PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Similar documents
PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS.

Silhouette Installation and Wiring Instructions

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra Centrifugal Fan

Centrif Duo & Centrif Duo Plus

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS.

Lo-Carbon Quadra SELV

Lo-Carbon SELV Tempra

Lo-Carbon Quadra Centrifugal Fan

Lo-Carbon SOLO Plus SELV Centrifugal Bathroom/Toilet Fan

Lo-Carbon MULTIVENT MVDC-MS & MVDC-MS H VENTILATION SYSTEMS V~50Hz. Installation and Wiring Instructions IP22. Stock Ref.

EKF. EC kitchen extract fan range. Installation and Wiring Instructions. Stock Ref. N EKF355E1 EKF400E1 EKF450E1 EKF450E3 EKF500E3 EKF560E3

Vent-Axia Svara Multifunctional app controlled fan. Important Information 2 Installation and Wiring Instructions 3-11 Accessories 12 Pin Code 12

VA100 SELV 12 RANGE. Installation and Wiring Instructions IPX7

Lo-Carbon T-series Window & Roof Models

SUPER T WALL FANS. Installation and Wiring Instructions

VA 150 A, VA 150 P WINDOW EXTRACT FAN. Installation and Wiring Instructions V/1/50Hz

Installation and Wiring Instructions

T-SERIES. Wall & Panel Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

T-SERIES. Window & Roof Models. Installation, Set-up and Operating Instructions. 230V/1/50Hz

INTEGRA PLUS ABC. 230V~ 50Hz. Stock Ref. N. Installation and Wiring Instructions IPX2

EXTRACTOR HOOD. Please read all the instructions carefully before starting the installation. 230 / 240V 50Hz

HR200WK Through the wall Heat Recovery Ventilator

READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

Integra. Integra Plus EC MVHR. Installation & Commissioning. Stock Ref. N EC Integra Plus EC PLEASE RETAIN THESE INSTRUCTIONS WITH THE PRODUCT.

Long Case Axial Fan. Installation and Wiring Instructions V/1/50Hz & V/3/50Hz

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Trimbox Mixed Flow Fans. Product Manual. ventilation systems TP220T TP221T TP222T TP223T

Simply Silent Contour 4 (100mm) Axial Extraction Fan

PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH THE ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS

Installation & Operating Instructions

DUCT AIR HEATER WITH BUILT-IN CONTROLS. Installation & User Instructions. Stock Ref T T T3

ELIX 1003 IPX4. Energy Efficient Centrifugal Fan with EC Motor Installation and Operating Instructions

Lo-Carbon PoziDry Pro

IF IN DOUBT, INSTALLATION SHOULD BE MADE BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH CURRENT WIRING REGULATIONS.

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

CI/SfB (57.7) 1st Edition. Lo-Carbon Response/SELV dmev Unit. A new generation of Lo-Carbon continuous running fans

Xpelair Simply Silent TM Contour Fan

ELEGANCE IPX4 IPX7. Low Carbon Fan with EC Motor Installation and Operating Instructions. 6 models:

Purge Ventilation Unit. Product Manual. ventilation systems TP625

Warnings, Safety Information and Guidance

Internal/External Wall/Window Fan Range GX6. Installation and maintenance instructions Retain for future use

Installation & Operating Instructions

Xpelair Simply Silent TM DX100 Fan

Xpelair Simply Silent DX150

irconcentre.co.uk airooncentre.co.uk

"WHHR125DC" Whole House Heat Recovery Unit with Low Energy DC Motor. Installation, Operating and Maintenance Instructions domestic and commercial use

LV100 Standard LV100PC Pull Cord LV100T Timer LV100H Humidistat LV100HP Humidistat and Pull Cord LV100PIR

Hand Dryer Installation & User Manual

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

Xpelair Simply Silent DX100

CI/SfB (57.7) 1st edition

Sentinel Kinetic MVHR RANGE

CI/SfB (57.7) 3rd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

CLASSIC-100. Instruction leaflet. Instruction leaflet

"Microbox" DC Models MBOX 125/2DC MBOX 125/2DC204

Xpelair Simply Silent DX100B

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

WHHR Midi & Midi Lite

PUREAIR SENSE. Instruction Manual. A product by. B at hroom Fan wi t h O dour Sen se Tec h n ology Vent-Axia PureAir Sense F&W Manual.

Sentinel. Kinetic MVHR and Kinetic Plus MVHR. Operation & Monitoring. Stock Ref. N

Turbo Inline Fan, White - Non Illuminated Art no.33500

DESIGNER HOOD MODEL: EH-E9122ST(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Titon CME1 Q Plus Mechanical Extract Ventilation Unit

SLIMAIRE 230V & 12V SINGLE SPEED FANS

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

SAX. Window & Wall Fans

PROZONE INSTALLATION AND OPERATING INSTRUCTIONS FOR UK-PR ISS-B

GEH9026G Cooker Hood

White - Non Illuminated Art no White - Cool White LED Art no.32600

Unity CV2GIP Decentralised Mechanical Extract Ventilation (dmev) Installation Instructions

Stainless Steel Chimney Extractor

Wind. Service instruction

nergybulbs.co.uk Domestic AC Fans 230V Installation and Operating Guide Quick Order Hotline or

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

AXIAL FANS USER S MANUAL

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

HOTLINE:

BATHROOM EXTRACT FANS SILENT-100 Series

CMX-S. Company name: Contact: Tel: Central Mechanical Extract Ventilation (cmev) appliance. Installation and Operating Instructions

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

Installation and Maintenance

CI/SfB (57.7) 1st Edition. Vent-Axia Sentinel Kinetic Horizontal Range. Vent-Axia MVHR Units

CG60/ 70/ 80/ 90/ 100 SS/BK

HR100R. Mini Air Handling Unit - For Ducted Ventilation With Heat Recovery. Installation and Servicing Instructions

CI/SfB (57.7) 2nd Edition WINNER2011. Winners of the Energy Efficiency Initiative 2011 Award with our Lo-Carbon Continuous Ventilation Product Range.

SPLASHPROOF AXIAL EXTRACT FANS USED TO EXTRACT AIR EITHER DIRECTLY TO THE OUTSIDE OR INTO DUCTING UP TO 4m LONG

LEIHDC70SC - LEIHDC70BB LEIHDC70BC. Instructions Manual.

60cm Integrated Turbo Extractor

Belling Cooker Hood User Manual

D100, D125 & D150. Installation Instructions

The UK s Leading Ventilation Company. Lo-Carbon Revive. 2nd Edition.

Titon HRV1 Q Plus HRV1.5 Q Plus HRV2 Q Plus Heat Recovery Ventilation Units

Stainless Steel T-Box Extractor

Stoves Cooker Hood User Manual

Stainless Steel Chimney Extractor

Transcription:

Silhouette Lo-Carbon RANGE 100/150mm AXIAL EXTRACT FAN Installation and Wiring Instructions Stock Ref. N 44 16 24-100B 44 16 25-100T 44 16 26-100HT 44 16 28-150B 44 16 29-150T 44 16 30-150HT 220-240V~50Hz PLEASE READ INSTRUCTIONS IN CONJUNCTION WITH ILLUSTRATIONS. PLEASE SAVE THESE INSTRUCTIONS. IPX4

Installation and Wiring Instructions for the Lo-Carbon Silhouette Range of Extractor Fans. IMPORTANT: READ THESE INSTRUCTIONS BEFORE COMMENCING THE INSTALLATION DO NOT install this product in areas where the following may be present or occur: Excessive oil or a grease laden atmosphere. Corrosive or flammable gases, liquids or vapours. Ambient temperatures higher than 40 C or less than 5 C. Possible obstructions which would hinder the access or removal of the Fan. SAFETY AND GUIDANCE NOTES A. All wiring to be in accordance with the current I.E.E. Regulations, or the appropriate standards of your country and MUST be installed by a suitably qualified person. B. The Fan should be provided with a local isolator switch capable of disconnecting all poles, having a contact separation of at least 3mm. C. Ensure that the mains supply (Voltage, Frequency, and Phase) complies with the rating label. D. The Fan should only be used in conjunction with the appropriate Vent-Axia products. E. The fan should only be used in conjunction with fixed wiring. F. When the Fan is used to remove air from a room containing a fuel-burning appliance, ensure that the air replacement is adequate for both the fan and the fuel-burning appliance. G. The Fan should not be used where it is liable to be subject to direct water spray for prolonged periods of time. H. Where ducted Fans are used to handle moisture-laden air, a condensation trap should be fitted. Horizontal ducts should be arranged to slope slightly downwards away from the Fan. I. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. J. Children should be supervised to ensure that they do not play with the appliance. K. Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. L. The exterior grille should be at least 2.3m above the ground to prevent people from being able to access moving parts. If the external grille is positioned between 0-2.3m from the ground, Please use the Vent-Axia wall kit as detailed below to ensure people cannot access the fans impeller from the outside. DESCRIPTION The Lo-Carbon Silhouette 100mm fan is an axial extraction fan suitable for domestic bathrooms and W.C s. The Lo-Carbon Silhouette 150mm fan is an axial extraction fan suitable for domestic kitchens and utility rooms. They are available as wall or panel mounted models with shutter timer and humidity combinations. Long life ball bearing DC motor with anti-vibration mounts provides low noise transmission into plasterboard/panels for silent operation. The fan can be wall or panel/ceiling mounted. ACCESSORIES (not supplied) WALL FITTING KIT A range of 100mm and 150mm wall kits are available for installing into most walls using telescopic liners supplied. Stock Reference White Brown 100 254102 254100 150 140902A 140903A 2

A. INSTALLATION IMPORTANT: The fan should only be used in conjunction with fixed wiring. PANEL/CEILING MOUNTING 1. For panel/ceiling mounting the fan should be installed into a closed duct system of at least 1.2m long (max 3m) or protected by an exterior air grille that must comply with the standard requirements of your country to prevent access to the fans impeller. 2. Cut a 105mm diameter hole for 100mm fans or a 155mm diameter hole for 150mm fans. 3. Loosen the screw at the bottom of the grille and remove the front grille. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. 4. Attach ducting as required for the installation. 5. Wire the fan as described in Section B-Wiring. Adjust any settings as required (see Section C-Setup). 6. Replace the grille and tighten the retaining screw. 7. After installation, ensure impeller rotates freely and the shutters can open. WALL MOUNTING 1. For wall mounting either cut a 117mm diameter hole for 100mm fans or a 170mm diameter hole for 150mm fans, through the wall and insert the wall sleeve. Slope the sleeve slightly downwards away from the fan. Cut to length and cement both ends into position flush with the wall faces. 2. Loosen the screw in the bottom of the grille and remove the front grille. Mark the screw centres through the holes in the fan back plate. Drill, plug and screw into position. Fix exterior grille into position with the louvres positioned downwards. (Note:- The grille must comply with the standard requirements of your country to prevent access to the fans impeller. The wall kit used in this installation should provide a minimum ducting length of 100mm from the fans back plate to the inside of the external grille). 3. Wire the fan as described in Section B-Wiring. Adjust any settings as required (see Section C-Setup). 4. Replace the grille and tighten the retaining screw. 5. After installation, ensure impeller rotates freely and the shutters can open. B. WIRING. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. IMPORTANT The fan should only be used in conjunction with fixed wiring. The cross - sectional area of supply cord used should be ranged from 1-1.5mm 2. Cable entry can only be made from the rear of the fan. The extraction fan is suitable for connection to 220-240V 50Hz supply. 3

The fan is a class ll double insulated product and MUST NOT be earthed. 1. Select and follow the appropriate wiring diagram. (Fig. 2 or 3) 2. Check all connections have been made correctly and ensure all terminal connections and cable clamps are securely fastened. 3. Ensure the impeller rotates and is free from obstructions. C. SETUP WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE. ACCESSING THE CONTROL SETTINGS (Fig. 4) 1. Loosen the screw in the bottom of the grille and remove the front grille. 2. Carefully pull the inner cap from the centre of the fan away from the chassis. 3. Adjust the settings as outlined below. SPEED SETTING: BEFORE SETTING THE SPEED, SWITCH OFF THE MAINS SUPPLY. SPEED SHOULD ONLY BE SET BEFORE OR DURING INSTALLATION. The fan has two speed settings for different installation requirements: 1) High speed: T and HT models: Dip switch 2 in the OFF position. (Fig.5 and right) 100B/150B models: Remove jumper (Fig.5) ON 1 2 High speed (T/HT) 2) Low speed (Factory set): T and HT models: Dip switch 2 should be in the ON position. (Fig.5 and right) 100B/150B models: Replace jumper. (Fig.5) Dip switch 1 should be in the OFF position (T and HT models only). ON 1 2 Low speed (T/HT) TIMER ADJUSTMENT (T AND HT MODELS) BEFORE ADJUSTING THE TIMER, SWITCH OFF THE MAINS SUPPLY. TIMER SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 1. Remove the fan grille. The controller is factory set at 15 minutes approx. The overrun time period can be adjusted from 1-30 minutes by altering the adjuster on the control PCB. 2. To REDUCE the operating time, use a small screwdriver to turn the adjuster Fig.5. CLOCKWISE. 3. To INCREASE the operating time, use a small screwdriver to turn the adjuster Fig.5. ANTI-CLOCKWISE. 4. Replace the fan grille. 4

HUMIDITY SET-POINT ADJUSTMENT (HT MODELS ONLY) BEFORE ADJUSTING THE CONTROLLER, SWITCH OFF THE MAINS SUPPLY. HUMIDISTAT SHOULD ONLY BE ADJUSTED BEFORE OR DURING INSTALLATION. 1. Remove the fan grille. The controller is factory set to switch on at about 70% RH. The humidity set point can be adjusted from 65-95%RH by altering the adjuster on the control PCB. 2. To LOWER the set-point use a small screwdriver to turn the adjuster Fig.5. ANTI-CLOCKWISE. This makes the controller MORE sensitive. 3. To RAISE the set-point use a small screwdriver to turn the adjuster Fig.5. CLOCKWISE. This makes the controller LESS sensitive. 4. Replace the fan grille. D. SERVICING AND MAINTENANCE. WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE POWER SUPPLY DURING MAINTENANCE. 1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build up of dirt or other deposits. 2. Wipe the inlets and front face with a damp cloth until clean. The fan has sealed for life bearings, which do not require lubrication. Fig.1. 5

Fig.2 Models: 100B/150B, 100HT/150HT (Timer not used) 1 PHASE SUPPLY (220-240V 50Hz). N ~ L FUSE N L SWITCHED FUSED SPUR Fan Fig.3 Models: 100T/150T, 100HT/150HT LS N L ~N Fan FUSE Fig.4. Accessing the control settings Fig.5. Timer adjustment Humidistat adjustment Speed adjustment Jumper for 100B/150B models Head Office: Fleming Way, Crawley, West Sussex, RH10 9YX. Tel: 01293 526062 Fax: 01293 551188 UK NATIONAL CALL CENTRE, Newton Road, Crawley, West Sussex, RH10 9JA SALES ENQUIRIES: Tel: 0844 8560590 Fax: 01293 565169 TECHNICAL SUPPORT: Tel: 0844 8560594 Fax: 01293 532814 For details of the warranty and returns procedure please refer to www.vent-axia.com or write to Vent-Axia Ltd, Fleming Way, Crawley, RH10 9YX 442295F 0811 6