Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Similar documents
Operation Manual Portable Room Air Conditioner Models: RPC35WA and RPC41WA

2.9kW Portable Air Conditioner

Customer Operation & Installation Manual Electric Panel Heaters

2.9kW Portable Air Conditioner

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

20L Electronic Dehumidifier

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

General Care and Safety Guide

Operating Instructions

PANEL HEATER OPERATING INSTRUCTIONS. For Models: CELEPANEL, CELEPANELT

PANEL HEATER OPERATING INSTRUCTIONS. For Model: CELEPANELD

General Care and Safety Guide

Ceramic Wall Heater With Remote

FAN HEATER FH118 User Manual

Electronic Ceramic Tower Heater

General Care and Safety Guide

Operating Instructions. Oil Column Heater. Models: GOC155, GOC157, GOC1511

General Care and Safety Guide

Dual-Hose Portable Air Conditioner User Manual

Platinum Series Electronic Panel Heaters

Koolbreeze. Portable Air-conditioner User s Manual. For Model : CLIMATEASY 14 P14HCP. Downloaded from manuals search engine

80cm Tower Fan With Remote Control

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Convection Panel Heater

Local air conditioner

OSCILLATING FAN HEATER INSTRUCTION MANUAL

AVAC9000W Portable Air Conditioner with 24 hour timer Installation Instructions and User Guide

10L Evaporative Cooler with Timer

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

PANEL HEATER OPERATING INSTRUCTIONS. For Models: TWFP10000, TWFP PK

EH0554 Indoor Climate Control

Portable Room Air Conditioner and Heat Pump

EH0533 Indoor Climate Control

General Care and Safety Guide

7Litre Evaporative Cooler With Remote

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

PORTABLE AIR CONDITIONER

BAR FRIDGE 118 & 228 LITRE

AC-12200E Portable Air Conditioner

1500W CERAMIC HEATER. Instruction Manual

15,000 BTU Portable Air Conditioner

IMPORTANT SAFETY INSTRUCTIONS

Instruction Manual. Model: EPA 16 Portable Airconditioner

IMPORTANT SAFETY INSTRUCTIONS

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

Convection Panel Heater

PRODUCT MANUAL OPERATION, INSTALLATION AND MAINTENANCE MANUAL. Indoor Convective Panel Heater

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

Radiant Heater. Instruction Manual QH-200 N13275

Flueing Installation Manual

Portable Air Conditioner Instruction Manual

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

2200W RADIANT HEATER GVARH350. Instruction Manual

AE2400 Elite Series Ceramic Tower. Instruction Manual

Reverse Cycle Portable Air Conditioner with Dehumidifier

Portable Air Conditioner

Oil-filled Radiator NY23EC-11L User Manual

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

THERMOFILM CONVECTIVE PANEL HEATER INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Models: CP 2400 CP 2000 CP 1500 CP 1000 TABLE OF CONTENTS

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

20L/D DEHUMIDIFIER Model Number: IG9800

Operating Instructions. 9.0L Mini Oven. Item No: FMO100

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

OWNER S MANUAL. Portable Air Conditioner. Product defect? Not working properly? DO NOT return this product to the store where you purchased it.

USE, CARE AND INSTALLATION INSTRUCTIONS FOR YOUR NEW CANNON HORIZON HEATER

Levanté. Electric Panel Heater. Operating & Installation Instructions LPH15 LPH20.

PORTABLE AIR CONDITIONER

INSTALLATION & USER INSTRUCTIONS

Instruction Manual. Portable Air Conditioner

Instruction Manual Item No.: V~, 60Hz

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

WARRANTY BOOKLET. EHPA Electric Heat Pump Water Heaters. Register online at

2.4kW Ceramic Heater Model: DHCER24SW

Portable Air Conditioner

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

all-rounder Mini Compact Bagless Vacuum Cleaner Cyclonic Bagless Technology Washable HEPA Filtration Compact, Lightweight & Stylish Design all-rounder

10cm Desk Fan User Manual

Curved Metal Panel Heater

READ AND SAVE THESE INSTRUCTIONS

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

AC Portable Air Conditioner AC-14100E, AC-14100H OWNERS MANUAL. Read and save these instructions.

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

OWNERS INSTRUCTION MANUAL

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Sunbeam Tower Fan with Night Mode

40cm Pedestal Fan with Remote Control

PREMIUM BAR FRIDGE GMF119G & GMF229G. Important: Retain these instructions for future use 228 LITRE 118 LITRE

12L Dehumidifier Model: HG00923

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

WARRANTY BOOKLET. Hotflo (HFE) Series. Electric Storage Water Heaters. Register online at

Air Dehumidification System. Instruction Book CLI-DH8D

PORTABLE AIR CONDITIONER WITH HEATER ... WA-9061 H" 9,000 BTU WA H" 10,000BTU

Transcription:

HIGH MID LOW DRY FAN COLL HEAT TIMER SLEEP SWING Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA F C This appliance shall be installed in accordance with: Manufacturer s Installation Instructions Current AS/NZS 3000 Local Regulations and Municipal Building Codes including local OH&S requirements This appliance must be installed, maintained and removed only by an Authorised Person. For continued safety of this appliance it must be installed and maintained in accordance with the manufacturers instructions.

BEFORE PROCEEDING WITH THE OPERATION OF YOUR NEW RINNAI PORTABLE ROOM AIR CONDITIONER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS, FEATURES AND OPERATION OF YOUR NEW APPLIANCE. Rinnai 2 Portable Room AC OIM

TABLE OF CONTENTS Safety & Important Points 4 Warranty & Specifications 5 Unpacking the Appliance... 5 Warranty... 5 Specifications... 5 Air Conditioner Basics 6 Appliance Components... 6 Control Panel... 7 Basic Operation... 7 Basic Operation Control Panel... 7 COOL... 7 DRY (Dehumidifying)... 7 Operation 8 FAN... 8 SLEEP Function... 8 Care & Maintenance 9 General Maintenance... 9 Cleaning the Air Filter... 9 Save a Service Call... 10 When to Call for Service... 10 Installation 11 Location... 11 Duct Assembly... 11 Exhaust Ducting Options... 12 Window Installations... 12 Semi-Permanent Wall Installation... 13 Condensate Drainage... 13 Internal Condensate Tank... 13 Fixed Condensate Drainage Hose... 13 Contacts 16 Rinnai 3 Portable Room AC OIM

SAFETY & IMPORTANT POINTS IMPORTANT READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE. Always comply with the following precautions to avoid dangerous situations and to ensure optimum performance. Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, personal injury and/or death. WARNINGS: WHEN IGNORED, CAN RESULT IN SERIOUS INJURY OR DEATH. CAUTIONS: WHEN IGNORED, CAN RESULT IN MINOR INJURY OR PRODUCT DAMAGE. WARNING The appliance is fitted with an Australian flexible cord and 2 pin plug intended for connection to an Australian 10 Amp socket outlet. It is not suitable for connection in other countries or alternative power supplies. Ensure that the voltage and frequency of the power supply correspond to the ratings on the dataplate of the appliance. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Young children should be supervised to ensure they do not play with the appliance. DO NOT allow children or persons with reduced physical, sensory or mental capabilities to sleep directly in front of this appliance. DO NOT allow children to post articles into the louvres of the appliance. DO NOT use power boards or double adaptors with this appliance. DO NOT coil or bundle the electric cord to reduce it s length as overheating of the cord may occur which could result in a fire hazard. The flexible cord and plug must not be modified. If the cord or plug are damaged, they must be replaced by Rinnai or a Rinnai appointed service agent. DO NOT cover or place articles on or against any parts of this appliance, to avoid overheating. DO NOT sit on this appliance DO NOT use this appliance in the immediate surroundings of a bath, a shower or a swimming pool. DO NOT move this appliance whilst it is turned on. DO NOT unplug the appliance by pulling on the flexible cord. DO NOT handle any parts of this appliance, including the plug and flexible cord, with wet or damp hands. DO NOT immerse the appliance, flexible cord and plug in water or any other liquid. DO NOT place containers of any liquid or wax on top of this appliance. Turn off the appliance and unplug from the power socket outlet when not in use. DO NOT use in areas where flammable liquids are stored. This appliance is suitable for indoor use only. Never dismantle the appliance. Tampering with electrical connections and components is highly dangerous and may cause appliance malfunction, property damage, personal injury and/or death. Rinnai 4 Portable Room AC OIM

UNPACKING THE APPLIANCE If any damage is evident DO NOT INSTALL or OPERATE and contact your supplier for advice. WARRANTY The benefits to the consumer given by this warranty are in addition to all other rights and remedies of the consumer under a law in relation to the goods or services to which the warranty relates. Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. This appliance has a 2 year parts warranty from date of purchase. If the product fails within this 2 year period return it to the supplier with proof of purchase for repair or replacement. Supplier warranty claims for Rinnai products or services must be made by contacting Rinnai Australia. Contact details are on the back of this document. The following exclusions may cause the warranty to become void and may result in a service charge and costs of parts (if required): 1. Accidental damage and acts of God. 2. Failure due to abuse or misuse, improper maintenance, failure to maintain or improper storage. 3. Failure due to incorrect or unauthorised installations or outdoors use. 4. Failure or damage caused by alterations, service or repair work carried out by persons other than Rinnai service persons or service agents. 5. Where it is found that there is no fault with the appliance and the issue is related to the installation or is due to the failure of electricity supply. SPECIFICATIONS WARRANTY & SPECIFICATIONS MODEL RPC26WA RPC35WA RPC41WA Power Supply V/Hz 220-240~ / 50 Maximum Input Power W 1200 1600 2000 Dimensions - Net (H x W x D) 798 x 475 x 417 mm Dimensions - Packing (H x W x D) 890 x 520 x 450 Weight kg 32 Nominal Cooling Capacity kw 2.60 3.55 4.10 Rated Input Current A 4.45 5.95 7.89 Rated Input Power kw 1.00 1.34 1.78 Refrigerant Type R410A Refrigerant Volume g 350 520 520 Rinnai 5 Portable Room AC OIM

HIGH MID LOW COLL HEAT DRY FAN C F TIMER SLEEP SWING AIR CONDITIONER BASICS APPLIANCE COMPONENTS 2 1 7 8 9 3 6 10 Front 4 5 Back 13 12 11 20 14 19 18 17 16 15 1. Control panel 2. Cool air outlet 3. Receiver window 4. Remote control (Refer separate Remote Control Manual) 5. Exhaust outlet 6. Carry handles 7. Drain outlet 1 8. Drain outlet 2 (not used on this model) 9. Room air intake (filter located behind grill) 10. Lower air intake (filter located behind grill) 11. Swivel casters (x4) 12. Drain tray outlet 13. 1.2m flexible 2 pin cord 220-240V 50Hz 10A 14. Adjustable window slide kit 15. Window exhaust duct window adaptor. 16. Exhaust duct (extends to 1.8M) 17. Duct to appliance adaptor 18. Wall exhaust adaptor 19. Wall exhaust terminal 20. Condensate drain hose Rinnai 6 Portable Room AC OIM

AIR CONDITIONER BASICS CONTROL PANEL 21 22 23 24 25 26 27 28 HIGH MID COOL DRY C TIMER SLEEP LOW FAN SWING 21. Fan Speed Indicators 22. Fan Speed Button 23. Mode Indicators 24. Mode selection Button 25. Temperature Display 26. Temperature Buttons 27. Function Indicators 28. ON/OFF Button IMPORTANT Before operating this appliance ensure that the location, installation and condensation requirements have been met, refer to installation instructions starting on page 11 for details. For the best cooling results ensure that the filters are clean, refer page 9 for details. When the appliance is plugged and the power point is turned on a single beep will be heard and the cool air outlet louvre will cycle open and closed once, this is normal. BASIC OPERATION There are three basic operational modes available, these are COOL (chilled air operation), DRY (chilled and dehumidified operation) and FAN (fan only operation). BASIC OPERATION CONTROL PANEL COOL 1. Press the ON/OFF button (28). 2. Press the mode button (24) until the COOL mode indicator is illuminated. 3. Use temperature buttons (26) to select the desired temperature (16 C to 32 C) 4. Use fan speed button (22) to select the desired fan speed (LOW, MED or HIGH). 5. Press the ON/OFF button (28) to stop operation. DRY (DEHUMIDIFYING) 1. Press the ON/OFF button (28). 2. Press the mode button (24) until the DRY mode indicator is illuminated. 3. Use temperature buttons (26) to select the desired temperature (16 C to 32 C) 4. Press the ON/OFF button (28) Rinnai 7 Portable Room AC OIM

OPERATION FAN 1. Press the ON/OFF button (28). 2. Press the mode button (24) until the FAN mode indicator is illuminated. 3. Use fan speed buttons (22) to select the desired fan speed (LOW, MED or HIGH). 4. Press the ON/OFF button (28) NOTE The most recent basic operational settings are stored in the appliances memory. If the appliance is not disconnected from the mains power supply then these setting will be available the next time the appliance is turned on via the ON/OFF button (28). SLEEP FUNCTION The SLEEP function allows the set temperature to increase and decrease over a 10 hour period at pre-set time intervals to maintain your comfort while saving energy after the 10 hours has passed the appliance will resume normal operation (see graph below).. 1 C 1 C 0 1 2 7 10 12 X C Sleep mode starts 1O hours, X C = Set temperature Sleep mode ends Normal operation resumes Program an Off timer for set & forget operation during Sleep mode Rinnai 8 Portable Room AC OIM

CARE & MAINTENANCE GENERAL MAINTENANCE It is recommended that after each cooling season the exterior panels and display of the appliance are cleaned with a soft damp cloth. Air filters should be checked and cleaned every week during periods of heavy use. For intermittent use this can be extended to 2 to 3 weeks. If storing the appliance for a prolong period remove the plugs and hoses from the drain outlets (7), (8) and (12). 7 9 10 CAUTION ALWAYS turn off the power before you perform any maintenance. DO NOT use solvents, alcohol or harsh cleaners on this appliance or the filters. NEVER use water that is hotter than 40 C when you clean the filters. It may cause deformation or discolouration. 8 12 Back CLEANING THE AIR FILTER There are two air filters in this appliance, there is one filter each fitted to the inside of the Room Air Intake Grill (9), and the Lower Air Intake (10). Before removing the grills, ensure the power cord is disconnected from the power supply. 1. Remove the grills: To remove the Room Air Intake Grill (9) pull down on the top tab and un-clip the grill. To remove the Lower Air Intake Grill (10) use a Philips head screw driver to remove the securing screw and un-clip the grill. 2. Un-clip the filters from each of the grills. Clean the filters with a vacuum cleaner or with warm water. If dirt is difficult to remove, wash the filter in lukewarm water with a mild detergent. 3. Ensuring that the filters are dry before replacing, then clip the filters back into the grill covers. 4. Re-attach the grills: To re-attach the Room Air Intake Grill (9) ensure that all the tabs are properly seated and that the grill is securely clipped back into place. To re-attach the Lower Air Intake Grill (10) ensure that all the tabs are properly seated and that the grill is securely clipped back into place and that the securing screw is replaced. The power may now be reconnected. NOTE Failure to clean the filters regularly can cause excessive condensation to form and reduce the appliances efficiency. If you need replacement filters, please contact Rinnai. Rinnai 9 Portable Room AC OIM

CARE & MAINTENANCE SAVE A SERVICE CALL SYMPTOM POSSIBLE CAUSES POSSIBLE SOLUTIONS Appliance will not operate. Power to Appliance but it will not start. The air conditioner does not generate enough cool air. Too noisy or vibrating. Splashing sound. Not plugged into power. Power switch OFF. Timer Function set. After switching off the appliance there may be a 3 minute delay before it may be re-started. Room temperature is lower than the set temperature. P1 appears on the display. The air intake filters are blocked The set temperature is too high. Drafts from open windows and doors. Other heat sources in the room. Cooling space too big. Operating surface not level High level of condensate being generated. Plug into power. Switch power ON. Wait or reset timer function. Wait 3 minutes. Adjust the set temperature to be lower than the room temperature. Drain the water from the drain outlets. Clean air filters. Adjust the set temperature to a lower temperature. Close windows and doors in the area you want to be cooled. Remove or turn off heat sources. Operate the appliance within the required cooling capacity. Move the appliance to level a operating surface. This is normal. This appliance has a pump that evaporates some condensate through the exhaust duct. WHEN TO CALL FOR SERVICE SYMPTOM CAUSE There is a burning smell and a strange sound coming from the unit. When operated if a circuit breaker (safety, ground) is thrown or a fuse is blown. Turn off the air conditioner, and contact Rinnai. Rinnai 10 Portable Room AC OIM

HIGH MID LOW COLL HEAT DRY FAN C F TIMER SLEEP SWING HIGH MID LOW COLL HEAT DRY FAN F C TIMER SLEEP SWING INSTALLATION LOCATION This portable air conditioner must be installed on a flat and dry surface. A minimum clearance of 500mm from walls or other appliances is required as well as easy access to a power point (GPO). The air outlets and the ducting system must not be obstructed. 500mm 500mm IMPORTANT The appliance is fitted with a 1.2m flexible 2 pin cord 220-240V 50Hz 10A. The maximum duct extension is 1.8m in total. 500mm 500mm Both factors are to be taken into account when determining the location that the appliance will be operated in. DUCT ASSEMBLY 7 8 9 10 Front 5 Back 13 12 11 20 14 19 18 17 16 15 1. Place the Duct to Unit Adaptor (17) over the Exhaust Outlet (5), push it downwards to ensure it engages the Exhaust Outlet tabs. 2. Screw one end of the Exhaust Duct (16) into the Duct to Unit Adaptor (17). 3. On the other end of the Exhaust Duct (16) fix either the Window Exhaust Duct Adaptor (15) or the Wall Exhaust Adaptor (18). Rinnai 11 Portable Room AC OIM

INSTALLATION EXHAUST DUCTING OPTIONS There are two ducting options available for this appliance, these are a Window installation or an optional Semipermanent wall installation. IMPORTANT DO NOT over extend the exhaust duct. Over extension of the exhaust duct can lead to kinking. Kinked ducting causes air flow restrictions and lowers the efficiency of the appliance. Keeping the exhaust duct as short as possible avoids this issue. WINDOW INSTALLATIONS The window kit has been designed to fit most standard vertical and horizontal window applications. There may be some cases where you may need to modify some aspects of this installation procedure for certain window types. Minimum and maximum horizontal / vertical window opening dimensions: Horizontal Window Installation A Vertical Window Installation A Window Installation kit A - Minimum = 675mm A - Maximum = 1250mm 1. Once a suitable window has been chosen, fit the Adjustable Slider Kit (14) into the window areas and fix the length of the kit using the supplied slide lock nut and bolt. Slide lock nut and bolt Insert window exhaust duct adaptor here Foam seal NOTE It is recommended to place a length of foam draft sealing strip along the top and bottom edges of the kit or the inside the window opening to form a seal. 2. Connect the Window Exhaust Duct Adaptor (15) to the Adjustable Slider Kit (14). Rinnai 12 Portable Room AC OIM

SEMI-PERMANENT WALL INSTALLATION INSTALLATION In some cases a window opening might not be assessable; therefore this appliance is supplied with semi-permanent wall flange kit that can be connected the Exhaust Duct. WARNING The positioning and installation of the wall flange should be completed by an authorised person and must comply with all municipal building codes and OH&S guidelines. CONDENSATE DRAINAGE NOTE Condensate produced by this appliance is NOT potable, dispose of via waste outlet or allow to evaporate. 7 INTERNAL CONDENSATE TANK During operation the appliance may produce small amounts of condensate. The appliance has an inbuilt condensate tank. If all three drain outlets (7), (8) and (12) are plugged, then this tank may reach capacity. If this happens, the appliance will stop operation and the condensate full code P1 will be shown on the control panel display and the condensate tank will need to be drained before operation can be resumed. To do this: 8 12 1. Place shallow tray such as an oven baking tray or similar (with at least a 1 litre volume) under Drain Tray Outlet (12). 2. Remove the plug from Drain Tray Outlet (12) and drain out the condensate water, once the condensate is drained replace the plug, the appliance will now be able to then resume operation. Shallow baking tray FIXED CONDENSATE DRAINAGE HOSE As an alternative to using the appliances internal condensate tank, a condensate drain hose (20) may de fitted. 7 Option 1 7 Option 2 8 12 8 12 Option 1 - External Drain Tray: with drain outlets (8) and (12) plugged, fit the condensate drain hose (20) to drain outlet (7) and drain the condensate into a drain tray. Option 2 - Existing Waste Outlet: with drain outlets (7) and (8) plugged, fit the condensate drain hose (20) to drain outlet (12) and drain the condensate into a drain tray or waste outlet. NOTE The point to which the condensate is to be drained MUST BE lower than the drainage outlet point. When using a drain tray option, ensure that the capacity of the tray is greater than that of the condensate being produced. Rinnai 13 Portable Room AC OIM

NOTES Rinnai 14 Portable Room AC OIM

NOTES Rinnai 15 Portable Room AC OIM

CONTACTS Australia Pty. Ltd. ABN 74 005 138 769 100 Atlantic Drive Keysborough, Victoria 3173 P.O. Box 460 Braeside, Victoria 3195 Product Sales & Service National Help Line Tel: 1300 555 545* Fax: 1300 555 655 *Monday to Friday, 8.00am to 5.30pm EST For further information visit www.rinnai.com.au or email enquiry@rinnai.com.au AU45204 Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance. If your appliance requires service, please call our National Help Line. Rinnai recommends that this appliance be serviced at least every 2 years. With our policy of continuous improvement, we reserve the right to change, or discontinue at any time, specifications or designs without notice. Rinnai 16 Portable Room AC OIM Issue 4 - August 2018