ±1.0 C 34 C-37.5 C 40 C ± 0.8 C 180 (Both Front & back) Active & set values 2,4,8,12,24 Hours Min. 0.3 to Max. 0.5 macron Skin Mode Control Override Temperature Range Skin Temperature Accuracy Dual-Skin Temperature Monitoring 37.5 C-39 C ±0.3 C Yes PERFORMANCE Air Flow Velocity Across Mattress Temperature Rise Time At 22 C (72 F) Ambient < 10 cm/sec <20min (From 22 C, 50% RH, to 35 C) Temperature Variability < 0.5 C Temperature Overshoot < 0.5 C Maximum Temperature Uniformity With A Level Mattress < 0.8 C Operating Noise Level In Hood 45dBa Carbon Dioxide (Co2) Level <0.5% SERVO HUMIDITY (OPTIONAL) With AutoClean Function of Autoclavable Chamber Humidity Control Range Humidity Control Operating Time Without Refilling Humidity Control Reservoir Capacity Humidity Display Accuracy Humidity Control Accuracy 30% - 95% RH 24 hours 1500 ml ±5% RH ±5% RH

DIGITAL OXYGEN DISPLAY / SERVO CONTROLLED OXYGEN (OPTIONAL) Oxygen Control Range 21% to 65% Oxygen Display Accuracy Of Full Scale ± 2% Oxygen Control Accuracy (100% Calibration) ± 3% Oxygen Control Accuracy (21% Calibration) ± 5% Oxygen Display Resolution 1% SCALE (OPTIONAL) Weight Range Weight Display Resolution Weight Accuracy 300 g to 8 kg 1 g ±10 g Operating Environment 20 to 30 C Temperature Air Velocity 10 to 95% RH Up to 0.1 m/sec SpO2 with HAEMODYNAMIC MONITOR (OPTIONAL) Parameters SpO2, PR, PI, PVI, SpCO, SpOC, SpMet, SpHb Mesurement Range 0 to 100 % Perfusion Index 0.02 20% Haemo parameters on External screen PR, NIBP, SpO2, Temp, EtCO2 STORAGE/SHIPPING INFORMATION Temperature -25 to 60 C Humidity 848 442 0 to 95 % RH 848 479.9 479.9 07 188.5 1390.9 872 251 477.6 1461 188.5 872 282 1261 282 381 876 540 876

2018 OKUMAN Medikal Sistemler A.S. All rights reserved. Technical specifications are subject to change by OKUMAN without prior notice. OKUMAN Medikal Sistemler A.S. Kazım Karabekir Caddesi 95/95 06060 Iskitler Ankara / TURKEY T: +90 312 384 05 20 F: +90 312 384 19 75 info@okuman.com.tr Catalog No: OKM 801-003-04-2018-EN