OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

Similar documents
U tube models PTU 09, 12, 15, 25, 30, 35, 40, 45. single linear tube models PTS 09, 12, 15, 25, 30, 35, 40, 45

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

WARNINGS. Nortek Global HVAC (UK) Limited, Fens Pool Avenue, Brierley Hill, Doc West No. Midlands, Page DY5 1QA 1 of 60. Part No.

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VSX RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR REZNOR VISION VS RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VSX RANGE OF RADIANT TUBE HEATERS

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VISION VS RANGE OF RADIANT TUBE HEATERS

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS INSTALLATION AND OPERATING MANUAL

Herringbone Linked Flue System

BENSON LINEAR RADIANT TUBE

ASSEMBLY, INSTALLATION & SERVICING MANUAL FOR AMBIRAD VSXUS INFRA-RED HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

Model VSUS & VSLUS 120V 60Hz Gas-Fired, Tubular, Radiant, Low-Intensity Infrared Heater

AMBIRAD VISION SCHOOL HEATER KIT INSTALLATION MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

INSTALLATION AND OPERATION INSTRUCTIONS Double Linear OVERHEAD RADIANT TUBE HEATERS Models: PTDSL 15, PTDSL 25, PTDSL 30, PTDSL 35, PTDSL 40, PTDSL 45

HERRINGBONE HB COMBINED FLUE SYSTEM

AMBIRAD.... Vision Radiant Tube Heating Systems...

INSTALLATION AND OPERATION INSTRUCTIONS OVERHEAD RADIANT TUBE HEATERS

ASSEMBLY INSTRUCTIONS - NXS SERIES. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

AMBIRAD QUARTZ GLOW INSTANT INFRA-RED HEATERS INSTALLATION AND OPERATING MANUAL

TEMPRA. Wall Mounted Fan Flue System boiler. Wall mounted fanned flue boiler INSTALLATION AND USE INSTRUCTIONS. Appr. nr. B A - CE 0063 AQ 2150

INSTALLATION AND OPERATING MANUAL. Vision VS Radiant

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

MULTIPOINT FF Room Sealed Fan-Assisted Water Heater

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

NOR-RAY-VAC CONTINUOUS RADIANT TUBE SYSTEM INSTALLATION AND OPERATING MANUAL

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Model: AC-108. Instruction Manual

Model No: Little Devil II (inc ss)

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

SURFACE WARM CEILING HEATERS

AB RANGE GAS FIRED ROOM SEALED AIR CURTAIN INSTALLATION AND OPERATING MANUAL

60" Tulle PatioTM. Instruction Manual. A Kichler Select ceiling fan

CARVER CASCADE 2 & CASCADE 2 GE CARAVAN WATER HEATER INSTALLATION INSTRUCTIONS LEAVE THESE INSTRUCTIONS WITH THE USER

Installation and Maintenance

INSTALLATION INSTRUCTIONS

52 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Installation and Maintenance

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

Technical and Dimensional Data. Saf-T Vent SC Plus

Vortex 15/21 Utility and Outdoor Module Vortex Combi 21 and Outdoor Vortex Combi 21

LIGHTING CAUTION NEW LISMORE 9 ARM CHANDELIER W 110V

Installation and Maintenance

ATMOSPHERIC GAS BOILER INSTALLATION, OPERATING AND MAINTENANCE MANUAL

42 Kevlar. Instruction Manual. Kichler Lighting 7711 East Pleasant Valley Road P.O. Box Cleveland, Ohio

NOTICE: The information contained on the following page(s) was produced prior to May 1, On that date Reznor became part of Nortek, Inc.

Alpha CombiMax 350 and 600

D100, D125 & D150. Installation Instructions

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Two Stage Pull Through System (Negative Pressure)

SUBMERSIBLE DIRTY WATER PUMP

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

Compact. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

LED. 60 StarkkTM. Instruction Manual. A Kichler Select ceiling fan

Select. Sutter PlaceTM. Instruction Manual. A Kichler Select ceiling fan

1. SAFETY RULES. 1. To reduce the risk of electric shock, insure electricity has been turned off at the circuit breaker or fuse box before beginning.

MRXBOX95B-LOFT. Mechanical Ventilation Unit with Heat Recovery & Summer Bypass for Loft Mounting. Installation and Maintenance

Fillmore Small Pendant Assembly and Installation Instructions

Contents. Version 004 infra_calor D shape U Australia 43/13 Technical specification subject to change

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single Stage Pull Through System (Negative Pressure)

MRXBOX95-LH1/LH2. Mechanical Ventilation Unit with Heat Recovery for Loft Mounting Installation and Maintenance. Spigot 4.

BWTC6510GL Cooker Hood 60 cm Glass cooker hood in stainless steel. BWTC9510GL Cooker Hood 90 cm Glass cooker hood in stainless steel

INSTALLATION INSTRUCTIONS FOR FLUE KIT

Blackheat HE. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. IP55 Protected Burner Box

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

GAS FIRED AIR CURTAIN AB 175, AB 225

MASTERTEMP HEATER REPLACEMENT PARTS

Installation and Wiring Instructions

READ AND SAVE THESE INSTRUCTIONS

GAS FIRED AIR CURTAIN AB 175, AB 225

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

54" Skye. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

INSPECT all combustion air openings into the building and, if necessary, clear as they become blocked by litter, dust, feathers or other matter.

52 CEILING FAN READ AND SAVE THESE INSTRUCTIONS FAN RATING AC 120V.

Lo-Carbon T-series Window & Roof Models

AD-24 Parts Manual 24 VAC Phase 7

Orrin. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

Ca 6s and BCa 6s kw INSTALLATION AND OPERATING INSTRUCTIONS. Page 1 31/07/00

60" Lyndon Patio. Instruction Manual Customer Service :30 AM to 5:00 PM EST, Monday - Friday A Kichler Decor ceiling fan

CEILING FAN OWNER'S MANUAL

INSTALLATION AND OPERATION INSTRUCTIONS. INFRARED RADIANT TUBE HEATER Single and Two Stage Pull Through System (Negative Pressure)

ECOSMART TWINFANS. (EST) 1 phase, Direct Drive, Run & Standby Fans for indoor use. Installation and Maintenance

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

AMBIRAD VISION VS RANGE RADIANT TUBE HEATERS SERVICING & COMMISSIONING MANUAL

STS-JZ (premierschwank) POSITIVE PRESSURE SERIES GAS FIRED INFRA-RED TUBE HEATERS

Part No. DOC 16 Rev. 09 December USER and INSTALLATION INSTRUCTIONS OUTDOOR MODULES 50/70, 70/90, 90/120 & 110/140

INSTALLATION OF DURAVENT POLYPRO SINGLE WALL POLYPROPYLENE VENTING SYSTEMS

GAS-ON-GLASS COOKTOP

ProStar Ceiling Fan PS52. Installation Instructions Instrucciones de instalación Instructions d installation

Wall hung combination boilers. This is a CAT II2H3+ appliance USER, INSTALLATION AND SERVICING INSTRUCTIONS SUPPORTED BY

Alpha CD13R,18R and 24R

C-IV 60 CEILING FAN READ AND SAVE THESE INSTRUCTIONS. FAN RATING AC 120V. 60Hz

Blackheat. Vacuum Assisted Linear, Double Linear, U-Tube, and Multi-Burner Gas Fired Heating Systems. Installation, Operation & Service Manual WARNING

Belling. Gas Hob GHU573 - GHU573T GHU70GE - GHU70TGE - GHU70GC GHU70TGC - GHU60GC INSTALLATION AND USER INSTRUCTIONS

Proline GAS HOB Model TCG40IX Instruction Book

BOILING PANS GAS & ELECTRICS

Electrician Installation Manual EM-E Ceiling Fan

Transcription:

OPTIM RDINT TUBE HETING SYSTEMS Operation, maintenance and servicing manual

CONTENTS GENERL INSTRUCTIONS Section Title Page 1. Preparing the Installation 4 2. Checking the Installation rea 5 3. Flue Connection & Ventilation Requirements 7 4. Fresh ir Ducted Inlets 9 5. Suggested Methods for Heater Suspension 10 6. Connecting Gas Supply 11 7. Connecting Electrical Supply 12 SSEMBLY INSTRUCTIONS Section Title Page 1. ssembling the Heaters 14 2. ssembling the Tubes 14 3. Insert Turbulators 15 4. Connect Return Bend 15 5. Fixing the Bracket and U-Bolts 16 6. Overshield Reflectors 17 7. Inner Reflectors 18 8. Outer Canopies 19 9. Fixing the End Caps 19 10. Fitting Burner and Fan 20 11. Fixing of End Moulds 20 12. Suspension of the Heater 21

3 GENERL INSTRUCTIONS

1. Preparing the Installation Standards mbi-rad Optima heaters must be installed in accordance with the following provisions and regulations. Gas safety (installation and use) regulation 1994. Health and Safety at work act 1974. IEE Regulations. Building standards (Scotland) consolidation regulations. BS5440: Prt 1, BS6891:1988 BS6896: 1991, BS6501: Part 1 1991 BS6500:1975 nd any other relevant British standard BS and codes of practice. These instructions are for use in the United Kingdom (GB) and Eire (IE) on natural gas (G20) at 20 mbar and propane (G31) at 37 mbar supplied pressure. 4

2. Checking the Installation rea Make sure the heater is far enough away from combustible materials (see Fig.1). There must be 1000mm clearance between any part of the heater and a wall. These minimum clearances must be maintained to help with the servicing of the burner. Ensure the suspension is sufficiently flexible to allow for thermal expansion (see Fig.5). ll heaters must slope towards the U-bend approximately 25mm. B E D D E C G Figure 1 BURNER MODEL TBLE 1 SE 11-15 16-20 21-25 26-28 29-33 34-35 36-38 DISTNCE FROM COMBUSTIBLES mm (50 C rise in temperature above ambient of a black surface) bove Fan DIM. 400 400 400 400 400 400 400 bove Canopy DIM.B 100 100 100 100 100 100 100 Below Reflector Edge DIM.C 1300 1490 1675 1820 2060 2160 2300 Horizontally to Side DIM.D 450 520 580 500 550 630 730 bove Canopy (inclined mounting) DIM.B 100 100 100 200 200 200 200 Below Reflector Edge (inclined mounting) DIM.C 1000 1200 1400 1500 1650 1760 1910 5

D J C B E Figure 2 G F E H B D Figure 2a B C D E F G H J Side Wall Canopy Induced Draught Fan Suspension Bracket Burner Burner Lid Obstacle above heater End Moulding 73580 Type Fan - Dim.80mm 76634 Type Fan - Dim.85mm 6

3. Flue Connection and Ventilation Requirements Optima heaters can be flued to atmosphere or remain unflued providing that the air supply and ventilation requirements within the building are complied to BS6896:1991. lso due consideration must be given to the possibilities of condensation forming on cold surfaces and glazing when using an unflued heater. Unflued Installation When installing the heaters unflued, ventilation requirements can be met by the following means: Natural Ventilation Forced Ventilation Natural Ventilation pertures must be fitted at high and low level with a maximum vertical distance of 3m between them. For High and Low level ventilation - where air change rate is less than 33m 3 /h per kw of total rated input of the heaters installed an aperture sized to the following criteria. 1.4cm 2 for each 1m 3 h per kw below 33m 3 per kw; or an aperture 52cm 2 /kw of total rated input of heaters. Natural Ventilation Where heat input is up to and including 60kW - ventilation should be 4.5cm 2 /kw of total rated input of the heaters. Where heat input is over 60kW - ventilation should be 270cm 2 plus 2.25cm 2 /kw in excess of the 60kW total rated input of the heater. Where apertures are unable to be installed for natural ventilation, ventilation needs to be supplied by means of a fan or blower to the following standard: Ensure minimum proven air flow is 33m 3 /h per kw of total rated input of the heaters. For more detailed information please contact mbi-rad s technical department. If the heater is installed without a flue ensure that combustion gases do not impinge on any surrounding combustible materials or glazing. (see Table 1). The maximum permitted temperature rise for such material is 50 C (Ref.BS7186).1989 For detailed information please refer to section 7 BS6896:1991, Installation of Gas Fired Overhead Radiant Heaters for Industrial and Commercial Heating (2nd and 3rd family gases). Flued Installation (See Fig.3) When Optima heaters are installed with a flue, a down draft diverter (B) must be fitted to the fan exit by means of screws and clamp plates provided. (This is supplied as an optional extra by the manufacturer). This diverter is designed to accept a 125mm (5in) nominal bore propriety twin wall metal flue pipe () which complies with BS715. Specifically for horticulture or green house applications where combustion gases can do harm, a square to round adaptor is fitted (E). Fit to the outlet of the fan by means of the clamp plates and screws provided (D). The joints should be sealed with heat resistant caulking and faced off with fire cement. 7

If single wall metal flue piping complying with BS715 1993 is used then an adaptor will be required. flue pipe should always be adequately supported at regular intervals from the building structure and terminated externally with a British Gas tested and certified terminal. The maximum flue length is 9m (30ft) and the maximum number of bends is 2. ll connections in the flue must be properly sealed. FLUE INSTLLTION WITH DOWN DRUGHT DIVERTER B D C E D FLUE INSTLLTION WITHOUT DOWN DRUGHT DIVERTER Figure 3 B C D E 125mm Bore Twin Wall Flue Down Draught Diverter Fan Clamp Plate Screws Square to Round daptor 8

4. Fresh ir Ducted Inlets ducted fresh air supply must be provided to the burner when Optima heaters are installed in locations where there is air born dust or where there is a polluted atmosphere e.g chlorinated vapours, process dust, foundry environments etc. How to fit a Fresh ir Supply (See Fig.4) Remove existing air intake grill from burner. Fit ducted air adaptor (D) to air inlet flange on the rear of the air intake chamber using the 2 captivated screws (G). ttach 100mm Ø flexible duct (C) to the ducted air adaptor (D) using the jubilee clip (B). ttach main 100mm Ø supply duct () to free end of flexible duct (C) with jubilee clip (B) Figure 4 Supply Duct - 100mm Ø B Jubilee Clip - 100mm Ø C Flexible Duct D Ducted ir daptor E Burner F End Moulding G Set Pins M5 x 60 9

5. Suggested Methods for Heater Suspension ttachment of the support chains to the support brackets should be made using speedlinks. Should drop rods be used a closed loop should attach the rod to the support bracket. Due llowance must be made for thermal expansion of the heater. The hanging attachments to overhead steelwork etc. must be purpose made to good sound engineering practice or of a proprietary type fixing. They must be adequately fixed and designed to carry the whole weight of the heater and to promote free movement due to linear expansion. In the event of suitable roof steel work not being available additional steel work should be fitted to enable vertical hangers to be used for suspending heaters. If there are any doubts as to the strength or suitability of roof steel work to which the heaters are to be suspended please refer to the consultant, architect, or owner of the building. D E 15 max 45 max 45 max B C C C C Figure 5 Speedlink B Shackle C Drop Rod with Formed Hook D Equal and opposite chain support when angle of inclination is greater than 15 E Vertical chain support when angle of inclination is less than 15 10

6. Connecting Gas Supply (See Fig.6) Gas connection is made by using a flexible metallic hose (F), tested and certified BS6501:Part1,1991. The connection is made to the 1/2 BSP male gas inlet connection on the burner assembly. The gas supply pipe (D) must terminate at each burner with the service cock (E). The gas union (G) must be fitted at each burner end between the service cock (E) and the burner gas inlet connection. It is necessary to form an expansion loop with the flexible metallic hose (F) to provide for linear thermal expansion of the heating system. Do not over bend the flexible hose. Elbows must be fitted to eliminate sharp bends near the end fittings. It must be in line without torsion or twisting. Jointing compound resistant to the action of liquid petroleum gas and natural gas should be used on all pipe threads. Under no circumstances should the gas controls of the burner be subjected to more than 50 mbar (20in.w.g) otherwise rupture of the control gas diaphragms and other damage will result. B C D E F G H J End Moulding Canopy Suspension Bracket Mains Gas Supply Pipe Service Cock Flexible Gas Hose Gas Union 90 Elbow Mains Lead 11 Figure 6

7. Connecting Electrical Supply (See Fig.7) Each component carrying an electrical supply must be earthed. 230 volt 50 Hz single phase supply is required. The electrical connection to the burners is made by means of 3 pin plug power connector. Live, neutral and earth connection should be made via a flexible supply cable to the power isolator and routed clear of the heater. The power isolator should be no further than 1m from the heater. The flexible cable should be 0.5mmØ. the current rating per burner is 0.55 amp (inductive). each burner must be fused externally at 3 amp. ll electrical work should be carried out to IEE Standards by a competent electrician. ll controls and switch gear must be rated to handle the total inductive load of the circuit they control. For large installations the use of relays or contactors should be considered. The method of connection to the electrical supply must ensure complete isolation and should be made via a fused double pole isolator, having contact separation of at least 3mm in all poles and supplying the appliance only. lternatively connection may be made via a 3 pin plug and switch shuttered socket both compiling with the requirements with BS1365. Typical External wiring Typical Internal wiring Figure 7 12

13 SSEMBLY INSTRUCTIONS

1. ssembling the Heaters ssembly - Stages - Check List The following are the key stages when assembling a 2 or 3 module Optima heater. Tube assembly Insertion of turbulators Fixing the return bend Positioning the bracket Fixing the U-bolts Fixing the overshield reflectors ssembling the inner reflectors ssembling the outer canopies Fixing the end caps Fitting the burner and fan Fixing the end mouldings 2. ssembling the Tubes 1. Support radiant tubes on blocks or trestles. 2. ssemble the 2 sections of the stainless steel firing leg () and (H) by means of pins (J). Ensure pins (J) are located in holes in the end of the first tube (). Note: Do not fully tighten pins (J) but fully tighten lock nuts (K). H K J 14

3. Insert Turbulators 1. Insert relevant turbulators depending upon the heater model. Heater Model Turbulators Insert at Location SE 11-15 UT 2 x 860mm (1) and (2) 2 Module 1 x 2600mm (3) SE 16-20 UT 1 x 976mm (1) 2 Module 2 x 2600mm (2) and (3) SE 21-25 UT 2 x 860mm (1) and (2) 2 Module 1 x 2600mm (3) SE 26-35 UT 1 x 976mm (3) 3 Module SE 36-38 UT 1 x 976mm (1) 3 Module 2 x 2600mm (2) and (3) 4. Connect Return Bend 1. Connect return bend (C) on to the tubes (H) and (G) wit the U-bend clamping bolts on top. (Fig 9) 2. Ensure the fixing pins on the heater tubes (for overshield location) are vertical. 3. Tighten the U-bend clamping bolts securely taking care not to over tighten. 15

2 Module Heater C B3 Location 1 H O B2 Location 2 B1 Location 3 3 Module Heater C Location 1 B4 B3 O Location 2 H B2 G B1 Location 3 R U Figure 9 16

5. Fixing the bracket and U-bolts 1. Slide the suspension bracket along the tubes into position (as shown in Fig 14) taking care not to damage the paint finish. 2. Eight U-bolts are supplied with the heater; two U-bolts are stainless steel and six are zinc plated. The two stainless steel U-bolts (M) are identified by having lock nut (L) and fixing nuts pre-fitted to each. 3. The stainless steel U-bolts are fitted to the firing tube () on brackets B1 and B2. Note: 3mm distance must be provided around the firing tube to allow thermal expansion on the 1st and 2nd stainless steel U-bolt. M M L L L B1 L B1 & B2 2 Module Units 3 Module Units 4. Position the four suspension brackets along the tube sets in the following intervals. (see Fig.14) 1st Bracket: (B1) 155mm is from the beginning of the tube with a loose fitting stainless steel U-bolt on the firing leg. Tighten the return leg U-bolt to maintain this position. 2nd Bracket: (B2) 1790mm from the 1st bracket. Tighten both U-bolts to maintain this position. 3rd Bracket: (B3) 1430mm from the 2nd bracket. Tighten both U-bolts to maintain this position. 4. Position the four suspension brackets along the tube sets in the following intervals. (see Fig.14) 1st Bracket: (B1) 155mm is from the beginning of the tube with a loose fitting stainless steel U-bolt on the firing leg. Tighten the return leg U-bolt to maintain this position. 2nd Bracket: (B2) 1785mm from the 1st bracket with a loose fitting stainless steel U-bolt on the firing leg. Tighten the return leg U-bolt to maintain this position. 3rd Bracket: (B3) 1795mm from the 2nd bracket. Tighten both U-bolts to maintain this position. 4th Bracket (B4) 1370mm from the 3rd bracket. Tighten both U-bolts to maintain this position. 17

2 Module Heater W 1430 Bracket CRS 1790 Bracket CRS 155 CRS V W 3 Module Heater 1370 Bracket CRS 1795 Bracket CRS 1785 Bracket CRS 155 CRS V W Figure 14 18

6. Overshield Reflectors 1. To attach the overshields on the heater tubes, first place washers (WS) onto fixing pins (N) before placing overshields (O) onto fixing pins. Place further washers (WS) onto fixing pins before securing with split pins (P). 2. Open the ends of the split pins after inserting them through the fixing pins (N). P WS O N WS 19

7. Inner Reflectors 2 Module Units 1. Place the 1st and 2nd inner reflectors (R) on the heater by sliding the reflectors between the tubes and the brackets. (Fig.9) 2. Overlap each reflector by 15mm and bolt together i.e. utilising the two slotted holes on the sides of each reflector and the single hole in the middle of the leading edge of the reflector. Bolt the 1st reflector to the 2nd reflector. Make sure that the 1st reflector sits on top of the 2nd. 3 Module Units 1. Place the 1st, 2nd and 3rd inner reflectors (R) on the heater by sliding the reflectors between the tubes and the brackets. (Fig.9) 2. Overlap each reflector by 15mm and bolt together i.e. utilising the two slotted holes on the sides of each reflector and the single hole in the middle of the leading edge of the reflector. Bolt the 1st reflector to the 2nd reflector to the 3rd reflector. Make sure that the 2nd reflector sits on top of the 1st and 3rd reflectors. 3. Insert reflector location bolts (X) through each side of the first bracket. the end of the bolts locate into the corresponding holes in the inner reflector. 4. Using the recommended safety equipment i.e. gloves, goggles and a face mask, cover the back of reflectors with the insulation mats. Tuck in the edge of the mat behind the lip of the reflector. 20

8. Outer Canopies 2 Module Units The outer canopies are made up of 4 identical half covers (U) which engage into the side of the inner reflectors and join at the centre by way of a closing plate which holds the two halves together. Install the outer canopies using the following method; 1. Slide on the two halves to cover the 1st section of the heaters and fit closing plates to each end (Y) to the second set of canopies. 2. Slide on two more outer canopies. 3. Stop short of the canopies already fitted and fit closing plates (Y). 4. Insert the ends of the second set of canopies inside the first set at the central joint. 5. slot (Z) is located 15mm from the end of each canopy. lign each slot i.e one on top of each other and insert M8 self tapping screws provided.(see Fig.13) 3 Module Units The outer canopies are made up of 6 identical half covers (U) which engage into the side of the inner reflectors and join at the centre by way of a closing plate (Y) which holds the two halves together. Install the outer canopies using the following method; 1. Slide on the two halves to cover the centre section of the heaters and fit closing plates to each end (Y). 2. Slide on two more outer canopies. 3. Stop short of the canopies already fitted and fit closing plates (Y). 4. Insert the ends of the second set of canopies inside the first set at the central joint. 5. slot (Z) is located 15mm from the end of each canopy. lign each slot i.e one on top of each other and insert M8 self tapping screws provided. 6. Repeat the procedure for 3rd set of outer canopies. 9. Fixing the End Caps 1. Insert the end cap (D1 and D2) into the end of the outer canopies making sure that the end cap engages inside the inner reflector before inserting eight securing screws and covering washers. D2 D1 Figure 10 Figure 11 21

10. Fitting Burner and Fan 1. ttach the burner and fan assembly and tighten securely by the use of a 4mm allen key. Note: The fan is fitted to the end of the black radiant tube and secured using the grub screw on the support spinning. Ensure fan discharges horizontally away from the burner if the system is unflued and vertically upwards if the system is to be flued or if end mouldings are to be fitted (see Fig.12 and section 2 of general instructions. Figure 12 11. Fixing of End Mouldings 1. If end mouldings have been ordered (optional item) fit the end mouldings with the screws provided to the holes in top of the canopy/end mouldings. When installing end mouldings with an Optima heater, the fan outlet must be positioned vertically upwards. flue guard is supplied to prevent ingress of foreign bodies into the fan when the heater is not working. G F E H B D 22

12. Suspension of the Heater 1. The heater must be suspended on all 3 of the brackets. On all 4 brackets if it is a 3 module heater (see section 5 in general instructions). ll U-tube heaters must be suspended with U-bend of the heater 25mm lower than the burner end. This procedure has been based on floor assembly of the heaters. The procedure can be undertaken in the roof area at the installing contractor s risk. 23

mbi-rad Limited Fens Pool venue Brierley Hill West Midlands DY5 1Q United Kingdom Telephone 01384 489700 Facsimile 01384 489707 Email info@ambirad.co.uk Website www.ambirad.co.uk is the registered trademark of mbi-rad Limited. Due to continuous product innovation, mbi-rad reserves the right to change product specification without due notice. Document reference number : GB/SE/053/0506