OKM 801 INFANT INCUBATOR 02 OKM 801 Infant Incubator Premature and / or infants which might have serious health problems after delivery they need close caring of the physician and the nurses because they are not capable to keep their body temperature at the required level and stability by their own. Besides the medical cure, in order to improve health conditions; patients need a fresh air in a steril environment with constant temperature and appropriate humidity as well as silence which do not interrupt their sleep. Also have optional Haemodynamic monitoring features alongwith additional external display. Simple viewing of all modes and applicable set values of the parameters. OKM 801 Infant Incubator is specially designed with high technology to meet all necessary requirements and makes difference in NICU.
Stable With ambient temperature probe OKM 801 infant incubator is able to compare the difference between ambient and setting temperature, and changing heating power output accordingly in order to provide more stable inside hood air temperature. The micro processor controlled unit has automatic Self test function. Skin temperature monitoring through Reusable & Disposable sensor Air circuit temperature monitoring More accurate temperature control and safer system Temperature 1 Connector Temperature 2 Connector Minimize Temperature Uniformity OKM 801 incubator s air circuit system is designed based on massive experimentation. With plenty aerodynamics knowledge the temperature uniformity is improved as much as possible in order to give infant the safest micro-environment. Allows the temperature to be monitored on two different (T1 and T2) points of the body for more accuracy to maintain targeted temperature level. Super Quiet Design It is approved that in addition to the direct auditory effects of noise, noise also influences the cardiovascular system, the respiratory system, sleep patterns, and stress levels of neonates. OKM 801 provides newborn a super quiet environment, hood sound is reduced to 45dB. Detachable Sensor Module Sensor module is connected with incubator main body 20 pin connector. During maintenance and service it can be removed easily. Three Channel Temperature Sensors There are three channel of temperature sensors in the module box. One channel is for reading hood temperature to remain the temperature at setting value. Another temperature sensor is used to compare the reading with other two sensors. If the reading of three sensors differ from 0.8 C, alarm is triggered. OKM 801 with External Screen/ Haemodynamic Monitor Humidity Sensors Humidity sensor is for reading humidity level in incubator. When the water level is low in the autoclavable water reservoir, an audible and visual Low Humidity alarm occurs. Oxygen Sensors (Optional) The oxygen control system adjusts the flow of oxygen within the incubator hood with a valve and an oxygen sensor module. The sensor module has two independent oxygen fuel cells. When the sensor module is outside of the hood during Oxygen Control mode, audible and visual alarms are enabled, and the flow of oxygen is interrupted. Temperature and Humidity Sensor Oxygen Sensor (Optional) 03 Backup Battery OKM 801 is equipped with backup battery, once power supply is off, the backup battery supports the air circuit and alarm system to keep working at least 30 minutes. Also external monitor with haemodynamic parameters will have a separate power backup.
8 Color LCD Touchscreen display provides all incubator parameter users to operate soft buttons as well as touchscreen Touchscreen OKM 801 Infant Incubator 04 Can be operated from both side of hood Ergonomic designed handle with perfect height 1,5 liter water reservoir enables OKM 801 to keep running for 36 hours. Big storage drawers Detachable water reservoir, easy to clean and sterilize Three auxiliary power output Optional Height Adjustment Haemodynamic Monitor with essential Incubators parameters. Tente castor with lock
Other Features / Air Curtain While the front or back access panels open, the air circuit motor rotation rate is accelerated automatically. Therefore more warm air is delivered to the hood. It effectively prevent heat lose and provide infant stable micro-environment. Haemodynamic Monitor Double Wall Design Air Curtain Alarm Audio & Visual Display Temperature Monitoring and Protection Alarms OKM 801 infant incubator monitor and control temperature on various points on heating system to ensure accuracy and safety. The alarms will be actived if any unmoral phenomenon is monitored. High Skin Temperature Low Skin Temperature High Skin 1 Temperature High Skin 2 Temperature Skin Probe Disconnect High Air Temperature Low Air Temperature Electronic circuit fault as High Temperature Cut Out Sensor Monitoring Alarms OKM 801 incubator monitors the condition of air, humidity, oxygen sensors, air flow probes and sensor box to ensure all the data collected are true and accurate. Alarms are triggered when any errors related to the operation of the sensors are detected. Humidity Heater Failed Add water Low Humidity (moisture) Reservoir Out Of Position Oxygen Cell Difference Low Oxygen Ratio High Oxygen Ratio Check O2 Supply Servo O2 System Fail Change Oxygen Cells High Spo2 alarm Low Spo2 alarm External display failure alarm Separate Haemodynamic parameters failure alarms Working Condition Monitoring Alarms In order to keep proper running and provide the best user ecperience, OKM 801 infant incubator monitors the working condition of each aspect. 05 Motor Failed Power Failure Stuck Key Sensor Module Failure Sensor Disconnect Low Air Flow Air Flow Probe Failed Battery Disconnect Sensor Out of Position Access Panel Open Heater Failed Air Probe Failed Skin1 Probe Fail Alarm SpO2 sensor Fail Alarm Watchdog Failed
GENERAL SPECIFICATIONS Height 126.1cm to 146.1cm Tubing Access Ports 10 Width 99.7 cm Access Door Size 18x13 cm (Max. 6 doors) Depth 57.7cm Mattress to Hood Height 48.0 mm Weight 80 kg Soft Bed Mattress Size (Bed safety mechanism Package Dimensions 107*68*155 cm active when pulled outside) X-Ray Tray 41 x 38.9 cm Trendelenburg ±12 3100 cm2 standard (upto 77 x 40cm/ 3080cm2 on request) 06 TEMPERATURE CONTROL MODES OKM 801 Infant Incubator External Display for Incubator & Haemodynamic parameters (Optional) Power Supply and Frequency Temperature Control Modes Air Mode Control Temperature Range Air Mode Control Override Temperature Range Air Mode Control Accuracy Skin Mode Control Temperature Range Heat Cut of Temperature 8, 10 or 12 inches colour TFT 100-240 VAC and 50/60 Hz Hood cover opening Display of Parameters Trend Display Air Filter (Replacable) Skin and Air Temperature Control Modes 20 C-37 C 39 C-40 C ±1.0 C 34 C-37.5 C 40 C ± 0.8 C 180 (Both Front & back) Active & set values 2,4,8,12,24 Hours Min. 0.3 to Max. 0.5 macron Skin Mode Control Override Temperature Range Skin Temperature Accuracy Dual-Skin Temperature Monitoring 37.5 C-39 C ±0.3 C Yes PERFORMANCE Air Flow Velocity Across Mattress Temperature Rise Time At 22 C (72 F) Ambient < 10 cm/sec <20min (From 22 C, 50% RH, to 35 C) Temperature Variability < 0.5 C Temperature Overshoot < 0.5 C Maximum Temperature Uniformity With A Level Mattress < 0.8 C Operating Noise Level In Hood 45dBa Carbon Dioxide (Co2) Level <0.5% SERVO HUMIDITY (OPTIONAL) With AutoClean Function of Autoclavable Chamber Humidity Control Range Humidity Control Operating Time Without Refilling Humidity Control Reservoir Capacity Humidity Display Accuracy Humidity Control Accuracy 30% - 95% RH 24 hours 1500 ml ±5% RH ±5% RH
DIGITAL OXYGEN DISPLAY / SERVO CONTROLLED OXYGEN (OPTIONAL) Oxygen Control Range 21% to 65% Oxygen Display Accuracy Of Full Scale ± 2% Oxygen Control Accuracy (100% Calibration) ± 3% Oxygen Control Accuracy (21% Calibration) ± 5% Oxygen Display Resolution 1% SCALE (OPTIONAL) Weight Range Weight Display Resolution Weight Accuracy 300 g to 8 kg 1 g ±10 g Operating Environment 20 to 30 C Temperature Air Velocity 10 to 95% RH Up to 0.1 m/sec SpO2 with HAEMODYNAMIC MONITOR (OPTIONAL) Parameters SpO2, PR, PI, PVI, SpCO, SpOC, SpMet, SpHb Mesurement Range 0 to 100 % Perfusion Index 0.02 20% Haemo parameters on External screen PR, NIBP, SpO2, Temp, EtCO2 STORAGE/SHIPPING INFORMATION Temperature -25 to 60 C Humidity 848 442 0 to 95 % RH 848 479.9 479.9 07 188.5 1390.9 872 251 477.6 1461 188.5 872 282 1261 282 381 876 540 876
2018 OKUMAN Medikal Sistemler A.S. All rights reserved. Technical specifications are subject to change by OKUMAN without prior notice. OKUMAN Medikal Sistemler A.S. Kazım Karabekir Caddesi 95/95 06060 Iskitler Ankara / TURKEY T: +90 312 384 05 20 F: +90 312 384 19 75 info@okuman.com.tr Catalog No: OKM 801-003-04-2018-EN